User Manual for Shenzhen models including: RB081, 2BME6-RB081, 2BME6RB081, RB-081 LED Light Therapy Mask, RB-081, LED Light Therapy Mask, Light Therapy Mask, Therapy Mask, Mask

liyuan.liu@sungoglobal.com

User Manual

Shenzhen Rainbow Technology Co.,Ltd RB081 2BME6-RB081 2BME6RB081 rb081


File Info : application/pdf, 21 Pages, 1.08MB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7931605
User Manual LED Light Therapy Mask
Please read this manual carefully before using the product Shenzhen Rainbow Technology Co.,Ltd
Release date: 2024.06.07Version: A0
I

Table of contents
1. Product overview ........................................................................................................................... 1 1.1. Basic information ................................................................................................................ 1 1.2. Indications for use ............................................................................................................... 1 1.3. Package content ................................................................................................................... 1 1.4. Product main structure......................................................................................................... 1
2. Product Specifications.................................................................................................................... 2 3. Contraindications ........................................................................................................................... 3 4. Warnings and Precautions .............................................................................................................. 4
4.1. Warnings .............................................................................................................................. 4 4.2. Precautions .......................................................................................................................... 5 5. Getting started ................................................................................................................................ 5 5.1. Device Set-up ...................................................................................................................... 5 5.2. Light sensitivity test ............................................................................................................ 6 5.3. Charging the battery ............................................................................................................ 6 6. How to use it .................................................................................................................................. 7 6.1. Preparation........................................................................................................................... 7 6.2. Tips for adjusting the headband:.......................................................................................... 7 6.3. Operation instruction ........................................................................................................... 8 7. Care and maintenance .................................................................................................................. 10 8. Disposal........................................................................................................................................ 10 9. Symbols meaning ......................................................................................................................... 11 10. Common malfunctions and solutions......................................................................................... 11 11. EMC Statement .......................................................................................................................... 12 12. Warranty and special offers information .................................................................................... 12 13. Contact information ................................................................................................................... 14 Annex I. Guidance and Manufacture's Declaration ......................................................................... 15
II

1. Product overview 1.1. Basic information Product Name: LED Light Therapy Mask Model: RB-081 Manufacturer: Shenzhen Rainbow Technology Co.,Ltd 1.2. Indications for use  Red+Infrared light: Treatment of full-face wrinkles.  Red light: Treatment of full-face wrinkles.  Infrared light: Provide topical heating for the purpose of elevating tissue temperature; arthritis
and muscle spasm;relieving stiffness; promoting the relaxation of muscle tissue; and to temporarily increase local blood circulation.  Blue light: Treatment of mild to moderate inflammatory acne.  Red+Blue light: Treatment of mild to moderate inflammatory acne. The device is intended to use LED light for the treatment of wrinkles and mild to moderate acne for adults in home healthcare environment.

1.3. Package content

Upon opening the product package, you will find the following contents inside:

Items

Diagrammatic sketch

Items

Diagrammatic sketch

Main unit*1

User manual*1

Remote control*1

Storage bag*1

Type-C charging cable*1

Package box*1

1.4. Product main structure LED Light Therapy Mask is mainly composed ofmain unit, remote control, Type-C charging cable, etc. - Main Unit

1

- Remote control (RF remote control: the controller will emit RF signal, and the main unit will receive it.)

1.5. Customer Conditions
----at least can read and understand the user manual and have self-control and self-consciousness. ----at least has a minimum of 8 years of education.

2. Product Specifications

Product Name LED Light Therapy Mask

Model Name

RB-081

Power remote control

Input

5 V 1 A

Battery

LED Mask: 3.7V/2000mAh Lithium polymer Battery

specifications Remote control: CR2032, one 3V lithium battery

Max running time 90-120 minutes (depending on mode)

Charging time 4 hours

Protection against Class II

electric shock

Type BF Applied Part (light emission part)

Dimensions

LED Mask

About 19.5 X 22.3 X 9.3 (cm)

Remote control About 4.5 X 13.3 X 3.2 (cm)

Weight

LED Mask

About 391 g

remote control About 50 g

Light

2

Light source Risk group
Wavelength
Energy level
Operation condition Temperature Humidity
Atmosphere pressure Storage condition
Temperature Humidity
Atmosphere pressure Service life

Light Emitting Diodes Exempt group Red: 630nm Blue: 460nm Infrared: 850nm Red+IR: 45.5mW/cm2 Red light: 53.2mW/cm2 Infrared light: 47.3mW/cm2 Blue light: 58.7mW/cm2 Red+Blue light: 33.6mW/cm2
+5 to +30 15% to 90%RH 700hPa to 1060hPa
-20 to + 60 10% to 95%RH 700hPa to 1060hPa 3 years

3. Contraindications  DO NOT use if you have a history of light-triggered seizures. It isrecommended that you test a
small less sensitive patch of skin (see section light sensitivity test).  DO NOT use LED Light Therapy Mask to treat any other conditions apart from those listed in
the indications for use. The LED Light Therapy Mask has not been tested for any other conditions than those listed, andthe risk is unknown.  DO NOT use LED Light Therapy Mask if you are pregnant, planning onbecoming pregnant, or breastfeeding.The LED Light Therapy Mask hasNOT been tested on pregnant or breastfeeding women and therefore the risk to the fetus, neonate, or pregnant women is unknown.  DO NOTuse LED Light Therapy Mask if you suffer from Lupus erythematosus, photosensitive eczema, or Albinism. If you use the LED Light Therapy Mask to treat Lupus erythematosus, photosensitive eczema, orAlbinism you may cause a severe skin reaction.  DO NOT use LED Light Therapy Mask if you suffer from any photosensitive disorder (sensitization to light). If you use the LED Light Therapy Mask and you suffer from a photosensitive disorder you may cause a severe skin reaction.  DO NOT use LED Light Therapy Mask if you are taking any medication that can cause photosensitivity. If you use the LED Light Therapy Mask and you are taking any medication that can cause photosensitivity you may cause a severe skin reaction. photosensitivity is a common side effect of various medications. These can include certain antibiotics, chemotherapy drugs, and diuretics. If you are unsure about any medication you may be taking consult your healthcare provider. Other substances not listed above can also cause photosensitivity.
3

 Common examples of these substances are: St John's Wort, Coal tar, Deodorants, antibacterial soaps, artificial sweeteners, naphthalene (mothballs), petroleum products, brightening agents found in laundry detergent, and cadmium sulfide (a chemical injected into the skin during tattooing).
4. Warnings and Precautions
4.1. Warnings  Before using the LED Light Therapy Mask you must carry out a sensitization test (see section
light sensitivity test). DO NOT use the LED Light Therapy Mask if you are sensitive to LED Light Therapy Mask.This unit is intended to be used in the home healthcare environment, the patient can be an intended operator  DO NOT use the LED Light Therapy Mask in any way that is not exactly as specified in these instructions for use. Use of the LED Light Therapy Mask LED other than exactly as specified in these instructions for use has not been tested and the risk is unknown.This equipment is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the equipment to avoid the risk of fire or burns  TURN OFF and REMOVE the LED Light Therapy Mask immediately if it feels hot or your skin feels uncomfortably warm.Due to the long cable of the charging cable, strangulation may occur, so keep the product out of the reach of children  DO NOT use the LED Light Therapy Mask LED without first removing makeup BEFORE treatment. Some ingredients in these products may cause light sensitization or may reduce the effect of the treatment. If you use the LED Light Therapy Mask without removing these products, you may cause a skin reaction, or you may reduce the effect of the treatment.This equipment is not intended for use by children. Children should be supervised to ensure that they do not play with the equipment to avoid the risk of fire and burns  NEVER use LED Light Therapy Mask LED near water or where water can be spilled onto the equipment. DO NOT use the LED Light Therapy Mask if you think it has come into contact with water.Do not subject the equipment to heavy shocks to avoid risk of damage to the lamp  Keep the LED Light Therapy Mask away from HOT surfaces.If needed, contact the manufacturer for assistance in setting up, using, or maintaining the ME EQUIPMENT or reporting unexpected operation or events  DO NOT attempt to modify the LED Light Therapy Mask LED in any way. Modifying the LED Light Therapy Mask will void your warranty. Modifying the LED Light Therapy Mask LED could cause an electric shock when the system is used again. The system contains no serviceable parts.Use of accessories other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity  DO NOT use the LED Light Therapy Mask LED if the mask, remote control, or cord is damaged in any way.Do not leave the equipment unattended when it is switched on to avoid the risk of fire or burns  When removing form minimum / maximun storage temperature, it is recommended to recover for 2 hours before use
4

 Do not look directly or shine light in the eyes while in operation 4.2. Precautions 4.2.1. General safety TheLED Light Therapy Mask is an electrical device, which under certain circumstances could present an electrical shock hazard to the user. please read the accompanying user manualthoroughly and follow directions stated inthe manual to assure maximum safety during operaTtihoen. LED Light Therapy Mask strap contains a mixture of polyester, nylon and lycra. If you
are allergic to any of these materials, you may not be able to use the head strap provided.  The LED Light Therapy Mask cannot be used in charging mode.  Before each use, with the device switched off, clean the face mask.  DO NOT use any other cleansing products other than those stated in the cleaning instructions.
The use of other cleansing products may damage the LED Light Therapy Mask.  Store the LED Light Therapy Mask at room temperature in dry conditions, away from direct
sunlight.
4.2.2. Electrical safety  DO NOT store the device in temperatures exceeding 140or 60 . Raising the internal
temperature may cause a malfunction or fire.  If there is smoke or a strange smell, stop using it, turn off the power, and remove the charging
adapter.  DO NOT damage, process, bend, twist or heat the USB cable. Damage to the cord may cause
fire or electric shock.  DO NOT place or operate the device near water or liquids. It may cause fire or electric shock.  Since this product has a built-in battery in the system, fully charge the battery when using it
for the first time after purchase.  Since batteries are consumables, the usable time of batteries gradually decreases when used
for an extended period.  The built-in battery cannot be removed or replaced at the customer's discretion, and there is a
risk of explosion if the battery is not properly placed.  DO NOT dispose of the battery randomly, follow your local disposal procedure when
disposing of it.  Recommended using the DC 5V 1A charging adapter. Please avoid using chargers of unknown
origin or poor quality to ensure device safety, with a maximum output power not exceeding 30W.Please use an adapter compliant with IEC 60601-1:2005 + AMD2:2020 for charging, input: 100-240VAC, output: DC 5V, 1.0A.
5. Getting started
5.1. Device Set-up Getting started with LED Light Therapy Mask is easy. 1) Unpack the device and all the accessories. 2) Remove the remote control battery protection pad to replace a new
battery(CR2032) if the battery is dead. 3) Your device has an internal rechargeable battery. You will need to
fullycharge your device approximately 4 hours before the first use.
5

See section 5.3 - Charging the Battery for details.
5.2. Light sensitivity test Follow these instructions to see if you are sensitive to light: 1) Initiate the device by briefly pressing the LED mask power button, then switch color modes
using the remote control "color modes selection button". 2) Place the device on a section of the forearm, maintaining contact for the entire three-minute
treatment cycle. 3) Press the color modes selection button again to choose a different mode for another
three-minute treatment on the same forearm area. 4) Wait 24 hours. You should NOT experience any adverse reaction during the next 24 hours. 5) An adverse reaction is a pain or discomfort in the treatment areas or any pro- longed skin
redness.
5.3. Charging the battery Before use, be sure to charge the LED mask battery as follows. (Charging time may vary depending on the battery charge status. It takes up to 4hours.)
1) Connect the Type-Cport of remote control by the supplied charging cable. 2) Connect the opposite USB port with the 5V 1A charging adapter to charge. 3) If the Indicator on the remote control lights up in green, it is fully charged. Please unplug the
charging cable and use the device. Note please: The colors of the power button changes depending on the charging status of the LED mask. - Redflashing: Indicates low battery / charging required. (please charge the device promptly.) - Green flashing: Standby. (Battery power is sufficient to use LED mask.) - Green light: Battery is fully charged. Lithium Battery Maintenance Tips: - Avoid fully draining the battery before recharging. - Avoid overcharging the battery and try to limit the charging time to a maximum of 8 hours. - If the device is not in use for an extended period, it is recommended to charge the battery at least once every three months.
6

6. How to use it 6.1. Preparation
1) Wash your face clean. (If you make up, please cleanse by cleansing foam.) 2) It can be used day or night. You can fit it into your current skincare routine after cleaning
and/or exfoliating your skin. 3) Be sure to fully charge the battery before use. (when pressing button of remote control, if it
flashes in green, it indicates the device is in usable and chargeable state.)
1) Remove the button battery plastic insulation pad of the remote control. 2) Long press the button of the LED mask for 5 seconds to turn on the power. (Available when
blinking green.) 3) After adjusting the hair band moderately, wear it so that the inner side of the LED mask is on
the face. 6.2. Tips for adjusting the headband: (1) When sitting or standing, the correct state should be minimal pressure on the eye socket,
allowing the silicone eye pad to fit the eye socket, with the headband fixed the product. (2) If you feel the silicone eye pad is exerting too much pressure on the eye socket, loosen the
headband on both sides. (3) If the silicone eye pad does not fit the eye area and light can enter through the gap between the
eye pad and eye socket, tighten the headband on both sides. (4) If you feel the mask is sliding down and cannot maintain the correct position on your face,
.
tighten the headband. (5) Place the chin rest on the chin (under the lip). There are 4 gears for the chin rest (Up, Upper
middle, Lower middle, Down). Push the chin rest to move it one step upwards or downwards for a better wearing result.
7

(6) Select the desired mode using the buttons on the remote control. (7) If you feel uncomfortable while wearing the device, you can try to adjust the strap or pick it
off until you feel better. (8) The product will be turned off automatically when the set mode and the corresponding time
finished.
- Remove: If user feels uncomfortable due to the chin rest, adjust it to "Down" gear and push it down to remove it. (Please store your chin rest after disassembly.) - Install: To reinstall the chin rest, align it with the bottom of the slide and push it up to secure it in place. (As shown in the picture above) Cautions for Use Move the remote control within 30 cm of the LED mask. Please do not act violently when wearing the product. When wearing the product, relax in a comfortableposition on the couch or bed.
6.3. Operation instruction 6.3.1. Remote control matching As it is aRF remote control(the controller will emit RF signal, and the main unit will receive it), so whenusing the LED mask for the first time, user should match the LED mask and remote control. Long press the power button of LED mask for 5 seconds to enter the matching state: 1) In non-power saving state: short press the button of remote control within 10 seconds to match
the remote control with LED Mask. 2) In power saving state: short press the button of remote control to activate it, then short press
the button again to match the remote control with LED Mask. Note:  If the remote control and LED mask can not be matched within 10 seconds, the LED mask
would quit the matching state.  If there is no operation for 30 seconds, the remote control would enter power saving state,
and the screen would go out. User should short press the button to activate the remote control.  The LED mask and remote control would be matched before delivery. If they are not matched,
users can match them according to the above instructions.
8

6.3.2. Mode switching

User can select different modes according to the following instructions:

LED Mode

Selection method

Indicator and beep sound

Standby

Short press the button of LED mask, it would enter the standby state. - LED mask would turn off automatically without operation for 5 minutes. - Short press the button of LED mask again to turn off the mask.

LED mask indicator: - Redflashing: Indicates low battery / charging required. - Green flashing: Standby. (Battery power is sufficient to use LED mask.) - Green light: Battery is fully charged. Whenentering standby mode, the LED mask indicator would light up with a beep sound. When powering off, the LED mask indicator would light out with two beep sound.

Short press the button of remote

Red+Infrared

control to enter the red+infrared light mode, and the LED mask

LED mask: beep sound

would turn off automatically Remote control: the screen would display R+N.

after 10 minutes.

Short press the button of remote

RED

control to enter the red light mode, and the LED mask

LED mask: beep sound

would turn off automatically Remote control: the screen would display RED.

after 10 minutes.

Short press the button of remote

Infrared

control to enter the infrared light mode, and the LED mask

LED mask: beep sound

would turn off automatically Remote control: the screen would display NIR.

after 10 minutes.

Short press the button of remote

Blue

control to enter the blue light mode, and the LED mask

LED mask: beep sound

would turn off automatically Remote control: the screen would display BLU.

after 10 minutes.

Short press the button of remote

control to enter the red+blue LED mask: beep sound

RED+Blue light mode, and the LED mask Remote control: the screen would display would turn off automatically PURP.

after 10 minutes.

Short press the button of remote

Standby

control, the LED mask would enter standby mode and the

LED mask: two beep sound

Remote control: the screen would light out.

remote control would enter

power saving state after 30

9

seconds. Note: 1) In any treatment mode, the LED mask would enter standby mode by pressing the button of LED
mask. 2) In standby state, user can select treatment mode by short pressing the button of remote control,
these modes would be switched in order [Standby - Red+Infrared - Red - Infrared - Blue Red+Blue - Standby]. 3) In standby state, the LED mask will be turned off automatically without operation for 5 minutes. 4) In standby state, the LED mask will be turned off by pressing the button of LED mask. 5) The LED mask will be turned off automatically at the end of the treatment duration.

The parameters of different modes are as follows:

LED Mode

Duration Quantity of LED's
(minutes)

60 bulbs ofRed

RED+Infrared

10

60bulbs of NIR

RED

60bulbs of Red 10

Wavelength (nm)
630, 850
630

Power of light (mW/cm2)
45.5
53.2

Infrared

60bulbs of NIR 10

850

47.3

Blue Light RED+Blue

60 bulbs ofBlue 10
60 bulbs ofRed 10
60 bulbs ofBlue

460

58.7

630, 460

33.6

7. Care and maintenance 1) Store the LED Light Therapy Mask at room temperature in dry conditions. Use the carry bag
provided. 2) Avoid storing the LED Light Therapy Mask in dusty conditions, in direct sunlight or in damp
and humid conditions. 3) The LED Light Therapy Mask contains no serviceable parts. 4) Before each use, with the device switched off, clean the face mask following the cleaning
instructions below. Cleaning the LED Light Therapy Mask 1) DO NOT use any other cleansing products as these may damage the device. 2) Clean the device surface with a water-based wipe or damp clean cloth. Stubborn stains can be
removed by wiping gently with 70% alcohol, then use a dry and clean cloth to wipe the device.

8. Disposal DO NOT dispose any part of the LED Light Therapy Mask at a domestic waste facility. The LED Light Therapy Mask and remote control contains a Lithium-ion polymer battery. For the protection of the environment, please package and return this unit to the manufacturer or their representative at the end of its working life or safely dispose of the device following your local guidelines.
10

9. Symbols meaning Symbol

Meaning

Symbol

Meaning

Batch Code
Refer to instruction manual/ booklet

Serial number Type BF Applied Part

Class II equipment

Caution

Manufacturer General warning sign

Manufacture Date
WEEE (Waste Electrical and Electronic Equipment). The waste products should be handled legally.

IP22

IP Classification

Keep dry

Keep away from sunlight

Fragile, handle with care

10. Common malfunctions and solutions 1) The remote control screen does not light up after pressing a button, and the mask cannot be
controlled. Solution: Check whether the battery isolation tab in the battery compartment of the remote control has been removed. If it has been removed and the remote control still does not work, please check whether the buttonbattery is exhausted. If it is indeed a battery issue, you can contact us for a replacement of the button battery.
2) Turn on the mask, the screen lights up after pressing the remote control button, but the mask cannot be controlled.
Solution: Please repair the remote control and the mask. Pairing method: a. Long-press the power button on your device for five seconds, the alternately flashing red and
green lights indicate that itisin pairing mode. b. Simply press the button on the remote remote control to complete the pairing process.
11

3) The remote control cannot be charged. Solution: a. Replace the charging cable. If it is indeed a charging cable issue, you can contact us for a
replacement of the charging cable.If the problem still cannot be solved, please contact us to replace the device. b. Check whether the charging adapter to which you connect the unit is live or whether the voltage indicated on the unit corresponds to the local mains voltage.
11. EMC Statement 1) LED Light Therapy Mask needs special precautions regarding EMC and need to be installed and put into service according to the EMC information provided in the accompanying document; 2) Portable and mobile RF communications equipment can affect LED Light Therapy Mask. Warning: 1) Don't near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high. 2) Use of accessories, transducers and cables other than those specified or provided by the manufacturer of LED Light Therapy Mask could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. 3) Use of LED Light Therapy Mask adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. 4) Do not expose the device to the EM emitters, including but not limited to: radio-frequency identification(RFID) readers, security systems(e.g..metal detectors or electronic article surveillance(EAS)), wireless power transfer(WPT), and 5G cellular signals. 5) Portable RF communicationsequipment (including peripherals such as antenna cables and external antennas) shouldbe used no closer than 30 cm (12 inches) to any part of the [ME EQUIPMENT Or ME SYSTEM], including cables specified bythe manufacturer. Otherwise, degradation of theperformance of this equipment could result. 6) When functions or performance are lost due to EM disturbances, user should shut down the device and then use it again after being away from the interference source.
12. Warranty and special offers information We will make availableon request circuit diagrams, component part lists, descriptions, calibration instructions, orother information that will assist SERVICE PERSONNEL to repair those parts of ME EQUIPMENTthat are repairable by SERVICE PERSONNEL. 1) Standard warranty and return policy Every original LED Light Therapy Mask comes with a 1-year limited warranty and a 56-day no-questions-asked return service. If you have any product inquiries or need assistance, please contact us at:
customerservice@beauty.com +86 13253413226 www.beauty.com 2) Value-added extended warranty service
12

To provide you with a more comprehensive after-sales experience, we offer a value-added service that can be purchased on our official website:an additional 1-year of warranty and a 90-day no-questions-asked return service. The price for this value-added service is $30 or the equivalent in local currency. 3) Free activation of additional benefits Now, you can immediately get the above-mentioned value-added services for free! Simply scan the QR code via Whats App or contact us through email and our official website to activate. once successfully activated, you will receive a total of 2-year of warranty service, 146 days of no-questions- asked return service, and the opportunity to enjoy one-on-one skincare guidance from our expert professionals, as well as a chance to try out LED Light Therapy Mask's new products for free. 13. Troubleshooting
We will make available on request circuit diagrams, component part lists, descriptions, calibration instructions, or other information that will assist SERVICE PERSONNEL to repair those parts of ME EQUIPMENT that are repairable by SERVICE PERSONNEL.

Name: Address:

Warranty Card Warranty period from the date of purchase

13

Email: Purchase date: Order number: (*means required,and the other information means optional provided) Note please! Respects every customers' privacy. We will never share this information to the 3rd part persons orcompanies and we will never send any advertisements without your permission. 14. Contact information Shenzhen Rainbow Technology Co.,Ltd Address: 5th floor, Building C, Fenda Technology Innovation Park, Xixiang, Baoan District Shenzhen Guangdong, CN 518000 Tel: +86-135-9032-9742 Fax: +86-755-23114522 E-mail: layla@rainbowdo.com
14

Annex I. Guidance and Manufacture's Declaration

- The LED Light Therapy Maskis applicable for use in all establishments (included home

healthcare environment) expect for near active HF surgical equipment and the RF shielded

room of an ME system for magnetic resonance imaging, where the intensity of EM

disturbances is high.

- No Essential Performance as defined by manufacturer.

- The Basic Safety of the LED Light Therapy Mask is as following: Deviation from normal

operation that poses unacceptable risks to the patient or operator.

-

Warnings: The use ofLED Light Therapy Mask adjacent to or stacked with other equipment

should be avoided because it could result in improper operation. If such use is necessary, this

equipment and the other equipment should be observed to verify that they are operating

normally.

- The use of accessories, transducers and cables other than those specified, with the exception

of the accessories, transducers and cables provided by the manufacturer of the LED Light

Therapy Maskas replacement parts for internal components, may affect compliance of the ME

equipment or ME system with the requirements of Clause 7 (EMISSIONS) and Clause 8

(IMMUNITY).

-

Warnings: Portable RF communications equipment (including peripherals such as antenna

cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of

the LED Light Therapy Mask, including cables specified by the manufacturer. Otherwise,

degradation of the performance of this equipment could result.

- Guidance and manufacturer's declaration

The following cables must be used to meet electromagnetic emissions and immunity

requirements:

Table 1-1 Sample cable

No. Name

Cable length (m) Shield (Yes or No)

Remarks

1. Power supply cable

1.5±0.3

No

/

Table 1-2 Electromagnetic emission TABLE 1-2-1 Guidance and manufacturer's declaration -electromagnetic emissions
Guidance and manufacturer's declaration - electromagnetic emissions

Emissions test

Compliance

RF emissions

Group 1

CISPR 11

RF emissions

Class [B]

CISPR 11

Harmonic emissions

Class A

IEC 61000-3-2

Voltage fluctuations/ flicker

Comply

15

emissions IEC 61000-3-3

TABLE 1-2-2Guidance and manufacturer's declaration - electromagnetic immunity Guidance and manufacturer's declaration - electromagnetic Immunity

Immunity Test

IEC 60601-1-2

Compliance level

Test level

Electrostatic discharge ±2kV, ±4kV, ±8kV and ±15kV air

±2kV, ±4kV, ±8kV and ±15kV air

(ESD)

±8kV contact

±8kV contact

IEC 61000-4-2

Electrical

fast ±2kV for a.c. power lines

±2kV for a.c. power lines

transient/burst

IEC 61000-4-4

Surge

±0.5kV and ±1kV for a.c. power ±0.5kV and ±1kV for a.c. power

IEC 61000-4-5

line(s) to lines

line(s) to lines

Voltage dips, short 0% UT; 0, 5 cycleg) At 0°, 45°, 90°, 0% UT; 0, 5 cycleg) At 0°, 45°, 90°,

interruptions

and 135°, 180°, 225°,270°and 315°

135°, 180°, 225°,270°and 315°

voltage variations on 0% UT; 1 cycle and70% UT; 25/30 0% UT; 1 cycle and70% UT; 25/30

power supply input cycles

cycles

lines

Single phase: at 0°

Single phase: at 0°

IEC 61000-4-11

0% UT; 250/300cycle

0% UT; 250/300cycle

Power

frequency 30A/m

30A/m

magnetic field

IEC 61000-4-8

Conduced RF

3Vrms

3Vrms

IEC61000-4-6

0,15 MHz ­ 80 MHz

0,15 MHz ­ 80 MHz

6Vrms in the ISM frequency band

6Vrms in the ISM frequency band

16

Radiated RF

10 V/m

10 V/m

IEC61000-4-3

80 MHz ­ 2,7 GHz

80 MHz ­ 2,7 GHz

NOTE UT is the a.c. mains voltage prior to application of the test level.

TABLE 1-2-3 Guidance and manufacturer's declaration - electromagnetic immunity

Guidance and manufacturer's declaration - electromagnetic Immunity

Radiated RF

Test Band Service Modulati Modulati Distanc IMMUNIT

IEC61000-4-3 Frequen (MHz

on

on (W)

e

Y

(Test

cy

)

(m)

TEST

specifications (MHz)

LEVEL

for

(V/m)

ENCLOSURE

385

380 TETRA Pulse

1,8

0.3

27

PORT

­390 400 modulatio

IMMUNITY to

n

RF wireless

18 Hz

communications 450

430 GMRS

FM

2

0.3

28

equipment)

­470 460,

± 5 kHz

FRS 460 deviation

1 kHz sine

710 704 ­ LTE

Pulse

0,2

0.3

9

745

787 Band 13, modulatio

780

17

n

217 Hz

810 800 ­ GSM

Pulse

2

0.3

28

870

960 800/900, modulatio

930

TETRA

n

800,

18 Hz

iDEN

820,

CDMA

850,

LTE

Band 5

1720 1 700 GSM

Pulse

2

0.3

28

1845

­

1800; modulatio

1970

1 990 CDMA 1900;

n 217 Hz

17

GSM

1900;

DECT;

LTE

Band 1,

3,

4, 25;

UMTS

2450 2 400 Bluetoot Pulse

2

0.3

28

­

h,

modulatio

2 570 WLAN,

n

802.11 217 Hz

b/g/n,

RFID

2450,

LTE

Band 7

5240 5 100 WLAN Pulse

0,2

0.3

9

5500

­ 802.11 modulatio

5785 5 800 a/n

n 217 Hz

18

FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used i n portable exposure condition without restriction.
19



References

Microsoft Office Word 2007 Microsoft Office Word 2007