Instructions for LOCKWOOD models including: 3570 Series Electric Mortice Lock, 3570 Series, Electric Mortice Lock, Mortice Lock, Lock

3570 SERIES ELECTRIC MORTICE LOCK

1 lug 2023 — HAND OF DOOR ACCORDING TO ENGLISH PRACTICE. All Lockwood 3570 Series Electric Mortice Locks are mounted in accordance with these instructions.

[PDF] 3570-series-electric-mortice-lock-mounting-instructions ... - Lockwood

3570 SERIES ELECTRIC MORTICE LOCKS. BEFORE DRILLING HOLES, CHECK THAT. THEY WILL SUIT LOCKSET TO BE FITTED. ESCAPE. HOLE. Ø20 FOR. TEAR HERE. 127mm BACKSET.

PDF preview unavailable. Download the PDF instead.

3570-series-electric-mortice-lock-mounting-instructions
P/No. 3570-5721 30621 0612

3570 SERIES ELECTRIC MORTICE LOCK
MOUNTING INSTRUCTIONS

HAND OF DOOR ACCORDING TO ENGLISH PRACTICE

RIGHT - HAND DOOR

LEFT - HAND DOOR

OUTSIDE DOOR OPENING
IN

OUTSIDE DOOR OPENING
OUT

1

OUTSIDE DOOR OPENING
IN

OUTSIDE DOOR OPENING
OUT

Determine hand of lock required from above hand of door chart. Rotate bolt head to suit latching direction.

2

LOCK STATUS

Ensure Snib Cam is exposed.
FAIL SAFE locks ( Snib Cam is exposed ). For FAIL SECURE locks invert the lock so the Snib Cam screw is exposed.

All Lockwood 3570 Series Electric Mortice Locks are mounted in accordance with these instructions. Locks may or may not have cylinders, lever handles, turn knob or emergency button. Disregard instructions referring to the features not required. Important : Before drilling door, ensure correct hand is being installed. NOTE: CASE DOES NOT need to be opened, to change HAND or FUNCTION of LOCK.

4

SETTING LOCK HANDING (cont'd)

Vestibule Locks

With single action Escape feature.

: DOT to be UP on Lockable side and DOWN on the Escape side

when case is upright.

VESTIBULE R/HAND DOOR (FAIL SAFE)

LOCKABLE

ESCAPE

VESTIBULE L/HAND DOOR (FAIL SAFE)

FAIL SAFE

FAIL SECURE

FAIL SECURE
INVERT LOCK To reveal SNIB CAM

3

SETTING LOCK HANDING

SNIB CAM

Rotation of the Snib Cam hands the lock. Use a small flat screwdriver

to rotate cam if required.

Combination Locks

(Both handles can be rotated) DOT to be in the UP position when

case is upright.

COMBINATION

ESCAPE

LOCKABLE

VESTIBULE R/HAND DOOR (FAIL SECURE) Lock Inverted

ESCAPE

LOCKABLE

VESTIBULE L/HAND DOOR (FAIL SECURE) Lock Inverted

LOCKABLE

LOCKABLE

COMBINATION (FAIL SECURE) Lock Inverted

LOCKABLE

LOCKABLE

LOCKABLE

ESCAPE

5

SELECTING FAIL SAFE / FAIL SECURE

The lock is factory set to FAIL SAFE. To set to FAIL SECURE remove screw from `FAIL SAFE' position and manually screw into `FAIL SECURE' position.
WARNING: Do not use a power driver to tighten screw.

6

8 MONITOR SELECTION

FURNITURE WITH L.E.D.

SIDE B

Key Override Monitor Selection

N/O
N/C
K.O.M SWITCH SELECTION

KEY OVERRIDE MONITOR SELECTION
Set the 2 WAY SWITCH to desired setting.

Hub Monitor Selection

Before assembling furniture to door, connect LED cable to 3 pin socket located at TOP of lock body.

FAIL SECURE LOCK

FAIL SAFE LOCK

GREEN CABLE

GREEN CABLE

GREEN CABLE

GREEN CABLE

HUB MONITOR SELECTION

Select normally open, normally closed,

ON OFF

Lock Side A or

Lock Side B

ON

monitoring configuration. OFF

ON OFF

ON OFF

7

Door

TBHTEHI3FS5AO6ITSR0TEASHEDCETRROYOIIMELWBSLMIEILMONLFGNOISTRTHUTTEOEIITMCLDPEE.LLSOLA,OCCTCKEHKSEFESCOT.KR

SWITCH No.
1 2 3 4

LOCK NORMAL SIDE FUNCTION
A N/C

A N/O B N/C

B N/O
DOOR PREPARATION
Centreline

Mortice template

9

LOCKS WITH CYLINDERS

Using a small flat screwdriver, lever out Cylinder Hole Plug where fitted. Connect power plug from lock to power supply socket and place lock in mortice and insert cylinder. Secure cylinder with retainer pin, ensuring pin is flush with front plate. Secure lock to door with 2 woodscrews supplied. Install cover plate and secure with 2 M4 screws to lock body.

Mortice Centreline FOLD LINE ALONG EDGE OF DOOR 60mm BACKSET
ENSURE LOCK IS REMOVED FROM MORTICE

60 mm FBOa2Rc20kHCmsOYemLLtIENDDSIAER FO2R2HmSOPmLINEDDIALE

LOCKS WITHOUT CYLINDERS Connect power plug from lock to power supply socket and place lock in mortice. Secure lock to door with 2 woodscrews supplied. Install cover plate and secure with 2 M4 screws to lock body.

IMPOREDTGEAA NT - To prevent damage to the door face from drill "breakthrough", MARK BOTH SIDES OF DOOR & DRILL HOLES HALF WAY THROUGH EACH SIDE
Establish height that lockset will be mounted on door and mark centreline of door thickness on door edge. Place Mortice Template on door and align centreline on template with centreline on door. Secure with sticky tape. Mark and drill mortice to suit mortice lock depth (90mm). Ease out mortice cavity where necessary. Clean out mortice before inserting lock. Allow space for extra cable length behind lock for ease of maintenance.

10
All locks are supplied with spindles. Insert spindle(s) into lock, as required. Assemble furniture as required. Ensure furniture is not over-tightened.

LOCKS WITH SPINDLES
IMPORTANT : Attach spindle spring to rear of spindle before assembling

11

MOUNTING STRIKE AND MAGNET

Cover plate (Square)

Cover plate (Round)

Insert lock in mortice with Cover Plate on and scribe around Cover Plate for size of recess, ensuring that no foreign matter finds it way into the lock mechanism. Remove lock from mortice and chisel recess 4mm deep to receive both front and cover plate. Cover plate must be flush with edge of door. Ensure lock is removed from mortice cavity. Fold template along backset fold line. Align EDGE A with bottom of cover plate recess. Establish holes required to suit lock function, mark hole centres accurately, drill and clean holes. Drill furniture holes as required. Fasten mortice lock into door using mounting screws provided.

Mark out door frame for strike. Mortice door frame for strike box and strike. Bolt recess to be 15mm deep in door frame. Screw strike and strike box to door frame with 2 screws supplied. Drill 19mm DIA hole x 40 Deep, 62mm above strike centreline. Insert magnet in hole.

ELECTRICAL SPECIFICATIONS

Note : Diagram depicts RH opened door, with handle & key in rest state.
SOLENOID RED
EXTERNAL LED

PROTECTION DIODE

SOLENOID DRIVER
CIRCUITRY

LED DRIVER CIRCUITRY

Solenoid Activation Operating Voltage: 12~30Vdc
Operating Current: 500mA Max, 80mA holding @ 12Vdc 275mA Max, 50mA holding @ 24Vdc
Led Current Add 20mA to Total Operating Current if Led's are fitted.
Monitoring Circuits Microswitches: 500mA Max @ 30Vdc each circuit Reedswitch: 100mA Max @ 30Vdc

GREEN

REEDSWITCH

DEADLATCHING

LOCKING BAR MONITORING

NC

NO

SIDE A (1)

NC

NO

SIDE B (2)

(3)

NO/NC SELECTION

(4) DIL SWITCH
NC NO

KOM

Solenoid 0Vdc (Black)
Solenoid Positive (Red)
LED (Green) Reedswitch (NC) (Yellow) Reedswitch Common (Pink) Deadlatched and Locked (NC) (L.Blue) Deadlatched and Locked Common (Grey)
Hub monitor (NO or NC) (Brown)
Hub monitor Common (Blue)
Key override monitor (NO or NC) (Orange)
Key override monitor Common (Violet) Not connected (White)

COLOUR
Black Red Yellow Pink Light Blue Grey Brown Blue Orange Violet Green White

FUNCTION
Solenoid 0Vdc Solenoid Positive (12~30Vdc) Door closed Reed Switch (NC) Reed Switch Common Deadlatched and Locked (NC) Deadlatched and Locked Common Hub monitor (NO or NC) Hub monitor Common Key override monitor (NO or NC) Key override monitor Common LED (12~30Vdc) Not connected

Mortice Centreline
FOLD LINE ALONG EDGE OF DOOR 60mm BACKSET
ENSURE LOCK IS REMOVED FROM MORTICE BEFORE DRILLING HOLES
DO NOT DRILL HOLES RIGHT THROUGH DOOR TO PREVENT POSSIBLE DAMAGE TO DOOR FACE.
WARNING CARE MUST BE TAKEN WHEN DRILLING & AFFIXING SCREWS. SCREWS MUST NOT COME IN CONTACT WITH ELECTRICAL WIRES
ALLOW EXTRA CABLE LENGTH BEHIND LOCK FOR EASE OF MAINTENANCE.

THIS IS A COMMON TEMPLATE FOR 3570 SERIES
ELECTRIC MORTICE LOCKS. BEFORE DRILLING HOLES, CHECK THAT THEY WILL SUIT LOCKSET
TO BE FITTED.

HOLE
20mm DIA FOR
L.E.D. CABLE

7 HOLES
20mm DIA x130mm DEEP (for 60mm Backset)
2 HOLES
20mm DIA FOR CYLINDER
HOLE
22mm DIA FOR SPINDLE

EDGE A

FOLD LINE ALONG EDGE OF DOOR 60mm BACKSET ENSURE LOCK IS REMOVED FROM MORTICE
BEFORE DRILLING HOLES DO NOT DRILL HOLES RIGHT THROUGH DOOR TO PREVENT POSSIBLE DAMAGE TO DOOR FACE.
WARNING CARE MUST BE TAKEN WHEN DRILLING & AFFIXING SCREWS. SCREWS MUST NOT COME IN CONTACT WITH ELECTRICAL WIRES
ALLOW EXTRA CABLE LENGTH BEHIND LOCK FOR EASE OF MAINTENANCE.

THIS IS A COMMON TEMPLATE FOR 3570 SERIES
ELECTRIC MORTICE LOCKS. BEFORE DRILLING HOLES, CHECK
THAT THEY WILL SUIT LOCKSET TO BE FITTED.

2 HOLES
20mm DIA FOR CYLINDER
HOLE
22mm DIA FOR SPINDLE

HOLE
20mm DIA FOR
L.E.D. CABLE

EDGE A


Adobe InDesign 18.3 (Windows) Adobe PDF Library 17.0