Appendix B: Detailed Test Results

This document presents the detailed test results for the Hearing Aid Compatibility (HAC) RF emission measurements for the vivo V2028 mobile phone.

1. GSM

The following table summarizes the E-Field Emission test results for GSM bands:

GSM850 for E-Field Emission
GSM1900 for E-Field Emission

2. LTE

The following table summarizes the E-Field Emission test results for LTE bands:

LTE Band 38 for E-Field Emission
LTE Band 41 for E-Field Emission

Test Laboratory: SGS-SAR Lab

Date: 2020-09-15

Device Under Test (DUT): vivo V2028

Type: Mobile phone

Serial Number: 1918dc2c

Test Configuration:

Device E-Field measurement/E Scan - ER3D:

Measurement Distance: 15 mm from Probe Center to the Device

Test: Hearing Aid Compatibility Test (101x101x1)

Interpolated grid: dx=0.5000 mm, dy=0.5000 mm

Device Reference Point: 0, 0, -6.3 mm

Reference Value: 33.96 V/m

Power Drift: -0.02 dB

Applied MIF: 3.63 dB

RF audio interference level: 31.88 dBV/m

Emission category: M4

MIF scaled E-field:

Grid 1 M4Grid 2 M4Grid 3 M4
31.11 dBV/m31.8 dBV/m31.48 dBV/m
Grid 4 M4Grid 5 M4Grid 6 M4
31.26 dBV/m31.88 dBV/m31.51 dBV/m
Grid 7 M4Grid 8 M4Grid 9 M4
31.22 dBV/m31.7 dBV/m31.34 dBV/m

Cursor:

Total: 31.88 dBV/m

E Category: M4

Location: -1.5, -1, 7.7 mm

Test Configuration:

Device E-Field measurement/E Scan - ER3D:

Measurement Distance: 15 mm from Probe Center to the Device

Test: Hearing Aid Compatibility Test (101x101x1)

Interpolated grid: dx=0.5000 mm, dy=0.5000 mm

Device Reference Point: 0, 0, -6.3 mm

Reference Value: 97.56 V/m

Power Drift: -0.06 dB

Applied MIF: 3.63 dB

RF audio interference level: 40.15 dBV/m

Emission category: M3

MIF scaled E-field:

Grid 1 M4Grid 2 M3Grid 3 M3
37.94 dBV/m40.89 dBV/m40.35 dBV/m
Grid 4 M4Grid 5 M3Grid 6 M4
37.32 dBV/m40.15 dBV/m39.5 dBV/m
Grid 7 M4Grid 8 M4Grid 9 M4
35.78 dBV/m37.09 dBV/m36.58 dBV/m

Cursor:

Total: 40.89 dBV/m

E Category: M3

Location: -2.5, -22, 7.7 mm

Test Configuration:

Device E-Field measurement/E Scan - ER3D:

Measurement Distance: 15 mm from Probe Center to the Device

Test: Hearing Aid Compatibility Test (101x101x1)

Interpolated grid: dx=0.5000 mm, dy=0.5000 mm

Device Reference Point: 0, 0, -6.3 mm

Reference Value: 9.830 V/m

Power Drift: 0.10 dB

Applied MIF: 3.63 dB

RF audio interference level: 26.35 dBV/m

Emission category: M4

MIF scaled E-field:

Grid 1 M4Grid 2 M4Grid 3 M4
26.22 dBV/m27.2 dBV/m26.81 dBV/m
Grid 4 M4Grid 5 M4Grid 6 M4
22.61 dBV/m23.54 dBV/m23.31 dBV/m
Grid 7 M4Grid 8 M4Grid 9 M4
26.35 dBV/m26.35 dBV/m24.66 dBV/m

Cursor:

Total: 27.20 dBV/m

E Category: M4

Location: -3, -25, 7.7 mm

Test Configuration:

Device E-Field measurement/E Scan - ER3D:

Measurement Distance: 15 mm from Probe Center to the Device

Test: Hearing Aid Compatibility Test (101x101x1)

Interpolated grid: dx=0.5000 mm, dy=0.5000 mm

Device Reference Point: 0, 0, -6.3 mm

Reference Value: 39.96 V/m

Power Drift: 0.00 dB

Applied MIF: 3.63 dB

RF audio interference level: 32.28 dBV/m

Emission category: M3

MIF scaled E-field:

Grid 1 M3Grid 2 M3Grid 3 M3
30.13 dBV/m31.86 dBV/m31.82 dBV/m
Grid 4 M4Grid 5 M3Grid 6 M3
29.73 dBV/m32.28 dBV/m32.18 dBV/m
Grid 7 M3Grid 8 M3Grid 9 M3
30.44 dBV/m31.99 dBV/m31.88 dBV/m

Cursor:

Total: 32.28 dBV/m

E Category: M3

Location: -6, 2.5, 7.7 mm

Test Configuration:

Device E-Field measurement/E Scan - ER3D:

Measurement Distance: 15 mm from Probe Center to the Device

Test: Hearing Aid Compatibility Test (101x101x1)

Interpolated grid: dx=0.5000 mm, dy=0.5000 mm

Device Reference Point: 0, 0, -6.3 mm

Reference Value: 20.33 V/m

Power Drift: 0.13 dB

Applied MIF: -1.62 dB

RF audio interference level: 23.76 dBV/m

Emission category: M4

MIF scaled E-field:

Grid 1 M4Grid 2 M4Grid 3 M4
20.94 dBV/m23.49 dBV/m23.48 dBV/m
Grid 4 M4Grid 5 M4Grid 6 M4
21.24 dBV/m23.76 dBV/m23.76 dBV/m
Grid 7 M4Grid 8 M4Grid 9 M4
24.1 dBV/m25.41 dBV/m25 dBV/m

Cursor:

Total: 25.41 dBV/m

E Category: M4

Location: -1.5, 25, 7.7 mm

Test Configuration:

Device E-Field measurement/E Scan - ER3D:

Measurement Distance: 15 mm from Probe Center to the Device

Test: Hearing Aid Compatibility Test (101x101x1)

Interpolated grid: dx=0.5000 mm, dy=0.5000 mm

Device Reference Point: 0, 0, -6.3 mm

Reference Value: 25.02 V/m

Power Drift: -0.05 dB

Applied MIF: -1.44 dB

RF audio interference level: 25.52 dBV/m

Emission category: M4

MIF scaled E-field:

Grid 1 M4Grid 2 M4Grid 3 M4
28.04 dBV/m28.59 dBV/m27.64 dBV/m
Grid 4 M4Grid 5 M4Grid 6 M4
23.91 dBV/m25.52 dBV/m25.52 dBV/m
Grid 7 M4Grid 8 M4Grid 9 M4
19.66 dBV/m21.06 dBV/m21.22 dBV/m

Cursor:

Total: 28.59 dBV/m

E Category: M4

Location: 1, -25, 7.7 mm

Test Configuration:

Device E-Field measurement/E Scan - ER3D:

Measurement Distance: 15 mm from Probe Center to the Device

Test: Hearing Aid Compatibility Test (101x101x1)

Interpolated grid: dx=0.5000 mm, dy=0.5000 mm

Device Reference Point: 0, 0, -6.3 mm

Reference Value: 20.44 V/m

Power Drift: -0.03 dB

Applied MIF: -1.62 dB

RF audio interference level: 23.89 dBV/m

Emission category: M4

MIF scaled E-field:

Grid 1 M4Grid 2 M4Grid 3 M4
21.52 dBV/m23.65 dBV/m23.66 dBV/m
Grid 4 M4Grid 5 M4Grid 6 M4
21.33 dBV/m23.88 dBV/m23.89 dBV/m
Grid 7 M4Grid 8 M4Grid 9 M4
24.07 dBV/m25.37 dBV/m25.01 dBV/m

Cursor:

Total: 25.37 dBV/m

E Category: M4

Location: -1.5, 25, 7.7 mm

Test Configuration:

Device E-Field measurement/E Scan - ER3D:

Measurement Distance: 15 mm from Probe Center to the Device

Test: Hearing Aid Compatibility Test (101x101x1)

Interpolated grid: dx=0.5000 mm, dy=0.5000 mm

Device Reference Point: 0, 0, -6.3 mm

Reference Value: 23.23 V/m

Power Drift: -0.11 dB

Applied MIF: -1.44 dB

RF audio interference level: 25.07 dBV/m

Emission category: M4

MIF scaled E-field:

Grid 1 M4Grid 2 M4Grid 3 M4
27.74 dBV/m28.19 dBV/m27.19 dBV/m
Grid 4 M4Grid 5 M4Grid 6 M4
23.58 dBV/m25.07 dBV/m25.02 dBV/m
Grid 7 M4Grid 8 M4Grid 9 M4
19.81 dBV/m20.88 dBV/m20.88 dBV/m

Cursor:

Total: 28.19 dBV/m

E Category: M4

Location: 1, -25, 7.7 mm

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=4928572 Acrobat Distiller 11.0 (Windows)

Related Documents

Preview vivo V2027 HAC-RF Test Results - GSM850
Detailed test results for the vivo V2027 mobile phone, focusing on Hearing Aid Compatibility (HAC) RF performance for GSM850 frequencies. Includes E-field measurements and emission categories.
Preview VIVO V2027 SAR Test Results: Comprehensive Analysis
Detailed Specific Absorption Rate (SAR) test results for the VIVO V2027 mobile phone, covering GSM and GPRS operations across various frequency bands and configurations. This report provides essential data for understanding the device's radiofrequency exposure.
Preview Amendment Letter for FCC ID 2AUCY-V2027
This document is an amendment letter from TIMCO Engineering, Inc. requesting a report update for FCC ID 2AUCY-V2027. It details changes made to the original report, including data conversion error correction, equipment list updates, and revisions to support units, test facility, and test location.
Preview V2027 Smartphone Quick Start Guide - vivo
This guide provides essential information for setting up and using your vivo V2027 smartphone, including technical specifications, safety information, and FCC compliance details.
Preview FCC Test Report for vivo V2028 Mobile Phone
This FCC test report details the compliance of the vivo V2028 mobile phone with relevant FCC regulations. It includes test results for conducted emissions, emission bandwidth, occupied bandwidth, power spectral density, radiated spurious emissions, and dynamic frequency selection.
Preview FCC Test Report for vivo V2027 Mobile Phone
This FCC test report details the compliance of the vivo V2027 mobile phone with FCC regulations, including emission bandwidth, occupied bandwidth, conducted output power, spectral density, radiated spurious emissions, and frequency stability. The report was prepared by SGS-CSTC Standards Technical Services Co., Ltd.
Preview VIVO V2028 SAR Test Results: GSM and GPRS Performance
Detailed Specific Absorption Rate (SAR) test results for the VIVO V2028 mobile phone, covering GSM and GPRS operations across various frequency bands and configurations. This report provides comprehensive data on radio frequency exposure levels.
Preview FCC Test Report for vivo V2027 Mobile Phone
This FCC test report details the compliance of the vivo V2027 mobile phone with FCC Part 15C regulations. It includes test summaries, conducted emissions data, and antenna requirements.