Arrow NaviCurve™™ One-Lumen PICC pre-loaded with Arrowg+ard™™
Reference: DLX-45541-CURVC
Product Details:
- Catheter Type: Pressure Injectable Arrowg+ard™™ Blue Advance® One-Lumen PICC
- Catheter Length: 55 cm
- Catheter Diameter: 4.5 Fr. (1.58 mm OD)
- Spring-Wire Guide: 0.018 inch (0.46 mm) diameter, 17-3/4" (45 cm)
- Protection: Antimicrobial/Antithrombogenic
- Latex Content: Not made with natural rubber latex.
- Storage Conditions: Store between 20 - 25°C (68 – 77°F).
Contents:
- One Lumen TaperFree® Catheter‡‡‡ with Arrowg+ard Blue Advance® Antimicrobial/Antithrombogenic Protection: 4.5 Fr. (1.58 mm OD) x 55 cm, Pressure Injectable, Arrow® NaviCurve™™ Stylet and T-Port Connector
- GlideThru™™ Peel-Away Sheath: 4.5 Fr. x 2-3/4" (7 cm) Radiopaque over 4.5 Fr. Dilator
- Spring-Wire Guide, Nitinol, Marked: 018" (0.46 mm) dia. x 17-3/4" (45 cm) (Straight Soft Tip on One End - Straight Stiff Tip on Other) with Arrow Advancer
- Injection Needle: Eclipse M2 25 Ga. x 1" (2.54 cm)
- Safety Introducer Needle: Echogenic 21 Ga. x 2-3/4" (7 cm) TW
- Introducer Needle: Echogenic 21 Ga. x 2-3/4" (7 cm) TW
- Syringe: 5 mL Luer-Lock
- Blunt Fill Needle: 18 Ga. x 1-1/2" (3.81 cm)
- 10 mL Luer-Lock Pre-Filled Saline Syringe
- 5 mL 1% Lidocaine HCI Solution and Alcohol Prep
- 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution
- 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™™ Tint
- Dust Cap: Non-Vented
- SharpsAway® II Locking Disposal Cup
- SharpsAway® Disposal Cup
- Catheter Trimmer
- Towel: 24" x 36" (61 cm x 91 cm)
- Maximal Barrier Drape™™ with two 13 cm (5") x 15 cm (6") fenestrations
- Sterile Procedure Sign
- Patient ID Card
- Patient Information Booklet
- Medication Label: 1% Lidocaine
- Paper Tape Measure
- Tourniquet
- Foam Electrodes (3 per pack)
- Gauze Pad: 2" x 2" (5 cm x 5 cm)
- Gauze Pad: 4" x 4" (10 cm x 10 cm)
- Surgical Apparel: Impervious Gown
- Dressing: Tegaderm®4 CHG 3-1/2" x 4-1/2" (8.5 cm x 11.5 cm)
- Remote Cover
- Transducer Cover with Gel and Rubber Bands
- Dressing: STATLOCK®5 PICC Plus Catheter Stabilization Device
- Surgical Apparel: Bouffant Cap
- Surgical Apparel: Mask
- Surgical Apparel: Mask with Eye Shield
- Tape: Steri-Strip®4
- T-Piece Cover
Important Information
Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.
Contraindications:
The Pressure Injectable Arrowg+ard Blue Advance antimicrobial/antithrombogenic catheter is contraindicated:
- for patients with known hypersensitivity to chlorhexidine
- in the presence of device related infection in the intended insertion vessel or catheter pathway
- in the presence of thrombosis in the intended insertion vessel or catheter pathway
Specifications:
Lumen | Priming Volume* (mL) | Gravity Flow Rate† (mL/hr) | Pump Flow Rate†† (mL/hr) | MAX Pressure Injection Flow Rate** (mL/sec) |
---|---|---|---|---|
One (Pink, 17 Ga.) | 0.66 | 1090 | 5380 | 5 |
* Priming volumes are approximate and are done without accessories.
† Flow rate values are approximate and are determined using deionized water at 100 cm head height.
†† Pump flow rates are determined at maximum pump pressure of 10 psig and represent approximate flow capabilities.
** Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.
Regulatory Information:
- CAS #: 7440-48-4
- MR Safe
- UDI: [Unique Device Identifier]
- Reference: PB-10000-8508.5 X 10.5
- Document Revision: LBL080193 R00 (2025-06)