Instruction Manual for solarV models including: MT11, Remote Display Meter for the DuoRacer Solar Controller

amy song

INSTRUCTION MANUAL

EN www.solarv.de Copyright © 2021 SolarV GmbH Boost Reconnect Charging Voltage 13.2V 13.2V 13.2V 9~17V

PDF Instruction Manual


File Info : application/pdf, 17 Pages, 832.77KB

PDF preview unavailable. Download the PDF instead.

User-Manual-EN-MT11
INSTRUCTION MANUAL
Remote Meter: MT11

EN Important Safety Instructions
Thank you for selecting the remote meter. General safety information  Please contact our company or transportation if the product has been damaged.  Please read this manual carefully before using the product and pay attention to
the safety information.  Keep the product away from rain, exposure, severe dust, vibrations, corrosive
gas and intense electromagnetic interference.  Do not allow water to enter the product.  There are no user serviceable parts inside the product. Do not disassemble or
attempt to repair it.
Recommendations  The MT11 is only allowed to connect with DR-N series charge controller. Please
confirm before purchase and installation.  Please do not install MT11 in a situation with strong electromagnetic
interference.

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
Contents
1.Overview ............................................................................................ 2 2.Product classification ......................................................................... 3 3. Installation ........................................................................................ 4 3.1 Base of MT11 (Optional accessory) .......................................... 4 3.2 Wall installation steps ............................................................... 5 3.3 Surface mounting steps ............................................................ 7 4.Product Features ............................................................................... 8 4.1 Front View ................................................................................ 8 4.2 Rear View ................................................................................. 9 5.Display and operation ...................................................................... 11 5.1LCD display ............................................................................. 11 5.2 Auto global view mode ............................................................ 12 5.3 Temperature units ................................................................... 14 5.4 Clear the generated energy .................................................... 14 5.5 Battery type ............................................................................ 15 5.6 Fault indication ....................................................................... 19 6.Technical Specifications ..................... 20

www.solarv.de

Copyright © 2021 SolarV GmbH

EN

1. Overview
The MT series remote meter is an accessory which is compatible with the DuoRacer series controller. It can monitor the running data and working status of the controller via the remote meter. The remote meter can browse the controller's parameters, set the battery type and temperature unit, and clean the generated energy. It is suitable for RV, Camper, Boat, and so on. Features  Automatically identify and display the type, model and relevant parameter data of
controllers.  Real-time display the operational data and working status of the connected
devices in digital, graphics and textual forms by a large-screen multifunction LCD.  Three touch buttons are easy and quick to operate.  No need for external power supply. Charge controller supplies the power for
MT11.  It can browse the controller's parameters, set the battery type and temperature
unit, and clean the generated energy.  Real-time display of failure information of the connected devices.  Longer communication distance based on RS485.

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
2. Product classification
1) MT11(include the 1.5m communication cable)  Remote meter MT11  1.5m communication cable (Model: CC-RS485-RS485-3.81-4P-150)  Base of MT11 2) MT11 (include the 5m communication cable)  Remote meter MT11  5m communication cable (Model: CC-RS485-RS485-3.81-4P-500)  Base of MT11 3) MT11 (include the 10m communication cable)  Remote meter MT11  10m communication cable (Model:CC-RS485-RS485-3.81-4P-1000)  Base of MT11 4) MT11(Do not include the communication cable)  Remote meter MT11  1.5m communication cable (Model: CC-RS485-RS485-3.81-4P-150)  Do not include Base of MT11
NOTE: The user can purchase the product according to the requirement.

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
3. Installation
3.1 Base of MT11 (Optional accessory)

Mechanical parameter Overall dimension Mounting dimension Terminal

Parameter 114 x 114 x 44.41mm 88.6 x 88.6mm 5

3.2 Wall installation steps Step1: Locate and drill screw holes based on the Frame Mounting dimension of the base, and erect the plastic expansion bolts.

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
Step2: Use four PA4.2×32 self-tapping screws to fix the Frame. Step3: Remove the decorative shell. Step4: Use four M4×8 pan head screws to mount MT11 Surface on the Frame. Step5: Install the decorative shell.

3.3 Surface mounting steps

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
Step1: Locate and drill screw holes based on the installation size of the surface.
Step2: Remove the decorative shell
Step3: Use four M4×8 cross recessed pan head screws with M4 nuts to mount MT11 surface onto the panel.
Step4: Install the decorative shell
NOTE: Take full consideration of the plugging/unplugging space of the communication cable and the length of the cable during installation to see if they are appropriate.

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
4. Product Features
4.1 Front View

LCD display screen Man-machine interaction operation interface. Refer to the chapter 5 Display and Operation. Buttons The meter buttons include two function buttons and one switch button.

Press the button
Press the button
Press the button and hold on 5s Press the button Press the button and hold on 5s

1.PV array parameters

2.Storage battery parameters

3.Browse the start battery parameters

automatically (

)

Browse the PV array parameters

Browse the Storage battery parameters

Browse the start battery parameters

Temperature units

Battery type

The meter is powered ON

The meter is powered OFF

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
4.2 Rear View

RS485 communication port

It is used to connect the controller which powers the MT11.

Communication cable's models

CC-RS485-RS485-3.81-4P-150(Included)

CC-RS485-RS485-3.81-4P-1000(Optional)

CC-RS485-RS485-3.81-4P-2000(Optional)

Pins definition
PIN 1 2 3 4

Definition DC5V RS-485-B RS-485-A GND

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
5. Display and Operation
5.1 LCD Display

Icon Instruction

Icon

BATT1 battery capacity level012%

Instruction
BATT2battery capacity level012%

BATT1battery capacity level13%35%
BATT1battery capacity level36%61%
BATT1battery capacity level62%86%
BATT1battery capacity level 87%100%
Day
Night
Display the parameters of PV Display the parameters of BATT1

BATT2battery capacity level13%35%
BATT2battery capacity level36%61% BATT2battery capacity level62%86% BATT2battery capacity level 87%100% PV array
BATT1 charging icon
BATT2 charging icon
BATT1temperature parameters

www.solarv.de

Copyright © 2021 SolarV GmbH

Display the parameters of BATT2 Setting icon
Auto global view sign
Fault Icon

EN
AES signal icon Battery type icon
Minimum voltage icon Maximum voltage icon

Battery power capacity is calculated by the linear relationship between the disconnect voltage of low voltage and float charging voltage.

5.2 Auto Global View Mode

Operation: Step1: Press the Step2: Press the

button,

appears.

button, select the .

Echo LoopPV voltage --PV current --PV power--Battery power--BATT1 voltage-- BATT1 current--Max. BATT1 voltage--Min.BATT1 voltage--BATT1 temperature--

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
BATT1 battery type--BATT2 voltage--BATT2 current--Max. BATT1 voltage-- Min.BATT2 voltage--PV voltage
5.3 Temperature units

Operation: Step1: Press the Step2: Press the Step3: Press the

button under the battery temperature interface. button to select the temperature unit. button to set successfully.

5.4 Clear the generated energy

Press the and

button and hold on 5s to clear the generated energy.

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
5.5 Battery type

1)Operation: Step1: Press the Step2: Press the Step3: Press the 2) Battery type

button and hold 5s under the battery type interface. button when the battery type interface is flashing. button to confirm the battery type.

BATT112V Sealed BATT112V Gel BATT112V Flooded LiFePO4(4S) Li-NiCoMn (3S) User

BATT124V Sealed BATT124V Gel BATT124V Flooded LiFePO4(8S) Li-NiCoMn (6S)

CAUTION: The battery voltage is set as default and not changeable when selecting the default battery type. Please change to "User" battery type before adjusting the battery voltage.

CAUTION: Set the voltage of the "User" battery type via PC software only.

1) Lead-acid Battery Control Voltage Parameters

The parameters are in the 12V system at 25 ºC. Please double the values in the 24V

system.

Battery type
Voltage parameter Over Voltage Disconnect Voltage

Sealed 16.0V

Gel Flooded User 16.0V 16.0V 9~17V

Charging Limit Voltage

15.0V 15.0V 15.0V 9~17V

Over Voltage Reconnect Voltage

15.0V 15.0V 15.0V 9~17V

Equalize Charging Voltage Boost Charging Voltage

14.6V 14.4V

---- 14.2V

14.8V 14.6V

9~17V 9~17V

Float Charging Voltage

13.8V 13.8V 13.8V 9~17V

www.solarv.de

Copyright © 2021 SolarV GmbH

EN

Boost Reconnect Charging Voltage Low Voltage Reconnect Voltage Under Voltage Warning Reconnect Voltage
Under Volt. Warning Voltage Low Volt. Disconnect Voltage Discharging Limit Voltage Equalize Duration (min.)

13.2V 12.6V
12.2V
12.0V 11.1V 10.6V 120

13.2V 12.6V
12.2V
12.0V 11.1V 10.6V ----

13.2V 12.6V
12.2V
12.0V 11.1V 10.6V 120

9~17V 9~17V
9~17V
9~17V 9~17V 9~17V 0~180

Boost Duration (min.)

120

120

120 10~180

NOTE: 1) When the battery type is sealed, gel, flooded, the adjusting range of equalizing
duration is 0 to180min, and boost duration is 10 to180min.
2) The following rules must be observed when modifying the value of the parameter in
user battery type (factory default value is the same as sealed type): A. Over Voltage Disconnect Voltage > Charging Limit Voltage  Equalize Charging Voltage  Boost Charging Voltage  Float Charging Voltage > Boost Reconnect

Charging Voltage.
B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage  Discharging

Limit Voltage. D. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage 

Discharging Limit Voltage. Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.

2)Lithium Battery Control Voltage Parameters The parameters are in the 12V system

at 25 ºC; please double the values in the 24V system.

Battery type

LiFePO4 (4S) Li-NiCoMn User

Voltage parameter

(3S)

Over Voltage Disconnect Voltage

15.6V

13.5V

917V

Charging Limit Voltage

14.6V

12.6V

917V

Over Voltage Reconnect Voltage

14.5V

12.5V

917V

Equalize Charging Voltage

14.5V

12.5V

917V

Boost Charging Voltage

14.5V

12.5V

917V

Float Charging Voltage

13.8V

12.2V

917V

Boost Reconnect Charging Voltage

13.2V

12.1V

917V

Low Voltage Reconnect Voltage

12.4V

10.5V

917V

Under Voltage Warning Reconnect

12.5V

11.0V

917V

Voltage Under Volt. Warning Voltage

12.0V

10.5V

917V

Low Volt. Disconnect Voltage

11.0V

9.3V

917V

Discharging LimitVoltage

10.8V

9.3V

917V

The following rules must be observed when modifying the parameter values in User for the

lithium battery.

www.solarv.de

Copyright © 2021 SolarV GmbH

EN
A.Over Voltage Disconnect Voltage>Over charging protection voltage(Protection Circuit Modules(BMS))+0.2V; B.Over Voltage Disconnect Voltage>Over Voltage Reconnect VoltageCharging Limit Voltage  Equalize Charging VoltageBoost Charging Voltage  Float Charging Voltage>Boost Reconnect Charging Voltage; C.Low Voltage Reconnect Voltage>Low Voltage Disconnect Voltage  Discharging Limit Voltage; D.Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage Discharging Limit Voltage; E.Boost Reconnect Charging voltage> Low Voltage Reconnect Voltage; F.Low Voltage Disconnect Voltage  Over-discharging protection voltage (BMS)+0.2V.
WARNING: The voltage parameters of the lithium battery can be set, but you must refer to the voltage parameters of lithium battery BMS.
WARNING: The required accuracy of BMS shall be at least 0.2V. If the deviation is higher than 0.2V, the manufacturer will assume no liability for any system malfunction caused by this.
6.6 Fault indication

 No alarm for limited voltage fault when using Lithium batteries.

www.solarv.de

Copyright © 2021 SolarV GmbH

EN

7. Technical Specifications

Model Apply to model Self-consumption(Power on) Self-consumption(Power off) Communication way Communication port RS485 cable
Environment temperature Storage temperature range Enclosure Dimension Base cover dimension Weight

MT11 DRN series 13mA/5Vdc 4mA RS485 3.81-4P CC-RS485-RS485-3.81-4P150(1.5m) CC-RS485-RS4853.81-4P-500(5m) CC-RS485RS485-3.81-4P-1000(10m) -20+70 -20+70 IP20 98.4×98.4mm 114×114mm 0.11kg

www.solarv.de

SolarV GmbH www.solarv.de info@solarv.de
Copyright © 2021 SolarV GmbH



References