Instruction Manual for Honeywell Home models including: YTHX9421R, TH6320R1004, THM4000R1000, RedLINK FocusPRO Thermostats, FocusPRO Thermostats, Thermostats
YTH6320R1001/U Thermostat - Honeywell Home | Resideo Pro
YTH6320R1023/U WiFi Thermostats | Honeywell Home
T4 Pro Programmable Thermostat, 1 Heat/1 Cool TH4110U2005/U -Honeywell Home From Resideo
File Info : application/pdf, 12 Pages, 904.70KB
DocumentDocumentRedLINK® Zoning Options TECHNICAL REFERENCE MANUAL ZONING WITH IAQ CONTROL RedLINK FocusPRO Thermostats 23 Zones System Type: 12 Stage Furnace + 12 Stage Cooling ............................................................................................ Option A. Page 2 Single Stage Heat Pump + Electric Heat Strips for Auxiliary Heat .......................................... Option A. Page 2 2 Stage Heat Pump + Electric Heat Strips for Auxiliary Heat .................................................... Option B. Page 3 Dual Fuel (1 of 2 Stage Heat Pump + 1 or 2 Stage Gas/Oil Furnace ...................................... Option C. Page 4 4 Zones System Type: 12 Stage Furnace + 12 Stage Cooling ............................................................................................ Option B. Page 2 Single Stage Heat Pump + Electric Heat Strips for Auxiliary Heat .......................................... Option B. Page 2 2 Stage Heat Pump + Electric Heat Strips for Auxiliary Heat ..................................................... Option B. Page 2 Dual Fuel (1 of 2 Stage Heat Pump + 1 or 2 Stage Gas/Oil Furnace ...................................... Option C. Page 4 532 Zones System Type: 12 Stage Furnace + 12 Stage Cooling ............................................................................................Option D. Page 4 Single Stage Heat Pump + Electric Heat Strips for Auxiliary Heat .......................................... Option D. Page 4 2 Stage Heat Pump + Electric Heat Strips for Auxiliary Heat ..................................................... Option D. Page 4 Dual Fuel (1 of 2 Stage Heat Pump + 1 or 2 Stage Gas/Oil Furnace ......................................Option D. Page 4 Prestige Thermostats for All Zones 23 Zones System Type: 12 Stage Furnace + 12 Stage Cooling ............................................................................................ Option E. Page 6 Single Stage Heat Pump + Electric Heat Strips for Auxiliary Heat .......................................... Option E. Page 6 2 Stage Heat Pump + Electric Heat Strips for Auxiliary Heat ......................................................Option F. Page 6 Dual Fuel (1 of 2 Stage Heat Pump + 1 or 2 Stage Gas/Oil Furnace ......................................Option G. Page 6 4 Zones System Type: 12 Stage Furnace + 12 Stage Cooling .............................................................................................Option F. Page 6 Single Stage Heat Pump + Electric Heat Strips for Auxiliary Heat ...........................................Option F. Page 6 2 Stage Heat Pump + Electric Heat Strips for Auxiliary Heat ......................................................Option F. Page 6 Dual Fuel (1 of 2 Stage Heat Pump + 1 or 2 Stage Gas/Oil Furnace ......................................Option G. Page 6 RedLINK VisionPRO Thermostats RedLINK VisionPRO Thermostats ............................................................................................................................. Page 8 Zoning without IAQ Control ......................................................................................................................................... Page 9 EIM to Zone Panel Wiring Diagrams ......................................................................................................................Page 10 33-00642-03 REDLINK® ZONING OPTIONS IAQ CONTROL FROM ZONE 1 STAT Option A: 23 Zones Table 1. 12 Stage Furnace + 12 Stage Cooling or Single Stage Heat-Pump + Electric Heat-Strips for Auxiliary Heat. No Dual Fuel. Parts list Description 1. HZ322K zone panel kit Includes HZ322 zone panel, C7735A1000 discharge sensor, and AT140A1042 transformer 2. YTHX9421R Prestige IAQ kit with Thermostat & EIM. (Different kits can also include accessories such as a RedLINK Internet gateway.) 3. YTH6320R1023 Includes TH6320R1004 wireless programmable FocusPRO thermostat and THM4000R1000 adapter 4. TH6320R1004 Wireless thermostat for zone 3 (not needed for 2 zone system) 5. Appropriate zone dampers and by-pass damper for the application Quantity 1 1 1 01 Option B: 24 Zones Table 2. 13 Stage Furnace + 12 Stage Cooling, or 12 Stage Heat-Pump + Electric Heat-Strips for Auxiliary Heat. Parts list Description 1. HZ432K zone panel kit Includes HZ432 zone panel, C7735A1000 discharge sensor, and AT140A1042 transformer 2. YTHX9421R Prestige IAQ kit with Thermostat & EIM. (Different kits can also include accessories such as a RedLINK Internet gateway.) 3. YTH6320R1023 Includes: TH6320R1004 wireless programmable FocusPRO thermostat and THM4000R1000 adapter 4. TH6320R1004 Wireless thermostats for zones 3 and 4 (not needed for 2 zone system) 5. Appropriate zone dampers and by-pass damper for the application Quantity 1 1 1 02 33-00642--03 2 REDLINK® ZONING OPTIONS Option C: 24 Zones Table 3. Dual Fuel. 12 Stage Heat-Pump + 12 Stage Gas Furnace. Parts list Description 1. HZ432K zone panel kit Includes: HZ432 zone panel, C7735A1000 discharge sensor, and AT140A1042 transformer 2. YTHX9421R Prestige IAQ kit with Thermostat & EIM. (Different kits can also include accessories such as a RedLINK Internet gateway.) 3. YTH6320R1023 Includes: TH6320R1004 wireless programmable FocusPRO thermostat and THM4000R1000 adapter 4. TH6320R1004 Wireless thermostats for zones 3 and 4 (not needed for 2 zone system) 5. C7089R1013 Wireless outdoor sensor for dual fuel changeover 6. Appropriate zone dampers and by-pass damper for the application Quantity 1 1 1 02 1 See Fig. 1 below for basic wiring. R 72 72 TO IAQ EQUIPMENT C R C Equipment Interface Module U2 U2 U1 U1 R C 4 Y G THM5421R1021 THX9421R5021 1 3 1 THE SUBBASE OF EACH THX9421R5021 THERMOSTAT NEEDS TO BE WIRED TO A 24 VOLT TRANSFORMER. THIS CAN EITHER BE THE TRANSFORMER THAT POWERS THE ZONE PANEL OR A SEPARATE TRANSFORMER. 2 EIMS AND ADAPTORS NEED TO BE AT LEAST 2 FEET APART FROM EACH OTHER. 3 THE SUPPLY AND RETURN SENSORS INCLUDED IN THE YTHX9421 2.0 PRESTIGE IAQ KITS ARE NOT USED IN ZONING APPLICATIONS. THE THERMOSTATS CANNOT BE SET FOR DELTA-T DIAGNOSTICS WHEN USED IN ZONING APPLICATIONS. 4 WIRING FROM EIM TO CORRESPONDING ZONE DEPENDS ON EQUIPMENT CONTROLLED. SEE PAGE 10 FOR SYSTEM SPECIFIC WIRING. THM4000R POWER WIRELESS SETUP CONNECTED CONNECT THM4000R1000 2 WIRELESS SENSORS ADD-APOWER ZONE EQUIPMENT THERMOSTAT ZONE 4 DAMPER THERMOSTAT M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L RH RC W1/E W2 W3 Y1 Y2 G O B DS/BK R C AZ1 AZ2 OT OT DATS DATS A B C D HZ432 HEAT 1 HEAT 2 HEAT 3 COOL 1 COOL 2 FAN PURGE EM HEAT ZONE 1 ZONE 2 ZONE 3 ZONE 4 EMERGENCY HEAT M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L WIRELESS HOME CONFIG CHECK OUT MODE BACK ADJUST SETTING NEXT THERMOSTAT HZ322 OR HZ432 (HZ432 PICTURED) Fig. 1. Zoning with IAQ equipment. ZONE 3 DAMPER ZONE 2 DAMPER THERMOSTAT ZONE 1 DAMPER HOLD TH6320R1004 HOLD TH6320R1004 M39247 3 33-00642--03 REDLINK® ZONING OPTIONS Option D: More Than 4 Zones (Cannot use THM4000R Wireless Adapter) Table 4. 13 Stage Furnace + 12 Stage Cooling, Heat-Pump with 12 Compressor Stages + Auxiliary Heat, or 12 Stage Heat-Pump + 12 Stage Gas Furnace (Dual Fuel). Parts list Description 1. HZ432K zone panel kit Includes: HZ432 zone panel, C7735A1000 discharge sensor, and AT140A1042 transformer 2. TAZ-4H Add-A-Zone panel 3. AT140A1042 40VA transformer 4. YTHX9421R Prestige IAQ kit with Thermostat & EIM. (Different kits can also include accessories such as a RedLINK Internet gateway.) 5. YTH6320R1001 Wireless FocusPRO and EIM kit 6. Appropriate zone dampers and by-pass damper for the application 7. C7089U1006 Wired outdoor sensor (required for dual fuel applications only) Quantity 1 1 per each additional 4 zones 1 per TAZ-4H panel 1 1 for each zone other than the Prestige zone 1 See Fig. 2 below for basic wiring. Equipment Interface Module R C U2 U2 U1 U1 R C Y G 3 THM5421R1021 R 72 TO IAQ 72 EQUIPMENT C THX9421R5021 1 4 WIRELESS SENSORS ADD-APOWER ZONE EQUIPMENT THERMOSTAT ZONE 4 DAMPER M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L RH RC W1/E W2 W3 Y1 Y2 G O B DS/BK R C AZ1 AZ2 OT OT DATS DATS A B C D HZ432 HEAT 1 HEAT 2 HEAT 3 COOL 1 COOL 2 FAN PURGE EM HEAT ZONE 1 ZONE 2 ZONE 3 ZONE 4 EMERGENCY HEAT M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L HOME CONFIG CHECK OUT MODE BACK ADJUST SETTING NEXT ZONE A DAMPER THERMOSTAT ZONE B DAMPER THERMOSTAT AT140A1042 TRANSFORMER 1 THM5320R POWER HEAT COOL FAN 1 EIMS AND ADAPTORS NEED TO BE AT LEAST 2 FEET APART FROM EACH OTHER. 2 THE SUPPLY AND RETURN SENSORS INCLUDED IN THE YTHX9421 2.0 PRESTIGE IAQ KITS ARE NOT USED IN ZONING APPLICATIONS. THE THERMOSTATS CANNOT BE SET FOR DELTA-T DIAGNOSTICS WHEN USED IN ZONING APPLICATIONS. 3 WIRING FROM EIM TO CORRESPONDING ZONE DEPENDS ON EQUIPMENT CONTROLLED. SEE PAGE 10 FOR SYSTEM SPECIFIC WIRING. 4 THE PRESTIGE EIM IS TYPICALLY WIRED TO ZONE 1. THIS DIAGRAM SHOWS IT GOING TO ZONE 4 TO SIMPLIFY THE LAYOUT OF THE DIAGRAM. AT140A1042 1 TRANSFORMER ADD-APOWER ZONE THERMOSTAT ZONE D DAMPER HZ432 M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L R C AZ1 AZ2 TAZ-4H ZONE A ZONE B ZONE C ZONE D M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L HOME CONFIG CHECK OUT MODE BACK ADJUST SETTING NEXT TAZ-4H ZONE C DAMPER THERMOSTAT THERMOSTAT ZONE 3 DAMPER THERMOSTAT ZONE 2 DAMPER THERMOSTAT ZONE 1 DAMPER THM5320R POWER HEAT COOL FAN THM5320R POWER HEAT COOL FAN THM5320R POWER HEAT COOL FAN THM5320R1000 EQUIPMENT 3 INTERFACE MODULES 1 2 THM5320R POWER HEAT COOL FAN THM5320R POWER HEAT COOL FAN THM5320R POWER HEAT COOL FAN THM5320R1000 EQUIPMENT 3 INTERFACE MODULES 1 2 TH6320R1004 WIRELESS THERMOSTATS HOLD HOLD HOLD HOLD HOLD HOLD HOLD M39274 Fig. 2. More than 4 zones with Prestige on zone 1 and RedLINK FocusPRO for other zones. 33-00642--03 4 REDLINK® ZONING OPTIONS NO IAQ EQUIPMENT OR ECONOMIZER CONTROL For any of the 2-4 zone applications listed in this document that do not need to control a Humidifier, Dehumidifier, Ventilator, economizer, or Remote Indoor Sensor, you can eliminate the THM5421R1021. You can either enroll the Prestige IAQ thermostat to the THM4000R1000 wireless adapter that is included in the YTH6320R1023 kit or use another TH6320R1004 thermostat for zone 1 in place of the Prestige IAQ. When a TAZ-4H is used for systems over 4 zones, you cannot use a THM4000R1000. See Fig. 3 below for basic wiring. R 72 C 72 THX9421R5021 2 3 LOW VOLTAGE TRANSFORMER THM4000R POWER WIRELESS SETUP CONNECTED CONNECT THM4000R1000 1 WIRELESS SENSORS ADD-APOWER ZONE EQUIPMENT THERMOSTAT ZONE 4 DAMPER M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L RH RC W1/E W2 W3 Y1 Y2 G O B DS/BK R C AZ1 AZ2 OT OT DATS DATS A B C D HZ432 HEAT 1 HEAT 2 HEAT 3 COOL 1 COOL 2 FAN PURGE EM HEAT ZONE 1 ZONE 2 ZONE 3 ZONE 4 EMERGENCY HEAT M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L WIRELESS HOME CONFIG CHECK OUT MODE BACK ADJUST SETTING NEXT HZ322 OR HZ432 (HZ432 PICTURED) THERMOSTAT ZONE 3 DAMPER THERMOSTAT ZONE 2 DAMPER THERMOSTAT ZONE 1 DAMPER HOLD TH6320R1004 HOLD TH6320R1004 1 EIMS AND ADAPTORS NEED TO BE AT LEAST 2 FEET APART FROM EACH OTHER. 2 THE SUPPLY AND RETURN SENSORS INCLUDED IN THE YTHX9421 2.0 PRESTIGE IAQ KITS ARE NOT USED IN ZONING APPLICATIONS. THE THERMOSTATS CANNOT BE SET FOR DELTA-T DIAGNOSTICS WHEN USED IN ZONING APPLICATIONS. 3 PRESTIGE IAQ THERMOSTATS USED WITH A THM4000R ADAPTOR AND THM6000R GATEWAY LOSE THE 2.0 FUNCTIONALITY ONLINE. THIS MEANS YOU WILL BE ABLE TO OVERRIDE THE SET POINT BUT CANNOT PROGRAM THEM OR CONTROL THE FAN SETTING VIA APP. ALSO THEY CANNOT BE USED IN A DEMAND RESPONSE UTILITY PROGRAM. ALSO YOU CANNOT USE THOSE THERMOSTATS WITH AN R EM1000R1003 EXIT/ENTRY CONTROL OR WSK 24 REMOTE SETBACK. M39249 Fig. 3. No IAQ Equipment. 5 33-00642--03 REDLINK® ZONING OPTIONS ALL PRESTIGE THERMOSTATS WITHOUT IAQ CONTROL Option E: 23 Zones (If C7189R or C7189U Indoor Sensors are Used, Cannot Use THM4000R. Need . separate EIM for Each Stat) Table 5. 12 Stage Furnace + 12 Stage Cooling or Single Stage Heat-Pump + Electric Heat-Strips for Auxiliary Heat. Not Dual Fuel. Parts list Description Quantity 1. HZ322K zone panel Includes: HZ322 zone panel, C7735A1000 discharge sensor, and AT140A1042 1 kit transformer 2. YTHX9421R Prestige IAQ kit with Thermostat & EIM for IAQ zone (usually zone 1). Different kits 1 can also include accessories such as a RedLINK Internet gateway 3. THX9421R5021 Prestige without EIM for zones 23 12 4. THM4000R1000 Wireless adapter for zone 23 Prestige IAQ thermostats not controlling IAQ 1 equipment or using an indoor sensor 5. Appropriate zone dampers and by-pass damper for the application Option F: 24 Zones (If C7189R or C7189U Indoor Sensors are Used, Cannot Use THM4000R. Need . Separate EIM for Each Stat) Table 6. 13 Stage Furnace + 12 Stage Cooling, or 12 Stage Heat-Pump + Electric Heat-Strips for Auxiliary Heat. Parts list Description Quantity 1. HZ432K zone panel Includes: HZ432 zone panel, C7735A1000 discharge sensor, and AT140A1042 1 kit transformer 2. YTHX9421R Prestige IAQ kit with Thermostat & EIM for IAQ zone (usually zone 1). Different kits 1 can also include accessories such as a RedLINK Internet gateway 3. THX9421R5021 Prestige without EIM for zones 24 13 4. THM4000R1000 Wireless adapter for zone 24 Prestige IAQ thermostats not controlling IAQ 1 equipment or using an indoor sensor 5. Appropriate zone dampers and by-pass damper for the application. Option G: 24 Zones (If C7189R or C7189U Indoor Sensors are Used, Cannot Use THM4000R. Need . Separate EIM for Each Stat) Table 7. Dual Fuel. 12 Stage Heat-Pump + 12 Stage Gas Furnace. Parts list Description 1. HZ432K zone panel Includes: HZ432 zone panel, C7735A1000 discharge sensor, and AT140A1042 kit. transformer 2. YTHX9421R Prestige IAQ kit with Thermostat & EIM for IAQ zone (usually zone 1). Different kits can also include accessories such as a RedLINK Internet gateway 3. THX9421R5021 Prestige without EIM for zones 24 4. THM4000R1000 Wireless adapter for zone 2-4 Prestige IAQ thermostats not controlling IAQ equipment or using an indoor sensor 5. C7089R1013 Wireless outdoor sensor 6. Appropriate zone dampers and by-pass damper for the application Quantity 1 1 13 1 1 See Fig. 4 below for basic wiring. 33-00642--03 6 REDLINK® ZONING OPTIONS R 72 72 TO IAQ EQUIPMENT R Equipment Interface Module C U2 U2 U1 U1 R C Y 5G 23 THM5421R1021 C THX9421R5021 1 1 THE SUBBASE OF EACH THX9421R5021 THERMOSTAT NEEDS TO BE WIRED TO A 24 VOLT TRANSFORMER. THIS CAN EITHER BE THE TRANSFORMER THAT POWERS THE ZONE PANEL OR A SEPARATE TRANSFORMER. THM4000R POWER WIRELESS SETUP CONNECTED CONNECT 2 EIMS AND ADAPTORS NEED TO BE AT LEAST 2 FEET APART FROM EACH OTHER. 3 THE SUPPLY AND RETURN SENSORS INCLUDED IN THE YTHX9421 2.0 PRESTIGE THM4000R1000 2 IAQ KITS ARE NOT USED IN ZONING APPLICATIONS. THE THERMOSTATS CANNOT BE SET FOR DELTA-T DIAGNOSTICS WHEN USED IN ZONING APPLICATIONS. WIRELESS SENSORS ADD-APOWER ZONE EQUIPMENT THERMOSTAT ZONE 4 DAMPER M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L RH RC W1/E W2 W3 Y1 Y2 G O B DS/BK R C AZ1 AZ2 OT OT DATS DATS A B C D HZ432 HEAT 1 HEAT 2 HEAT 3 COOL 1 COOL 2 FAN PURGE EM HEAT ZONE 1 ZONE 2 ZONE 3 ZONE 4 EMERGENCY HEAT M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L WIRELESS HOME CONFIG CHECK OUT MODE BACK ADJUST SETTING NEXT HZ322 OR HZ432 (HZ432 PICTURED) THERMOSTAT ZONE 3 DAMPER THERMOSTAT ZONE 2 DAMPER THERMOSTAT ZONE 1 DAMPER 72 72 72 72 1 THX9421R5021 PRESTIGE THERMOSTATS 4 PRESTIGE IAQ THERMOSTATS USED WITH A THM4000R ADAPTOR AND THM6000R GATEWAY LOSE THE 2.0 FUNCTIONALITY ONLINE. THIS MEANS YOU WILL BE ABLE TO OVERRIDE THE SET POINT BUT CANNOT PROGRAM THEM OR CONTROL THE FAN SETTING VIA APP. ALSO THEY CANNOT BE USED IN A DEMAND RESPONSE UTILITY PROGRAM. ALSO YOU CANNOT USE THOSE THERMOSTATS WITH AN REM1000R1003 EXIT/ENTRY CONTROL OR WSK 24 REMOTE SETBACK. 5 WIRING FROM EIM TO CORRESPONDING ZONE DEPENDS ON EQUIPMENT CONTROLLED. SEE PAGE 10 FOR SYSTEM SPECIFIC WIRING. M39250 Fig. 4. Zoning with IAQ equipment (humidifier, dehumidifier, or ventilator). 7 33-00642--03 REDLINK® ZONING OPTIONS Option H: More Than 4 zones (Cannot Use THM4000R Wireless Adapter) Table 8. 13 Stage Furnace + 12 Stage Cooling, Heat-Pump with 12 Compressor Stages + Auxiliary Heat, or 12 Stage Heat-Pump + 12 Stage Gas Furnace (Dual Fuel). Parts list 1. HZ432K zone panel kit 2. TAZ-4H Description Includes HZ432 zone panel, C7735A1000 discharge sensor, and AT140A1042 transformer Add-A-Zone panel 3. AT140A1042 40VA transformer 4. YTHX9421R Prestige IAQ thermostat kit with EIM 5. Appropriate zone dampers and by-pass damper for the application 6. C7089U1006 Wired outdoor sensor (required for dual fuel applications only) Quantity 1 1 per each additional 4 zones 1 per TAZ-4H panel 1 for each zone 1 RedLINK VisionPRO instead of Prestige For any of the AF applications listed, you could replace the Prestige IAQ thermostats with TH8321R1001 RedLINK VisionPRO models. When the RedLINK VisionPRO models are used, you can link to the THM5421R1021 or THM4000R1000 (same as Prestige) or wire directly from the thermostat sub-base to the zone connection on the zone panel if wires are available. See Fig. 5 below for basic wiring. Equipment Interface Module 2 4 R C U2 U2 U1 U1 R C W Y G THM5421R1021 R 72 TO IAQ 72 EQUIPMENT C THX9421R5021 1 AT140A1042 TRANSFORMER 1 1 THE SUBBASE OF EACH THX9421R5021 THERMOSTAT NEEDS TO BE WIRED TO A 24 VOLT TRANSFORMER. THIS CAN EITHER BE THE TRANSFORMER THAT POWERS THE ZONE PANEL OR A SEPARATE TRANSFORMER. 2 EIMS NEED TO BE AT LEAST 2 FEET APART FROM EACH OTHER. 3 THE SUPPLY AND RETURN SENSORS INCLUDED IN THE YTHX9421 2.0 PRESTIGE IAQ KITS ARE NOT USED IN ZONING APPLICATIONS. THE THERMOSTATS CANNOT BE SET FOR DELTA-T DIAGNOSTICS WHEN USED IN ZONING APPLICATIONS. 4 WIRING FROM EIM TO CORRESPONDING ZONE DEPENDS ON EQUIPMENT CONTROLLED. SEE PAGE 10 FOR SYSTEM SPECIFIC WIRING. Equipment Interface Module AT140A1042 1 TRANSFORMER ADD-APOWER ZONE THERMOSTAT ZONE D DAMPER ZONE 4 DAMPER THERMOSTAT EQUIPMENT ADD-APOWER ZONE M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L RH RC W1/E W2 W3 Y1 Y2 G O B DS/BK R C AZ1 AZ2 OT OT DATS DATS A B C D HZ432 HEAT 1 HEAT 2 HEAT 3 COOL 1 COOL 2 FAN PURGE EM HEAT ZONE 1 ZONE 2 ZONE 3 ZONE 4 EMERGENCY HEAT M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L HOME CONFIG CHECK OUT MODE BACK ADJUST SETTING NEXT HZ432 SENSORS WIRELESS ZONE A DAMPER THERMOSTAT ZONE B DAMPER THERMOSTAT ZONE C DAMPER M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L R C AZ1 AZ2 TAZ-4H ZONE A ZONE B ZONE C ZONE D M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L HOME CONFIG CHECK OUT MODE BACK ADJUST SETTING NEXT TAZ-4H THERMOSTAT THERMOSTAT ZONE 3 DAMPER THERMOSTAT ZONE 2 DAMPER THERMOSTAT ZONE 1 DAMPER Equipment Interface Module Equipment Interface Module Equipment Interface Module 2 34 THM5421R1021 EQUIPMENT INTERFACE MODULES Equipment Interface Module Equipment Interface Module Equipment Interface Module 2 34 THM5421R1021 EQUIPMENT INTERFACE MODULES Fig. 5. More than 4 zones with all Prestige. THX9421R5021 THERMOSTATS 1 72 72 72 72 72 72 72 72 72 72 72 72 72 72 M39275A 33-00642--03 8 REDLINK® ZONING OPTIONS No IAQ Equipment Any of the above listed 2-4 zone applications that do not need to control a Humidifier, Dehumidifier, Ventilator, Economizer or Remote Indoor Sensor can eliminate the THM5421R1021. You can enroll all Prestige IAQ or RedLINK VisionPRO thermostats to the THM4000R1000 wireless adapter. When a TAZ-4H is used for systems over 4 zone you cannot use a THM4000R1000. See Fig. 6 below for basic wiring. R 72 72 C THX9421R5021 3 4 LOW VOLTAGE TRANSFORMER THM4000R POWER WIRELESS SETUP CONNECTED CONNECT 2 THM4000R1000 WIRELESS SENSORS ADD-AZONE POWER EQUIPMENT THERMOSTAT ZONE 4 DAMPER M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L RH RC W1/E W2 W3 Y1 Y2 G O B DS/BK R C AZ1 AZ2 OT OT DATS DATS A B C D HZ432 HEAT 1 HEAT 2 HEAT 3 COOL 1 COOL 2 FAN PURGE EM HEAT ZONE 1 ZONE 2 ZONE 3 ZONE 4 EMERGENCY HEAT M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L WIRELESS HOME CONFIG CHECK OUT MODE BACK ADJUST SETTING NEXT HZ322 OR HZ432 (HZ432 PICTURED) THERMOSTAT ZONE 3 DAMPER THERMOSTAT ZONE 2 DAMPER THERMOSTAT ZONE 1 DAMPER 72 72 1 3 4 THX9421R5021 72 72 1 3 4 THX9421R5021 1 THE SUBBASE OF EACH THX9421R5021 THERMOSTAT NEEDS TO BE WIRED TO A 24 VOLT TRANSFORMER. THIS CAN EITHER BE THE TRANSFORMER THAT POWERS THE ZONE PANEL OR A SEPARATE TRANSFORMER. 2 EIMS AND ADAPTORS NEED TO BE AT LEAST 2 FEET APART FROM EACH OTHER. 3 THE SUPPLY AND RETURN SENSORS INCLUDED IN THE YTHX9421 2.0 PRESTIGE IAQ KITS ARE NOT USED IN ZONING APPLICATIONS. THE THERMOSTATS CANNOT BE SET FOR DELTA-T DIAGNOSTICS WHEN USED IN ZONING APPLICATIONS. 4 PRESTIGE IAQ THERMOSTATS USED WITH A THM4000R ADAPTOR AND THM6000R GATEWAY LOSE THE 2.0 FUNCTIONALITY ONLINE. THIS MEANS YOU WILL BE ABLE TO OVERRIDE THE SET POINT BUT CANNOT PROGRAM THEM OR CONTROL THE FAN SETTING VIA APP. ALSO THEY CANNOT BE USED IN A DEMAND RESPONSE UTILITY PROGRAM. ALSO YOU CANNOT USE THOSE THERMOSTATS WITH AN REM1000R1003 EXIT/ENTRY CONTROL OR WSK 24 REMOTE SETBACK. M39252 Fig. 6. No IAQ equipment or remote indoor sensor. 9 33-00642--03 REDLINK® ZONING OPTIONS EIM to Zone Panel Wiring Diagrams ZONE 1 DAMPER M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L THERMOSTAT R Rc 1 Rh C W 2 W2 Y 2 Y2 G EIM HZ322 OR HZ432 ZONE PANEL 1 LEAVE R, Rc, Rh JUMPERS INSTALLED. 2 DOTTED LINES FOR MULTI-STAGE ONLY. Fig. 7. Gas furnace and AC. M39276 ZONE 1 DAMPER M1 M4 M6 R C W1/E W2 2 W3 Y1 Y2 G O/B L THERMOSTAT R Rc 1 Rh C Aux Y G O/B EIM HZ322 OR HZ432 ZONE PANEL 1 LEAVE R, Rc, Rh JUMPERS INSTALLED. 2 ADD A JUMPER FROM W1/E TO W2 AT ZONE PANEL. M39277 Fig. 8. Heat pump with 1-stage compressor and electric strips. 33-00642--03 10 REDLINK® ZONING OPTIONS ZONE 1 DAMPER M1 M4 M6 R C W1/E W2 W3 2 Y1 Y2 G O/B L THERMOSTAT R Rc 1 Rh C Aux Y Y2 G O/B EIM HZ432 1 LEAVE R, Rc, Rh JUMPERS INSTALLED. 2 ADD A JUMPER FROM W1/E TO W3 AT ZONE PANEL. M39278 Fig. 9. Heat pump with 2-stage compressor and electric strips. ZONE 1 DAMPER M1 M4 M6 R C W1/E W2 W3 Y1 Y2 G O/B L THERMOSTAT R Rc 1 Rh C Aux Y 2 Y2 G O/B EIM HZ432 1 LEAVE R, RC, RH JUMPERS INSTALLED. 2 DOTTED LINES FOR DOTTED LINES FOR 2 STAGE COMPRESSOR ONLY. M39279 Fig. 10. Dual fuel heat pump. To Learn More For more information regarding zoning, contact 800-468-1502, or for technical literature go to customer.resideo.com 11 33-00642--03 REDLINK® ZONING OPTIONS www.resideo.com Resideo Technologies, Inc. 1985 Douglas Drive North, Golden Valley, MN 55422 1-800-468-1502 33-00642--03 SA Rev. 05-23 | Printed in United States © 2023 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.Adobe PDF Library 17.0