Owner's Manual for MEAN WELL models including: DRS-480-24, DRS-480-36, DRS-480-48, DRS-480 Series 480W All In One Intelligent Security Power, DRS-480 Series, 480W All In One Intelligent Security Power, All In One Intelligent Security Power, Intelligent Security Power, Security Power, Power
DRS-480-48 MEAN WELL - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 14 Pages, 1.50MB
DocumentDocument480W All-In-One Intelligent Security Power DRS-480 series User's Manual UL62368-1 BS EN/EN62368-1 AS/NZS 62368.1 TPTC004 (Pending) IEC62368-1 · https://www.meanwell.com/serviceGTIN.aspx https://www.meanwell.com/webapp/product/search.aspx?prod=SBP-001 Downloaded from Arrow.com. File Name:DRS-480-SPEC 2023-11-16 480W All-In-One Intelligent Security Power DRS-480 series SPECIFICATION MODEL DRS-480-24 DRS-480-36 DRS-480-48 OUTPUT VOLTAGE Note.2 24V LOAD CURRENT RANGE 0 ~ 20A 36V 0 ~ 13.3A 48V 0 ~ 10A OUTPUT BATTERY CURRENT (CC)(max.) 15.4A 10.2A 7.7A RECOMMENDED BATTERY CAPACITY(AMP HOURS)Note.3 20 ~ 200AH 13 ~ 133AH 10 ~ 100AH TOTAL OUTPUT POWER Note.4 Combined power on all Channels must not exceed 480W, load has priority. 550W peak capability within 5s. RIPPLE & NOISE (max.) Note.5 240mVp-p 360mVp-p 480mVp-p VOLTAGE TOLERANCE Note.6 ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% LOAD REGULATION ±0.5% ±0.5% ±0.5% SETUP RISETIME Note.7 2400ms, 1000ms/230VAC 2400ms, 1000ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC 10ms/115VAC at full load VOLTAGE RANGE 90 ~ 305VAC 127 ~ 431VDC FREQUENCY RANGE 47 ~ 63Hz INPUT POWER FACTOR (Typ.) EFFICIENCY (Typ.) PF>0.95/230VAC 92.5% PF>0.98/115VAC at full load 93.5% 93.5% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 5.4A/115VAC 2.7A/230VAC COLD START 30A/115VAC 60A/230VAC SHORT CIRCUIT OVERLOAD Protection type: Constant current limiting, power will shutdown after 5 sec, re-power on to recover. 105 ~ 135% rated output power Protection type: Constant current limiting, shutdown output voltage after 5 sec. PROTECTION OVER TEMPERATURE Automatically drop load with temperature only for bat. load. Protection type : Shut down o/p voltage, recover automatically after temperature goes down. OVER VOLTAGE BATTERY CUT OFF Load main output : 32.4 ~ 37.3V Load main output : 48.6 ~ 55.9V Protection type : Shut down o/p voltage, re-power on to recover 20.9±0.5V 31.3±0.7V Load main output : 64.8 ~ 74.5V 41.8±1V REVERSE POLARITY By internal MOSFET, no damage, recovers automatically after fault condition is removed. FORM-C RELAY AC FAIL CHARGER FAIL DC OK Signals AC failure and activates when input voltage drops below : 79~89VAC of 120AC, 132~187VAC of 220VAC. Relay contact output, ON : AC OK ; OFF : AC Fail ; max. rating : 30Vdc/1A Relay contact output, ON : Charger OK ; OFF : Charger Fail ; max. rating : 30Vdc/1A Signals normal DC output and activates when output voltage > 90% rated value. Relay contact output, ON : DC OK ; OFF : DC Fail ; max. rating : 30Vdc/1A FUNCTION BATTERY LOW/ ABNORMAL/ DISCONNECTED BATTERY START Relay contact output, ON : Battery OK ; OFF : Battery Low ; max. rating : 30Vdc/1A Battery low voltage : < 22V±0.3V Battery low voltage : < 33V±0.4V Restart system directly from battery and does not require AC power Battery low voltage : < 44V±0.5V DC-UPS UPS switch to battery power within 10ms of AC failure ADJUSTABLE CHARGING CURRENT 20% ~ 100% charging current adjustable by VR BATTERY TEMPERATURE COMPENSATION The system can change the battery charging voltage by detecting the temperature (Please refer to page 9~10 for more details). WORKING TEMP. -30 ~ +70(Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) on Load output VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.8 2000 meters / OVC OVER VOLTAGE CATEGORY ; According to Dekra BS EN/EN62368-1; altitude up to 2000 meters SAFETY STANDARDS UL62368-1, Dekra BS EN/EN62368-1, RCM AS/NZS 62368.1 approved; EAC TP TC 004 pending WITHSTAND VOLTAGE I/P-O/P: 4KVAC I/P-FG: 2KVAC O/P-FG: 1.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25/ 70%RH Parameter Standard Test Level / Note Conducted BS EN/EN55032 (CISPR32) Class B EMC EMISSION Radiated BS EN/EN55032 (CISPR32) Class B Harmonic Current BS EN/EN61000-3-2 ----- SAFETY & EMC (Note.10) Voltage Flicker BS EN/EN61000-3-2 ----- BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2) Parameter Standard Test Level / Note ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact; criteria A Radiated BS EN/EN61000-4-3 Level 3, 10V/m ; criteria A EMC IMMUNITY EFT / Burst Surge BS EN/EN61000-4-4 BS EN/EN61000-4-5 Level 3, 2KV ; criteria A Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-Chassis ;criteria A Conducted BS EN/EN61000-4-6 Level 3, 10V ; criteria A Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m ; criteria A FIRE DETECTION AND FIRE ALARM SYSTEM Compliance to BS EN/EN54-4 MTBF 556.6K hrs min. Telcordia SR-332 (Bellcore); 74.5K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 110*125.2*150.7mm (W*H*D) PACKING 1.65Kg; 6pcs/ 11Kg / 1.42CUFT NOTE https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:DRS-480-SPEC 2023-11-16 480W All-In-One Intelligent Security Power DRS-480 series Block Diagram EMI I/P FILTER Derating Curve RECTIFIER & PFC POWER SWITCHING PFC CONTROL PWM CONTROL AUX POWER O.T.P. & DERATING CONTROL RECTIFIERS & FILTER O.V.P. CURRENT DETECTION MCU O.T.P. & DERATING CONTROL MODBUS CANBUS OPTIONAL PFC fosc : 80KHz PWM fosc : 65KHz +V -V CHARGING & UPS FUNCTION REVERSE DETECTION BAT. + BAT. BAT. start Force start RELAY CONTROL AC Fail Charger Fail DC OK Battery low / Abnormal / Disconnected LOAD (%) 100 80 60 40 20 -30 -20 0 15 30 40 50 60 70 (VERTICAL) AMBIENT TEMPERATURE () Static Characteristics 100 90 80 70 60 50 40 90 100 125 135 145 155 165 175 180 200 230 277 305 INPUT VOLTAGE (V) 60Hz File Name:DRS-480-SPEC 2023-11-16 LOAD (%) Downloaded from Arrow.com. 480W All-In-One Intelligent Security Power DRS-480 series Function manual 1.Alarm signals (1) Alarm Signal is sent out through " AC fail " & " Battery low " & " Charger fail "pins via relay contact. (2) An external voltage source is required for this function. The maximum applied voltage is 30Vdc and the maximum sink current is 1A. Please refer to Fig 1.2. (3) Table1.1 explains the alarm function built in the power supply INPUT AC only AC + BAT. BAT. only Low BAT. (<30% capacity) Charger Fail AC fail 2-3 closed closed open 1-3 open open closed ----- ----- ----- ----- DC OK 5-6 closed closed closed 4-6 open open open ----- ----- ----- ----- Battery low/Abnormal /Disconnected 8-9 7-9 open closed closed open closed open Charger fail 11-12 ------------- 10-12 ------------- open closed ----- ----- ----- ----- open closed Table 1.1 Explanation of alarm signal "Terminal torque 7 Lb-in" +V +V -V -V GND 3.3V RTH- RTH+ A1 A0 Force Button DC OK "Terminal torque 2 Lb-in" 1 2 3 4 5 6 7 8 9 10 11 12 AC Fail DC OK Battery Charger Low Fail AC Fail Status Communication Port(RJ45) DRS-480-24 Battery Start INPUT: 100-277VAC 5.4A OUTPUT: 24V 50/60Hz Max.20A BAT. 24V Max.15.4A Total Power: Max. 480W "Use copper wire only" "Maximum surrounding air temperature: 50" 35-122254 Charging "Install in a pollution degree 2 environment" Current Adj. MEAN WELL ENTERPRISES CO.,LTD. No. 28,Wuquan 3rd Rd., Wugu Dist., New Taipei City 24891, Taiwan Manual:www.meanwell.com/manual.html MW02 MADE IN CHINA "Terminal torque 7 Lb-in" BAT- BAT+ "Terminal torque 9 Lb-in" N L Fig 1.1 alarm signal Terminals AC fail (Battery low) 3 21 R V External voltage source (V) and resistor (R) (The max. Sink is 1A and 30Vdc) Fig 1.2 Internal circuit of AC fail (Battery low), via relay contact File Name:DRS-480-SPEC 2023-11-16 Downloaded from Arrow.com. 480W All-In-One Intelligent Security Power DRS-480 series 2.DC-UPS function When AC mains drops below:79~89VAC of 120VAC,132~187VAC of 220VAC, UPS function will activate and power source switch battery backup. AC mains MODBus Communication (CANBus optional) Battery start Charging Button Battery Load Output Signals/Form C AC fail DC OK Battery low/Abnormal/Disconnected Charger fail 3.Charger setting 3.1.1 2 or 3-stage selectable by DIP S.W This series provides 2 or 3 stage charging curve. 1 OFF: 3 stage(Default), ON: 2 stage 2 Charging curve adjustable:see below 3 18 ON 123 +V +V -V -V 21 43 65 CN12 87 DC OK AC Fail Status AC Fail DC OK Battery Charger Low Fail Communication Port(RJ45) Battery Start Charging Current Adj. BAT- BAT+ N L 3.1.2 Charging curve can be adjustable by DIP S.W 2 stage charging curve Start V boost Charge Voltage 100% CC Charge Current Constant Current Constant Voltage Cut off for stop charging 10% CC Color of LED Loading Indicator stage 1 stage 2 Orange Battery Full Green Default 3 stage charging curve Start Charge Voltage Charge Current Constant Current Constant Voltage Color of LED Loading Indicator stage 1 stage 2 Orange V boost V float Float stage 3 Green 100% CC 10% CC State Constant Current Vboost DRS-480-24 15.4A 28.8V DRS-480-36 10.2A 43.2V DRS-480-48 7.7A 57.6V Suitable for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese). State DRS-480-24 DRS-480-36 DRS-480-48 Constant Current 15.4A 10.2A 7.7A Vboost Vfloat 28.8V 27.6V 43.2V 41.4V 57.6V 55.2V Suitable for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese). The default curve is programmable, whereas other pre-defined curves can be activated by the means of the DIP S.W; please refer to the table below and the Mechanical Specification. File Name:DRS-480-SPEC 2023-11-16 Downloaded from Arrow.com. 480W All-In-One Intelligent Security Power DRS-480 series Embedded 2 stage charging curve DIP SW position 24V model 2 3 Description CC(default) Vboost OFF OFF Default, programmable 28.8 ON OFF Pre-defined, gel batter 28.0 15.4A OFF ON Pre-defined, flooded battery 28.4 ON ON Pre-defined, AGM battery,LiFe04 29.2 DIP SW position 36V model 2 3 Description CC(default) Vboost OFF OFF Default, programmable 43.2 ON OFF Pre-defined, gel battery 42 10.2A OFF ON Pre-defined, flooded battery 42.6 ON ON Pre-defined, AGM battery,LiFe04 43.8 DIP SW position 48V model 2 3 Description CC(default) Vboost OFF OFF Default, programmable 57.6 ON OFF Pre-defined, gel battery 56.0 7.7A OFF ON Pre-defined, flooded battery 56.8 ON ON Pre-defined, AGM battery,LiFe04 58.4 Embedded 3 stage charging curve DIP SW position 24V model 2 3 Description CC(default) Vboost OFF OFF Default, programmable 28.8 ON OFF Pre-defined, gel batter 28.0 15.4A OFF ON Pre-defined, flooded battery 28.4 ON ON Pre-defined, AGM battery,LiFe04 29.2 DIP SW position 36V model 2 3 Description CC(default) Vboost OFF OFF Default, programmable 43.2 ON OFF Pre-defined, gel battery 42 10.2A OFF ON Pre-defined, flooded battery 42.6 ON ON Pre-defined, AGM battery,LiFe04 43.8 DIP SW position 48V model 2 3 Description CC(default) Vboost OFF OFF Default, programmable 57.6 ON OFF Pre-defined, gel battery 56.0 7.7A OFF ON Pre-defined, flooded battery 56.8 ON ON Pre-defined, AGM battery,LiFe04 58.4 Vfloat 27.6 27.2 26.8 28.0 Vfloat 41.4 40.8 40.2 42.0 Vfloat 55.2 54.4 53.6 56.0 3.2 SBP-001 can adjust the charging curves (Only CANBus Model) 2 stage charging curve (programable) 3 stage charging curve (programable) DIP SW position 24V model 2 3 Description CC(default) Vboost OFF OFF Default, programmable 15.4A 28.8 DIP SW position 24V model 2 3 Description CC(default) Vboost OFF OFF Default, programmable 15.4A 28.8 DIP SW position 36V model DIP SW position 36V model 2 3 Description CC(default) Vboost 2 3 Description CC(default) Vboost OFF OFF Default, programmable 10.2A 43.2 DIP SW position 48V model OFF OFF Default, programmable 10.2A 43.2 DIP SW position 48V model 2 3 Description CC(default) Vboost 2 3 Description CC(default) Vboost OFF OFF Default, programmable 7.7A 57.6 OFF OFF Default, programmable 7.7A 57.6 Vfloat 27.6 Vfloat 41.4 Vfloat 55.2 SBP-001 is a programmer, particularly for MEAN WELL's various programmable battery charger models to program the parameters of charging curves, such as the Constant current (CC), tapper current(TC), Constant voltage (CV), float voltage (FV) and so on, to accommodate the diversified battery specification in industry. With the design accounting for simplicity and convenience, users can easily configure MEAN WELL's programmable battery chargers with SBP-001 programmer and the computer; all of the setups are able to be finished easily by the means of the specific software. Note:(1) Tapper current(TC) default is 10%, can be fine tuned from 2% to 30% by SBP-001 with computer or CANBus Interface. (2) The SBP-001 only supports CANBus version(DRS-480-xxCAN is optional). (3) Please contact MEAN WELL for more details. File Name:DRS-480-SPEC 2023-11-16 Downloaded from Arrow.com. 480W All-In-One Intelligent Security Power DRS-480 series To the personal computer USB port (Type A) (DRS-480-xxCAN) 2 1 10 9 10 pins (HRS DF11-10DS) 1 UART_RX PMBUS_D CANH 5V 3.3V 9 2 UART_TX PMBUS_C CANL GND GND 10 SBP-001 LED 5V(Orange) 3.3V(Green) , USB Smart programmer (Sold separately) To the programmer (Mini USB) User Interface: Charging curve adjustable 2 or 3-stage selectable Model selection Downloaded from Arrow.com. Charging timeout setting File Name:DRS-480-SPEC 2023-11-16 SBP#2 50 480W All-In-One Intelligent Security Power Communication cable for DRS series 10 9 (SBP-001) 87 65 43 21 CANbus UL1061 28AWG 10 9 PMbus 87 65 43 21 10 HRS DF11-10DS or equivalent 180 150 CAT.5e 24AWG PVC UTP DRS-480 series 10 1 8 RJ45 or equivalent (DRS series) DRS series pin assigment : Connector Pin Assigment SBP-001 10pin connector (Connector part No.:HRS DF11-10DS) 10 9 1 2 3 4 5 6 (CANH) (CANL) 7 8 9 10 (GND) 21 DRS-480 RJ45 Communication port ----- ----- ----- ----- 6 7 ----- ----- ----- 8 Wire color ----- ----- ----- ----- Green White/Brown ----- ----- ----- Brown 3.3 Communication interface Charging parameters can be modified by MODBus (Built-in) or CANBus(optional) communication commands. For details, please refer to: http://www.meanwell.com/manual.html 4.Power Boost Mode The maximum current on the load output is the 2 times the rated current for 4 minutes max. and 3 times the rated current for 4 seconds max. For example (48V model): Output load power 10A power BAT. 20A max.4min. power BAT. BAT. 30A max.4sec. File Name:DRS-480-SPEC 2023-11-16 Downloaded from Arrow.com. 480W All-In-One Intelligent Security Power 5.Battery temperature compensation RTH- RTH+ 8 pins (JS-2008R-2*4-T) DRS-480 series Extend cable by customer Bat-- +Bat + (NTC) Battery AC Input To exploit the temperature compensation function, please attach the temperature sensor(NTC) which is enclosed with DRS-480, to the battery or the battery's vicinity. DRS-480 is able to work normally without the temperature sensor(NTC). 5.1 The compensation parameters included Disable, -3, -4 and -5mV/ /Cell .It can be modified by communication command of CANBus, MODBus. The factory default value is -3mV/ /Cell. 5.2 It will be regarded as normal temperature and will not be compensated when temperature compensation resistance is not connected; And temperature compensation will only compensate lead-acid battery, not lithium iron battery. 5.3The range of temperature compensation is 0-40 , normal temperature 25 is the central value, no compensation; When the temperature is < 0 or > 40 , the current temperature compensation value will be limited to 0 or 40. 24V model as an example Assuming that Vboost=28.8V, temperature compensation set to -5mV//Cellby communication, TEMP_bat is NTCtemperature detection. The compensating voltage can be calculated by the following equation: Vboost_comp=28.8V-5mV*(TEMP_bat -25)*12Cell Max. compensation voltage: Vboost_H=28.8V-5mV*(0-25)*12Cell=30.3V Min. compensation voltage: Vboost_L=28.8V-5mV*(40-25)*12Cell=27.9V Downloaded from Arrow.com. File Name:DRS-480-SPEC 2023-11-16 480W All-In-One Intelligent Security Power DRS-480 series 5.4 Accessory List NTC Sensor and mating wire along with DRS-480 (Standard accessory) Item NTC sensor wire 1 Part No.: NGS05C250J5 Quantity 50 7 1 UL2468 24x2C NTC(RTH+) NTC(RTH-) Mating wire 50 7 2 UL1007 28AWG 1 JS-2007-2*4-T or equivalent Connect to DRS-480 Connection Diagram Extend cable by customer Connected Connect to battery Downloaded from Arrow.com. File Name:DRS-480-SPEC 2023-11-16 480W All-In-One Intelligent Security Power DRS-480 series 6.LED alarm Function DC OK DC fail DC OK Description AC fail AC fail AC OK Charging status Float Charging: CC/CV Discharging Charger fail Status Battery overvoltage / Battery reverse polarity System diagnosis Battery low / No Battery Battery discharge peak power timeout. Over load / short Over temperature Timeout Output of alarm OFF Green Red OFF Green Orange Orange: 1 Blink/Pause Red : 1 Blink/Pause Red : 2 Blink/Pause Red : 3 Blink/Pause Red : 4 Blink/Pause Red : 5 Blink/Pause Red : 6 Blink/Pause Red : 7 Blink/Pause Downloaded from Arrow.com. File Name:DRS-480-SPEC 2023-11-16 480W All-In-One Intelligent Security Power DRS-480 series Suggested Application 1.Backup connection for AC interruption (1) Please refer to Fig2.1 for suggested connection. The power supply charges the battery and provides energy to the load at the same time when AC mains is OK. The battery starts to supply power to the load when AC mains fails. DRS Series Example of Application Load +- AC fail DC OK Battery low/ Abnormal/ Disconnecte Charger fail RJ45 RS-485 18 Communication Port MODBus communication(Standard models) Personal Computer RJ45 SBP-001 18 Communication Port smart programmable Personal Computer Charging curve programmable by CANBus(Optional models) RJ45 USBCAN 18 Bat-- +Bat + Battery AC Input Communication Port CANBus communication(Optional models) Personal Computer Fig 2.1 Suggested system connection (2) Backup time Backup time depends on: from the load current from the size of the batteries. The following table is an example (battery capacity at C10 discharge rate). Battery Load 10AH 20AH 50AH 100AH 1.5A 350min 13h 33h 67h 3A 125min 350min 17h 33h 5A 60min 180min 600min 20h 7.5A 35min 90min 350min 13h 10A 23min 60min 240min 10h 15A 13min 35min 125min 350min 200AH 133h 67h 40h 27h 20h 13h Downloaded from Arrow.com. File Name:DRS-480-SPEC 2023-11-16 480W All-In-One Intelligent Security Power Mechanical Specification 110 DRS-480 series Case No. 214C Unit:mm Terminal Pin No. Assignment (TB3) Pin No. Assignment 1,2 +V 3,4 -V 150.7 Terminal Pin No. Assignment (TB2) Pin No. Assignment 1,2 BAT.- 3,4 BAT. + 125.2 18 ON 123 TB3 1 234 +V +V -V -V 21 43 65 CN12 87 DC OK AC Fail Status TB4 1 2 3 4 5 6 7 8 9101112 AC Fail DC OK Battery Charger Low Fail Communication Port(RJ45) Battery Start Charging Current Adj. BAT- BAT+ 1 234 TB2 N L 1 23 TB1 Terminal Pin No. Assignment (TB4) Pin No. Assignment 1,2,3 4,5,6 7,8,9 AC fail DC OK Battery low/ Abnormal/ Disconnected 10,11,12 Charger fail Terminal Pin No. Assignment (TB1) Pin No. Assignment 1 FG 2 AC/N 3 AC/L Force button Connector (CN12): JS-2008R-4*2-T or equivalent Pin No. 1 2 3 4 5 6 7,8 Assignment 3.3V GND RTH+ RTHA0 A1 Open: Normal Short: Force start Terminal Pin No. Assignment (RJ45) Pin No. Function Description 1,2,3,4,5 NC Retain for future use. 6 Data+ For MODBus model:Serial Date used in the MODBus interface. CANH For CANBus model:Date line used in the CANBus interface. 7 DataCANL For MODBus model:Serial Clock used in the MODBus interface. For CANBus model:Date line used in the CANBus interface. 8 GND-AUX Auxillary voltage output GND. The signal return is isolated from the output terminals(+V & -V). File Name:DRS-480-SPEC 2023-11-16 Downloaded from Arrow.com. 480W All-In-One Intelligent Security Power Installation Instruction DRS-480 series Back View 35 This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. ADMISSIBLE DIN rail:TS35/7.5 OR TS35/15 (For reference only. Not included with unit.) Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:DRS-480-SPEC 2023-11-16