Instructions for AcraDyne models including: LIT-MAN177, Gen IV Controller, LIT-MAN177 Gen IV Controller
www.aimco-global.com - /Data/Sites/1/manuals/
Manuals - Aimco Global
15 août 2022 — Port Number: TCP port number the controller listens on to accept an. Open protocol connection via. Ethernet. The default port is. 4545 and can be changed if.
Gen IV Controller Open Protocol Instructions The controller has the ability to accept an "Open" protocol connection. This connection is available over Ethernet and/or the standard serial ports. This connection allows you to enable/ disable the tool, set the active parameter set, collect rundown data, and much more. From the main menu, select Controller. Select Protocols. Then select Open Protocol. · Port Number: TCP port number the controller listens on to accept an Open protocol connection via Ethernet. The default port is 4545 and can be changed if required. · Cell ID: Optional variable passed through the Open Protocol Connection. · Channel ID: Optional variable passed through the Open Protocol Connection. · Controller Name: Optional variable passed through the Open Protocol Connection. To set up a serial port for Open Protocol, set the function on the desired COM port to "Open Protocol." · Cable Loss Detection: Used only for an Open Serial protocol connection. When set to 1, the controller will close the connection on a time-out. When set to 0 the controller will not close the connection (see the latest Open Protocol Specification for details on time-outs) and keep alive messages. · Connection Required: Determines whether an Open Protocol connection is required for the tool to operate. If checked, the tool will be disabled unless there is currently a connection. · Send MID with ID: Some versions of the Open protocol specification defines MID 52 with an ID and some define it without an ID. This option is used to meet both versions of the specification. · Connections: Currently active Open Protocol connections. Controller Supported MIDs Supported MID MID Description Revisions Note 1 Communication start 2 Communication start 1,2,3 1,2,3 acknowledge 3 Communication stop 4 Command error 5 Command accepted 8 Application data subscribe Support MID 900 curve data only 9 Application data unsubscribe Support MID 900 10 Parameter set ID upload request curve data only 11 Parameter set ID upload reply 12 Parameter set data upload request 13 Parameter set data upload reply Always returns a batch size of 0 14 Parameter set selected subscribe 15 Parameter set selected 16 Parameter set selected acknowledge 17 Parameter set selected unsubscribe 18 Select Parameter set 19 Set Parameter set batch size 20 Reset Parameter set batch counter 30 Job ID upload request 31 Job ID upload reply 34 Job info subscribe 35 Job info 36 Job info acknowledge 37 Job info unsubscribe 38 Select Job 39 Job restart 40 Tool data upload request 1,2 41 Tool data upload reply 42 Disable tool 43 Enable tool 50 Vehicle ID number download request 51 Vehicle ID number subscribe 1,2 52 Vehicle ID number 1,2 Has an option to send w/without IDs 53 Vehicle ID number acknowledge 54 Vehicle ID number unsubscribe 60 Last tightening result data 1-6,999 subscribe 61 Last tightening result data 62 Last tightening result data acknowledge 63 Last tightening result data unsubscribe 64 Old tightening result upload request Supported MID MID Description Revisions Note 65 Old tightening result upload reply 70 Alarm subscribe 71 Alarm 72 Alarm acknowledge 73 Alarm unsubscribe 76 Alarm status 77 Alarm status acknowledge 80 Read time upload request 81 Read time upload reply 82 Set time 90 Multi spindle status subscribe 91 Multi spindle status 92 Multi spindle status acknowledge 93 Multi spindle status unsubscribe 100 Multi spindle results subscribe 101 Multi spindle results 102 Multi spindle results acknowledge 103 Multi spindle results unsubscribe 113 Flash green light on tool 127 Abort Job 128 Job batch increment 129 Job batch decrement 130 Job off 150 Identifier download request 157 Reset all Identifiers 200 Set external controlled relays Only supports 0 (off) and 1 (on) 210 Status external monitored inputs subscribe 211 Status external monitored inputs 212 Status external monitored inputs acknowledge 213 Status external monitored inputs unsubscribe 214 IO device status request 1,2 215 IO device status reply 216 Relay function subscribe 217 Relay function 218 Relay function acknowledge 219 Relay function unsubscribe 241 User data subscribe See supported relay functions below. Out_1 - Pulse status 242 User data 243 User data acknowledge 244 User data unsubscribe (0= OK, 1 = Low, 2 = High) Out_2 - Pulses Out_3 - Undefined 900 Trace data 9999 Keep alive open protocol communication Out_4 - Undefined Trace type 1 & 2 only (angle & torque) Supported Relay Functions Supported Relay Functions Number Function 1 OK 2 NOK 5 Low Torque 6 High Torque 7 Low angle 8 High angle Supported Relay Functions Number Function 9 Cycle complete 10 Alarm 11 Batch NxOK 12 Job OK 19 Tool ready 20 Tool start switch Supported Relay Functions Number Function 21 Dir. switch = CW 22 Dir. switch = CCW 26 Tool running 145 Start Trigger Active 276 Cycle abort QUALITY · INNOVATION · SERVICE CORPORATE HEADQUARTERS 10000 SE Pine Street Portland, Oregon 97216 Phone: (503) 2546600 Toll Free: 1-800-852-1368 AIMCO CORPORATION DE MEXICO SA DE CV Ave. Cristobal Colon 14529 Chihuahua, Chihuahua. 31125 LIT-MAN177_OPENPROTOCOL Mexico 08-15-22 Phone: (01-614) 380-1010 ©2022 AIMCOAdobe PDF Library 16.0.7 Adobe InDesign 17.3 (Windows)