Instructions for LOCKWOOD models including: 3570 Series Electric Mortice Lock, 3570 Series, Electric Mortice Lock, Mortice Lock, Lock
1 lug 2023 — HAND OF DOOR ACCORDING TO ENGLISH PRACTICE. All Lockwood 3570 Series Electric Mortice Locks are mounted in accordance with these instructions.
3570 SERIES ELECTRIC MORTICE LOCKS. BEFORE DRILLING HOLES, CHECK THAT. THEY WILL SUIT LOCKSET TO BE FITTED. ESCAPE. HOLE. Ø20 FOR. TEAR HERE. 127mm BACKSET.
P/No. 3570-5721 30621 0612 3570 SERIES ELECTRIC MORTICE LOCK MOUNTING INSTRUCTIONS HAND OF DOOR ACCORDING TO ENGLISH PRACTICE RIGHT - HAND DOOR LEFT - HAND DOOR OUTSIDE DOOR OPENING IN OUTSIDE DOOR OPENING OUT 1 OUTSIDE DOOR OPENING IN OUTSIDE DOOR OPENING OUT Determine hand of lock required from above hand of door chart. Rotate bolt head to suit latching direction. 2 LOCK STATUS Ensure Snib Cam is exposed. FAIL SAFE locks ( Snib Cam is exposed ). For FAIL SECURE locks invert the lock so the Snib Cam screw is exposed. All Lockwood 3570 Series Electric Mortice Locks are mounted in accordance with these instructions. Locks may or may not have cylinders, lever handles, turn knob or emergency button. Disregard instructions referring to the features not required. Important : Before drilling door, ensure correct hand is being installed. NOTE: CASE DOES NOT need to be opened, to change HAND or FUNCTION of LOCK. 4 SETTING LOCK HANDING (cont'd) Vestibule Locks With single action Escape feature. : DOT to be UP on Lockable side and DOWN on the Escape side when case is upright. VESTIBULE R/HAND DOOR (FAIL SAFE) LOCKABLE ESCAPE VESTIBULE L/HAND DOOR (FAIL SAFE) FAIL SAFE FAIL SECURE FAIL SECURE INVERT LOCK To reveal SNIB CAM 3 SETTING LOCK HANDING SNIB CAM Rotation of the Snib Cam hands the lock. Use a small flat screwdriver to rotate cam if required. Combination Locks (Both handles can be rotated) DOT to be in the UP position when case is upright. COMBINATION ESCAPE LOCKABLE VESTIBULE R/HAND DOOR (FAIL SECURE) Lock Inverted ESCAPE LOCKABLE VESTIBULE L/HAND DOOR (FAIL SECURE) Lock Inverted LOCKABLE LOCKABLE COMBINATION (FAIL SECURE) Lock Inverted LOCKABLE LOCKABLE LOCKABLE ESCAPE 5 SELECTING FAIL SAFE / FAIL SECURE The lock is factory set to FAIL SAFE. To set to FAIL SECURE remove screw from `FAIL SAFE' position and manually screw into `FAIL SECURE' position. WARNING: Do not use a power driver to tighten screw. 6 8 MONITOR SELECTION FURNITURE WITH L.E.D. SIDE B Key Override Monitor Selection N/O N/C K.O.M SWITCH SELECTION KEY OVERRIDE MONITOR SELECTION Set the 2 WAY SWITCH to desired setting. Hub Monitor Selection Before assembling furniture to door, connect LED cable to 3 pin socket located at TOP of lock body. FAIL SECURE LOCK FAIL SAFE LOCK GREEN CABLE GREEN CABLE GREEN CABLE GREEN CABLE HUB MONITOR SELECTION Select normally open, normally closed, ON OFF Lock Side A or Lock Side B ON monitoring configuration. OFF ON OFF ON OFF 7 Door TBHTEHI3FS5AO6ITSR0TEASHEDCETRROYOIIMELWBSLMIEILMONLFGNOISTRTHUTTEOEIITMCLDPEE.LLSOLA,OCCTCKEHKSEFESCOT.KR SWITCH No. 1 2 3 4 LOCK NORMAL SIDE FUNCTION A N/C A N/O B N/C B N/O DOOR PREPARATION Centreline Mortice template 9 LOCKS WITH CYLINDERS Using a small flat screwdriver, lever out Cylinder Hole Plug where fitted. Connect power plug from lock to power supply socket and place lock in mortice and insert cylinder. Secure cylinder with retainer pin, ensuring pin is flush with front plate. Secure lock to door with 2 woodscrews supplied. Install cover plate and secure with 2 M4 screws to lock body. Mortice Centreline FOLD LINE ALONG EDGE OF DOOR 60mm BACKSET ENSURE LOCK IS REMOVED FROM MORTICE 60 mm FBOa2Rc20kHCmsOYemLLtIENDDSIAER FO2R2HmSOPmLINEDDIALE LOCKS WITHOUT CYLINDERS Connect power plug from lock to power supply socket and place lock in mortice. Secure lock to door with 2 woodscrews supplied. Install cover plate and secure with 2 M4 screws to lock body. IMPOREDTGEAA NT - To prevent damage to the door face from drill "breakthrough", MARK BOTH SIDES OF DOOR & DRILL HOLES HALF WAY THROUGH EACH SIDE Establish height that lockset will be mounted on door and mark centreline of door thickness on door edge. Place Mortice Template on door and align centreline on template with centreline on door. Secure with sticky tape. Mark and drill mortice to suit mortice lock depth (90mm). Ease out mortice cavity where necessary. Clean out mortice before inserting lock. Allow space for extra cable length behind lock for ease of maintenance. 10 All locks are supplied with spindles. Insert spindle(s) into lock, as required. Assemble furniture as required. Ensure furniture is not over-tightened. LOCKS WITH SPINDLES IMPORTANT : Attach spindle spring to rear of spindle before assembling 11 MOUNTING STRIKE AND MAGNET Cover plate (Square) Cover plate (Round) Insert lock in mortice with Cover Plate on and scribe around Cover Plate for size of recess, ensuring that no foreign matter finds it way into the lock mechanism. Remove lock from mortice and chisel recess 4mm deep to receive both front and cover plate. Cover plate must be flush with edge of door. Ensure lock is removed from mortice cavity. Fold template along backset fold line. Align EDGE A with bottom of cover plate recess. Establish holes required to suit lock function, mark hole centres accurately, drill and clean holes. Drill furniture holes as required. Fasten mortice lock into door using mounting screws provided. Mark out door frame for strike. Mortice door frame for strike box and strike. Bolt recess to be 15mm deep in door frame. Screw strike and strike box to door frame with 2 screws supplied. Drill 19mm DIA hole x 40 Deep, 62mm above strike centreline. Insert magnet in hole. ELECTRICAL SPECIFICATIONS Note : Diagram depicts RH opened door, with handle & key in rest state. SOLENOID RED EXTERNAL LED PROTECTION DIODE SOLENOID DRIVER CIRCUITRY LED DRIVER CIRCUITRY Solenoid Activation Operating Voltage: 12~30Vdc Operating Current: 500mA Max, 80mA holding @ 12Vdc 275mA Max, 50mA holding @ 24Vdc Led Current Add 20mA to Total Operating Current if Led's are fitted. Monitoring Circuits Microswitches: 500mA Max @ 30Vdc each circuit Reedswitch: 100mA Max @ 30Vdc GREEN REEDSWITCH DEADLATCHING LOCKING BAR MONITORING NC NO SIDE A (1) NC NO SIDE B (2) (3) NO/NC SELECTION (4) DIL SWITCH NC NO KOM Solenoid 0Vdc (Black) Solenoid Positive (Red) LED (Green) Reedswitch (NC) (Yellow) Reedswitch Common (Pink) Deadlatched and Locked (NC) (L.Blue) Deadlatched and Locked Common (Grey) Hub monitor (NO or NC) (Brown) Hub monitor Common (Blue) Key override monitor (NO or NC) (Orange) Key override monitor Common (Violet) Not connected (White) COLOUR Black Red Yellow Pink Light Blue Grey Brown Blue Orange Violet Green White FUNCTION Solenoid 0Vdc Solenoid Positive (12~30Vdc) Door closed Reed Switch (NC) Reed Switch Common Deadlatched and Locked (NC) Deadlatched and Locked Common Hub monitor (NO or NC) Hub monitor Common Key override monitor (NO or NC) Key override monitor Common LED (12~30Vdc) Not connected Mortice Centreline FOLD LINE ALONG EDGE OF DOOR 60mm BACKSET ENSURE LOCK IS REMOVED FROM MORTICE BEFORE DRILLING HOLES DO NOT DRILL HOLES RIGHT THROUGH DOOR TO PREVENT POSSIBLE DAMAGE TO DOOR FACE. WARNING CARE MUST BE TAKEN WHEN DRILLING & AFFIXING SCREWS. SCREWS MUST NOT COME IN CONTACT WITH ELECTRICAL WIRES ALLOW EXTRA CABLE LENGTH BEHIND LOCK FOR EASE OF MAINTENANCE. THIS IS A COMMON TEMPLATE FOR 3570 SERIES ELECTRIC MORTICE LOCKS. BEFORE DRILLING HOLES, CHECK THAT THEY WILL SUIT LOCKSET TO BE FITTED. HOLE 20mm DIA FOR L.E.D. CABLE 7 HOLES 20mm DIA x130mm DEEP (for 60mm Backset) 2 HOLES 20mm DIA FOR CYLINDER HOLE 22mm DIA FOR SPINDLE EDGE A FOLD LINE ALONG EDGE OF DOOR 60mm BACKSET ENSURE LOCK IS REMOVED FROM MORTICE BEFORE DRILLING HOLES DO NOT DRILL HOLES RIGHT THROUGH DOOR TO PREVENT POSSIBLE DAMAGE TO DOOR FACE. WARNING CARE MUST BE TAKEN WHEN DRILLING & AFFIXING SCREWS. SCREWS MUST NOT COME IN CONTACT WITH ELECTRICAL WIRES ALLOW EXTRA CABLE LENGTH BEHIND LOCK FOR EASE OF MAINTENANCE. THIS IS A COMMON TEMPLATE FOR 3570 SERIES ELECTRIC MORTICE LOCKS. BEFORE DRILLING HOLES, CHECK THAT THEY WILL SUIT LOCKSET TO BE FITTED. 2 HOLES 20mm DIA FOR CYLINDER HOLE 22mm DIA FOR SPINDLE HOLE 20mm DIA FOR L.E.D. CABLE EDGE AAdobe InDesign 18.3 (Windows) Adobe PDF Library 17.0