User Guide for DEWALT models including: DW1, DW2, DW3, D-CLIP Wire Component, D-CLIP, Wire Component, Component

Tech Page - ToughWire™ D-Clip

toughwire d-clip, cable hangers, suspension, system, wire, rope, hvac, mep, mechanical, duct, channel, trapeze, gripple

DEWALT Anchors & Fasteners

Tech Page - ToughWire™ D-Clip

8 дней назад — in the sMACNA HVAC Duct Construction standards (HVAC-DCs), 4th Edition, Chapter 5,. Tables 5-1, 5-1M and 5-2. GUIDE SPECIFICATIONS. 3 05 29 - Hangers and ...

PDF preview unavailable. Download the PDF instead.

DW ToughWireDClip-TP-EN DDS1 ?1745064447=
CABLE HANGERS

ANCHORS & FASTENERS

GENERAL INFORMATION

GENERAL INFORMATION
D-CLIP
Wire Component
PRODUCT DESCRIPTION
The D-Clip Wire Component is a one piece clip that is used to fasten TOUGHWIrETM to the mounting surface. Can be mounted on flat or sloped surfaces. TOUGHWIrETM Loop End Wire Assembly products (sold separately) are looped through the D-Clip, then anchored to the structure with a variety of DEWALT® Anchors and Fasteners (sold separately).

SECTION CONTENTS
General Information.........................1 Material Specifications ...................2 Installation Specifications ..............2 Installation Instructions..................2 Performance Data............................3 Conditions of Use.............................4 Ordering Information.......................4

GENERAL APPLICATIONS AND USES · HVAC duct · Electrical and mechanical systems · Luminaires and lighting systems

· Plumbing & piping supports · signage and displays · Office partitions and panels

FEATURE AND BENEFITS
+ Multiple sizes - Avaliable in 5/16 in. hole size and 1/2 in. hole size to pair with DEWALT® Anchors And Fasteners (sold separately).
+ Versatile Hanging - Can be mounted on flat or sloped surfaces. + ToughWireTM Compatible - Can be used with all three ToughWireTM
wire diameters (DW1, DW2, and DW3, sold separately).

APPROVALS AND LISTINGS
· International Code Council, Evaluation service (ICC-Es), PMG-1786, Hangers for Pipe, Duct and Conduit support
· Code compliant with the 2024, 2021, 2018 and 2015 IMC, IPC, IrC, UMC and UPC · Tested in accordance with ICC-Es LC1041 for supports and hangers for pipe, ducts and conduit · Tested and verified to be an acceptable alternative to the duct hanger systems prescribed
in the sMACNA HVAC Duct Construction standards (HVAC-DCs), 4th Edition, Chapter 5, Tables 5-1, 5-1M and 5-2

GUIDE SPECIFICATIONS
3 05 29 - Hangers and supports for HVAC Piping and Equipment and 22 05 29 - Hangers and supports for Plumbing Piping and Equipment. Hangers shall be TOUGHWIrETM system as supplied by DEWALT, Towson, MD. Hangers shall be installed in accordance with published instructions and the Authority Having Jurisdiction.

D-CLIP
DEVCE MATERIAL · Zinc Plated Carbon steel SIZE RANGE · 5/16" Hole · 1/2" Hole SUITABLE MATERIAL PAIRING · TOUGHWIrETM Loop End
Wire Assembly
CODE LISTED
ICC-ES PMG-1786

TECHNICAL GUIDE ­ CAbLE HANGErs ©2025 DEWALT ­ rEV. A

1

MATERIAL SPECIFICATIONS

CABLE HANGERS

MATERIAL SPECIFICATIONS

Hanger/Device Component D-Clip
Zinc Plating

Component Material Carbon steel
AsTM b633 (Fe/Zn5) Min. plating requirements for mild service condition

INSTALLATION SPECIFICATIONS

Description

Clearance Hole Size

Suggested DEWALT® Anchor(s)

D-Clip for 1/4" Anchor/Fastener

5/16"

1/4" screw-bolt+

D-Clip for 3/8" Anchor/Fastener

1/2"

3/8" screw-bolt+

All three wire rope sizes DW1, DW2 and DW3 can be considered for use with both D-Clip parts.

INSTALLATION INSTRUCTIONS

ANCHORS & FASTENERS
L W
T
L = 1.5", W = 1" , T = 1/4"

Step 1 Pass the Loop End Wire Attachment through the opening of the D-Clip. Note: A loop created with a TOUGHLOCKTM device may also be used.
Note: Must follow safety instructions for tools.

Step 2
select and install an appropriate sized anchor through the D-Clip into the base material to the required minimum embedment. .
Note: The two sides of the D-Clip should be compressed together when the anchor is fully installed.
Note: refer to specific Anchor Installation Instructions

TECHNICAL GUIDE ­ CAbLE HANGErs ©2025 DEWALT ­ rEV. A

2

CABLE HANGERS

ANCHORS & FASTENERS

PERFORMANCE DATA

PERFORMANCE DATA

Allowable Load Capacities for TOUGHWIRETM D-Clip Assemblies in Normal-Weight Concrete1,2,3,4,5,6,7,8

Minimum Concrete Compressive Strength = 3,000 psi

Anchor Description

Nominal Anchor Diameter
(in.)

Minimum Embedment Depth in. (mm)

TOUGHWIRETM Size

lbs. (kN)
Mounting Orientation

D-Clip with 5/16" Clearance Hole (Cat. No. DTWDCLIP025)

DW1

40 (0.2)

40 (0.2)

screw-bolt+TM Hex Washer Head

1/4"

1 (25)

DW2

125 (0.6)

125 (0.6)

DW3

300 (1.3)

300 (1.3)

DW1

40 (0.2)

40 (0.2)

spike® Mushroom Head

1/4"

1 (25)

DW2 DW3

125 (0.6)
195 (0.9)

125 (0.6)
300 (1.3)

1-1/4 (31)

DW3

275 (1.2)

300 (1.3)

DW1

40 (0.2)

40 (0.2)

Power-stud®+ sD1

1/4"

1-1/8 (28)

DW2

125 (0.6)

125 (0.6)

DW3

300 (1.3)

300 (1.3)

DW1

40 (0.2)

40 (0.2)

UltraCon®

1 (25)

DW2

125 (0.6)

125 (0.6)

Hex Washer Head /

5/16"

TrimFit Hex Head

DW3

185 (0.8)

300 (1.3)

1-3/4 (45)

DW3

300 (1.3)

300 (1.3)

D-Clip with 1/2" Clearance Hole (Cat. No. DTWDCLIP044)

DW1

40 (0.2)

40 (0.2)

screw-bolt+TM Hex Washer Head

3/8"

1-1/2 (38)

DW2

125 (0.6)

125 (0.6)

DW3

300 (1.3)

300 (1.3)

DW1

40 (0.2)

40 (0.2)

spike® Mushroom Head

3/8"

1-3/4 (45)

DW2

125 (0.6)

125 (0.6)

DW3

300 (1.3)

300 (1.3)

DW1

40 (0.2)

40 (0.2)

Power-stud®+ sD1

3/8"

1-5/8 (41)

DW2

125 (0.6)

125 (0.6)

DW3

300 (1.3)

300 (1.3)

1. Tabulated load values are for anchors installed in uncracked concrete. Concrete compressive strength must be at the minimum at the time of installation. 2. In unshaded cells, the capacity of the wire rope controls the failure in the assembly. 3. In shaded cells, the capacity of anchor in concrete controls the failure in the assembly. 4. Allowable capacities are based on a safety factor of 4.0. 5. The minimum base material thickness should 3-1/2 inches. 6. Tabulated data is based on a minimum spacing distance of 2-3/4 inches for 1/4" and 5/16" diameter anchors and a minimum spacing distance of 4 inches for 3/8" diameter anchors. 7. Tabulated data is based on a minimum edge distance of 3-1/2 inches. 8. Nominal anchor length must exceed the minimum embedment depth + 1/4 inch.

TECHNICAL GUIDE ­ CAbLE HANGErs ©2025 DEWALT ­ rEV. A

3

CONDITIONS OF USE
CONDITIONS OF USE

ANCHORS & FASTENERS

CABLE HANGERS

Do not use in corrosive environments, e.g., chlorinated environments.

For use in dry, interior locations only.

ORDERING INFORMATION

ALWAYs wear safety glasses when working with TOUGHWIrETM.

D-Clip
Cat. No.
DTWDCLIP025 DTWDCLIP044

Description
D-Clip for 1/4" Anchor/Fastener D-Clip for 3/8" Anchor/Fastener

Clearance Hole Diameter (in.)
5/16"
1/2"

Pack Qty.
50 50

Carton Qty.
300 300

TOUGHWIRETM Loop End

Cat. No.

TOUGHWIRETM Size

DTW0106LE

DW1

DTW0112LE

DW1

DTW0120LE

DW1

DTW0206LE

DW2

DTW0212LE

DW2

DTW0220LE

DW2

DTW0235LE

DW2

DTW0306LE

DW3

DTW0312LE

DW3

DTW0320LE

DW3

DTW0335LE

DW3

TOUGHWIRETM Cable Length (ft)
6 12 20 6 12 20 35 6 12 20 35

Pack Qty.
75 50 25 25 25 25 25 25 25 10 15

Carton Qty.
300 200 100 100 100 100 100 100 100 40 30

TOUGHLOCKTM Wire Locking Device

Cat. No.

TOUGHWIRETM Size

DTWTOUGHLOCK01

DW1

DTWTOUGHLOCK02

DW2

DTWTOUGHLOCK03

DW3

Pack Qty. 100 50 25

Carton Qty. 1000 500 150

STRUTLOCKTM Wire Locking Devices

Cat. No.

TOUGHWIRETM Size

DTWsTrUTLOCK02

DW2

DTWsTrUTLOCK03

DW3

Pack Qty. 15 10

Carton Qty. 90 60

ALWAYs wear safety gloves when working with TOUGHWIrETM.

SQUARELOCKTM Wire Locking Device

Cat. No.

TOUGHWIRETM Size

SQUARELOCKTM Device Without EPDM Gasket

DTWsQLOCK02

DW2

DTWsQLOCK03

DW3

SQUARELOCKTM Device With EPDM Gasket

DTWsQLOCKP02

DW2

DTWsQLOCKP03

DW3

Pack Qty. Carton Qty.

50

300

20

120

50

300

20

120

TOUGHWIRETM Cable Cutter

Cat. No.

Description

DTWHANDCUTTEr

Cutters for DW1, DW2 and DW3 TOUGHWIrETM Cable

Pack Qty. 1

Carton Qty. 10

4

TECHNICAL GUIDE ­ CAbLE HANGErs ©2025 DEWALT ­ rEV. A

