Humphrey Field Analyzer 3 from ZEISS

Advancing clinical efficiency for glaucoma

Reduce testing time and increase insight into glaucoma with the ZEISS Humphrey Field Analyzer 3.

The ZEISS HFA3 featuring SITA Faster Testing

The Humphrey® Field Analyzer 3 (HFA3) combines everything you value in a Humphrey with expanded testing options and reduced patient test times.

Optimize results for you and your patient.

Everything you depend on, only from a Humphrey

The innovations in HFA3 add to the reliable standard that thousands of practices already depend on for essential diagnoses.

SITA “adapts” to patient responses

HFA SITA™ Strategies are the standard of care in visual field testing. SITA makes optimal use of the information contained in the patient's responses, looks at the complete pattern of patient responses while thresholding, and continuously refines the measurements.

Obtain more information in central visual field

The new SITA Faster 24-2C test adds 10 test points to the 24-2 pattern. They were selected to examine areas along physiologically relevant nerve fiber bundles known to be susceptible to glaucomatous defects. 1-6

Threshold testing is faster than ever with SITA Faster 24-2

SITA Faster 24-2 improves clinical workflow and patient satisfaction with the fastest test time in HFA threshold testing. Approximately 50% faster than SITA Standard, SITA Faster 24-2 is also about 30% quicker than SITA Fast, yet offers the same reproducibility.

Expert analysis of visual field test results

STATPACT™ statistical software compares results to proprietary age normative and glaucoma databases for analyzing changes in the patient's visual field over time.

1 Heijl A¹, Patella VM², Chong LX³, Iwase A4, Leung CK5, Tuulonen A6, Lee GC2, Callan T², Bengtsson B'. A new SITA perimetric threshold testing algorithm; construction and a multi-center clinical study. Am J Ophthalmol. 2018 Oct 15. pii: S0002-9394(18)30592-0. doi: 10.1016/j.ajo.2018.10.010. [Epub ahead of print]

2 Donald C. Hood, a,b,,1 Ali S. Raza, a,c,1 Carlos Gustavo V. de Moraes, de, 1 Jeffrey M. Liebmann, de, 1 and Robert Ritchd.f. 1. Glaucomatous damage of the macula. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3529818/

3 Ilana Traynis, B.S., 1,2 Carlos G. De Moraes, M.D., 4.5 Ali S. Raza, B.A.,¹ Jeffrey M. Liebmann, M.D., 4.5 Robert Ritch, M.D., 4.6 and Donald C. Hood, Ph.D. 1.3. The Prevalence and Nature of Early Glaucomatous Defects in the Central 10° of the Visual Field. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4204644/

4 De Moraes CG¹, Hood DC², Thenappan A³, Girkin CA4, Medeiros FA5, Weinreb RN5, Zangwill LM5, Liebmann JM6. Visual Fields Miss Central Defects Shown on 10-2 Tests in Glaucoma Suspects, Ocular Hypertensives, and Early Glaucoma. Ophthalmology. 2017 Oct; 124(10):1449-1456. doi: 10.1016/j.ophtha.2017.04.021. Epub 2017 May 24. 24-2. https://www.ncbi.nlm.nih.gov/pubmed/28551166 Invest Ophthalmol Vis Sci. 2014 Feb 3;55(2):632-49. doi: 10.1167/iovs.13-13130.

5 Hood DC¹, Slobodnick A, Raza AS, de Moraes CG, Teng CC, Ritch R. Early glaucoma involves both deep local, and shallow widespread, retinal nerve fiber damage of the macular region. https://www.ncbi.nlm.nih.gov/pubmed/24370831

6 Donald C. Hood, 1.2 Matthew Nguyen, Alyssa C. Ehrlich,¹ Ali S. Raza, 1.3 leva Sliesoraityte, 4.5 Carlos G. De Moraes, 2 Robert Ritch, 6.7 and Ulrich Schiefer4.8. A Test of a Model of Glaucomatous Damage of the Macula With High-Density Perimetry: Implications for the Locations of Visual Field Test Points. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4064621/

Inform your decision-making with GPA

GPA™ (Guided Progression Analysis) is designed to help you identify where, and how fast, defects are progressing. GPA allows transition to new SITA tests while maintaining analysis of the complete patient history.

Identify consecutive change at each test point

Progression Analysis Probability Plot is designed to identify statistically significant progression events in consecutive visits at individual test points. GPA Alert displays a plain language message about the likelihood of disease progression.

Visualize rate of progression

Visual Field Index™ (VFI) is a measure of the patient's overall visual function as compared to an age-adjusted normal population. VFI trend analysis helps differentiate rapid versus slow progressing visual field loss.

HFA3 makes visual field testing faster and easier than ever

Simple to operate

  1. Liquid Trial Lens technology: reduces setup time by automatically loading each patient's refractive correction from the previous exam.
  2. Automated eye alignment: centers the patient's eye to the trial lens and adjusts to the patient during the test to provide fast setup and best results.
  3. Intuitive SmartTouch interface: simply select the patient's name and press start to begin testing.

Enhancing workflow from patient testing to report review

New Review Software: delivers comprehensive analysis and improves digital workflow.

Data Synchronization: automatically updates and integrates patient tests from any connected HFA3. HFA-IIi contributes tests to HFA3, enabling you to use existing HFA-IIi devices to supplement testing capacity.

Technical data Specifications

Choose the HFA3 that's right for you

Specifications HFA3 830 HFA3 840 HFA3 850 HFA3 860 Humphrey Matrix 800 Humphrey FDT
Test specifications
Maximum temporal range (degrees) 90 90 90 90 30 30
Stimulus duration 200 ms 200 ms 200 ms 200 ms 300 ms 200-400 ms
Visual field testing distance 30 cm 30 cm 30 cm 30 cm Infinity Infinity
Background illumination 31.5 ASB 31.5 ASB 31.5 ASB 31.5 ASB 100 cd/m² 100 cd/m²
Threshold test library
N-30
C-20
24-2, 30-2, 10-2, Macula
60-4, Nasal step
Threshold test strategies
SITA Standard, SITA Fast, SITA Faster, Full Threshold, FastPac
SITA-SWAP
MOBS
ZEST
Suprathreshold test library
C40, C76, C80
C64, C-Armaly
C-20
N-30
24-2
Peripheral test patterns
Suprathreshold test modes
Age corrected
Threshold related, Single intensity
Specialty test library
Social Security Disability, monocular, binocular
Esterman monocular, binocular, superior 36, 64
Kinetic testing
Custom Kinetic testing
Custom Static testing
Features HFA3 830 HFA3 840 HFA3 850 HFA3 860 Humphrey Matrix 800 Humphrey FDT
Fixation control
Heijl-Krakau blind spot monitor
Video eye monitor
Gaze tracking
Head tracking
Vertex monitoring
Operator interface
Display Touchscreen LCD Touchscreen LCD Touchscreen LCD Touchscreen LCD LCD LCD
Keyboard
Stimulus
Frequency doubling
White-on-white
Red- or blue-on-white
Blue-on-yellow (SWAP)
General testing features
Stimulus sizes Goldmann I-V Goldmann I-V Goldmann I-V Goldmann I-V 10° 2°, 5°, 10°
Foveal threshold testing
Automatic pupil measurement
Liquid Trial Lens (AutoTLC)
RelEYE eye review
Test storage
User-defined
Software features
Single Field Analysis (SFA)
Glaucoma Hemifield Test (GHT)
Visual Field Index (VFI)
Guided Progression Analysis (GPA)
Mixed GPA
Serial field overview
Networking
FORUM Connectivity
DICOM Connectivity
Printer
Thermal printer
Native generic PCL 3, PCL 5 and postscript printer support for local, shared and networked printers
Native postscript printer support for network capable printers Optional Optional Optional Optional
Data storage, retrieval and analysis
Hard drive 500 GB 500 GB 500 GB 500 GB 250 GB 250 GB
USB
CD-R/W drive
Dimensions
Height 23" (58 cm) 17" (43 cm) 17" (43 cm) 17" (43 cm) 17" (43 cm) 17" (43 cm)
Width 20" (51 cm) 10" (25 cm) 12.2" (31 cm) 12.2" (31 cm) 12.2" (31 cm) 12.2" (31 cm)
Depth 18" (46 cm) 19" (48 cm) 19" (48 cm) 19" (48 cm) 33.5" (85 cm) 33.5" (85 cm)
Weight 63 lbs (28.7 kg) 19 lbs (8.6 kg) 19 lbs (8.6 kg) 19 lbs (8.6 kg) 37.5 lbs (17.4 kg) 37.5 lbs (17.4 kg)
Electrical requirements 100-120V~, 50/60Hz, 4.0A
230V~, 50/60Hz, 1.8A
100-120V, 50/60Hz
230V, 50/60Hz
100-120V, 50/60Hz
230V, 50/60Hz
100-120V, 50/60Hz
230V, 50/60Hz
100-240V~, 50/60Hz,
200VA max
100-240V~, 50/60Hz,
200VA max
Standards Meets UL, CSA and CE standards Meets UL, CSA and CE standards Meets UL, CSA and CE standards Meets UL, CSA and CE standards Meets UL, CSA and CE standards Meets UL, CSA and CE standards

See the whole picture

Integrated Diagnostics Imaging platform for Glaucoma

Glaucoma management is evolving to require a new diagnostic environment to support your clinical assessment when and where you need it.

The Integrated Diagnostics Imaging platform delivers information critical to understanding and managing your patients by offering connection to multi-modality data sets. The combined analysis of HFA3 and CIRRUS™ HD-OCT lets you observe, identify and evaluate structural and functional changes earlier, for better glaucoma management.

ZEISS Integrated Diagnostic Imaging - Glaucoma

Models: HFA3 Humphrey Field Analyzer, HFA3, Humphrey Field Analyzer, Field Analyzer, Analyzer

File Info : application/pdf, 10 Pages, 1,010.76KB

PDF preview unavailable. Download the PDF instead.

ZEISS-HFA3-Brochure-en-OUS-31-020-0016I

References

Adobe PDF Library 15.0

Related Documents

Preview ZEISS Humphrey Field Analyzer 3: Advancing Clinical Perimetry Efficiency
Explore the ZEISS Humphrey Field Analyzer 3 (HFA3), a state-of-the-art perimetry device designed to enhance glaucoma diagnosis and management. Learn about its advanced features like Guided Progression Analysis (GPA), SITA strategies for faster testing, robust data security, and seamless integration into the ZEISS Glaucoma Workflow.
Preview Cirrus HD-OCT: Understanding Your Reports
A comprehensive guide to interpreting Cirrus HD-OCT analysis reports, covering RNFL, ONH, GPA, and Macular Thickness analyses for accurate clinical assessment.
Preview Humphrey Field Analyzer II-i Series Service Manual | Carl Zeiss Meditec
Detailed service manual for the Carl Zeiss Meditec Humphrey Field Analyzer II-i series (HFA II-i). Covers troubleshooting, maintenance, calibration, parts removal, and replacement procedures for models 720-i, 740-i, 745-i, and 750-i, essential for field service engineers.
Preview ZEISS Cataract Workflow: Seamless Integration for Ophthalmic Surgery
Explore the ZEISS Cataract Workflow, a comprehensive solution connecting devices, data, and applications for seamless integration from patient assessment to surgical treatment and follow-up in ophthalmology.
Preview ZEISS Sigma Family: High-End Nano-Analysis with Field Emission SEMs
Explore the ZEISS Sigma Family of Field Emission Scanning Electron Microscopes (FE-SEMs) for high-quality imaging and advanced analytical microscopy. Discover features for reliable, high-end nano-analysis, intuitive workflows, and versatile applications across materials science, life sciences, geosciences, and industry.
Preview ZEISS CALLISTO eye 3.6: Quick Guide to Reference Image Matching
A comprehensive quick guide for ZEISS CALLISTO eye 3.6, detailing the process of matching the reference image for accurate toric IOL alignment. Learn about image capture, microscope requirements, patient data import, and alignment procedures.
Preview ZEISS Smartzoom 5: Digital Light Microscope for Guided Inspection
Explore the ZEISS Smartzoom 5, a digital light microscope designed for guided inspection. Discover its smart design, workflow, and connectivity features, along with its applications in various industries, technical specifications, and service options.
Preview ZEISS ARAMIS: Advanced Optical 3D Measurement for Strain and Deformation Analysis
Explore the ZEISS ARAMIS system for precise, non-contact optical 3D measurement of strain, deformation, and displacement. Applications in aerospace, automotive, electronics, and medical technology, offering full-field and point-based analysis.