GLOBAL INDUSTRIAL
We can supply that.
High Velocity Dock Fan With Yoke Mount - 115V
Models: 293092, 293093, 293094
User Manuals Available In Multiple Languages
User's manual (English), Manual del usuario (Spanish), Manuel de l'utilisateur (French)
Customer Service (US): 1-800-645-2986
Servicio de atención al Cliente (US): 1-800-645-2986
Service à la clientèle (Canada): 888-645-2986
Important Safety Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Do not use the fan if any part is damaged or missing. To reduce risk of injury, disconnect power supply before servicing or moving.
- DO NOT touch any moving parts.
- DO use a 3-prong outlet.
- DO avoid using extension cords.
- DO NOT kink the cord or allow it to contact oil, grease, chemicals, hot surfaces, or sharp or abrasive objects.
- The fan is intended for general air circulation ONLY. It must NOT be used in potentially dangerous locations such as flammable, explosive, chemical-laden, or wet atmospheres. Do not use fan in or near a window, since rain may create an electrical hazard. DO NOT attach ductwork to the fan.
- Fan motor is equipped with an automatically resetting control circuit that will disconnect power if the motor overheats. Always unplug the fan before removing the guard in case the motor is accidentally turned on.
- Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from high traffic areas and where it will not be tripped over.
A diagram shows the fan assembly with a yoke mount.
Product Specifications
| Model | Fan Diameter | Size WxDxH (inches) | Voltage (V) | Frequency (Hz) | Wattage (W) | AMPS (A) | RPM | Airflow (CFM) | Net Weight (lbs) | Certification |
|---|---|---|---|---|---|---|---|---|---|---|
| 293092 | 14" | 21-3/8 x 15-7/16 x 27-7/16 | 115/208-240 | 60 | 400 | 115V/4.0A; 208-240V/2.0A | 1720 | 6,800 | 32.2 | UL, cUL |
| 293093 | 18" | 25 x 15-3/4 x 27-3/16 | 115/208-240 | 60 | 520 | 115V/4.9A; 208-240V/2.6A | 1720 | 7,700 | 49 | UL, cUL |
| 293094 | 22" | 28-3/4 x 15-3/4 x 31 | 115/208-240 | 60 | 640 | 115/5.9A; 208-240V/3.0A | 1720 | 10,000 | 55.9 | UL, cUL |
Wiring Diagrams
14" Dock Fan - 293092 Wiring Diagram - 115V
Description: This diagram illustrates the wiring for the 14" Dock Fan (Model 293092) at 115V/60Hz. It shows connections between the Capacitor (Red, Orange wires), Auxiliary (Black wire), Main 1 (Yellow wire), Main 2 (White wire), a Thermal Protector (Blue wire), and the Supply Voltage via a Wire Box (Brown wire).
14" Dock Fan - 293092 Wiring Diagram - 208-240V
Description: This diagram illustrates the wiring for the 14" Dock Fan (Model 293092) at 208-240V/60Hz. It shows similar components as the 115V diagram, with the Thermal Protector's blue wire connected to the brown wire (labeled as insulation) from the supply voltage.
18" Dock Fan 293093 & 22" Dock Fan 293094 Wiring Diagram - 115V
Description: This diagram illustrates the wiring for the 18" Dock Fan (Model 293093) and 22" Dock Fan (Model 293094) at 115V/60Hz. The wiring configuration is similar to the 14" fan at 115V.
18" Dock Fan 293093 & 22" Dock Fan 293094 Wiring Diagram - 208-240V
Description: This diagram illustrates the wiring for the 18" Dock Fan (Model 293093) and 22" Dock Fan (Model 293094) at 208-240V/60Hz. The wiring configuration is similar to the 14" fan at 208-240V.
Parts List
Mounted with Pedestal Stroller
Diagram Description: Illustrates the fan assembly (A) mounted on a pedestal stroller. Components shown include the fan (A), tilt adjustable knob (B), handle (C), "U" shaped yoke (D), and the pedestal stroller base (E) with wheels.
Parts for Pedestal Stroller Assembly
| Ref | Qty | Item |
|---|---|---|
| K | 2 | Stroller Pipe |
| L | 1 | T-shaped Pipe |
| M | 2 | Wheel |
| N | 1 | Support Pipe |
| FF | 1 | Screw M16x90mm |
| HH | 4 | Screw M10x16mm |
| II | 4 | Screw M6x20mm |
| JJ | 4 | Spring Washer M6 |
| AA | 1 | Nut M16 |
| BB | 1 | Washer M16 |
Mounted with Dock Truck Mount Bracket
Diagram Description: Illustrates the fan assembly (A) mounted using a dock truck mount bracket (F). Components shown include the fan (A), tilt adjustable knob (B), "U" shaped yoke (D), and the dock truck mount bracket (F).
Parts for Dock Truck Mount Bracket Assembly
| Ref | Qty | Description |
|---|---|---|
| F | 1 | Dock Truck Mount Bracket |
| AA | 1 | Nut M16 |
| BB | 1 | Washer M16 |
| CC | 1 | Screw M16x60mm |
Parts List (Continued)
Mounted with Column Bracket
Diagram Description: Illustrates the fan assembly (A) mounted using a column bracket (G). Components shown include the fan (A), tilt adjustable knob (B), "U" shaped yoke (D), column bracket (G), L-shaped Sheet (H), Long Pipe (I), and Short Pipe (J).
Parts for Column Bracket Assembly
| Ref | Qty | Item |
|---|---|---|
| G | 1 | Column Bracket |
| H | 1 | L-shaped Sheet |
| I | 1 | Long Pipe |
| J | 1 | Short Pipe |
| EE | 2 | Screw M12x90mm |
| FF | 2 | Screw M16x90mm |
| GG | 2 | Nut M12 |
| AA | 2 | Nut M16 |
| BB | 3 | Washer M16 |
| DD | 4 | Expansion Bolt M16 |
Wiring Instructions
- Loosen the screws to remove the inspection window cover in the rear of the motor.
- For 115V power connection: Plug the blue wire to terminal B and the white wire to terminal C.
- For 208-240V power connection: Connect the blue wire to terminal A and the white wire to terminal B.
Installation Instructions
Installing the "U" Shape Yoke
Align the holes of the "U" shaped yoke and the dock fan. Tighten with the rubber pads and tilt adjustable knobs. Let the fan hang from the "U" shaped yoke.
Mounting with Dock Truck Mount Bracket
- Determine the mounting location on the wall and mark the hole locations.
- Use a 0.7 inch (18mm) drill bit and drill holes 2.75 inches (70mm) deep.
- Insert the expansion bolts flush to the wall.
- Attach the dock truck mount bracket and secure with the expansion nut.
- NOTE: The bracket must be fixed securely to the wall before hanging the fan.
- Put the fan onto the "U" shaped yoke, align the holes of the "U" shaped yoke and the bracket, and secure with screw, washer, and nut.
Diagram shows a bracket with a length of 15.94 inches.
Mounting with Column Bracket
- Install the column bracket and tighten the screws and nuts.
- Determine the mounting location on the wall and mark the hole locations.
- Use a 0.7 inch (18mm) drill bit and drill holes 2.75 inches (70mm) deep.
- Insert the expansion bolts flush to the wall.
- Attach the column bracket and secure with the expansion nut.
- NOTE: The mounting bracket must be installed securely to the wall before hanging the fan.
- Align the holes of the "U" shaped yoke and the column bracket, secure with screw, washer, and nut.
Diagram shows bracket dimensions: 2.05 inches and 8.29 inches.
Mounting with Pedestal Stroller
- Install the pedestal stroller as follows, and tighten the screws and nuts.
- NOTE: To reduce the risk of falling, insert the support pipe into the end of the T-shaped pipe first, and then tighten the screw.
- Mount the dock fan to the pedestal stroller, align the holes of the "U" shaped yoke and the pedestal stroller, and secure with screw, washer, and nut.
- Install the handle with screw.
- NOTE: Make sure the motor capacitor is in the up position.
Maintenance
WARNING: Parts replacement and troubleshooting to be performed only by qualified personnel.
DO NOT depend on any switch as the sole means of disconnecting power when installing or servicing the fan. Failure to do so may result in electrical shock. Unplug the fan from the wall outlet before servicing or cleaning.
To clean the fan, use a soft damp cloth. Wipe down with a dry cloth. DO NOT use cleaners that are harmful to paints or plastics. DO NOT use gasoline, benzene, thinner, harsh cleaners, and other chemicals.
The propeller, guard, and motor should be cleaned periodically to prevent overheating, and/or operating in an imbalanced condition.
CAUTION: If cleaning requires the removal of a guard, remove only the front guard and re-install when finished in its originally installed position. Do not repair propeller if it becomes damaged. The propeller is accurately balanced at the factory and should be replaced if damaged. DO NOT bend the propeller.
Motor is permanently lubricated.
Troubleshooting
If your fan fails to operate, please follow these instructions:
- Make sure the fan is plugged in and the electrical outlet is working properly.
- Check for any obstruction. If you find an obstruction, turn the fan "OFF". Unplug the fan and carefully remove the obstruction.
Plug the fan in and turn it on again. It should resume normal operation.
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR FAN, PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE FAN YOURSELF. DOING SO COULD CAUSE DAMAGE TO THE FAN AND/OR CAUSE PERSONAL INJURY. Always consult Global Industrial before further use.