Instruction Manual for TOSHIBA models including: BX704H3, BX704-RFID-H3-QM-S, BX704-RFID-H3-S, BX410T Series Barcode and Label Printers, BX410T Series, Barcode and Label Printers, Label Printers, Printers
Toshiba TEC Corporation BX704H3 BJI-BX704H3 BJIBX704H3 bx704h3
File Info : application/pdf, 8 Pages, 553.30KB
DocumentDocumentHF RFID kit Installation Manual HF RFID HF RFID kit BX704-RFID-H3-QM-S HF RFID BX704-RFID-H3-S BX704-RFID-H3-QM-S is optional HF RFID kit for the BX410T series. BX704-RFID-H3-S BX410T HF RFID ISO/IEC15693ISO/IEC18000-3 Mode1ISO/IEC14443 TypeAISO/IEC18092212 kbpsPassive Mode · TR3-C302 · TR3-A302 · FC-10002 WARNING! 1. Follow all manual instructions. Failure to do so may cause a fire, an electric shock, or injury. x Manual instructions must be followed when installing optional kits or adding cables to avoid system failures and to ensure correct operation. x Failure to follow manual instructions or any unauthorized modifications, substitution or change to this product will void the limited product warranty. 2. Before installing the optional kit, turn the power off and unplug the power plug from the AC outlet. Then disconnect the plug and interface cables from the printer. Otherwise, this may cause a fire, an electric shock, or injury. 3. Do not use a printer embedded with this product near medical equipment. Radio wave emitted from this product may affect the operation of medical equipment, such as an implanted cardiac pacemaker and implantable cardioverter-defibrillator. If a use of this product should be likely to have affected medical equipment, immediately turn off the product and contact your Toshiba Tec sales agent. Keep a printer embedded with this product at least 23 cm away from a person with an implanted cardiac pacemaker or implantable cardioverter-defibrillator. 4. Do not export a printer embedded with this product to the countries or areas where a use of this product is not allowed, without permission. Doing so is against the law, and you may be punished. When exporting this product, check the laws and regulations of a destination country and take necessary procedures. CAUTION! 1. Do not touch the print head, stepping motor or its neighboring parts immediately after printing, or you may burn yourself. 2. Be careful not to let your fingers or hands be pinched by the covers. 3. When opening the top cover, it must be fully opened. Failure to do this may cause the top cover to close under its own weight, resulting in an injury. 1 1. y y 2. OFF ON 3. 22 cm 4. 1. 2. 3. 2 Applicable Model (1) This optional device is intended for the following models: BX410T-GS02-QM-S, BX410T-TS02-QM-S Be careful not to install this product in any other models than above. (2) The country/region where the use of this device is allowed are as follows: Module name Frequency band Applicable country/region BX704-RFID-H3-QM-S (TR3-C302) 13.56 MHz *1 *1 Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, United Kingdom, Iceland, Norway, Switzerland, Liechtenstein, Korea, Malaysia, Singapore, Thailand, Australia, New Zealand, USA, Canada (3) This optional device must be installed with the BX904-R-QM-S Ribbon saving kit. (1) BX704-RFID-H3-S BX410T-TS02-S (2) BX704-RFID-H3-S BX704-RFID-H3-S (TR3-C302) 13.56 MHz For USA This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Toshiba America Business Solutions, Inc. 25530 Commercentre Drive Lake Forest, CA 92630 Tel: 949-462-6000 FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment must be installed and operated keeping the radiator at least 20 cm or more away from person's body. 3 Part 15 Subpart B Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. For Canada This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) L'appareil ne doit pas produire de brouillage ; (2) L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. This radio transmitter (ISED Certification Number: 1004C-BX704H3) has been approved by Innovation, Science and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device. Antenna type Gain Impedance Loop -65 dBi 50 Le présent émetteur radio (ISED Certification Number: 1004C-BX704H3) a été approuvé par Innovation, Sciences et Développement économique Canada pour fonctionner avec les types d'antenne énumérés ci dessous et ayant un gain admissible maximal. Les types d'antenne non inclus dans cette liste, et dont le gain est supérieur au gain maximal indiqué pour tout type figurant sur la liste, sont strictement interdits pour l'exploitation de l'émetteur. Type d'antenne Gain l'impédance Loop -65 dBi 50 This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment and meets RSS-102 of the ISED radio frequency (RF) Exposure rules. This equipment must be installed and operated keeping the radiator at least 20cm or more away from person's body. Cet équipement est conforme aux limites d'exposition aux rayonnements énoncées pour un environnement non contrôlé et respecte les règles d'exposition aux fréquences radioélectriques (RF) CNR-102 de l'ISDE. Cet équipement doit être installé et utilisé en gardant une distance de 20 cm ou plus entre le radiateur et le 4 corps humain. Packing List The following parts are supplied with the kit. Make sure you have all items shown below. If any parts are missing, contact your service representative. Antenna unit (1 pc.) 1 RFID R/W module (1 pc.) RFID R/W 1 Ribbon guide (1 pc.) 1 Interface cable (1 pc.) 1 Antenna cable (1 pc.) 1 Cord bushing (1 pc.) 1 Earth plate (1 pc.) 1 Spiral tube (2 pcs.) 2 Cable tie (2 pcs.) 2 Installation manual (1 copy) RFID sticker for Japan (1 pc.) RFID *1 1 * RFID Double-sems screw (SMW-3x6) (1 pc.) SMW-3x6 1 Tapping screw (PT-3x6) (5 pcs.) PT-3x65 R/W module attachment plate (2 pcs.) R/W 2 5 Installation Procedure WARNING! Do not start installing this module within one minute after turning off the printer. OFF 1 1. Turn the printer power off and disconnect the power cord. 1. OFF 2. Remove the three screws from the side panel (L). Slide the side panel (L) backward and raise it to remove from the printer. 2. 3 Side panel (L) 3. Fully open the top cover. 3. Top cover 6 4. Release the hook by pushing up the tab on the right end of the front panel. Slide the front panel to the right-hand side and pull it toward you to take it off. 4. Front panel Tab 5. Turn the head lever to the FREE position and gently open the ribbon shaft holder plate. 5. FREE Head lever 6. Open the print head block. 6. Ribbon shaft holder plate Print head block 7 8 7. Remove the E-ring on the head lever side of the left ribbon guide shaft and pull out the ribbon guide shaft. 7. E Head lever Ribbon guide shaft E-ring E Note: Keep the removed E-ring and ribbon guide shaft for future use. E 8. Remove the ribbon end sensor and disconnect the ribbon end sensor harness from the ribbon end sensor. 8. 10. Fit the sensor PCB into the ribbon guide. Insert the left side of the sensor PC board, then push the right side until it clicks. 10. PC PC Sensor PCB PC Ribbon guide 11. Connect the ribbon end sensor harness to the sensor PCB. 11. PC Ribbon end sensor harness Sensor PCB PC Ribbon guide Ribbon end sensor harness Ribbon end sensor 9. Separate the sensor PCB from the sensor frame. 9. PC Sensor PCB PC Sensor frame 9 10 12. Install the ribbon guide in the position from which the ribbon guide shaft has been removed. (1) Insert the ribbon guide shaft so that it matches the shape of the hole on the left, and fit it into the notch on the right. 12. (1) Hole Ribbon guide shaft Notch Ribbon guide (2) Push up the unsecured side of the ribbon guide and fit the left and right hooks into the rear ribbon guide shaft. (2) Rear ribbon guide shaft Hook (right) Hook (left) 13. Connect the antenna cable to the antenna. 13. Antenna attachment position Antenna cable Antenna 14. As shown in the figure below, hold the antenna unit so that the antenna comes to the lower side and the antenna attachment position comes to the right-hand side. Then fit the antenna unit into the bottom surface of the platen holder. 14. Tip: Align the four corners of the antenna unit to the notches indicated by the circles. Antenna unit Antenna attachment position 11 12 15. Close the print head block and the ribbon shaft holder plate, then remove the screw on the platen holder frame. 15. Print head block 17. Secure the upper side of the earth plate to antenna unit with the screw (SMW-3x6). 17. SMW-3x6 Screw Ribbon shaft holder plate Platen holder frame 16. Secure the lower side of the earth plate to the platen holder frame together by using the screw removed in the previous step. 16. Platen holder frame Earth plate Screw (SMW-3x6) SMW-3x6 18. Fit the cord bushing into the round hole on the main frame. 18. Main frame Cord bushing View from the front side 13 19. Pass the antenna cable through the cord bushing. 19. Antenna cable Cord bushing 20. Pull out the antenna cable from the opposite side and pass it through the inside of the cable protector. 20. Antenna cable Cable protector 14 21. Cut the original cable ties (2 places), then align the antenna cable with the other harnesses and secure it using the new cable ties provided. Note: Route the antenna cables away from power supplies to avoid noise interference. Thread the harness through the side of the sheet metal and use cable ties to ensure it doesn't touch the metal edges. 21. 2 Antenna cable Cable ties 22. Wrap the spiral tube around the first and second cable bundles on the left side of the cable clamps. 22. 1 2 Spiral tubes 15 16 23. Secure two RFID R/W module attachment plates with screws (PT-3x6). 23. 2 RFID R/W PT-3x6 Screws (PT-3x6) PT-3x6 R/W module attachment plate R/W 24. Secure the RFID R/W module attachment plates with three screws (PT-3x6). 24. RFID R/W 3 PT-3x6 Screws (PT-3x6) PT-3x6 Screw (PT-3x6) PT-3x6 25. Connect the wide connector of the interface cable to the CN1 connector on the RFID R/W module, and the narrow connector to the RFID connector on the main PC board. 25. RFID R/W CN1 PC RFID RFID connector RFID Interface cable Main PC board PC CN1 26. Connect the antenna cable into the CN2 connector of the RFID R/W module. 26. RFID R/W CN2 RFID R/W module RFID R/W CN2 Antenna cable 27. Attach the front panel, then close the top cover and attach the side panel (L). 27. 17 28. For Japan only: Attach the RFID sticker to the front of the printer. 28. RFID RFID sticker for Japan RFID 18 RFID RFID RFID 1. ON 2. FEEDPAUSE ON 29. Turn ON the POWER button while holding down the [FEED] and [PAUSE] buttons to enter the system mode. 29. FEEDPAUSE ON 30. Perform various settings related to the RFID in the system mode. 30. RFID 3. FEED/RESTARTRFID PAUSE 19 20 RFID RFID UHF EPC/UID TID Q AGC HOME CANCEL FEED+RESTART ENTER PAUSE RESTART FEED 21 (4) 3. (1) 99 mm 98 mm -98 mm -99 mm RFID RFID 0 -3 mm +3 mm 0 mm + (2) 255 254 1 0 RFID RFID VOID 3 (3) z 255 RFID RFID 254 1 RFID 0 5 z 9.9 9.8 0.1 0.0 RFID RFID RFID 4.0 23 1. (1) EPC/UID RFID ENTER LCD 16 RFID RFID RFID RFID RFID (2) TID 2. (1) x : RFID x UHF Band (U4) BX704-RFID-U4-S x HF Band (H3) BX704-RFID-H3-S OFF/ON (2) (3) x x ISO15693 / ISO14443 22 (4) z 255 RFID 254 RFID 1 5 0 z 9.9 9.8 0.1 0.0 RFID RFID 2.0 4. (1) (2) (3) RFID y y RFID 3 mm 24 5. RFID RFID RFID 1. RFID Module settings After installing the RFID module in the printer, set various settings related to the RFID in the system mode of the printer. 1. Plug the power cord and turn ON the main power switch. 2. Turn ON the POWER button while holding down the [FEED] and [PAUSE] buttons to enter the system mode. 3. Select [RFID] using the [FEED] / [RESTART] button and press the [PAUSE] button. 25 Contents of the RFID menu Menu RFID Sub menu Test Module Type Retry UHF Setting Other Carrier Sense Parameter EPC/UID Read TID Read Module Type Country/Region Code Tag RF Channel Write Retry Position Issue Retry Labels Read Retry Write Retry Power Level Q Value AGC Threshold Write AGC Threshold Write Retry Min AGC Calibration Mode Calibration AGC Calibration Position Antenna Position Error Tag Detection Multi Write Head Up Action Carrier Sense These items cannot be set with this kit. Key functions in the system mode Key [HOME] [CANCEL] or [FEED]+[RESTART] [ENTER] or [PAUSE] [UP] or [RESTART] [DOWN] or [FEED] [LEFT] [RIGHT] Function Returns to the Online mode screen. Returns to the top screen without saving settings. Displays a next screen. Saves the setting and returns to the upper screen. Moves the cursor upward. Increases a value. Moves the cursor downward. Decreases a value. Moves the cursor to the left. Moves the cursor to the right. 27 26 1. Test (1) EPC/UID Read The printer enters the read test mode to read the data of the RFID tag, and a read test is performed each time the [ENTER] key is pressed. When the data of a tag can be read, they are displayed on the LCD. (Example) Number of the tag is being read / Total number of tags read (This item is unavailable.) Read tag data (in hex) Only the tags selected for the RFID tag type can be read. If the type of the tag to be read does not match the one selected in the RFID tag type, an error will occur. Therefore, the RFID tag type shall be selected before the read test is started. When using short-pitch RFID tags and reading multiple tags at once, press the up and down arrow keys to switch the display of the read tag data. (2) TID Read This item is unavailable. 2. Module Type (1) Module Type x None: No RFID module is installed. x UHF Band (U4) BX704-RFID-U4-US-S/EU-S/AU-S/IN-S x HF Band (H3) BX704-RFID-H3-QM-S (Select this.) Tip: This setting will become effective after the printer power is turned off and then back on. (2) Country/Region Code This item is unavailable. (3) Tag x None No setting (default) x ISO15693 / ISO14443: Choose one according to the label you use. (4) RF Channel This item is unavailable. 28 3. Retry (1) Write Retry Position 99 mm 98 mm -98 mm -99 mm If writing data on a tag has failed, the printer feeds the RFID tag forward or backward for the specified length to retry the data write. When "0" is set for this parameter, this function and a retry are not performed. Only the value of 3 mm or less or +3 mm or more is effective. (Default value: 0 mm) * "-": Forward, "+": Backward (2) Issue Retry Labels 255 Set the maximum number of retries to issue an RFID tag. If printing is not successful even after the maximum number of 254 retires, the printer stops, resulting in an error. Moreover, when the issuing of an RFID tag has failed, the printer prints the error pattern (VOID) on the label. (Default value: 3 times) 1 0 (3) Read Retry The number of times a tag read is retried 255 Set the maximum number of retries to read an RFID tag. The printer retries to read the data in an RFID tag for up to the specified number of 254 times. If the timeout period expired before the maximum number of retries have been done, the printer stops the retries at this time. Whenever the printer writes data onto an RFID tag, the tag is read first. 1 The maximum number of retries set by this parameter also becomes 0 effective in this pre-read. (Default value: 5 times) Read retry timeout 9.9 sec. 9.8 sec. 0.1 sec. 0.0 sec. Set the timeout period during which RFID tag read retries are allowed. If the printer has retried for the maximum number of times within the RFID read retry timeout, the printer stops the retries at this time. Whenever the printer writes data onto an RFID tag, the tag is read first. The read retry timeout set by this parameter also becomes effective in this pre-read. (Default value: 4.0 seconds) 29 (4) Write Retry The number of times a tag write is retried 255 Set the maximum number of retries to write data onto an RFID tag. The printer retries to write data onto an RFID tag for up to the specified 254 number of times. If the timeout period expired before the maximum number of retries have been done, the printer stops the retries at this 1 time. (Default value: 5 times) 0 Write retry timeout 9.9 sec. 9.8 sec. 0.1 sec. 0.0 sec. Set the timeout period during which RFID tag write retries are allowed. If the printer has retried for the maximum number of times within the RFID write retry timeout, the printer stops the retries at this time. (Default value: 2.0 seconds) 4. Other (1) Error Tag Detection This item is unavailable. (2) Multi Write This item is unavailable. (3) Head Up Action Set the head-up operation when backfeeding the RFID tag. y Mode 1 Performs head-up operation during backfeed according to the ribbon save and head-up settings in system mode (ribbon save) and commands (issue, feed, reverse feed). y Mode 2 If the RFID module is installed and the feed amount is 3 mm or more for backfeed, head-up operation will be performed regardless of the system mode or command settings. 30 R231123B3101-TTEC BS230035A0-JA_EN Printed in Japan Copyright © 2024 Toshiba Tec CorporationAcrobat Distiller 24.0 (Windows)