Chamberlain Wall Mount Garage Door Opener

Model RJO20

For Residential Use

Install On Sectional Doors With Torsion Assemblies Only

This product is NOT intended for use on low headroom tracks with outside pickup drum or garage doors utilizing extension springs. For advanced or customized adjustments, door springs, and/or track configurations, contact a trained door systems technician.

  • Please read this manual and the enclosed safety materials carefully!
  • Fasten the manual near the garage door after installation.
  • The door WILL NOT CLOSE unless the Protector System® and cable tension monitor are connected and properly aligned.
  • Periodic checks of the garage door opener are required to ensure safe operation.
  • This garage door opener is ONLY compatible with myQ® accessories.
  • The model number label is located behind the hinged door of your opener.

The Chamberlain Group, Inc.
300 Windsor Drive
Oak Brook, IL 60523

UL® LISTED

Preparation

Safety Symbol and Signal Word Review

This garage door opener has been designed and tested to offer safe service provided it is installed, operated, maintained, and tested in strict accordance with the instructions and warnings contained in this manual.

WARNING (Mechanical): When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.

WARNING (Electrical): When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully.

CAUTION: When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully.

UNATTENDED OPERATION

The Timer-to-Close (TTC) feature, the myQ® Smartphone Control app and myQ® Garage Door are examples of unattended close and are to be used ONLY with sectional doors. Any device or feature that allows the door to close without being in the line of sight of the door is considered unattended close.

WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Glossary

Here are some basic terms you may encounter as you prepare and install your garage door opener.

Term Definition
Bearing Plate Acts as a support for the torsion bar. The bearing and mounting plate are typically located above the garage door.
Cable Tension Monitor The cable tension monitor detects any slack in the garage door cables. Failure to properly install the cable tension monitor may cause the cables to be thrown and may result in a hazardous situation. (Not shown below)
Door Seal The door seal is located at the bottom of the door and helps to keep outdoor elements from entering the garage.
Drum Drums are round, grooved spools on the torsion bar that keep door cables orderly.
Extension Springs Extension springs are NOT compatible with this opener. Extension springs are typically mounted along the horizontal section of the track and extend from the front of the door opening to the back hang. The springs are intended to make a door lighter so you can easily open and close the door by hand.
High Lift Sectional Door A type of garage door constructed with multiple panels that slide along a track inside the garage. The track runs vertically up the wall beyond the top of the door opening several inches before encountering the curve in the track. The extended distance above the top of the garage door determines the amount of a high lift.
Roller Small wheels which allow the door to move up and down the track.
Safety Reversing Sensor The safety reversing sensors are a set of sensor eyes that detect obstructions in the path of the garage door. If an obstruction is found, the sensors tell the door to reverse direction. (Not shown below)
Torsion Springs A torsion spring is a type of spring that counter balances the garage door. The torsion spring is located above the door on the torsion bar. The springs are intended to make a door lighter so you can easily open and close the door by hand. Consult a trained door systems technician if you need the springs adjusted or replaced.
Torsion Bar A torsion bar is a horizontal metal bar mounted above the garage door. The torsion springs are located on the torsion bar. Most torsion bars are hollow, while some are solid. Some solid torsion bars may have a groove called a keyway that runs the length of the bar.

Diagram: A side view illustration shows a garage door system with labels for Track, Drum, Torsion Springs, Torsion Bar, Roller, Hinge, Door Seal, Bearing Plate, and Electrical outlet. The floor is indicated at the bottom.

Is Your Garage Ready?

Use this check list to see if your garage is compatible with the garage door opener requirements. Note that you can install the garage door opener on either the left or the right side of the garage door.

IMPORTANT: Your garage MUST meet the following requirements to install this opener to ensure safe and proper operation. If your door does not meet these criteria, you must choose a different model of operator. If your torsion bar, power source and/or drums do not meet the requirements, contact a trained door systems technician.

REQUIREMENTS CHECK LIST

Sectional garage door:

  • Standard sectional door up to 14 feet (4.3 m) high, but only up to 180 sq. ft. (16.7 sq. m).
  • Standard sectional doors up to 18 feet (5.5 m) wide, but only up to 180 sq. ft. (16.7 sq. m)
  • Standard sectional high lift door (up to 54 inches (137.2 cm) of high lift)
  • Any gap between the floor and the bottom of the door must not exceed 1/4 inch (6 mm). Otherwise, the safety reversal system may not work properly.

Torsion bar and torsion springs:

  • Torsion bar is 1 inch (2.5 cm) diameter.
  • Torsion bar must extend at least 1-1/2 inches (3.81 cm) past the bearing plate and be free of damage.
  • Distance between ceiling and center of torsion bar is 3 inches (7.6 cm) or more.
  • Distance between garage wall the torsion bar is mounted on and center of torsion bar is 2-1/2 inches (6.4 cm) or more.
  • A minimum of 8.5 inches (21.6 cm) between the side garage wall (or obstruction) and the end of the torsion bar.

Drums:

  • NOT compatible with reverse wound drums.
  • 4-6 inches (10-15 cm) diameter.
  • 3-3.9 inch (7.6-9.9 cm) diameter drums may be used on doors up to 430 lbs (194kgs).

Power:

  • An electric outlet must be accessible within a 6 foot (1.83 m) diameter of the installation area for the opener.
  • The outlet must be 120 VAC - 60 Hz ONLY. Contact a qualified electrician if you need an outlet installed.

Previously installed garage door opener has been removed completely.

Diagram: An illustration shows a garage wall and ceiling. It indicates the distance between the ceiling and torsion bar (3" / 7.6 cm or more), the torsion bar extending past the bearing plate (at least 1-1/2" / 3.81 cm), an electric outlet within 6 ft (1.83 m) of the opener, and the gap between the floor and the bottom of the door (must not exceed 1/4" / 6 mm). A side view of the torsion bar is also shown, detailing the 8.5 inches (21.6 cm) space from the wall and the 3 inches (7.6 cm) space from the ceiling.

Prepare your Garage Door

WARNING

To prevent possible SERIOUS INJURY or DEATH:

  • ALWAYS call a trained door systems technician if garage door binds, sticks, or is out of balance. An unbalanced garage door may NOT reverse when required.
  • NEVER try to loosen, move or adjust garage door, door springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension.
  • Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement.

CAUTION

To prevent damage to garage door and opener:

  • ALWAYS disable locks BEFORE installing and operating the opener.
  • ONLY operate garage door opener at 120 V, 60 Hz to avoid malfunction and damage.
  1. Uninstall previous garage door opener.
  2. Disable locks.
  3. Remove any ropes connected to the garage door.
  4. Check the seal on the bottom of the door. Any gap between the floor and the bottom of the door must not exceed 1/4 inch (6 mm). Otherwise, the safety reversal system may not work properly.

Complete the test below to make sure the garage door is balanced and is not sticking or binding.

  1. Lift the door 3-4 feet off the ground. Release the door. If balanced, should stay in place, supported entirely by its springs.
  2. Raise and lower the door to check for binding or sticking.

If your door binds, sticks, or is out of balance, contact a trained door systems technician BEFORE you install this opener.

Diagram: An illustration shows a person manually lifting a garage door to test its balance.

Carton Inventory

Save the carton and packing material until the installation and adjustment is complete. The images throughout this manual are for reference only and your product may look different.

Items included in the box:

  • Collar with Set Screws
  • Mounting Bracket
  • Garage Door Opener
  • Cable Tension Monitor with Wire
  • Remote Light with Hardware Bag
  • The Protector System® Safety Reversing Sensors (2) with White & White/Black Wire
  • Power Door Lock with Wire and Connector
  • Safety Reversing Sensor Bracket (2)
  • Lock Template
  • Chamberlain Internet Gateway

NOT SHOWN: Safety labels and literature

ACCESSORIES

  • White & White/Red Wire
  • Door Control (myQ® Control Panel) Model 041A7928-3
  • 3-Button Premium Remote Control Model 953ESTD (1)
  • Remote Control Visor Clip

INCLUDED HARDWARE

  • Screw #8-32x1" (2)
  • Screw #10-32 (2)
  • Screw 14-10x2" (4)
  • Screw 6-32x1" (pre-wired) (2)
  • Screw 6ABx1-1/4" (Standard installation) (2)
  • Screw 1/4"-20x1/2" (2)
  • Drywall Anchor (screw-in) (2)
  • Wing Nut 1/4"-20 (2)
  • Drywall Anchors (2)
  • Rope
  • Handle
  • Carriage Bolt 1/4"-20x1/2" (2)

REMOTE LIGHT HARDWARE

  • Drywall Anchor (screw-in) (2)
  • Screw #4-20x7/16" (2)
  • Screw #6x1" (2)
  • Hinge clip (1)
  • Latch clip (1)

Overview of Installation

Diagram: A schematic shows the general layout of a garage with the opener mounted on the torsion bar. It illustrates the placement and connection of the Cable Tension Monitor, Door Control Wire, Door Lock Wire, Safety Reversing Sensor Wire, and Remote Light. The Safety Reversing Sensors are shown mounted on the garage door tracks.

ADDITIONAL ITEMS YOU MAY NEED FOR THE INSTALLATION:

  • Wood blocks and/or shimming material. Used to mount the cable tension monitor.
  • Fastening hardware.
  • Alternate floor mounting of the safety reversing sensor will require hardware not provided.
  • Extension brackets (Model 041A5281-1) or wood blocks and shimming material. Used to position the garage door opener during installation and for testing the safety reversing sensors if installed on the wall or floor.

Installation

IMPORTANT INSTALLATION INSTRUCTIONS

WARNING

To reduce the risk of SEVERE INJURY or DEATH:

  1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS.
  2. Install garage door opener ONLY on properly balanced and lubricated door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
  3. ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing garage door opener.
  4. Disable ALL locks and remove ALL ropes connected to door BEFORE installing garage door opener to avoid entanglement.
  5. Where possible, install the door operator 7 feet or more above the floor.
  6. Mount the emergency release within reach, but at least 6 feet (1.83 m) above the floor and avoiding contact with vehicles to avoid accidental release.
  7. NEVER connect garage door opener to power source until instructed to do so.
  8. NEVER wear watches, rings or loose clothing while installing or servicing the garage door opener. They could be caught in door or operator mechanisms.
  9. Install wall-mounted door control:
    • within sight of the door.
    • out of reach of small children at a minimum height of 5 feet (1.5 m) above floors, landings, steps or any other adjacent walking surface.
    • away from ALL moving parts of the door.
  10. Install the Entrapment Warning Placard next to the door control in a prominent location.
  11. Place emergency release/safety reverse test label in plain view on inside of door.
  12. Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on the floor.

Tools You Will Need

During assembly, installation and adjustment of the garage door opener, you will need these tools:

Tools: Stepladder, Drill (with 5/32", 3/16", 5/16", and 3/4" Drill Bits), Tape Measure, Pliers, Wire Cutters, Pencil, Screwdriver, Wire Strippers, Claw Hammer, 3/8" Open End Wrench, Needle Nose Pliers, 1/4", 5/16" and 3/8" Sockets and Wrench with 6" Extension, Level.

1 Attach the Collar to the Garage Door Opener

The garage door opener can be installed on either side of the door; see "Is Your Garage Ready?" on page 4. The illustrations shown are for installation on the left side.

  1. Loosen the preset collar screws with the 3/8" open end wrench.
  2. Slide the collar onto the garage door opener shaft until it stops.
  3. Position the collar so the screws are facing out and accessible when attached to the torsion bar.
  4. Tighten the 2 square head set screws by hand until they contact the torsion bar. Then, use a socket wrench to finish tightening the set screws by turning them 1/4 - 1/2 turn.
  5. Loosely attach slotted side of mounting bracket to the same side of the garage door opener as the collar, using screws provided. NOTE: Do not tighten mounting bracket screws until instructed.

WARNING

To prevent possible SERIOUS INJURY or DEATH, the collar MUST be properly tightened. The door may not reverse correctly or limits may be lost due to collar slip.

Diagram: Shows the motor shaft of the opener with a collar being attached. Close-up views show the set screws and the use of a socket wrench to tighten them onto the torsion bar, and the mounting bracket being attached to the opener.

YOU WILL NEED

  • Collar
  • Screw #10-32 (2)
  • Mounting bracket

2 Position and Mount the Garage Door Opener

  1. Close the garage door completely.
  2. Slide the garage door opener onto the end of the torsion bar. Ensure the collar does NOT touch the bearing plate.
  3. Use a level to align the garage door opener parallel to the door. Verify the mounting bracket installation wall is a solid surface, such as wood, concrete or a door/flag bracket.
  4. IMPORTANT: If installing on drywall, the mounting bracket MUST be attached to a stud.
  5. When the garage door opener is properly aligned, mark the mounting bracket holes. If necessary, tighten collar screws on the torsion bar to hold garage door opener in place while marking holes.
  6. NOTE: The garage door opener does not have to be flush to the wall.

WARNING

To prevent possible SERIOUS INJURY or DEATH:

  • Concrete anchors MUST be used if mounting bracket into masonry.
  • NEVER try to loosen, move or adjust garage door, springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension.
  • ALWAYS call a trained door systems technician if garage door binds, sticks or is out of balance. An unbalanced garage door might NOT reverse when required.
  • Garage door opener MUST be mounted at a right angle to the torsion bar to avoid premature wear on the collar.

Diagram: Shows the opener mounted on the torsion bar, with a minimum 0.25" space between the collar and the bearing plate. The opener is shown parallel to the door, attached via a mounting bracket. A close-up shows the mounting bracket attached to the wall.

YOU WILL NEED

  • Screw 14-10x2" (2)

Installation (continued)

  1. Remove the garage door opener from torsion bar.
  2. Drill 3/16 inch pilot holes at the marked locations. Drill through metal door rail plates if necessary.
  3. Slide the garage door opener back onto the torsion bar until pilot holes align with bracket.
  4. Tighten the 2 square head set screws on the torsion bar. For a hollow torsion bar, tighten screws 3/4 - 1 full turn after making contact with the bar. For a solid shaft torsion bar, tighten screws 1/4 - no more than 1/2 turn after making contact with the shaft. If installing on a keyed torsion bar, DO NOT tighten the screws into the keyway.
  5. Secure the mounting bracket to the wall and to the garage door opener. Use the 14-10x2" screws to secure the mounting bracket to the wall.

NOTE: Due to torsion bars being out-of-round, the operator may wobble during operation. This is normal.

Diagram: Shows the mounting bracket being secured to the wall with screws, and the set screws on the torsion bar being tightened.

3 Attach the Emergency Release Rope and Handle

WARNING

To prevent possible SERIOUS INJURY or DEATH from a falling garage door:

  • If possible, use emergency release handle to disengage door ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
  • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
  1. Thread one end of the rope through the hole in the top of the red handle so “NOTICE” reads right side up. Secure with an overhand knot at least 1 inch (2.5 cm) from the end of the rope to prevent slipping.
  2. Thread the other end of the rope through the loop in the emergency release cable. Adjust rope length so the handle is within reach but is no lower than 6 feet (1.83 m) above the floor, and avoid contact with vehicles to avoid accidental release. Secure with an overhand knot.

NOTE: If it is necessary to cut the rope, heat seal cut rope end with a match or lighter to prevent unraveling.

Diagram: Shows the emergency release cable, overhand knot, and the emergency release handle.

YOU WILL NEED

  • Handle
  • Rope

4 Power Door Lock Location

1. Determine where to install the power door lock.

  • Mount the door lock on the same side as the opener. The third roller from the floor is ideal for most installations.
  • The power door lock MUST be mounted within 10 feet (3.05 m) of garage door opener with approximately a 3 inch (7.6 cm) distance between the center of a door roller and the hole for the power door lock bolt.

Diagram: Shows a garage door track and roller, indicating the maximum distance of 10 feet (3.05 m) from the opener and a 3 inch (7.6 cm) distance from the roller to the lock bolt hole.

5 Install Power Door Lock

  1. Pull down on the manual release to disengage the door and open the door manually.
  2. Clean track surface, and attach lock template to the track.
  3. Drill holes as marked on the template. You may find it useful to pre-drill the holes with a smaller bit before proceeding to larger sizes.
  4. Fasten power door lock to the outside of the garage door track with 1/4"-20x1/2" screws provided.
  5. Run wire up wall to garage door opener. Use insulated staples to secure wire in several places.
  6. Insert wire through the bottom of the garage door opener and plug the connector into the garage door opener.

Diagram: Illustrates the steps for installing the power door lock, including drilling holes, attaching the lock, and running the wire.

YOU WILL NEED

  • Screw 1/4"-20x1/2" (2)

6 Position the Cable Tension Monitor (Required)

The cable tension monitor detects any slack in the garage door cables. When slack is detected, the garage door opener stops the door from closing, and reverses the door to stay open. The cable tension monitor MUST be connected and properly installed BEFORE the garage door opener will move in the down direction.

The cable tension monitor must be installed on the same side as the garage door opener. Factory default is configured for left-side installation.

  1. Determine if the cable tension monitor will be installed on the left or right side of the door.
  2. For left-side installation, skip to Step 3. For right-side installation ONLY, remove the c-clip from the roller shaft, move the roller to the other side, and reinstall the c-clip.
  3. Make sure the door cable is approximately 3/4" (19 mm) from the mounting surface.
  4. Position the cable tension monitor 2" to 6" (5-15 cm) from the drum, and over a wood support surface. Shim or add wood block if needed. The cable tension monitor MUST be flush with the mounting surface. Cable tension monitor roller must be free from obstructions.

NOTE: No obstructions should exist that prevent the cable tension monitor from closing completely when slack is detected.

Diagram: Shows the cable tension monitor positioned on the wall near the drum, with the cable passing through its roller. It indicates the recommended distance from the drum (2" to 6") and the cable position (approx. 3/4"). It also shows the option of using a shim.

7 Attach the Cable Tension Monitor

  1. Mark and drill 3/16 inch pilot holes for screws. If the cable tension monitor cannot be mounted into wood, it can be mounted into 1/2 inch (1 cm) or greater drywall using the drywall anchors (2) and the #8 screws (2) provided in the hardware bag.
  2. Attach the cable tension monitor to the wall using the hardware provided. Check that the roller is on top of the cable.
  3. Run wire to garage door opener. Securely affix wire to wall and ceiling. Secure any additional wire away from the moving parts of the door.
  4. Connect wire to the green quick-connect terminals on the garage door opener.

NOTE: Cable must have tension through entire door travel. Check there is no slack in cable on opposite side of garage door during normal operation. If slack occurs during door travel, contact a trained door systems technician.

Diagram: Shows the cable tension monitor mounted on the wall, with the cable passing through it. The wire is shown running to the garage door opener, with a close-up of the quick-connect terminals (WHT/GRN) on the opener.

YOU WILL NEED

  • Screw 14-10x2" (2)
  • Drywall Anchor (screw-in) (2)
  • Screws #8-32x1" (2)

8 Install the Door Control (myQ® Control Panel)

Install door control within sight of garage door, out of reach of small children at a minimum height of 5 feet (1.5 m) above floors, landings, steps or any other adjacent walking surface, and away from ALL moving parts of door.

For gang box installations it is not necessary to drill holes or install the drywall anchors. Use the existing holes in the gang box.

NOTE: Due to power consumption, this door control (Model 041A7928-3) cannot be used in conjunction with another wired door control connected to your garage door opener. If an additional door control is needed, the wireless door control model 041A7773-1 can be programmed to the door control (Model 041A7928-3).

  1. Strip 7/16" (11 mm) of insulation from one end of the wire and separate the wires.
  2. Connect wires to the door control. Make sure the polarity is correct.
    • Red wire to the RED terminal.
    • White wire to the WHT terminal.
  3. Mark the location of the bottom mounting hole and drill a 5/32" (4 mm) hole.
  4. Install the bottom screw, allowing 1/8" (3 mm) to protrude from the wall.
  5. Position the bottom hole of the door control over the screw and slide down into place.
  6. Lift the push bar up and mark the top hole.
  7. Remove the door control from the wall and drill a 5/32" (4 mm) hole for the top screw.
  8. Position the bottom hole of the door control over the screw and slide down into place. Attach the top screw.
  9. Run the white and red/white wire from the door control to the garage door opener. Attach the wire to the wall and ceiling with the staples (not applicable for gang box or pre-wired installations).
  10. Strip 7/16" (11 mm) of insulation from the end of the wire near the garage door opener. Connect wire to the quick-connect terminals on the garage door opener: white to white and white/red to red.
  11. Fasten the warning placard to the wall next to the door control.

NOTE: DO NOT connect the power and operate the garage door opener at this time. The door will travel to the full open position but will not return to the close position until the safety reversing sensors are connected and properly aligned. See page 16.

WARNING

To prevent possible SERIOUS INJURY or DEATH from electrocution:

  • Be sure power is NOT connected BEFORE installing door control.
  • Connect ONLY to 7-28 VOLT low voltage wires.

To prevent possible SERIOUS INJURY or DEATH from a closing garage door:

  • Install door control within sight of garage door, out of reach of small children at a minimum height of 5 feet (1.5 m) above floors, landings, steps or any other adjacent walking surface, and away from ALL moving parts of door.
  • NEVER permit children to operate or play with door control push buttons or remote control transmitters.
  • Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
  • ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.

Diagram: Shows the door control panel, its mounting holes, and wiring connections to the opener. It also shows the wire stripping and connection points.

YOU WILL NEED

  • Screw 6ABx1-1/4" (Standard installation) (2)
  • Drywall Anchors (2)
  • Screw 6-32x1" (pre-wired) (2)

9 Install Remote Light

The remote light (garage door opener light) is designed to plug directly into a standard 120V outlet. Select an appropriate location on the ceiling to mount the light within 6 feet (1.83 m) of an electrical outlet so that the cord and light are away from moving parts.

  1. Install the hinge and latch clips. Clips slide in between the metal plate and the plastic housing on each side of the light base.
  2. Install screws into the ceiling leaving 1/8 inch (3 mm) of the thread exposed.
  3. NOTE: If installing light on drywall and a ceiling joist cannot be located, use drywall anchors provided. No pilot hole is required for drywall anchors.
  4. Wind any excess cord around cord retainer on the top side of the light base.
  5. Install the light base by pushing onto the screws and turning the base clockwise to lock the light in place.
  6. Install two Type A19 incandescent or compact fluorescent bulbs (100 watt maximum per bulb, 200 watts total).
  7. NOTE: Do not use LED bulbs as they may reduce the range or performance of your remote control(s).
  8. Install the light lens by hooking one end of the lens over the hinge and pressing up on the other end to latch into place.
  9. Plug in the light to outlet.
  10. NOTE: Light will not operate until the garage door opener is activated. Multiple openers in the same garage may cause interference between lights. Program all lights to one opener to avoid interference.

WARNING

To reduce the risk of SEVERE INJURY or DEATH:

  • This portable luminaire has a polarized plug (one blade is wider than the other) as a feature to reduce the risk of electric shock.
  • This plug will fit in a polarized outlet ONLY one way.
  • If the plug does not fit fully in the outlet, reverse the plug.
  • If it still does not fit, contact a qualified electrician.
  • NEVER use with an extension cord unless plug can be fully inserted.
  • DO NOT alter the plug.
  • Light is intended for ceiling mount and indoor applications ONLY.

CAUTION

To prevent possible OVERHEATING of the end panel or light socket:

  • DO NOT use short neck or specialty light bulbs.
  • DO NOT use halogen bulbs. Use ONLY incandescent.
  • DO NOT use bulbs larger than 100W.
  • ONLY use A19 size bulbs.

To provide an adequate visual alert, the garage door opener light bulb MUST be a minimum of 40 Watt (or equivalent).

Diagram: Shows the remote light assembly, including the light base, hinge clip, latch clip, cord retainer, wall anchor, and light lens. It also shows the installation of Type A19 bulbs and the connection to a power outlet.

HARDWARE

  • Drywall Anchor (screw-in) (2)
  • Screw #6x1" (2)
  • Screw #4-20x7/16" (2)

10 Install the Protector System®

The safety reversing sensor must be connected and aligned correctly before the garage door will move in the down direction. This is a required safety device and cannot be disabled.

IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR

When properly connected and aligned, the safety reversing sensor will detect an obstacle in the path of its electronic beam. The sending sensor (with an amber indicator light) transmits an invisible light beam to the receiving sensor (with a green indicator light). If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position, and the opener lights will flash 10 times. If the door is already open, it will not close.

WARNING

Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor.

To prevent SERIOUS INJURY or DEATH from a closing garage door:

  • Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled.
  • Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.

Diagram: Shows the garage door with two safety reversing sensors mounted on the tracks, facing each other. The invisible light beam path is indicated. The sensors are shown no higher than 6" (15 cm) above the floor.

INSTALLING THE BRACKETS

The brackets house the safety reversing sensors in a fixed, secure position so the safety reversing sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. Be sure power to the opener is disconnected.

Choose one of the following installations.

OPTION A: Track Installation (Recommended)

  1. Slip the curved arms over the rounded edge of each door track, with the curved arms facing the door, and make sure brackets measure no higher than 6" (15 cm) above the floor.
  2. Snap bracket into place against the side of the track. It should lie flush, with the lip hugging the back edge of the track, as shown.

If your door track will not support the bracket securely, see Option B: Wall Installation.

Diagram: Shows a safety reversing sensor bracket clipped onto a garage door track.

OPTION B: Wall Installation

  1. Place the bracket against the wall with curved arms facing the door. Be sure there is enough clearance for the sensor beam to be unobstructed.
  2. If additional depth is needed, an extension bracket (Model 041A5281-1) or wood blocks can be used. See Accessories section.
  3. Use bracket mounting holes as a template to locate and drill (2) 3/16" diameter pilot holes on the wall at each side of the door, no higher than 6" (15 cm) above the floor.
  4. Attach brackets to wall with lag screws (not provided).

If using extension brackets or wood blocks, adjust right and left assemblies to the same distance out from the mounting surface. Make sure all door hardware obstructions are cleared.

If Option B will not work, see Option C: Floor Installation.

Diagram: Shows a safety reversing sensor bracket mounted on a wall, with an optional extension bracket or wood block.

OPTION C: Floor Installation

  1. Use wood blocks or extension brackets (see Accessories) to elevate sensor brackets so the lenses will be no higher than 6" (15 cm) above the floor.
  2. Carefully measure and place right and left assemblies at the same distance out from the wall. Be sure all door hardware obstructions are cleared.
  3. Fasten to the floor with concrete anchors as shown.

Diagram: Shows safety reversing sensor brackets mounted on wood blocks attached to the floor.

MOUNTING THE SAFETY REVERSING SENSORS

  1. Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor.
  2. Use wing nuts to fasten safety reversing sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension.
  3. Finger tighten the wing nuts.

Diagram: Shows the safety reversing sensor being attached to its bracket using a carriage bolt and wing nut.

HARDWARE

  • Carriage Bolt 1/4"-20x1/2" (2)
  • Wing Nut 1/4"-20 (2)

WIRE THE SAFETY REVERSING SENSORS

  1. Run the wire from both sensors to the garage door opener. Securely affix the wire to the wall and ceiling with staples (not provided).
  2. Strip 7/16 inch (11 mm) of insulation from each set of wires. Separate white from the black wires. Twist the white wires together. Twist the white/black wires together.
  3. On the garage door opener, push the tab with a screwdriver tip to insert the white wires into the white terminal and the white/black wires into the grey terminal.

Diagram: Shows the wiring connection to the garage door opener, with a close-up of stripping the wire and connecting to the terminals (WHT to white, WHT/BLK to grey).

11 Connect Power

To avoid installation difficulties, do not run the garage door opener at this time.

To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet. If the plug doesn't fit into the outlet you have, contact a qualified electrician to install the proper outlet.

There are two options for connecting power:

OPTION A: TYPICAL WIRING

  1. Plug in the garage door opener into a grounded outlet.
  2. DO NOT run garage door opener at this time.

Diagram: Shows a correct (right) and incorrect (wrong) way to plug into an outlet.

OPTION B: PERMANENT WIRING CONNECTION

If permanent wiring is required by your local code, refer to the following procedure.

  1. To make a permanent connection through the 7/8 inch hole in the back of the garage door opener (according to local code):
  2. Be sure power is NOT connected to the opener, and disconnect power to circuit.
  3. Remove the garage door opener from the torsion bar, remove cover screws and set the cover aside.
  4. Cut the line cord 6" (15.2 cm) above the strain relief.
  5. Squeeze the strain relief and push into garage door opener, then remove the strain relief from the line cord.
  6. Install a 90° conduit (not provided) or flex cable adapter (not provided) to the 7/8" hole. Reinstall garage door opener to torsion bar.
  7. Run wires through conduit, cut to proper length and strip insulation.
  8. Strip 1/2" (1.3 cm) of insulation from the existing black, white and green wires.
  9. Connect the line to the black wire and neutral to the white wire with wire nuts (not provided). Connect ground wire to the green ground screw.
  10. Properly secure wires under plastic ties so that they do not come into contact with moving parts.
  11. Reinstall cover.

WARNING

To prevent possible SERIOUS INJURY or DEATH from electrocution or fire:

  • Be sure power is NOT connected to the opener, and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection.
  • Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes.
  • NEVER use an extension cord, 2-wire adapter or change plug in ANY way to make it fit outlet. Be sure the opener is grounded.

Diagram: Shows the back view of the opener with connections for power cord, ground wire, and conduit. It indicates the green, black, and white wires.

12 Align the safety reversing sensors

The door will not close if the sensors have not been installed and aligned correctly. The LEDs in both sensors must be glowing steady, which indicates they are powered and aligned correctly. The sending sensor (with an amber LED) transmits an invisible light beam to the receiving sensor (with a green LED). If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to the full open position, and the remote lights will flash 10 times. If the door is already open, it will not close.

TO ALIGN SENSORS:

The sensors can be aligned by loosening the wing nuts, aligning the sensors, and tightening the wing nuts.

Diagram: Shows the sending sensor with an amber LED and the receiving sensor with a green LED, with the invisible light beam between them. It also shows a close-up of the sensors and their alignment.

If the LEDs are not glowing steadily:

  • Check that both sensors are installed inside the garage, one on either side of the door.
  • Check that sensors are facing each other with the lenses aligned and the receiving sensor light does not receive direct sunlight.
  • Check that sensors have the same measurement, no higher than 6” above the floor.

Amber LED is not lit:

  • Check there is power to the garage door opener.
  • Check the sensor wire is not shorted/broken.
  • Check the sensor has been wired correctly: white wires to white terminal and white/black wires to grey terminal.

Green LED is not lit:

  • Check that the sensor wire is not shorted/broken.
  • Check that the sensors are aligned.

ENSURE THE DOOR CONTROL IS WIRED CORRECTLY

The yellow Command LED and the red Learn LED on the door control will blink quickly for up to 5 minutes as the door control recharges. When the door control is operational, the yellow Command LED will glow steadily.

Adjustment

1 Program the Travel Limits

Travel limits regulate the points at which the door will stop when moving up or down. Adjust the position of the door by using the black and yellow buttons. Black moves the door UP (open) and yellow moves the door DOWN (close).

NOTE: The yellow command LED and the red learn LED will blink quickly for up to 5 minutes as the control panel recharges. When the control panel is operational, the yellow command LED will glow steadily.

SETTING THE UP POSITION:

  1. Starting with door down, press and hold the black button until the LED starts flashing slowly, then release.
  2. Push and hold the black button until the door reaches the desired UP (open) position.
  3. Push the door control or programmed remote control. This sets the UP (open) limit and begins closing the door.
  4. Quickly press and release either the black or yellow button to stop the door.

NOTE: Make sure the door opens high enough for your vehicle.

WARNING

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

  • NEVER learn forces or limits when door is binding or sticking. Repair door first.
  • Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
  • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on floor.

CAUTION

To prevent damage to vehicles, be sure fully open door provides adequate clearance.

IMPORTANT: As you perform this task, watch the door for binding, sticking, or swaying. Contact a door systems technician to address these issues if they occur.

SETTING THE DOWN POSITION:

  1. Push and hold the yellow button until the door reaches the desired DOWN (closed) position.
  2. Once the door is closed, if there appears to be too much pressure on the door, you may toggle the door back and forth using the black and yellow buttons to reach the desired closed position.
  3. Push the door control or programmed remote control. This sets the DOWN (close) limit and the door should open.

Diagram: Shows the control panel buttons (black and yellow) and their use in setting the up and down travel limits. It also shows the door moving up and down, and the use of a 1-1/2" board for testing.

Proceed to Enter Force Adjustment Mode.

2 Enter Force Adjustment Mode

The force setting measures the amount of force required to open and close the door.

  1. Push the yellow button twice to enter into the Force Adjustment Mode. The LED will flash quickly.
  2. Push the door control or programmed remote control. The door will close (DOWN).
  3. Push the door control or programmed remote control again. The door will open (UP).
  4. Push the door control or programmed remote control a third time to close the door (DOWN).

The LED will stop flashing when the force has been programmed. The door must travel through a complete cycle, up and down, in order for the force to be set properly. If the garage door opener cannot open and close the door fully, inspect the door to ensure that it is balanced properly and is not sticking or binding. If the door is not stopping exactly where you would like it, repeat Program the Travel Limits.

WARNING

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

  • NEVER learn forces or limits when door is binding or sticking. Repair door first.
  • Too much force on garage door will interfere with proper operation of safety reversal system.
  • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or 2x4 laid flat) on floor.

Diagram: Shows the control panel buttons and the sequence of presses to enter force adjustment mode. It also shows the door cycling up and down.

3 Test the Safety Reversal System

TEST

  1. With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2x4 laid flat) on the floor, centered under the garage door.
  2. Operate the door in the down direction. The door must reverse on striking the obstruction. Upon successful safety reversal test proceed to Adjustment Step 4.

ADJUST

If the door stops on the obstruction, it is not traveling far enough in the down direction. Complete Adjustment Steps 1 and 2 Program the Travel Limits and Set the Force. Repeat the test.

When the door reverses on the 1-1/2 inch (3.8 cm) board (or 2x4 laid flat), remove the obstruction and run the garage door opener through 3 or 4 complete travel cycles to test adjustment.

If the garage door opener continues to fail the safety reverse test, call for a trained door systems technician.

IMPORTANT SAFETY CHECK:

Test the safety reversal system after:

  • Each adjustment of limits, or force controls.
  • Any repair to or adjustment of the garage door (including springs and hardware).
  • Any repair to or buckling of the garage floor.
  • Any repair to or adjustment of the opener.

WARNING

Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

  • Safety reversal system MUST be tested every month.
  • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
  • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or 2x4 laid flat) on the floor.

Diagram: Shows a garage door and a 1-1/2" board placed on the floor as an obstruction for testing the safety reversal system.

4 Test the Protector System®

  1. Press the remote control push button to open the door.
  2. Place the opener carton in the path of the door.
  3. Press the remote control push button to close the door. The door will not move more than an inch (2.5 cm), and the opener lights will flash.

The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed).

If the garage door opener closes the door when the safety reversing sensor is obstructed, do not operate the door. Call for a trained door systems technician.

WARNING

Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.

Diagram: Shows the safety reversing sensors and indicates that the opener carton should be placed in the path of the door for testing.

5 Test the Power Door Lock

  1. With the door fully closed, check to ensure that the power lock bolt is visible protruding through the track.
  2. Press the button on the remote control to open the garage door. The power door lock should retract before the door begins to move.
  3. Press the button on the remote control to close the garage door. When the door reaches the fully closed position, the power door lock should automatically activate to secure the door.

NOTE: The power door lock can be manually released by sliding the manual release handle to the open position. However, if the power door lock does not function, contact Chamberlain for a replacement.

WARNING

To prevent possible SERIOUS INJURY or DEATH from a falling garage door:

  • If possible, use emergency release handle to disengage door ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
  • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.

Diagram: Shows the power door lock mechanism, indicating the lock bolt and manual release.

6 Test the Emergency Release

OPEN THE DOOR MANUALLY:

  1. Close the garage door. Slide the manual release handle on power door lock to open before proceeding.
  2. Pull down on the emergency release handle until you hear a click.
  3. Lift the door manually.

RECONNECT THE DOOR TO THE GARAGE DOOR OPENER:

  1. Pull down on the emergency release handle until you hear a click. The door will reconnect on the next UP or DOWN operation.

Diagram: Shows the emergency release handle being pulled down.

7 Test the Cable Tension Monitor

  1. Close the garage door.
  2. Pull down on the emergency release handle until you hear a click.
  3. Press on the front of the cable tension monitor, you should hear a click.
  4. Reconnect the garage to the garage door opener. If there is no click, the roller may be hitting the jamb and not allowing the switch to detect slack in the cable. Make sure the cable tension monitor is mounted flush with the wall and the roller is free from any obstructions.

When the cable tension monitor has been activated, the LED on the garage door opener will blink 9 times.

Diagram: Shows the cable tension monitor and its roller, and the LED indicator on the opener.

Operation

IMPORTANT SAFETY INSTRUCTIONS

WARNING

To reduce the risk of SEVERE INJURY or DEATH:

  1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
  2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with door control push buttons or remote controls.
  3. ONLY activate door when it can be seen clearly, it is properly adjusted and there are no obstructions to door travel.
  4. ALWAYS keep garage door in sight and away from people and objects until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
  5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPENED DOOR.
  6. If possible, use emergency release handle to disengage door ONLY when door is CLOSED. Use caution when using this release with the door open. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly and increasing the risk of SEVERE INJURY or DEATH.
  7. NEVER use emergency release handle unless doorway is clear of persons and obstructions.
  8. After ANY adjustments are made, the safety reversal system MUST be tested. Failure to adjust the garage door opener properly may cause SEVERE INJURY or DEATH.
  9. Safety reversal system MUST be tested every month. Door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on the floor. Failure to adjust the garage door opener properly may cause SEVERE INJURY or DEATH.
  10. ALWAYS KEEP DOOR PROPERLY BALANCED (see page 4). An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
  11. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under EXTREME tension, MUST be made by a trained door systems technician.
  12. To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric and battery power BEFORE performing ANY service or maintenance.
  13. This operator system is equipped with an unattended operation feature. The door could move unexpectedly. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
  14. SAVE THESE INSTRUCTIONS.

Using Your Garage Door Opener

Your garage door opener has already been programmed at the factory to operate with your remote control, which changes with each use, randomly accessing over 100 billion new codes. When programmed to the Chamberlain® Internet Gateway you can monitor and control your garage door from your smartphone.

You may program the myQ® control panel with up to:

  • 12 remote controls
  • 2 keypads
  • a combination of 16 myQ® accessories

See Accessories page 38.

The garage door opener can be activated through a wall-mounted door control, remote control, wireless keypad or myQ® accessory. When the door is closed and the garage door opener is activated the door will open. If the door senses an obstruction or is interrupted while opening, the door will stop. When the door is in any position other than closed and unattended operation is activated, the door will close. If the garage door opener senses an obstruction while closing, the door will reverse. If the obstruction interrupts the sensor beam, the garage door opener lights will blink 10 times. However, you can close the door if you hold the button on the door control or keypad until the door is fully closed. The safety reversing sensors do not affect the opening cycle. The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.

The garage door opener lights will turn on when the garage door opener is activated. They will turn off automatically after 4-1/2 minutes or provide constant light when the Light feature on the myQ® Control Panel is activated. Bulb size is A19. Bulb power is 100 watts maximum.

Light feature: Lights will also turn on when someone walks through the open garage door. With a myQ® Control Panel, this feature may be turned off as follows: With the garage door opener lights off, press and hold the light button for 10 seconds, until the light goes on, then off again. To restore this feature, start with the garage door opener lights on, then press and hold the light button for 10 seconds until the light goes off, then on again.

TIMER-TO-CLOSE (TTC)

The TTC feature automatically closes the door after a specified time period that can be adjusted using a TTC enabled door control. Prior to and during the door closing, the garage door opener lights will flash and the garage door opener will beep.

Using the Door Control (myQ® Control Panel)

NOTE: Due to power consumption, this door control (Model 041A7928-3) cannot be used in conjunction with another wired door control connected to your garage door opener. If an additional door control is needed, the wireless door control model 041A7773-1 can be programmed to the door control (Model 041A7928-3). To program the 041A7773-1 to the myQ® Control Panel, follow the remote control programming steps.

Diagram: Shows the myQ® Control Panel with labels for Push Bar, TTC LEDs (1, 5, 10 Minute), LIGHT Button, Motion Sensor, and HOLD OPEN Button.

FEATURE HOW TO
PUSH BAR Press the push bar to open/close the door.
LOCK Activate: Press and hold the LOCK button for 2 seconds. The command LED will flash as long as the lock feature is activated and your handheld remote control will not operate your door at this time.
Deactivate: Press and hold the LOCK button again for 2 seconds. The command LED will stop flashing and normal operation will resume.
MOTION SENSOR Activate/Deactivate: Slide the motion sensor switch ON or OFF.
TIMER-TO-CLOSE (TTC) Activate: Press and hold the ON button until one of the TTC LEDs light up. Then press the ON button again to cycle through the time interval options (the corresponding TTC LED will light for each time interval). The garage door opener light bulbs will blink as confirmation.
Deactivate: Press and hold the OFF button until all TTC LEDs turn off and a beep is heard from the control panel.
To suspend the TTC: To suspend the TTC and temporarily hold the door open, press and release the HOLD OPEN button (the HOLD OPEN LED will turn solid). The TTC will remain suspended until the HOLD OPEN button is pressed again or the garage door opener is activated from another device (door control, remote control, keypad, etc.).

Using the Door Control (continued)

FEATURE HOW TO
LIGHTS: Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned on they will stay on until the LIGHT button is pressed again, or until the garage door opener is activated. Once the garage door opener is activated the lights will turn off after the specified period of time (the factory setting is 4-1/2 minutes). The LIGHT button will not control the lights when the door is in motion.
TO CHANGE THE AMOUNT OF TIME THE REMOTE LIGHTS WILL STAY ON: Press and hold the LOCK button until the garage door opener lights flash. The time interval is indicated by the number of flashes.
NUMBER OF TIMES GARAGE DOOR OPENER LIGHTS FLASH TIME THE GARAGE DOOR OPENER LIGHT STAYS ON
1 1 1/2 Minutes
2 2 1/2 Minutes
3 3 1/2 Minutes
4 4 1/2 Minutes
LIGHT ALERT: ACTIVATE: Start with the garage door opener lights on. Press and hold the LIGHT button until the garage door opener lights turn off, then on again.*
DEACTIVATE: Press and hold the LIGHT button until the garage door opener lights turn on, then off again.*
* Approximately 10 seconds

Using the Remote Control

Press and hold the button down until the door or gate starts to move. The remote control will operate from up to 3 car lengths away on typical installations. Installations and conditions vary, contact an installing dealer for more information.

NOTICE: This device complies with Part 15 of the FCC rules and Industry Canada's license-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device must be installed to ensure a minimum 20 cm (8 in.) distance is maintained between users/bystanders and device. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules and Industry Canada ICES standard. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

Diagram: An illustration shows a person using a remote control to operate a garage door from a car.

Programming

Your hand-held remote control (model 953ESTD) has already programmed to the door control (myQ® Control Panel) at the factory. Below are instructions for programming additional remote controls, keypads, and myQ® enabled accessories to the door control.

NOTE: Use the learn button on the door control to program all accessories. The yellow learn button on the garage door opener will NOT program accessories.

To Add a Remote Control, Keypad, or myQ® Enabled Accessories

REMOTE CONTROL

  1. Press the myQ® Control Panel LEARN button twice, the red learn LED will turn on.
  2. Press the button on the remote control that you wish to operate your garage door.
  3. The garage door opener lights will flash (or two clicks will be heard) when the code has been programmed.

KEYPAD

  1. Press the myQ® Control Panel LEARN button twice, the red learn LED will turn on.
  2. Enter a 4-digit personal identification number (PIN) of your choice on the keypad. Then press the ENTER button.
  3. The garage door opener lights will flash (or two clicks will be heard) when the code has been programmed.

myQ® ENABLED ACCESSORIES

  1. Press the myQ® Control Panel LEARN button twice, the red learn LED will turn on.
  2. Press the LEARN button on the myQ® device.*

Diagram: Shows the myQ® Control Panel with its LEARN button and LEDs. It also shows a keypad with PIN entry and an ENTER button. Diagrams for Model PILCEV, Model 041A7614, and Model WSLCEV are also shown.

*myQ® accessories may be programmed to the Chamberlain® Internet Gateway (Model 828LG) or the myQ® Control Panel.

Model PILCEV - Remote Light Control: Light module can be synchronized with the garage door opener light bulbs.

Model 041A7614 - Garage Door Monitor: Indicates the status of your garage door from inside the home and allows you to close an open garage door from inside the house.

Model WSLCEV - Remote Light Switch: Light module can be synchronized with the garage door opener light bulbs.

Reprogramming Remote Light or Additional Light

Your garage door opener remote light has already been programmed at the factory to operate with your opener. Any additional or replacement remote lights will need to be programmed.

  1. Press the LEARN button on the light until the LED comes ON.
  2. Activate the garage door opener using the hand-held remote, door control, or keypad.
  3. The code has been programmed when the remote light comes on.

HomeLink®

In the rare case the HomeLink system does not program with the Security+ 2.0 Garage door opener, install a repeater kit. Refer to HomeLink instructions below.

HomeLink is the in-vehicle system. The image used is for reference only and your product may look different.

WHEN TO INSTALL A HOMELINK REPEATER KIT

  • All 2006 and older vehicles – A repeater kit is required and must be purchased by the homeowner.
  • All 2007 and newer vehicles – Program the HomeLink according to the vehicle instructions. If after ONE attempt to program the HomeLink to the garage door opener and you are unsuccessful, install a repeater.

HOW TO ORDER

Order the HomeLink repeater kit from an installer or call 1-800-355-3515. To program the HomeLink repeater kit, refer to the instructions provided in the kit or visit: http://www.homelink.com/program.

INSTALLATION QUICK FACTS

  • Only one repeater kit is required per home.
  • Use different HomeLink buttons in vehicle if programming multiple cars, button 1 first car, button 2 second car... etc.
  • HomeLink remote is NOT a garage door opener.
  • If you are using the HomeLink repeater with a garage door opener that has a battery backup system, ensure your original garage door opener remote control is programmed to the garage door opener and place it in your glove box for use in the event of a power outage.
  • The remote included in this repeater kit MUST be kept for future programming - new vehicle, new garage door opener, etc.

Diagram: Shows the HomeLink system in a car, the HomeLink repeater kit, and a car with a garage door opener.

Getting Connected

Internet Gateway

The Internet Gateway gives you control of your garage door from your internet-connected computer or mobile device, letting you use the myQ® app to open and close your door, get alerts, and set schedules from anywhere. In addition, connected smart garage door openers also receive software updates to ensure the opener has the latest operational features. You must have your Internet Gateway set up in the myQ® app to use it with the control panel.

Figure 1: Diagram showing a Router, Power source, and Chamberlain Internet Gateway connected. It indicates the Green LED status.

Before you begin, you will need:

  • Wi-Fi enabled smartphone or tablet
  • Broadband internet connection and router
  • Wi-Fi signal in the garage (2.4 Ghz, 802.11b/g/n required)
  • Password for your home network (router's main account, not guest network)
  • myQ® serial number located on the garage door opener

Connect the Internet Gateway to your router and power. When the green LED on the gateway has stopped blinking and glows steadily, it is connected to the internet.

Setup and Connect Your Gateway and Opener in the myQ® App

  1. Download the myQ® App and set up your account.
  2. Follow the instructions given in the app to find and connect your Internet Gateway.
  3. Next, select the device you wish to add (Garage Door Opener).
  4. Once you select the opener in the app, you have 3 minutes to press the LEARN button two times on the myQ® control panel. The red LEARN LED will turn on. (Figure 2)
  5. When the red LEARN LED turns off, programming is complete. Once the opener is learned and appears in the app device list, name your device (e.g., Garage Door Opener).

NOTE: If you are unable to add the myQ® Control Panel to your Chamberlain Internet Gateway, erase all codes from the door control and try again. Note that you will need to reprogram any accessories you wish to use.

Figure 2: Shows the myQ® Control Panel with the Red Learn LED and LEARN button highlighted.

To Erase All Codes From the Door Control (myQ® Control Panel) Memory

Erase all remote controls and keyless entries:

  1. Press and hold the LEARN button on the control panel until the red learn LED goes out (approximately 6 seconds). All remote control and keypad codes are now erased. Reprogram any compatible accessory you wish to use.

Erase all devices (including myQ® enabled accessories):

  1. Press and hold the LEARN button on the control panel until the red Learn LED goes out (approximately 6 seconds).
  2. Immediately press and hold the LEARN button again until the red Learn LED goes out. All codes are now erased. Reprogram any compatible accessory you wish to use.

Maintenance

Care of Your Garage Door Opener

MAINTENANCE SCHEDULE

Once a Month
  • Manually operate door. If it is unbalanced or binding, call a trained door systems technician.
  • Check to be sure door opens and closes fully. Adjust limits and/or force if necessary (see Adjustment Steps 1 and 2).
  • Repeat the safety reverse test. Make any necessary adjustments (see Adjustment Step 3).
Once a Year
  • Oil door rollers, bearings and hinges. The garage door opener does not require additional lubrication. Do not grease the door tracks.

THE REMOTE CONTROL BATTERY

The 3V CR2032 Lithium battery should produce power for up to 3 years. If the battery is low, the remote control's LED will not flash when the button is pressed.

To replace battery, pry open the case first in the middle (1), then at each side (2 and 3) with the visor clip. Replace the batteries with only 3V CR2032 coin cell batteries. Insert battery positive side up. Dispose of old batteries properly.

Diagram: Shows the remote control, the 3V CR2032 battery, and the visor clip being used to open the remote case.

WARNING

To prevent possible SERIOUS INJURY or DEATH:

  • NEVER allow small children near batteries.
  • If battery is swallowed, immediately notify doctor.

To reduce risk of fire, explosion or chemical burn:

  • Replace ONLY with 3V CR2032 coin batteries.
  • DO NOT recharge, disassemble, heat above 212° F (100° C) or incinerate.

Troubleshooting

Diagnostic Chart

Your garage door opener is programmed with self-diagnostic capabilities. The diagnostic LED will flash a number of times, then pause, signifying it has found a potential issue. Consult Diagnostic Chart below.

Diagram: Shows a garage door opener with a diagnostic LED and a safety reversing sensor.

FLASH SYMPTOM
1 FLASH
OR
2 FLASHES
Safety reversing sensors wire open (broken or disconnected) OR Safety reversing sensors wire shorted or black/white wire reversed
SYMPTOM: One or both of the Indicator lights on the safety sensors do not glow steady.
• Safety reversing sensors are not installed, connected, or wires may be cut. Inspect sensor wires for a disconnected or cut wire.
• There is a short or reversed wire for the safety reversing sensors. Inspect safety sensor wire at all staple and connection points, replace wire or correct as needed.
3 FLASHES Door control or wire shorted
SYMPTOM: The door doesn't activate from the door control.
• Inspect door control/wires for a short (staple in wire), replace as needed.
• Disconnect wires at door control, touch wires together. If garage door opener activates, replace door control.
• If garage door opener does not activate, disconnect door control wires from garage door opener. Momentarily short across red and white terminals with jumper wire. If garage door opener activates, replace door control wires.
4 FLASHES Safety reversing sensors slightly misaligned (dim or flashing LED)
SYMPTOM: Sending indicator light glows steadily, receiving indicator light is dim or flashing.
• Realign receiving sensor, clean lens and secure brackets.
• Verify door track is firmly secured to wall and does not move.
5 FLASHES Motor RPM is not recognized
SYMPTOM: Door travels 2-3 inches and stops.
• Reprogram limits and forces. See Adjustment section.
• If the motor unit continues to travel 2-3 inches, check the travel module connection or replace the travel module.
9 FLASHES Cable tension monitor reversal
SYMPTOM: No movement, motor runs 2-3 seconds.
• Reconnect the emergency release.
• Motor may need to be replaced.
10 FLASHES
11 FLASHES
Limits and forces need reprogramming
SYMPTOM: Door stops and reverses while closing.
• Reprogram limits and forces. See Adjustment section.
12 FLASHES
13 FLASHES
Attempting to compensate
SYMPTOM: Door stops and reverses while closing.
• Reprogram limits and forces. See Adjustment section.
SYMPTOM: Door stops while opening.
• Garage door opener will try to compensate three times before turning to a 10 Flash.

Troubleshooting (continued)

The garage door opener doesn't operate from either the Door Control or the remote control:

  • Does the garage door opener have electric power? Plug a lamp into the outlet. If it doesn't light, check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.)
  • Have you disabled all door locks? Review installation instruction warnings on page 7.
  • Is there a build-up of ice or snow under the door? The door may be frozen to the ground. Remove any restriction.
  • The garage door spring may be broken. Have it replaced (see page 3 for reference).
  • If the yellow command LED does not turn on, reverse the wires connected to the RED and WHT terminals of the control panel. Replace wire if necessary.

The yellow and red LEDs on the Door Control are blinking quickly:

  • The control panel is charging, and may take up to 5 minutes to become operational.

My remote control will not activate the garage door:

  • Verify the lock feature is not activated on the door control.
  • Reprogram the remote control.
  • If the remote control will still not activate the door check the diagnostic codes to ensure the garage door opener is working properly.

The remote control has short range:

  • Change the location of the remote control in your car.
  • Some installations may have shorter range due to a metal door, foil backed insulation, or metal garage siding.

The door doesn't open completely:

  • Check power door lock.
  • Is something obstructing the door? Is it out of balance, or are the springs broken? Remove the obstruction or repair the door.

The door opens but won't close:

  • Check cable tension monitor (see Installation Step 6 on page 13).
  • If the garage door opener lights blink, check the safety reversing sensor (see Installation Step 9 on page 17).
  • If the garage door opener lights don't blink and it is a new installation (see Adjustment Step 2 on page 23). For an existing installation, see below.
  • Repeat the safety reverse test after the adjustment is complete.

The door reverses for no apparent reason and garage door opener lights don't blink:

  • Check cable tension monitor (see Installation Step 6 on page 13).
  • Is something obstructing the door? Pull the emergency release handle. Operate the door manually. If it is unbalanced or binding, call a trained door systems technician.
  • Clear any ice or snow from the garage floor area where the door closes.
  • Review Adjustment Step 2 on page 23.
  • Repeat safety reverse test after adjustments.

My door will not close and the light bulbs blink:

The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.

  • Verify the safety sensors are properly installed, aligned and free of any obstructions.

The garage door opener strains to operate door:

  • The door may be out of balance or the springs may be broken. Close the door and use the emergency release handle to disconnect the door. Open and close the door manually. A properly balanced door will stay in any point of travel while being supported entirely by its springs. If it does not, disconnect the garage door opener and call a trained door systems technician.

Troubleshooting (continued)

The garage door opener motor hums briefly, then won't work:

  • The garage door springs may be broken. See above.
  • If the problem occurs on the first operation of the garage door opener, door may be locked. Disable the power door lock.

The garage door opener won't operate due to power failure:

  • Manually open the power door lock.
  • Use the emergency release handle to disconnect the door. The door can be opened and closed manually. When power is restored, pull manual release a second time.

Door loses limits.

  • Collar not tightened securely. Tighten collar (see Assembly Steps 1 and 2 on pages 9 and 10) and reprogram limits (see Adjustment Step 1 on page 22).

The garage door opener moves when the door is in operation:

  • Some minor movement is normal for this product. If it is excessive the collar will wear prematurely.
  • Check to make sure the torsion bar is not moving left/right excessively.
  • Check to make sure the torsion bar is not visibly moving up and down as it rotates.
  • Check that the opener is mounted at a right angle to the jackshaft. If not, move the position of the mounting bracket.

Power lock makes noise when operating.

  • Call Chamberlain® for replacement power lock.

Automatic Garage Door Opener Safety & Maintenance Guide

Garage Door Opener Safety – An Automatic Decision

A garage door is the largest moving object in the home. An improperly adjusted garage door and opener can exert deadly force when the door closes – which could lead to entrapment of children or adults and subsequent injury or death.

Proper installation, operation, maintenance, and testing of the garage door and automatic opener are necessary to provide a safe, trouble-free system.

Careless operation or allowing children to play with or use garage door opener controls are also dangerous situations that can lead to tragic results. A few simple precautions can protect your family and friends from potential harm.

Please review the safety and maintenance tips in this guide carefully and keep it for reference. Check the operation of your garage door and opener to ensure they function in a safe and trouble-free manner.

Be sure to read all Important Safety Information found in your garage door opener's manual as it provides more details and safety considerations than can be supplied with this guide.

Garage Door Openers are Not Toys

Discuss garage door and opener safety with your children. Explain the danger of being trapped under the door.

Diagram: Illustration showing a person staying away from a moving garage door.

Diagram: Illustration showing children being kept away from remote controls.

Diagram: Illustration showing a wall-mounted push button being installed out of reach of children and away from moving parts.

Diagram: Illustration showing keeping the door in sight until it completely closes.

Routine Maintenance Can Prevent Tragedies

Make monthly inspection and testing of your garage door and opener system a part of your regular routine. Review your owner's manual for both the door and door opener. If you don't have the owner's manuals, contact the manufacturer(s) and request a copy for your specific model(s). Look for the opener model number on the back of the power unit.

WARNING – Springs are under high tension. Only qualified individuals should adjust them.

Visually check the door and installation:

  • Starting with the door in the closed position, use the manual disconnect on the opener to disconnect the door.
  • Look for signs of wear or damage on hinges, rollers, springs, and door panels.
  • These parts may require periodic lubrication. Check the owner's manual for suggested maintenance.
  • If any signs of damage are evident, contact a trained door systems technician for assistance.
  • Verify the photoeye height is no higher than 6" from the garage floor.

Diagram: Shows a hand lubricating a garage door roller.

Test the door for proper operation:

  • Open and close the door manually using handles or suitable gripping points.
  • The door should move freely and without difficulty.
  • The door should balance and stay partially open 3–4 feet above the floor.
  • If you detect any signs of improper operation, contact a trained door systems technician for assistance.

Diagram: Shows a garage door being manually operated and balanced.

Test the opener safety features:

  • Reconnect the opener to the door using the manual disconnect and open the door.
  • Place a 2x4 board flat in the path of the door (1) and try to close it (2). The door should stop when it comes in contact with the 2x4 and then reverse direction.
  • Block the photoelectric sensor by waving an object in front of the sensor and attempt to close the door. The door should not close unless the wall-mounted push button is manually held during operation.
  • If the opener does not perform as described, contact a trained door systems technician for assistance.

Diagram: Shows the safety test with a 2x4 board and the photoelectric sensor being blocked.

DASMA
Door & Access Systems
Manufacturers Association
International

Accessories

G940EV Wireless Keypad:

For use outside of the home to enable access to the garage using a 4-digit PIN. Works with ALL Chamberlain openers from 1993-present. myQ® compatible.

940ESTD Wireless Keypad:

For use outside of the home to enable access to the garage using a 4-digit PIN.

G953EV Remote Control:

Works with ALL Chamberlain openers from 1993-present. myQ® compatible. Includes visor clip.

G956EV Keychain Remote Control:

Works with ALL Chamberlain openers from 1993-present. myQ® compatible. With key ring.

CLLP1 Laser Park Assist:

Laser enables homeowners to precisely park vehicles in the garage.

041A5281-1 Extension Brackets:

(Optional) For safety reversing sensor installation onto the wall or floor.

WSLCEV Remote Light Switch:

Automatically control your lights using your garage door opener, a Security+ 2.0® remote control or a myQ® Internet Gateway. Simply replaces your current wired wall switch.

PILCEV Remote Light Control:

Monitor and control this plug in lamp switch with the myQ® Smartphone App.

041A7614 Garage Door Monitor:

Monitor open/closed status for up to 4 myQ® compatible garage door openers or gate operators and close them from anywhere in the home.

PROVIDED ACCESSORIES

041A7928-3 myQ® Control Panel

G828LG Internet Gateway:

Internet enabled accessory which connects to the computer and allows you to monitor and control garage door openers and lighting accessories enabled by myQ® technology.

041A6287 Remote Light:

Enables homeowner to turn on a work light from their car with their garage door opener remote or from anywhere in their home with an additional Chamberlain® remote.

Diagram: Shows illustrations of various accessories like keypads, remote controls, extension brackets, light switches, and monitors.

Warranty

CHAMBERLAIN® LIMITED WARRANTY

The Chamberlain Group, Inc.® (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defects in materials and/or workmanship for a specific period of time as defined below (the "Warranty Period"). The warranty period commences from the date of purchase.

Parts Motor Accessories
5 years Lifetime 1 year

The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, and maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.

If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-9131, toll free, before dismantling this product. You will be advised of disassembly and shipping instructions when you call. Then send the product or component, pre-paid and insured, as directed to our service center for warranty repair. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller's sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory rebuilt parts at Seller's sole option. [You are responsible for any costs incurred in removing and/or reinstalling the product or any component.]

ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE LIMITED WARRANTY PERIOD SET FORTH ABOVE FOR THE RELATED COMPONENT(S), AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some States and Provinces do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT OF CONSUMABLE ITEMS (E.G., BATTERIES IN REMOTE CONTROL TRANSMITTERS AND LIGHT BULBS), OR UNITS INSTALLED FOR NON-RESIDENTIAL USE. THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER'S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.

Some states and provinces do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights, which vary from state to state and province to province.

Repair Parts

Installation Parts

Diagram: Shows various installation parts labeled with key numbers.

KEY NO. PART NO. DESCRIPTION KEY NO. PART NO. DESCRIPTION
1 K029B0137 Remote control visor clip 10 041D0096-1 Light lens for light
2 K010A0020 3V CR2032 Lithium battery 11 041A5034 Safety Reversing Sensor kit (receiving and sending sensors) with 2-conductor wire attached
3 041A4582 Emergency release rope & handle assembly 12 041A6287 Remote Light (garage door opener light)
4 041A4494-1 2-Conductor wire - white and white/red NOT SHOWN
5 041A6104 Cable tension monitor 041A6288 Hardware bag for light
6 041D8615 Collar with set screws 041A6298 Installation hardware bag (includes hardware listed on page 6)
7 041B6228 Mounting bracket 114A5140 Owner's manual
8 041A5266-3 Safety reversing sensor brackets (2)
9 041A6102 Power door lock

Repair Parts (continued)

Garage Door Opener Parts

Diagram: Shows an exploded view of garage door opener parts, labeled with key numbers.

KEY NO. PART NO. DESCRIPTION KEY NO. PART NO. DESCRIPTION
1 041DJ002 Logic board complete with plate 4 041A6095 Motor with bracket
2 041B8861 Travel Module 5 04180122 Power cord
3 041C0168 Transformer 6 041A6348-3 Cover

Contact Information

Address repair parts order to:
The Chamberlain Group, Inc.
6050 S. Country Club Rd.
Tucson, AZ 85706

For installation and service information call:
1-800-528-9131
Or visit us online at:
www.chamberlain.com

BEFORE YOU CALL:

  1. Please have the model number of the garage door opener, found on the inside cover of door panel or front page of this manual.
  2. For a troubleshooting issue, have access to your garage door opener while calling.
  3. For ordering a repair part, have ready:
    a. part number:
    b. part name:
    c. model number of your garage door opener (see manual cover, or inside garage door opener cover).

PDF preview unavailable. Download the PDF instead.

D1iyqtDzQ7S Adobe PDF Library 15.0

Related Documents

Preview Chamberlain LED Belt Drive Garage Door Opener Installation Manual
Comprehensive installation guide for Chamberlain LED Belt Drive Garage Door Openers, covering models B4603TC, B4643TC, B4613TC, B6713TC, and B6753TC. Includes operation, maintenance, troubleshooting, and warranty information.
Preview Chamberlain Wall Mount Wi-Fi® Garage Door Opener RJO101 User Manual
User manual for the Chamberlain Wall Mount Wi-Fi® Garage Door Opener, Model RJO101. Provides installation, operation, safety, maintenance, and troubleshooting guidance for residential use.
Preview Chamberlain Wi-Fi Garage Door Opener User's Guide
Comprehensive user's guide for Chamberlain Wi-Fi Chain Drive and Belt Drive Garage Door Openers, covering installation, programming, operation, safety, maintenance, and troubleshooting for models C2102, C2202T, C2212T, C2405T, D2101, D2405T, B2202T, B2210T, B2211T, B2212T, B2215T, B2401T, B2405T, and B4505T.
Preview Chamberlain RJO101 Wall Mount Garage Door Opener Pre-Purchase Checklist
A pre-purchase checklist for the Chamberlain RJO101 Wall Mount Garage Door Opener, detailing power, sectional door, torsion bar, and drum requirements for safe installation and operation. Includes a glossary of terms and required tools.
Preview Chamberlain C2102 Installation Manual - Easy Setup Guide
Comprehensive installation manual for the Chamberlain C2102 Chain Drive Garage Door Opener. Includes step-by-step instructions, safety warnings, and troubleshooting tips for a smooth setup.
Preview Chamberlain RJO101 Wall Mount Wi-Fi Garage Door Opener User Manual
Comprehensive user manual for the Chamberlain RJO101 Wall Mount Wi-Fi Garage Door Opener. Learn about installation, operation, safety features, maintenance, and troubleshooting for residential use.
Preview Chamberlain RJO20C Wall Mount Garage Door Opener Manual
Comprehensive installation, operation, and maintenance guide for the Chamberlain RJO20C Wall Mount Garage Door Opener, designed for residential use on sectional doors with torsion assemblies.
Preview Chamberlain Wi-Fi Garage Door Opener Installation and Operation Guide
Comprehensive guide for Chamberlain Wi-Fi Garage Door Openers, covering installation, programming, operation, safety features, maintenance, and troubleshooting for models C2405, D2405, C2102, C2202, D2101, B2202, B2405, and B4505T.