Instruction Manual for SandP models including: FLEXEO BP FL 3V, FLEXEO BP RD 3V, FLEXEO 3V Series Static Heat Recovery Units, FLEXEO 3V Series, FLEXEO 3V Series Heat Recovery Units, Static Heat Recovery Units, Heat Recovery Units, Recovery Units
FLEXEO 3V – S&P – S&P
With its remote control, it is possible to manage the boost function, the bypass ... 4000. 8000. TOTAL dB(A). OUTLET. 2,4. 12. 15,5. 32,9. 17,6. 10,3. 3. 2,3. 31, ...
STATIC HEAT RECOVERY UNITS. RESIDENTIAL AND LIGHT COMMERCIAL INSTALLATIONS FLEXEO 3V Series Heat recovery unit with high efficiency heat exchanger up to 94%. Its main feature is the possibility to be adpated to all configurations. The construction with independent modules allows high flexibility and several fitting options. It can be mounted on the floor and on the ceiling. On the wall it can be mounted in vertical or horizontal position. Its low profile (300 mm) allows fitting into false ceiling. It can be equipped with a 100% bypass, mantaining its low profile. To ensure good air quality, is equipped with a F5 filter on the inlet side and, to protect the core, a G4 on the extraction side. With its remote control, it is possible to manage the boost function, the bypass and the filters reset alarm. Models FLEXEO BP FL 3V: Cable remote control. FLEXEO BP RD 3V: Radio frequency remote control. Configuration · Counter flow heat exchanger. · EPP body. · Spigots pivoting to 90º. · Fan modules x 2 · 100% bypass , automatic or manual. · Manual boost function. · Inlet filter: M5 (ISO ePM10 50%, at 210m3/h). Option, F7 (ISO ePM1 50%, at 210 m3/h). · Extraction filter G4 (ISO coarse 60%, at 210m3/h). · Wall or ceiling mounting kit · Opening for access to the core by quarter turn fasteners. MOUNTING FLEXIBILITY Specific applications Single dwellings Multi dwelling blocks Heat recovery unit FLEXEO consists of independent modules, which allow multiple configurations. www.solerpalau.com Remote control by cable or wireless: · Bypass · Boost · Absence mode · Filter reset Heat recovery units FLEXEO 203 677 300 150 Ø125 STATIC HEAT RECOVERY UNITS. RESIDENTIAL AND LIGHT COMMERCIAL INSTALLATIONS FLEXEO 3V Series DIMENSIONS (mm) Heat recovery module FLEXEO BP (with bypass) 1372 Fan modules 691 691 Ø124 235 206 253 99 591 356 112.4 204 Heat recovery units FLEXEO www.solerpalau.com STATIC HEAT RECOVERY UNITS. RESIDENTIAL AND LIGHT COMMERCIAL INSTALLATIONS FLEXEO 3V Series TECHNICAL CHARACTERISTICS Model FLEXEO BP FL 3V FLEXEO BP RD 3V Air connections (mm) 125 125 ACOUSTIC DATA Hz 63 125 OUTLET 2,4 12 INLET 10 13,5 RADIATED 4,5 10,4 Voltage (V) 230 230 Maximum airflow at 100Pa (m3/h) 210 210 Absorbed power (W) 100 100 Maximum Efficiency (%) 94 94 Sound pressure, at 3 m distance [210 m3/h @ 100 Pa] 250 500 1000 2000 15,5 32,9 17,6 10,3 17 27,5 22,3 14,5 30 35,6 28,9 28 4000 3 5,9 31,8 8000 2,3 2,5 19 TOTAL dB(A) 31,8 28,4 43 PERFORMANCE CURVES p sf [Pa] 450 V1 400 350 300 V2 250 200 150 100 V3 50 0 0 50 100 150 Speed adjustment zone 200 qv [m3/h] AIRFLOW DIRECTION EFFICIENCY CURVE (%) (m3/h) By pass Rooms www.solerpalau.com Bathroom Exterior Heat recovery units FLEXEO 205 STATIC HEAT RECOVERY UNITS. RESIDENTIAL AND LIGHT COMMERCIAL INSTALLATIONS FLEXEO 3V Series INSTALLATION IN SINGLE DWELLINGS The different parts (fans and exchanger) can be installed in different areas in order to improve performance and reduce noise. LOFT CEILING VOIDS HEATED ROOMS (CORRIDOR, BATHROOM, DINING-ROOM, ...) CEILING VOIDS HEATED ROOMS (CORRIDOR, BATHROOM, DINING-ROOM, ...) NON/HEATED ROOMS (GARAGE, ...) CEILING VOIDS HEATED ROOMS (CORRIDOR, BATHROOM, DINING-ROOM, ...) NON/HEATED ROOMS HEATED ROOMS NON/HEATED ROOMS (LAUNDRY ROOM, ...) (CORRIDOR, BATHROOM, DINING-ROOM, ...) (GARAGE, ...) 206 Heat recovery units FLEXEO www.solerpalau.com STATIC HEAT RECOVERY UNITS. RESIDENTIAL AND LIGHT COMMERCIAL INSTALLATIONS FLEXEO 3V Series FLEXEO SERIES - EXAMPLE OF INSTALLATION IN SINGLE DWELLINGS 9 8 5 6 4 1 7 3 1. Wall mounted air inlet grillle TAP. 2. Supply and extraction valves BDOP. 3. Self-adjusting extraction valve BARJ / BARP 4. Flexible insulated duct GP ISO. 5. Extraction plenum 6. Supply plenum 7. VENT-FLEXEO supply motorised fan and VENT-FLEXEO extraction motorised fan. 8. CADS-FLEXEO: Static heat recovery unit. 9. Roof terminal cowl CT. www.solerpalau.com 2 Heat recovery units FLEXEO 207 STATIC HEAT RECOVERY UNITS. RESIDENTIAL AND LIGHT COMMERCIAL INSTALLATIONS FLEXEO 3V Series MOUNTING ACCESSORIES KIT M5/G4 FLEXEO Replacement kit of M5 and G4 filtres. BARJ BARP Self-adjusting calibrated extraction valves. BDOP Supply and extraction valve. RDR Self-adjusting damper (50-250 Pa) that, fitted inside the duct, maintains constant airflow. GPR-ISO Insulated rigid duct. RD BP Specific low-pressure (20-100 Pa) and self-adjusting damper with sleeve to fit directly into the duct. 80mm diameter. Airflow: 15 or 30 m3/h. GP GPX GP-PRO GP-ISO Insulated PVC ducts. RD BP SM Specific low-pressure (20-100 Pa) and self-adjusting damper without sleeve to fit directly into the sleeve of the BDOP. 80mm diameter. Airflow: 15 or 30 m3/h. TUBPLA V TUBPLA Self-extinguishing rectangular ducts with or without gasket. TAT Air inlet grille under roof.. TAP Wall mounted air inlet grillle. PAF Wall outlet grille. CT Roof cowl. PLENUM UNI IMP 8 Insulated supply plenum of 125/150160mm diameter and up to 8 spigots for dry areas (living room, dining room, bethrooms) of 80mm diameter. ADRF 100/80 Reduction to connect rigid duct to spigots for flexible ducts. PLENUM UNI EXT 6+1 Insulated extraction plenum of 125/ 150160mm diameter, 1 Kitchen spigot of 125mm diameter and up to 6 sanitary spigots of 80mm diameter. 208 Heat recovery units FLEXEO www.solerpalau.comAdobe PDF Library 15.0 Adobe InDesign CC 13.1 (Macintosh)