1. About TS004
Thank you for buying TS004, a handheld thermal scope designed for outdoor enthusiasts. Before using TS004, please read this manual carefully and thoroughly.
2. Cautions
Do not point the thermal scope at the sun or other strong energy sources for a long period of time. Otherwise there might be damage to the detector in the scope. Keep the thermal scope away f rom water to avoid electricity leakage or short circuit. Do not touch the lens with your hands. Do not knock, pry, puncture or scratch the lens. Do not disassemble the thermal scope.
3. What's in the Box?
TS004 USB-A to USB-C Cable Hanging Strap Storage Bag User Manual
EN 5

4. Product Overview

USB-C Port
2

Zoom Button
4

LED Indicator
6

1 Power Button

3 Mode Button

5 Camera Button

7 Diopter Adjustment Knob

Thermal Camera
10

8 Tripod Screw
Hole

9 LED Flashlight
EN 6

11 Eyepiece

4.1 Buttons
The buttons on TS004 are multi-functional. The explanations are given below.
Power Button
When TS004 is powered off, you can press and hold this button to power on TS004. When TS004 is powered on
You can press and hold this button to power off TS004. You can press this button to get TS004 into the standby status. When TS004 is in the standby status, you can press this button to exit this status.
Camera Button
When TS004 is powered on, you can press this button to capture a photo. When TS004 is powered on, you can press and hold this button to record a video.
Zoom Button
When TS004 is powered on, you can press this button to set the zoom level (1X, 2X, and 4X).
Mode Button
When TS004 is powered off, you can press this button to turn on or m0(~ When TS004 is powered on,
You can press this button to set the pseudo-color palette. (Five palettes are available: Bird, White Hot, Black Hot, Red Hot, and Fusion.)
EN 7

You can press and hold this button to activate the system settings. You can see the system settings menu via the eyepiece. For more information about system settings, please follow the on-screen instructions. In this case, the functions of these buttons will change as follows.
Power Button -> Back Button
Mode Button -> OK Button
Zoom Button -> Previous Button
Camera Button -> Next Button

+ Zoom Button

Mode Button

When TS004 is powered on, you can press and hold these two buttons at the same time to measure the distance between the thermal camera and the object.

4.2 LED Indicator

Indicator Status Solid green Solid red
Flashing green Flashing red

Description TS004 is powered on and works well,
or TS004 is fully charged. TS004 is being charged.
TS004 is in the standby status.
TS004 battery is running out (< 10%).

4.3 USB-C Port
ÀDz !À² the supplied USB-A to USB-C cable).
EN 8

4.4 Diopter Adjustment Knob
When you are looking through the eyepiece of TS004, you can turn the knob to adjust the position of the diopter level. This is to optimize the sharpness of the image.
5. Instructions for Use
5.1 Power-on
Press and hold the Power Button for 3 seconds to power on TS004. After TS004 is powered on, check the battery charge. If it is not À²
5.2 Charging
TS004 should be fully charged prior to use. Charge TS004 via the USB-A to USB-C cable. Plug one end into the USB-C port of TS004 and the other end into a USB power source. It takes about four hours to get TS004 fully charged.
5.3 APP
1. Download and install the APP on your phone, and launch it.
Android & iOS 2. Power on TS004 and connect it to your phone via Wi-Fi.
1) Press and hold the Mode Button for 3 seconds. 2) Turn on the Wi-Fi switch on the screen. 3) Connect TS004 to your phone. Note: You can just follow the instructions displayed on the APP interfaces for Wi-Fi connection and further operation.
EN 9

5.4 Pseudo-color Palettes
When you use TS004 to detect objects in the wild, you can choose a suitable pseudo-color palette according to actual situations. Five palettes are available: Bird, White Hot, Black Hot, Red Hot, and Fusion. You can press the Mode Button to toggle between them.

Palette Bird
White Hot

Description
Hot objects appear white. This palette is specially designed for detecting birds or similar objects.
Hot objects appear white. This palette is suitable for daytime use.

Black Hot

Hot objects appear black. This palette is suitable for nighttime use.

Red Hot

The hottest 10% of things in the image appear red, and everything else is gray.

Fusion

Multiple colors will appear in fusion in the image. It is suitable for both
daytime and nighttime use.

5.5 Photos and Videos
In the process of using TS004 for detection, you can take photos and record videos when needed.
To take a photo, press the Camera Button. To record a video, press and hold the Camera Button for 3 seconds.
The photos and videos will be saved on TS004. You can view or transfer them when you connect TS004 to a PC via the USB cable.

5.6 Power-off
           § Button for 3 seconds to power off TS004.
TS004 will automatically shut down when its battery runs out.

EN 10

²

Infrared Camera Resolution Refresh Rate Focal Length Spectral Range Pixel Size NETD FOV IFOV Zoom Level Storage Battery Capacity IP Rating

 50 Hz 13 mm 7.5~14 
< 40 mK  
1X/2X/4X J
5000 mAh IP67

EN 11

7. FAQ
QCan TS004 detect objects underwater, through glass or through a wall?
Ay X         infrared areas, and can only be used to measure surface temperature.
QCan any phone be connected to TS004? ACurrently, TS004 supports phones with Android 7 or later OS
and phones with iOS 12 or later OS.
QX AÀÀ
turn the diopter adjustment knob to optimize the sharpness 
QHow long can I use TS004 to record videos? AYou can keep recording videos before the battery of TS004
runs out. However, TS004 will automatically save the video every 20 minutes.
QHow do I view the captured thermal images on a PC? AConnect TS004 to a PC via the USB cable, and then you can
view the thermal images stored on TS004.
EN 12

8. Warranty
À§(yæmà
TOPDON warrants to its original purchaser that the company's products will be free from defects in material and workmanship for 12 months from the date of purchase (Warranty Period). For the defects reported during the Warranty Period, TOPDON will either repair or replace the defective part or product according to  TOPDON shall not be liable for any incidental or consequential damages arising from the device's use, misuse, or mounting. X    ~   ˤ(y    local laws, the local laws shall prevail. This limited warranty is void under the following conditions:
Misused, disassembled, altered or repaired by unauthorized stores or technicians. Careless handling and operation's violation. Notice: All information in this manual is based on the latest information available at the time of publication and no warranty can be made for its accuracy or completeness. TOPDON reserves the right to make changes at any time without notice.
EN 13

9. FCC Statement
Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 0 mm must be maintained between the user's body and the device, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.
EN 14

FCC ID 2AVYW-TS004


Adobe PDF library 16.07 Adobe Illustrator 27.0 (Windows)