Instruction Manual for solarV models including: MT11, Remote Display Meter for the DuoRacer Solar Controller
EN www.solarv.de Copyright © 2021 SolarV GmbH Boost Reconnect Charging Voltage 13.2V 13.2V 13.2V 9~17V
File Info : application/pdf, 17 Pages, 832.77KB
DocumentDocumentINSTRUCTION MANUAL Remote Meter: MT11 EN Important Safety Instructions Thank you for selecting the remote meter. General safety information Please contact our company or transportation if the product has been damaged. Please read this manual carefully before using the product and pay attention to the safety information. Keep the product away from rain, exposure, severe dust, vibrations, corrosive gas and intense electromagnetic interference. Do not allow water to enter the product. There are no user serviceable parts inside the product. Do not disassemble or attempt to repair it. Recommendations The MT11 is only allowed to connect with DR-N series charge controller. Please confirm before purchase and installation. Please do not install MT11 in a situation with strong electromagnetic interference. www.solarv.de Copyright © 2021 SolarV GmbH EN Contents 1.Overview ............................................................................................ 2 2.Product classification ......................................................................... 3 3. Installation ........................................................................................ 4 3.1 Base of MT11 (Optional accessory) .......................................... 4 3.2 Wall installation steps ............................................................... 5 3.3 Surface mounting steps ............................................................ 7 4.Product Features ............................................................................... 8 4.1 Front View ................................................................................ 8 4.2 Rear View ................................................................................. 9 5.Display and operation ...................................................................... 11 5.1LCD display ............................................................................. 11 5.2 Auto global view mode ............................................................ 12 5.3 Temperature units ................................................................... 14 5.4 Clear the generated energy .................................................... 14 5.5 Battery type ............................................................................ 15 5.6 Fault indication ....................................................................... 19 6.Technical Specifications ..................... 20 www.solarv.de Copyright © 2021 SolarV GmbH EN 1. Overview The MT series remote meter is an accessory which is compatible with the DuoRacer series controller. It can monitor the running data and working status of the controller via the remote meter. The remote meter can browse the controller's parameters, set the battery type and temperature unit, and clean the generated energy. It is suitable for RV, Camper, Boat, and so on. Features Automatically identify and display the type, model and relevant parameter data of controllers. Real-time display the operational data and working status of the connected devices in digital, graphics and textual forms by a large-screen multifunction LCD. Three touch buttons are easy and quick to operate. No need for external power supply. Charge controller supplies the power for MT11. It can browse the controller's parameters, set the battery type and temperature unit, and clean the generated energy. Real-time display of failure information of the connected devices. Longer communication distance based on RS485. www.solarv.de Copyright © 2021 SolarV GmbH EN 2. Product classification 1) MT11(include the 1.5m communication cable) Remote meter MT11 1.5m communication cable (Model: CC-RS485-RS485-3.81-4P-150) Base of MT11 2) MT11 (include the 5m communication cable) Remote meter MT11 5m communication cable (Model: CC-RS485-RS485-3.81-4P-500) Base of MT11 3) MT11 (include the 10m communication cable) Remote meter MT11 10m communication cable (Model:CC-RS485-RS485-3.81-4P-1000) Base of MT11 4) MT11(Do not include the communication cable) Remote meter MT11 1.5m communication cable (Model: CC-RS485-RS485-3.81-4P-150) Do not include Base of MT11 NOTE: The user can purchase the product according to the requirement. www.solarv.de Copyright © 2021 SolarV GmbH EN 3. Installation 3.1 Base of MT11 (Optional accessory) Mechanical parameter Overall dimension Mounting dimension Terminal Parameter 114 x 114 x 44.41mm 88.6 x 88.6mm 5 3.2 Wall installation steps Step1: Locate and drill screw holes based on the Frame Mounting dimension of the base, and erect the plastic expansion bolts. www.solarv.de Copyright © 2021 SolarV GmbH EN Step2: Use four PA4.2×32 self-tapping screws to fix the Frame. Step3: Remove the decorative shell. Step4: Use four M4×8 pan head screws to mount MT11 Surface on the Frame. Step5: Install the decorative shell. 3.3 Surface mounting steps www.solarv.de Copyright © 2021 SolarV GmbH EN Step1: Locate and drill screw holes based on the installation size of the surface. Step2: Remove the decorative shell Step3: Use four M4×8 cross recessed pan head screws with M4 nuts to mount MT11 surface onto the panel. Step4: Install the decorative shell NOTE: Take full consideration of the plugging/unplugging space of the communication cable and the length of the cable during installation to see if they are appropriate. www.solarv.de Copyright © 2021 SolarV GmbH EN 4. Product Features 4.1 Front View LCD display screen Man-machine interaction operation interface. Refer to the chapter 5 Display and Operation. Buttons The meter buttons include two function buttons and one switch button. Press the button Press the button Press the button and hold on 5s Press the button Press the button and hold on 5s 1.PV array parameters 2.Storage battery parameters 3.Browse the start battery parameters automatically ( ) Browse the PV array parameters Browse the Storage battery parameters Browse the start battery parameters Temperature units Battery type The meter is powered ON The meter is powered OFF www.solarv.de Copyright © 2021 SolarV GmbH EN 4.2 Rear View RS485 communication port It is used to connect the controller which powers the MT11. Communication cable's models CC-RS485-RS485-3.81-4P-150(Included) CC-RS485-RS485-3.81-4P-1000(Optional) CC-RS485-RS485-3.81-4P-2000(Optional) Pins definition PIN 1 2 3 4 Definition DC5V RS-485-B RS-485-A GND www.solarv.de Copyright © 2021 SolarV GmbH EN 5. Display and Operation 5.1 LCD Display Icon Instruction Icon BATT1 battery capacity level012% Instruction BATT2battery capacity level012% BATT1battery capacity level13%35% BATT1battery capacity level36%61% BATT1battery capacity level62%86% BATT1battery capacity level 87%100% Day Night Display the parameters of PV Display the parameters of BATT1 BATT2battery capacity level13%35% BATT2battery capacity level36%61% BATT2battery capacity level62%86% BATT2battery capacity level 87%100% PV array BATT1 charging icon BATT2 charging icon BATT1temperature parameters www.solarv.de Copyright © 2021 SolarV GmbH Display the parameters of BATT2 Setting icon Auto global view sign Fault Icon EN AES signal icon Battery type icon Minimum voltage icon Maximum voltage icon Battery power capacity is calculated by the linear relationship between the disconnect voltage of low voltage and float charging voltage. 5.2 Auto Global View Mode Operation: Step1: Press the Step2: Press the button, appears. button, select the . Echo LoopPV voltage --PV current --PV power--Battery power--BATT1 voltage-- BATT1 current--Max. BATT1 voltage--Min.BATT1 voltage--BATT1 temperature-- www.solarv.de Copyright © 2021 SolarV GmbH EN BATT1 battery type--BATT2 voltage--BATT2 current--Max. BATT1 voltage-- Min.BATT2 voltage--PV voltage 5.3 Temperature units Operation: Step1: Press the Step2: Press the Step3: Press the button under the battery temperature interface. button to select the temperature unit. button to set successfully. 5.4 Clear the generated energy Press the and button and hold on 5s to clear the generated energy. www.solarv.de Copyright © 2021 SolarV GmbH EN 5.5 Battery type 1)Operation: Step1: Press the Step2: Press the Step3: Press the 2) Battery type button and hold 5s under the battery type interface. button when the battery type interface is flashing. button to confirm the battery type. BATT112V Sealed BATT112V Gel BATT112V Flooded LiFePO4(4S) Li-NiCoMn (3S) User BATT124V Sealed BATT124V Gel BATT124V Flooded LiFePO4(8S) Li-NiCoMn (6S) CAUTION: The battery voltage is set as default and not changeable when selecting the default battery type. Please change to "User" battery type before adjusting the battery voltage. CAUTION: Set the voltage of the "User" battery type via PC software only. 1) Lead-acid Battery Control Voltage Parameters The parameters are in the 12V system at 25 ºC. Please double the values in the 24V system. Battery type Voltage parameter Over Voltage Disconnect Voltage Sealed 16.0V Gel Flooded User 16.0V 16.0V 9~17V Charging Limit Voltage 15.0V 15.0V 15.0V 9~17V Over Voltage Reconnect Voltage 15.0V 15.0V 15.0V 9~17V Equalize Charging Voltage Boost Charging Voltage 14.6V 14.4V ---- 14.2V 14.8V 14.6V 9~17V 9~17V Float Charging Voltage 13.8V 13.8V 13.8V 9~17V www.solarv.de Copyright © 2021 SolarV GmbH EN Boost Reconnect Charging Voltage Low Voltage Reconnect Voltage Under Voltage Warning Reconnect Voltage Under Volt. Warning Voltage Low Volt. Disconnect Voltage Discharging Limit Voltage Equalize Duration (min.) 13.2V 12.6V 12.2V 12.0V 11.1V 10.6V 120 13.2V 12.6V 12.2V 12.0V 11.1V 10.6V ---- 13.2V 12.6V 12.2V 12.0V 11.1V 10.6V 120 9~17V 9~17V 9~17V 9~17V 9~17V 9~17V 0~180 Boost Duration (min.) 120 120 120 10~180 NOTE: 1) When the battery type is sealed, gel, flooded, the adjusting range of equalizing duration is 0 to180min, and boost duration is 10 to180min. 2) The following rules must be observed when modifying the value of the parameter in user battery type (factory default value is the same as sealed type): A. Over Voltage Disconnect Voltage > Charging Limit Voltage Equalize Charging Voltage Boost Charging Voltage Float Charging Voltage > Boost Reconnect Charging Voltage. B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage Discharging Limit Voltage. D. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage Discharging Limit Voltage. Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage. 2)Lithium Battery Control Voltage Parameters The parameters are in the 12V system at 25 ºC; please double the values in the 24V system. Battery type LiFePO4 (4S) Li-NiCoMn User Voltage parameter (3S) Over Voltage Disconnect Voltage 15.6V 13.5V 917V Charging Limit Voltage 14.6V 12.6V 917V Over Voltage Reconnect Voltage 14.5V 12.5V 917V Equalize Charging Voltage 14.5V 12.5V 917V Boost Charging Voltage 14.5V 12.5V 917V Float Charging Voltage 13.8V 12.2V 917V Boost Reconnect Charging Voltage 13.2V 12.1V 917V Low Voltage Reconnect Voltage 12.4V 10.5V 917V Under Voltage Warning Reconnect 12.5V 11.0V 917V Voltage Under Volt. Warning Voltage 12.0V 10.5V 917V Low Volt. Disconnect Voltage 11.0V 9.3V 917V Discharging LimitVoltage 10.8V 9.3V 917V The following rules must be observed when modifying the parameter values in User for the lithium battery. www.solarv.de Copyright © 2021 SolarV GmbH EN A.Over Voltage Disconnect Voltage>Over charging protection voltage(Protection Circuit Modules(BMS))+0.2V; B.Over Voltage Disconnect Voltage>Over Voltage Reconnect VoltageCharging Limit Voltage Equalize Charging VoltageBoost Charging Voltage Float Charging Voltage>Boost Reconnect Charging Voltage; C.Low Voltage Reconnect Voltage>Low Voltage Disconnect Voltage Discharging Limit Voltage; D.Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage Discharging Limit Voltage; E.Boost Reconnect Charging voltage> Low Voltage Reconnect Voltage; F.Low Voltage Disconnect Voltage Over-discharging protection voltage (BMS)+0.2V. WARNING: The voltage parameters of the lithium battery can be set, but you must refer to the voltage parameters of lithium battery BMS. WARNING: The required accuracy of BMS shall be at least 0.2V. If the deviation is higher than 0.2V, the manufacturer will assume no liability for any system malfunction caused by this. 6.6 Fault indication No alarm for limited voltage fault when using Lithium batteries. www.solarv.de Copyright © 2021 SolarV GmbH EN 7. Technical Specifications Model Apply to model Self-consumption(Power on) Self-consumption(Power off) Communication way Communication port RS485 cable Environment temperature Storage temperature range Enclosure Dimension Base cover dimension Weight MT11 DRN series 13mA/5Vdc 4mA RS485 3.81-4P CC-RS485-RS485-3.81-4P150(1.5m) CC-RS485-RS4853.81-4P-500(5m) CC-RS485RS485-3.81-4P-1000(10m) -20+70 -20+70 IP20 98.4×98.4mm 114×114mm 0.11kg www.solarv.de SolarV GmbH www.solarv.de info@solarv.de Copyright © 2021 SolarV GmbH