User Manual for COREMORROW models including: E81.A1K Series Piezo Controller, E81.A1K Series, Piezo Controller, Controller
Piezo Controllers,Piezo Amplifiers,Piezo Drivers,Piezo Power Supply - CoreMorrow
File Info : application/pdf, 7 Pages, 474.30KB
DocumentDocumentE81.A1K Series Piezo Controller User Manual Version: V1.0 This document describes the following products: E81.A1KOpenloopcontroller1channel DECLARATION Declaration! This user manual is a integrated user manual of the E81.A1K series piezoelectric controller. Please read this user manual carefully before using this controller. Follow the instructions in the manual during use. If there is any problem, please contact us for technical support. If you do not follow this manual or disassemble and modify the product yourself, the company will not be liable for any consequences arising therefrom. Please read the following to avoid personal injury and to prevent damage to this product or any other product connected to it. In order to avoid possible hazards, this product can only be used within the specified range. Notice! Do not touch any exposed ends of the product and its accessories. There is high voltage inside. Do not open the case without permission. Do not connect or disconnect input, output, or sensor cables with power on. Please keep surface of E81.A1K clean and dry, don't operate in humid or static environment. After use, output voltage should be cleared to zero before turning off the controller switch, such as switching the servo state to the open-loop state. Danger! The piezoelectric power amplifier described in this manual is a high-voltage device capable of outputting high currents, which can cause serious or even fatal damage if not used properly. It is strongly recommended that you do not touch any parts that connect to the high voltage output. Special Note: If you connect it with other products in addition to our company, please follow the general accident prevention procedures. Operating the high-voltage amplification requires training professional operators. Warning! If the voltage exceeds the PZT's tolerable range, it will cause permanent damage to the PZT. Before adding voltage to the PZT poles, it must be ensured that the positive and negative poles of the PZT are connected correctly and the operating voltage is within the allowable range of this PZT. Cautious! E81.A1K housing should be installed on a horizontal surface in an area with a 3CM air flow area to prevent internal convection in the vertical direction. Insufficient airflow can cause equipment to overheat or premature instrument damage. Contents 1.Security .......................................................................................................................................... 2 1.1Introduction ........................................................................................................................... 2 1.2SafetyInstructions ............................................................................................................... 2 1.3Notes ....................................................................................................................................... 2 2.Introduction ................................................................................................................................. 3 2.1Features ................................................................................................................................. 3 2.2Applicaitons ........................................................................................................................... 3 3.DrivingPrinciple ........................................................................................................................... 4 4.NotesandSuggestions ............................................................................................................... 4 5.CustomerService ........................................................................................................................ 4 6.Contactus .................................................................................................................................... 5 E81.A1K Series Piezo Controller User Manual 1.Security 1.1Introduction PleasekeepsurfaceofE81.A1Kcleananddry. Donotoperateinthehumidorstaticenvironment. E81.A1Kisusedtodrivecapacitiveloads(suchaspiezoactuators). E81.A1Kshouldnotbeusedinusermanualsofotherproductsofthesamename. PayspecialattentionE81.A1Kcannotbeusedtodriveresistiveorinductiveloads. E81.A1Kcouldbeusedforstaticanddynamicoperatingapplications. 1.2SafetyInstructions E81.A1Kisbasedonthenationalsafetystandard.Improperusemaycausepersonalinjury or damage to the piezo controller. The operator is responsible for the correct installation andoperationofthepiezocontroller. Pleasereadtheusermanualindetail. Pleaseeliminateanyfaultsandpotentialsafetyhazardscausedbythefaults. If the protective ground wire is not connected or connected incorrectly, there will be a possibility of leakage. If you touch the E81.A1K piezo controller, it may cause serious or evenfatalinjuries. If the piezo controller housing is opened without permission, touching the live parts may cause electric shock , resulting in serious or even fatal injur y or damage to the piezo controller. Only authorized professional technicians with corresponding qualifications could openthepiezocontroller. WhenopeningE81.A1Kseriescontroller,pleasedisconnectthepowerplug. Pleasedonottouchanyinternalpartswhenoperatingunderbareconditions. 1.3Notes The contents in the user manual are all standard descriptions, and the customized parametersarenotexplainedindetailinthismanual. 2 ThelatestusermanualisavailablefordownloadonCoreMorrowwebsite. When operating the E81.A1K, the user manual should be placed near the system for easy reference in time. If the user manual is missing or damaged, please contact CoreMorrowcustomerservicedepartment. Pleasetimelyaddalltheinformationgiveninthemanufacturer'susermanual,such assupplementsortechnicaldescriptions. Ifyourusermanualisincomplete,itwillmissalotofimportantinformation,cause serious or fatal injuries, and cause property damage. Please read and understand the contentintheusermanualbeforeinstallingandoperatingtheE81.A1K. Only professionals who are authorized to meet the technical requirements could install,operate,maintainandcleantheE81.A1K. 2. Introduction 2.1Features Single-channelhighpower Output-20~150 Peakcurrent>6A Avecurrent2A±10% Unloadbandwidth10KHz Outputshortcircuitprotection 2.2Applicaitons Piezodriveandtest 3 E81.A1K Series Piezo Controller User Manual 3.Driving Principle Analog input Power amplification High voltage output PZT 4.Notes and Suggestions E81.A1K cannot be used to drive inductive loads. If the inductive loads are driven, theproductmaybedamaged. Do not switch the machine on and off frequently. It should be at least 30 seconds beforestartingitagain. Theinputshallbecutofforkepttozerobeforestarting. Maintainfrontandrearventilation. 5.Customer Service Ifyouhaveanyquestionsinuse,pleasetellusthefollowinginformation: Productmodelandrelevantnumber The controller model Softwaredriverversion Supportingcomputeroperatingsystem 4 6.Contact us Harbin Core Tomorrow Science & Technology Co., Ltd. Tel:+86-451-86268790 Email:info@coremorrow.com Website:www.coremorrow.com Address:BuildingI2,No.191XuefuRoad,NangangDistrict,Harbin,HLJ,China CoreMorrow Official and CTO WeChat are below: 5