Instructions for RS models including: 233-3534, Pro Multi-Function Panel Meter, 233-3534 Pro Multi-Function Panel Meter
RS PRO Prozessanzeige für Strom, Spannung H 92mm B 45mm 4-Stellen T. 65mm | RS
File Info : application/pdf, 10 Pages, 1.96MB
DocumentDocumentInstruction RS PRO Multi-Function Panel Meter Process Indicator Stock No: see below ENGLISH RoHS PROCESS INDICATOR : (48*96) Ordering Information: Sr.No CAT No. Description 1 180 to 270 VAC, Process Indicator, Analog Input 233-3534 (0-10VDC / 4-20mA) 2 233-3538 180 to 270 VAC, Process Indicator, Thermocouple & RTD input CAT No: 233-3534W & 233-3538W (Where W stands for White display) NOTE: Ø The technical information provided in this document was correct at the time of publish. Ø Product innovation being a continuous process, we reserve the right to alter specications without any prior notice. TECHNICAL SPECIFICATION: 233-3538/ 233-3534 Supply Characteristics: Supply Voltage (Un) 180 to 270VAC Supply Frequency 47 / 63 Hz Power Consumption 5 VA max @ 230 VAC Functional Characteristics: PRODUCT DESCRIPTION: Process Indicator 233-3534 and 233-3538 helps to indicate temperature, Flow, Level, RPM. Monitors the process by accepting inputs from sensor or from analog signals in process industries, with inbuilt hour meter functionality. FEATURES: Ø Flush Mounting Version 48X96 mm with 7 segment display Ø Thermocouple (J, k, T, R & S)/ RTD 3-wire (PT-100) sensor input Ø Analog Input (0-10VDC/ 0-20mA/ 4-20mA) Ø °C & °F temperature unit selectable Ø Short depth of 65mm Ø IP 20 (For terminal), IP 30 (For enclosure) & IP 65 (For Front Panel) Ø Hour meter counter functionality Ø Automatic Decimal Point Adjust Menu Password Sensor Measurement Range 60 Default (User Selectable) Applicable for Cat_id: PIT200 J-type K-type T-type R-type & S-type RTD (Pt-100) °C -200 to 950 °F -328 to 1742 °C -200 to 1350 °F -328 to 2462 °C -200 to 400 °F -328 to 752 °C -200 to 850 °F -328 to 1562 °C 0 to 1750 °F 32 to 3182 Analog Input: Applicable for Cat_id: PIA200 CAUTION: Voltage 0 to 10VDC Ø When extending the thermocouple lead wires always use thermocouple compensation Ø wires for wiring. Ø For RTD sensor, use a wiring material with a small lead resistance (10O max per lead) Ø & no resistance differentials among 3 wires. Ø For 2 wire RTD sensor Short terminal RTD2 & RTD3 then connect to the Devices. Ø Clean the product with a soft and clean cloth. Do not use isopropyl alcohol or any Ø other cleaning agent. Ø 20 min warm-up time after connecting thermocouple input. Ø When replacing the sensor, please turn OFF the power. Ø Product innovation being a continuous process, we reserve the right to alter Ø specications without any prior notice. Ø Ensure the congure and connected input Sensor are same. Current 0 to 20mA, 4 to 20mA J, K, T & Pt-100 0.1°/1° Resolution R & S 1° Analog inputs 1/0.1/0.01/0.001 RTD ±0.1% of F.S ± 1°C 233-3538 J, K & T ±0.25% of F.S ± 1°C R & S ±0.5% of F.S ± 2°C Measurement Accuracy 233-3534 Signal input 0.5% of F.S Temperature Unit °C/°F selectable (Appliable for PIT200) Signal Sampling Time 168 ms SUITABILITY FOR USE: Display Seven Segment Display (Red Color) These are products with Auto reset, hence never use the products for an application involving signicant risk to life without ensuring that the system as a whole has been designed to address the risks and that Front Keypad 4 Keys as ESC ( ), DOWN ( ), UP ( ), ENTER ( ) our products are properly rated and installed for the intended use within the entire system or equipment. Key de-bounce time 40 ms 1 52LL001_00 TECHNICAL SPECIFICATION: Functional Characteristics: 233-3538 / 233-3534 J, K, T & Pt-100 0.1°/1° Resolution R & S Analog inputs 1° 1/0.1/0.01/0.001 RTD ±0.1% of F.S ± 1°C Measurement Accuracy PIT200 J, K & T R & S ±0.25% of F.S ±0.5% of F.S ± 1°C ± 2°C PIA200 Signal input 0.5% of F.S Temperature Unit °C/°F selectable (Appliable for PIT200) Signal Sampling Time 168 ms Display Seven Segment Display (Red Color) Front Keypad 4 Keys as ESC ( ), DOWN ( ), UP ( ), ENTER ( ) Key de-bounce time 40 ms Error Indications Sens Sensor open/Break error ovrg Over range error unrg Under range error Environmental Characteristics: Operating Temperature Storage Temperature 0 to 50 °c -20 to 75 °c Operating Humidity 85 % RH (Non-Condensing) Operating Altitude 2000 m (max) Pollution Degree II IP 20: Terminal Degree of Protection IP 65: Front Facial IP 30: Enclosure Enclosure Flame Retardant (UL 94 V-0) Other Characteristics: Mounting (WXHXD) mm 48X96X65 Weight (Un-Packed) PIA200 : 144 gm PIT200 : 145 gm Operating Position Horizontal (Readable) rspro.com FUNCTIONAL PARAMETERS: Parameter Inp Menu: Input Description senS Sensor input setting j J-type K-type S y S-type r r-type t T-type Default j Pt1 Pt-100 rAte ofst RATE Range: 0.000 to 2.000 OFFSet Range: -1999 to 9999 DP Decimal Point Range: 0 to 1 for J, K, Pt1 & T 0 for R, S unIt Filt Temperature Unit Range: °C or °F Filter Range: 0 to 10 misc Menu: Miscellaneouc unit hcnt Unit Range: OFF,day,hr hcth Counter Threshold Range: OFF to 9999 This Parameter will displays the Current Ver Product Firmware Version pwd Menu: Password stat Password Status Range: EN or DIS EN: Enable DIS: Disable set Password Set Range: 0 to 9999 Hide Menu: Hiding Input Range: OFF or ON inp OFF: Inp menu will not hide ON: Inp menu will hide Misc Miscellaneouc Range:OFF or ON OFF: Misc menu will not hide ON: Misc menu will hide 1.000 0 0 o C 0 oFF oFF ... En 60 off off Parameter Description pwd Menu: Password Password Pwd Range: OFF or ON OFF: PWD menu will not hide ON: PWD menu will hide rset Reset Range: OFF or ON OFF: Rset menu will not hide ON: Rset menu will hide rset Menu: Reset rset Reset To reset the devices & load default setting (Press Enter key) Default off off cnfm If "Yes": Will display Conrm reset If "No" : Will get to menu no After Conrm, If "Yes": Devices Reset and back to main Screen If " No": Back to main Screen 2 The Functional parameter for cat_id: 233-3534 is same as above only input menu is different Inp Menu: Input senS Sensor input setting 0_20 0 to 20mA 4_20 4 to 20mA 0_10 0 to 10VDC 0_20 Analog Input Low Scale IScL Range: -1999 to ISCH 0 Selectable low value for analog input isch Analog Input High Scale Range: ISCL to 9999 Selectable high value for analog input 100.00 airl airH rAte ofst DP Filt Analog Input Range Low Range: For 0_20: 0 to AirH For 4_20: 4 to AirH For 0_10: 0 to AirH Selectable low value for Display scaling Analog Input Range High Range: For 0_20: AirL to 20 For 4_20: AirL to 20 For 0_10: AirL to 10 Selectable high value for Display scaling RATE Range: 0.000 to 2.000 OFFSet Range: -1999 to 9999 Decimal Point Range: 0 to 3 for V & I Filter Range: 0 to 10 00.00 20.00 1.000 0 0 2 EMI/EMC Compliance: Harmonic Current Emission ESD Radiated Susceptibility Electrical Fast Transients (Power Ports) Surge IEC 61000-3-2 (Class A) IEC 61000-4-2 (Level III) IEC 61000-4-3 (Level III) IEC 61000-4-4 (Level IV) IEC 61000-4-5 (Level IV) Conducted Susceptibility IEC 61000-4-6 (Level III) Power Frequency Magnetic Field IEC 61000-4-8 (Class 4) Voltage Dips/Interruption IEC 61000-4-11 Voltage Dips (DC) IEC 61000-4-29 Conducted & Radiated Emission CISPR 11 (Class A) Product Standard Safety Compliance: Dielectric Strength (Input & Output) IEC 61326-1 IEC 60255-5 Impulse(Input & Output) IEC 60255-5 (Level IV) Single Fault IEC 61010-1 Insulation Resistance Leakage Current UL 508 (>100 M) UL 508 (< 3 mA) Environmental Compliance: Cold Heat Dry Heat Vibration IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-6 (5g) CONNECTION DETAIL: DC Analog Input V mA + -- + 1 2 3 4 5 6 7 8 9 10 21 23 22 233-3534 24 11 12 13 14 15 16 17 18 19 20 Pt-100 RTD1 RTD2 RTD3 + TC/mV 1 2 3 4 5 6 7 8 9 10 21 22 233-3538 23 24 11 12 13 14 15 16 17 18 19 20 NL Input Supply NL Input Supply FRONT FACIA: 1 6 2 5 Sr. Keys/ No. Indication 1 PV 2 3 4 5 6 °F 3 4 Description To displays the `Process Value' & `Menu'. To exit from menu. To abort changed value or parameter. To return to home screen. To view parameter downward. To decrement/ change parameter value in edit mode. To view hour counter unit & threshold (Press for >2 sec ) To view parameter upward. To increment/change parameter value in edit mode. To enter into main menu (Press for >2 sec ) To select and save parameter To indicates LED `°F' unit setting. MECHANICAL DIMENSIONS (in mm): FRONT VIEW SIDE VIEW PANEL CUTOUT Terminal Details: Ø4......5.0mm Combi Head Bit./Flat AWG 0.5 N.m (4.4lb.in) to 0.7N.m (6.2lb.in) 2 x 2.5 mm2 Solid / Standard Wire 1 X 20 to 12 rspro.com 3 FUNCTION MENU: Cat_id: 233-3538 60 pwd Press Enter key for 2 sec (60 is password) 1np SenS rate oFSt DP UnIt J 1.000 0 0 oC y of s r T pt1 misc Unit off hcnt off pwd stat SET Dis 60 Hide inp misc PWD rset off off rset no yes off off cnF no yes filt 2 Cat_id: 233-3534 60 pwd Press Enter key for 2 sec (60 is password) 1np SenS iSCL isch airl airh 0_20 4_20 0 100 00.00 20.00 filt DP oFSt rate 0_10 misc Unit 2 off 0 0 1.000 hcnt off pwd stat SET Dis 60 Hide inp misc PWD rset off off rset no yes off off cnF no yes DESCRIPTION & DEFINATION: Rate (rate) & Offset (ofst): This menu is used to adjust the PV value in cases where it is necessary for PV value to agree with another recorder or indicator, or when the sensor cannot be mounted in correct Location. E.g. Sensor is mounted at a location, where less than actual temperature is observed. Let us say actual temperature is 550 and sensor is located to such a location where the temperature is 500.This device will measure 500 and show the value accordingly. To observe the actual temperature, user should add offset of 50 to measured temperature value. i.e. 500+50=550. Now device will show 550 instead of 500, Rate can be applied as slope; range is from 0.001 to 2.000. Display temp. = rAtE * Measured Temp + oFst HOUR METER: It is the number of hour/day that the instrument is turned ON. When the DUT reached to the threshold value (Programmable) the display will indicate an message of "INSP"(Inspection), to indicated that set threshold is completed and can start his necessary action. After acknowledge the hour meter will continue to record the hours till new threshold is set. If counter threshold is edited then it will reset the current count. UNIT (UNIT): It is used to select day or hour. HOUR METER THRESHOLD (hcNT): It is used to set the threshold. ANALOG INPUT & DISPLAY SETTING E.g. We have few setting in Inp menu. Sens = 0_10 (0V to 10V) AlrL = 1, Alrh = 10, (Selectable high & low value for analog input) IScL = 0, ISch = 99 (Selectable high & low value for Display scaling value) When analog input voltage is 1V then value on display will be 0. When analog input voltage is 10V, then value on display will be 99.This value will vary from 0 to 99 according to analog input. E-Waste Regulatory notice: Kindly treat, recycle or dispose of this equipment in an environmentally sound manner after End of Life, as per WEEE (Waste and Electronic Equipment) regulations; or hand it over to General Industrial Controls Pvt. Ltd, through website https://www.gicindia.com/get-intouch/ 4 rspprco.cmom PROCESS INDICATORS : (48*96) RoHS Ordering Information: FRONT FACIA: Sr.No CAT No 1 233-3535 Description 85-270V AC/DC, Process indicator, Analog Input (0-10VDC/0-20mA),Thermocouple, RTD & mV, 24VDC Sensor Supply 85-270V AC/DC, Process indicator, Analog Input 2 233-3536 (0-10VDC/0-20mA),Thermocouple, RTD & mV, Alarm outputs-Analog (0-10V/0-5V,0-20mA/4-20mA) & Relay 5A for alarm indication, 24VDC Sensor Supply) 85-270V AC/DC, Process indicator, Analog Input 3 233-3537 (0-10VDC/0-20mA),Thermocouple, RTD & mV, Alarm outputs-Analog (0-10V/0-5V,0-20mA/4-20mA) & Relay 5A for alarm indication with Rs485 Modbus communication, 24VDC Sensor Supply) CAT No: PIB110W, PIB120W & PIB12CW (Where W stands for White display) PRODUCT DESCRIPTION: Process indicator Series with scalable analog input and output, monitors the process, indicates the temperature, level, ow and pressure, retransmits the analog output, provides alarm indication, with inbuilt hour meter functionality and RS485 Modbus communication. FEATURES: Ø Flush Mounting Version 48X96 mm with 7 segment display Ø Thermocouple (J, k, T, R & S)/ RTD 3-wire (PT-100) sensor input Ø Analog Input (0-10VDC/ 0-20mA/ 4-20mA), mV(Linear) -5 to 56mV Ø Alarm Outputs, Analog (0-20mA/ 4-20mA or 0-10VDC/0-5VDC) and Ø Relay 5A for alarm indication Ø Congurable Band, Deviation Alarms Ø °C & °F temperature unit selectable Ø Short depth of 65mm Ø RS485 Communication (applicable for Cat No: PIB12C) Ø IP 20 (For terminal), IP 30 (For enclosure) & IP 65 (For Front Panel) Ø 24 VDC (30mA) sensor supply Ø Hour meter counter functionality Ø Automatic Decimal Point Adjust 1 2 6 7 8 5 Sr. Keys/ No. Indication 1 PV 2 3 4 5 6 AL1 7 AL2 8 °F 3 4 Description To display the `Process Value' & `Menu'. To exit from menu. To abort changed value or parameter. To return to home screen. To view parameter upward. To increment/change parameter value in edit mode. To view parameter downward. To decrement/change parameter value in edit mode. To view hour counter unit & threshold(Press for >2 sec ) To enter into main menu (Press for >2 sec ) To select and save parameter To indicate LED for Alarm 1. To indicate LED for Alarm 2. To indicate LED `°F' unit setting. FRONT VIEW SIDE VIEW AL1 AL2 CAUTION: Ø When extending the thermocouple lead wires, Always use Ø thermocouple compensation wires for wiring. Ø For 2 wire RTD short terminal RTD2 & RTD3 and then connect to the devices. Ø Clean the product with a soft and clean cloth. Do not use isopropyl alcohol or any other cleaning agent. Ø 20 min warm-up time after connecting thermocouple input Ø When replacing the sensor, please turn OFF the power. Ø Product innovation being a continuous process, we reserve the right to alter specications without any prior notice. Ø Ensure the congure and connected input Sensor are same. Ø For RTD sensor, Use a wiring material with small Lead resistance Ø (100O max per lead) & no resistance differentials among 3 wires MECHANICAL DIMENSIONS (in mm): PANEL CUTOUT Terminal Details: Ø4......5.0mm Combi Head Bit./Flat AWG 0.5 N.m (4.4lb.in) to 0.7N.m (6.2lb.in) 2 x 2.5 mm2 Solid / Standard Wire 1 X 20 to 12 52LL002_00 1 rspprco.cmom TECHNICAL SPECIFICATION: Supply Characteristics: 233-3535 / 233-3536 Supply Voltage (Un) Supply Frequency Power Consumption 85 to 270 VAC/DC 47 to 63 Hz 8 VA @ 230 VAC / PIB12C Functional Characteristics: Menu Password Sensor Inputs (IEC) Sensor Measurement Range 60 Default (User Selectable) Thermocouple (J, K, T, R & S) RTD (Pt-100, 3-wire, 2-wire) For 2 wire RTD short terminal no 6 & 7 J-type °C -200 to 950 °F -328 to 1742 K-type T-type R-type & S-type °C -200 to 1350 °F -328 to 2462 °C -200 to 400 °F -328 to 752 °C 0 to 1750 °F 32 to 3182 RTD (Pt-100) °C -200 to 850 °F -328 to 1562 Analog Input Voltage Current 0 to 10VDC 0 to 20mA, 4 to 20mA Resolution mV -5 to 56mV J, K, T & Pt-100 0.1°/1° R & S 1° Analog inputs 1/0.1/0.01/0.001 RTD ±0.1% of F.S ± 1°C Measurement Accuracy J, K & T R & S Signal input ±0.25% of F.S ±0.5% of F.S 0.5% of F.S ± 1°C ± 2°C 20 min warm up Temperature Unit °C/°F selectable Signal Sampling Time 168 ms Display Seven Segment Display (Red Color) Front Keypad 4 Keys as ENTER ( ), UP ( ), DOWN ( ), ESC ( ), Key de-bounce time 40 ms Error Indications Sens Sensor open/Break error Ovrg Over range error Unrg Under range error Sensor Supply Characteristics: Output Voltage 24 VDC (26.4 V Max.) Load Current 30 mA (Max) Relay(Alarm Indication) Characteristics: Applicable for cat No: PIB120 and PIB12C Contact Arrangement 1 C/O (SPDT) Contact Rating 5A(NO), 3A(NC), RES. @ 250VAC/ 24VDC Contact Material Ag alloy (Cd free) Utilization Category (AC-15) Switching Frequency Ue Rated Voltage (V): 120 / 240 Ie Rated Current (A): 3.0 / 1.5 1800 Operations/Hour Electrical Life 50,000 Operations Mechanical Life 5,000,000 Operations Linear DC Output Characteristics: Applicable for cat No: PIB120 and PIB12C Programmable output Voltage: 0 to 10V/ 0 to 5V Current: 0 to 20 mA / 4 to 20mA Output update rate 100mS Accuracy of DC Output 0.25% of F.S. Min. load resistance (Voltage) Min 30K Max. load resistance (Current) Max 600 LED Indications(For Alarm Indication): AL1 and AL2 LED's are applicable for cat No: PIB120 and PIB12C AL1 (Red LED) ON AL2 (Red LED) ON Relay output ON Relay output ON `°F' (Red LED) ON Display `°F' value OFF Display `°C' value Communication Characteristics: Applicable for cat No: PIB12C Interface Standard RS-485 (Modbus RTU) Communication Address 1 to 247 Transmission Distance Upto 1000 m Transmission Speed 2400,4800, 9600, 19200 BPS Parity Even, Odd, None Communication Half Duplex Environmental Characteristics: Operating Temperature 0 to 50 °c Storage Temperature -20 to 75 °c Operating Humidity 85 % RH (Non-Condensing) Operating Altitude Pollution Degree 2000 m (max) II Degree of Protection Enclosure Other Characteristics: IP 20: Terminal IP 65: Front Facial IP 30: Enclosure Flame Retardant (UL 94 V-0) Mounting (HXWXD) Weight (Un-Packed) 48X96X65 (mm) 233-3535:160 gm 233-3536 :200 gm 233-3537 :200 gm Operating Position Horizontal (Readable) EMI/EMC Compliance: Harmonic Current Emission ESD IEC 61000-3-2 (Class A) IEC 61000-4-2 (Level II) Radiated Susceptibility IEC 61000-4-3 (Level III) Electrical Fast Transients (Power Ports) IEC 61000-4-4 (Level IV) Surge IEC 61000-4-5 (Level IV) Conducted Susceptibility IEC 61000-4-6 (Level III) Power Frequency Magnetic Field IEC 61000-4-8 (Class 4) Voltage Dips/Interruption IEC 61000-4-11 Voltage Dips (DC) IEC 61000-4-29 Conducted & Radiated CISPR 11 (Class A) Emission Product Standard IEC 61326-1 Safety Compliance: Dielectric Strength (Input & Output) IEC 60255-5 Impulse (Input & Output) IEC 60255-5 (Level IV) Single Fault IEC 61010-1 Insulation Resistance UL 508 (>100 M) Leakage Current UL 508 (< 3 mA) Environmental Compliance: Cold Heat IEC 60068-2-1 Dry Heat IEC 60068-2-2 Vibration IEC 60068-2-6 (5g) 2 ALARM MENU: Alarm Types: 1. Absolute low ("AbLO" on display): Alarm is activated if PV goes below A1th and is deactivated if PV goes above (A1th+A1hY). Menu AL1 Sub menu A1tY Option AbLo PV A1hY A1th+A1hY A1th ON OFF ON OFF ON Time 2. Absolute high ("AbhI" on display): Alarm is activated if PV goes above A1th and is deactivated if PV goes below (A1th-A1hy). Menu AL1 Sub menu A1tY Option Abhi PV A1hY A1th A1th-A1hY OFF ON OFF ON OFF Time 3. Absolute band ("AbbA" on display): Alarm is activated if PV goes above A1hi or below A1Lo. It is deactivated if it goes below (A1hi-A1hy) or above (A1Lo+A1hy). Menu AL1 Sub menu A1tY Options AbbA PV A1hY A1hy Menu AL1 ON O F F ON O F F ON O ON O ON F F F F A1hi A1hi-A1hy A1L0+A1hy A1Lo Time Sub menu A1tY Options AbLo AbhI AbbA AL Menu: This Menu is applicable for Cat No: PIB120 & PIB12C A1tY Alarm 1 type: Range: 1. AbLo: Absolute low 2. AbhI: Absolute high 3. AbbA: Absolute band AbLo Alarm 1 function: 0 : Alarm on Error +1: Acknowledge alarm A1Fn +2: Delayed alarm 0 +4: Latch alarm +8: No alarm at power on Range: 0-15 A1Lo A1th Alarm 1 low level Range: -1999 to A1th Alarm 1 Threshold Range: A1Lo to A1Hi -1999 0 A1hI A1hY Alarm 1 high level Range: A1th to 9999 Alarm 1 hysteresis Range: OFF to 9999 9999 1 Alarm 1 Annunciator Range: LED, DISP, OFF LED: LED blinks at 0.2 Sec A1AN after alarm occurrence DISP: Message gets displayed Off On Screen and LED gets ON after alarm occurrence OFF: LED is continuous ON A1dL Alarm 1 delay Range: OFF to 9999 s Off Alarm Functions: Sr.No Value Details Applications 10 21 32 44 58 Normal Activation: When alarm condition occurs. Deactivation: When the alarm condition Disappear. Acknowledge Activation: When alarm condition occurs. Deactivation: 1)When the alarm condition disappear. 2)When configurable key is programmed for acknowledgment and it is pressed in alarm condition. Normal To ignore the alarm Condition Delayed To delay the Activation: Delayed by time set in A1dL alarm parameter after occurrence of the alarm generated, condition. some times Deactivation: When the alarm condition alarm can be disappear. generated for Note: During the delay if the alarm shorter time condition disappears, alarm will not due to some generated. disturbance in system Latched To record or Activation: When alarm condition occurs. draw attention Deactivation: When configurable key is of alarm programmed for acknowledgment and generation it is pressed in alarm condition. condition every Note: Alarm will not automatically time. since no deactivated once generated. automatic of alarm No alarm at Power ON Activation: IF alarm condition exist at power on, alarm will not be activated. Once devices comes out of alarm condition after power on, there after alarm will be activated at every occurrence of the alarm condition. Deactivation: Alarm will be deactivated in no alarm condition. To avoid alarm after power on. Since possibility of alarm condition after every power on. Note: Alarm types and functions are explained for alarm 1. The explanation for AL1 is same as AL2. 2. Binary addition of alarm function allows Combination of different function. Eg. If it is required to have no alarm at power On [8] and Delayed [2], set function as 10. FUNCTIONAL PARAMETERS: Parameter Description Inp Menu: Input senS Sensor input setting j J-type S y K-type S-type r r-type t T-type Pt1 Pt-100 0_20 0 to 20mA 4_20 4 to 20mA 0_10 0 to 10VDC 56mV 56mV Analog input IScL Analog Input Low Scale Range: -1999 to ISCH Isch Analog Input High Scale Range: ISCL to 9999 airl Analog Input Range Low Range: For 0_20: 0 to AirH For 4_20: 4 to AirH For 0_10: 0 to AirH For 56mV: -5 to AirH airH Analog Input Range High Range: For 0_20: AirL to 20 For 4_20: AirL to 20 For 0_10: AirL to 10 For 56mV: AirL to 56 Default j 0 100 0.00 20.00 3 rAte RATE Range: 0.000 to 2.000 ofst OFFSet Range: -1999 to 9999 DP unIt Decimal Point Range: 0 to 3 for V, I & mV 0 to 1 for J, K, Pt1 & T 0 for R, S Temperature Unit Range: °C or °F PvLO PvhI Filt Process Value Low Range: -1999 to 9999 Corresponds to 0 or 4mA / 0VDC Process Value High Range: -1999 to 9999 Corresponds to 20mA / 10VDC Filter Range: 0 to 10 0p Menu: Output Output 1 Range: OFF A1NO(Alarm 1 Normally open) op1 A1NC(Alarm 1 Normally Close) A2NO(Alarm 2 Normally open) A2NC(Alarm 2 Normally Close) SMER(Sensor Measurement Error) Output 2 Range: OFF A1NO(Alarm 1 Normally open) op2 A1NC(Alarm 1 Normally Close) A2NO(Alarm 2 Normally open) A2NC(Alarm 2 Normally Close) SMER(Sensor Measurement Error) op3 manl Serr Output 3 Range: V005(0 to 5 VDC) V010(0 to 10 VDC) I020(0 to 20 mA) I420(4 to 20 mA) Manual mode Range: ON, OFF Sensor Error Range: Low, High (Note: the parameter will only be visible if manual mode is OFF) When ever sensor error conditions occurs in that case analog o/p will be High (for e.g 5 VDC) Ptag Percentage Error Range: 0.0 to 100.0 (Note: The parameter will only be visible if manual mode is ON) if PtAg: 50 & OP3: V005 then, When ever sensor error conditions occurs in that case analog o/p will be 2.5VDC (Percentage value of Analog o/P ) misc Menu: Miscellaneouc hcnt unit Unit Range: OFF,day,hr hcth Counter Threshold Range: OFF to 9999 This Parameter will displays the ver Current Product Firmware Version modb Menu: Modbus addr Address (Devices ID) Range: 1 to 247 1.000 0 0 oC 0 100 0 oFF oFF V005 off high 0 oFF oFF ... 1 baud Baud rate Range: 24, 48, 96, 192 24: 2400 baud rate 48: 4800 baud rate 96: 9600 baud rate 192: 19200 baud rate part Parity Range: None, Odd, Even None: None Parity odd : Odd Parity Even : Even parity Stpb Number of stop bits Range: 1 to 2 pwd Menu: Password stat Password Status Range: EN or DIS EN: Enable DIS: Disable set Password Set Range: 0 to 9999 Hide Menu: Hiding Input inp Range: OFF or ON OFF: Inp menu will not hide ON : Inp menu will hide Alarm1 Al1 Range: OFF or ON OFF: AL1 menu will not hide ON : AL1 menu will hide Al2 op Misc Alarm2 Range: OFF or ON OFF: AL2 menu will not hide ON : AL2 menu will hide Output Range: OFF or ON OFF: OP menu will not hide ON : OP menu will hide Miscellaneouc Range: OFF or ON OFF: Misc menu will not hide ON : Misc menu will hide Modb Modbus Range: OFF or ON OFF: Modb menu will not hide ON : Modb menu will hide Password Pwd Range: OFF or ON OFF: PWD menu will not hide ON : PWD menu will hide rset Reset Range: OFF or ON OFF: Rset menu will not hide ON : Rset menu will hide rset Menu: Reset rset cnfm Reset To reset the devices & load default setting (Press Enter key) If "Yes" : Will display Confirm reset If "No" : Will get to menu After Confirm, If "Yes" : Devices Reset and back to main Screen If " No" : Back to main Screen 96 none 1 En 60 off off off off off off off off no 4 rspro.com The Functional parameter for cat_id: PIA200 is same as above only input menu is different Inp Menu: Input senS Sensor input setting 0_20 4_20 0 to 20mA 4 to 20mA 0_10 0 to 10VDC IScL Analog Input Low Scale Range: -1999 to ISCH Selectable low value for analog input isch Analog Input High Scale Range: ISCL to 9999 Selectable high value for analog input 4_20 0 100.00 airl Analog Input Range Low Range: For 0_20: 0 to AirH For 4_20: 4 to AirH For 0_10: 0 to AirH Selectable low value for Display scaling 00.00 airH Analog Input Range High Range: For 0_20: AirL to 20 For 4_20: AirL to 20 For 0_10: AirL to 10 Selectable high value for Display scaling 20.00 MECHANICAL DIMENSIONS (in mm): FRONT VIEW SIDE VIEW PANEL CUTOUT Terminal Details: Ø4......5.0mm Combi Head Bit./Flat AWG 0.5 N.m (4.4lb.in) to 0.7N.m (6.2lb.in) 2 x 2.5 mm2 Solid / Standard Wire 1 X 20 to 12 rAte RATE Range: 0.000 to 2.000 ofst DP Filt OFFSet Range: -1999 to 9999 Decimal Point Range: 0 to 3 for V & I Filter Range: 0 to 10 CONNECTION DIAGRAM: Pt-100 DC Analog RTD1 RTD2 RTD3 Input + TC/mV - V mA + -- + 1 2 3 4 5 6 7 8 9 10 21 22 233-3535 23 24 11 12 13 14 15 16 17 18 19 20 + 24V - Sensor Supply N/- L/+ Input Supply OP3 RTD1 RTD2 RTD3 0-5V 0-20mA 0-10V 4-20mA Pt-100 DC Analog Input + - + + TC/mV - + V- mA - + 1 2 3 4 5 6 7 8 9 10 21 22 233-3536 23 24 11 12 13 14 15 16 17 18 19 20 NO NC P OP1 NO NC P OP2 + 24V - Sensor Supply N/- L/+ Input Supply OP3 0-5V 0-20mA 0-10V 4-20mA Pt-100 DC Analog Input + - + + TC/mV - V mA + -- + 1 2 3 4 5 6 7 8 9 10 + D 21 D- 22 233-3537 23 24 11 12 13 14 15 16 17 18 19 20 NO NC P OP1 NO NC P OP2 + 24V - Sensor Supply N/- L/+ Input Supply RS485 RTD1 RTD2 RTD3 1.000 0 0 2 FUNCTION MENU: 60 pwd Press Enter key for 2 sec (60 is password) 1np SenS rate oFSt DP UnIt J 1.000 0 0 oC y of s r T pt1 misc Unit off hcnt off pwd stat SET Dis 60 Hide inp misc PWD rset off off rset no yes off off cnF no yes filt 2 5 rspro.com Cat_id: 233-3534 60 pwd Press Enter key for 2 sec (60 is password) 1np SenS iSCL isch airl airh 0_20 4_20 0 100 00.00 20.00 filt DP oFSt rate 0_10 misc Unit 2 off 0 0 1.000 hcnt off pwd stat SET Dis 60 Hide inp misc PWD rset off off rset no yes off off cnF no yes DESCRIPTION & DEFINATION: Rate (rate) & Offset (ofst): This menu is used to adjust the PV value in cases where it is necessary for PV value to agree with another recorder or indicator, or when the sensor cannot be mounted incorrect Location. E.g. Sensor is mounted at a location, where less than actual temperature is observed. Let us say actual temperature is 550 and sensor is located to such a location where the temperature is 500.This device will measure 500 and show the value accordingly. To observe the actual temperature, user should add offset of 50 to measured temperature value.i.e. 500+50=550. Now device will show 550 instead of 500, Rate can be applied as slope; range is from 0.001 to 2.000. Display temp. = rAtE * Measured Temp + oFst HOUR METER: It is the number of hour/day that the instrument is turned ON. When the DUT reached to the threshold value (Programmable) the display will indicate an message of "INSP"(Inspection), to indicated that set threshold is completed and can start his necessary action. After acknowledge the hour meter will continue to record the hours till new threshold is set. If counter threshold is edited then it will reset the current count. UNIT (UNIT): It is used to select day or hour. HOUR METER THRESHOLD (hcNT): It is used to set the threshold. ANALOG INPUT & DISPLAY SETTING E.g. We have few setting in Inp menu. Sens = 0_10 (0V to 10V)AlrL = 1, Alrh = 10, (Selectable high & low value for analog input)IScL = 0, ISch = 99 (Selectable high & low value for Display scaling value) When analog input voltage is 1V then value on display will be 0. When analog input voltage is 10V, then value on display will be 99.This value will vary from 0 to 99 according to analog input. 6 rspro.com