service manual for Mares models including: Mares, Instinct, Instinct 2nd Stage, 46201234 VERS.2, 46201234 VERS.3, SCUBA regulator, diving equipment, maintenance manual, technical assistance, poppet, diaphragm, O-ring

5817-indice 2010 INGLESE

Lara

INSTINCT ND STAGE

in this maintenance manual in the nitrox chapter (en 13949) before beginning reassembly! note before reassembling, lightly lubricate all the o-rings with silicone grease (type general electric versalube g-322). lubrication reduces the likelihood of damage during reassembly. 19. place the defl ector (50) in the centre of the beathing tube

PDF preview unavailable. Download the PDF instead.

8359bd 7fb6f04094604e899d4a69884464c4fd ?index=true
INSTINCT 2ND STAGE

INSTINCT 2ND STAGE

original copywriter 1987 revised 2012 - printed 2013

TECHNICAL BULLETIN 23

BTM23-1

RE: INSTINCT 2ND STAGE POPPET

BTM23

TECHNICAL ASSISTANCE DEPT. OF MARES S.p.A. INFORMS ALL MARES LAB PARTNERS ABOUT AN IMPROVEMENT MADE TO THE INSTINCT SECOND STAGE: A NEW POPPET 2nd STAGE (#46201234 VERS.2) INITIALLY MADE COMPLETELY OF METAL BUT THE FINAL PART WILL BE MADE IN DUAL COMPONENTS (VERS. 3) AS THE PICTURE SHOWN. THE FEATURE OF NEW POPPET ARE 4 GROOVES ON THE HEAD THAT ALLOW FOR A MORE FLOW OF AIR, AND THEREFORE MORE COMFORTABLE BREATHING AT ALL DEPTHS AND DIVING CONDITIONS. IN VARIOUS CASES, THE NEW 2ND STAGE POPPET ALSO SOLVES POSSIBLE CASES OF VIBRATION THAT CAN OCCUR IN CERTAIN INSTINCT SECOND STAGES WITH A PREVIOUS VALVE (VERS. 1).

- PHOTO 1 -

1

2

3

PREVIOUS

TEMPORARY

FINAL

*INITIALLY THE NEW SECOND STAGE POPPET (VERS. 2) WILL BE ASSEMBLED ON THE FOLLOWING MODELS, BEGINNING WITH THE SERIAL NUMBERS (S/N) LISTED BELOW:

CODICE 416164 416134

DESCRIZIONE INSTINT 12S INT INSTICT 52 SHE DIVES INT (JP)

S/N IS 13367 JS 10289

*FOR FURTHER INFORMATION ABOUT VERSION 3, PLEASE CONTACT TECHNICAL ASSITANCE ANYTIME.

! ATTENZIONE!
PER LE PROCEDURE DI SMONTAGGIO, RIMONTAGGIO, REGOLAZIONE E CONTROLLO DELLA SCATOLA SECONDO STADIO , E' NECESSARIO CONSULTARE LA PROCEDURA DI MANUTENZIONE DEL SUDDETTO. IN MANCANZA DEL MANUALE SI' PREGA DI CONTATTARE LA MARES PRIMA D'EFFETTUARE QUALSIASI INTERVENTO DI MANUTENZIONE, REGOLAZIONE E CONTROLLO.

original copywriter 1987 revision 2012 - printing 2013

REGULATORS

MAINTENANCE PROCEDURE
` TOOLS NEEDED
! WARNING!
ALL MAINTENANCE AND REPAIR PROCEDURES MUST BE PERFORMED BY A MARES AUTHORIZED SERVICE CENTER AND/OR DISTRIBUTOR. THEREFORE, THE INFORMATION PROVIDED BELOW IS INTENDED STRICTLY FOR TECHNICIANS AT SUCH CENTERS.
NOTE ALL OPERATIONS MUST BE CONDUCTED STRICTLY IN THE ORDER DESCRIBED.

IN ORDER TO ENSURE ADVANCED PERFORMANCE AND SAFETY DURING USE, AFTER 100 HOURS OF DIVING OR 1 YEAR THE REGULATOR MUST BE CHECKED, AND ITS CRITICAL PARTS MUST BE INSPECTED AND REPLACED IF NECESSARY.
· Phillips head screwdriver · Compressed air supply circuit or tank (180-200 bar) · Cutting nippers · O-Ring removal tool · Silicone grease (General Electric Versalube G-322 type) · Compressed air gun (8-10 Bar) · Descaling solution (Deox Extra type) or ultrasound tank · Test Bench · Carbon/Prestige/Rebel 2nd stage maintenance kit (code
46200296 ­ 46200297 VITON O-RING)

INSTINCT SECOND STAGE

S15-1

(B-6) # 46106206
(B-17) 17mm (2) # 46106217
(B-18) 14mm #46106218
Pliers (type Usag 133)
(B-12) 5.5mm #46106212
(B-4) 5mm #46106204
(S-1) #41106000
Hex wrench 4mm

S15-2

INSTINCT SECOND STAGE

REGULATORS

original copywriter 1987 revision 2012 - printing 2013

DISASSEMBLY We reccomend having the schematic to hand, to make the procedure easier.
1. Remove the dust cap and move the hose cover from the 1st stage. Photo 1. 2. Unscrew the hose (26) using a 14-mm open end wrench (B18). 3. Move the 2nd stage side hose protector (46). 4. Remove the mouthpiece (44) using with care cutting nippers.

5. Remove the Pin Cover (38) using tool B-22. 6. Take the Pin off with a pliers.

NOTE MAKE SURE TO REMOVE THE TOP PIN COVER (174) FROM THE HOSE CONNECTOR SIDE (28).
7. Push down the button (104) and slightly raise the cover (39).

original copywriter 1987 revision 2012 - printing 2013

REGULATORS

INSTINCT SECOND STAGE

8. Using tool S-1, release definitively the cover (39) over the 2nd stage case (32).

S15-3

9. Unscrew both screws (140) and remove the diaphragm Holder (78) and the diaphragm (142) too.

10. Remove the bottom Pin button (174) using tool B-22. Take the Pin off with a pliers. Make sure to remove the bottom Pin Button (174) as pictured. 11. Unscrew the hose connector (28) using a 17-mm open end wrench (B-17), and then pull out the by-pass retainer
ring (96).
12. Gently press out the demand lever connector assembly into the case and remove the O-Ring (83) from its seat in the second stage case (32).
NOTE IT IS NOT ADVISABLE TO PULL IT OUT BY DEMAND LEVER (35).

S15-4

INSTINCT SECOND STAGE

REGULATORS

original copywriter 1987 revision 2012 - printing 2013

13. Position the demand lever connector assembly on the special tool (B-6) and use the screwdriver (B-12) to unscrew the retaining nut (33) from the demand lever (35). Then remove the washer (34), the poppet assembly (30+47+92), and the spring (31).

14. Remove the poppet seat (47), pressing slightly on the poppet seat holder (92) in the direction of the threaded stem. Remove the poppet seat holder (92) from the stem of the 2nd stage valve shaft (30).
15. Unscrew the seat connector (21) from the case assembly connector (28) using a 5-mm hex wrench (B-4).

16. Remove the O-Ring (71) from the hose connector (28) and the O-Ring (27) from the seat connector (21). 17. Remove the exhaust tee (41) from the second stage case (32) and the exhaust valve (40) as well. 18.Remove the deflector (50).

original copywriter 1987 revision 2012 - printing 2013

REGULATORS

CLEANING AND CHECKS
For routine cleaning of reusable rubber components, wash all parts in a mixture of hot water and mild detergent, scrubbing if necessary with a soft brush. Do not use solvents or acids on rubber components.

! WARNING!
ACIDS OR OTHER SOLVENTS MAY DAMAGE PLASTIC AND RUBBER PARTS. BEFORE CLEANING METAL COMPONENTS, MAKE SURE THAT ALL SEALS AND OTHER PARTS SUBJECT TO DETERIORATION HAVE BEEN REMOVED.
Chrome-plated brass and stainless steel components can be cleaned using a nylon brush to remove any deposits, by immersing them in a fresh water ultrasound bath, or, if suitable equipment is not available, in a gentle acid solution (Deox Extra type) or white vinegar diluted with hot water.
Be sure to thoroughly rinse all parts in fresh water and dry with a jet of low pressure air at 8-10 bar before proceeding with reassembly.

INSTINCT - ROUTINE MAINTENANCE
! WARNING!
CERTAIN KEY COMPONENTS OF THE 2ND STAGE SHOULD BE REGULARLY REPLACED AT EACH SCHEDULED OVERHAUL. BELOW ARE LISTED THE COMPONENTS INCLUDED IN THE INSTINCT 2ND STAGE SERVICE KIT (#46201165 - #46201171 VITON O-RINGS):
` INSTINCT- INSTINCT OCTOPUS 2ND STAGE SERVICE KIT · DEMAND LEVER LOCK NUT (33) · 2ND STAGE RUBBER PAD (47) · EXHAUST VALVE (40) · MOUTHPIECE CLAMP (43) · O-RINGS :
I. 1 O-RING 106 (19) II. 2 O-RINGS 2025 (27) III. 2 O-RINGS 2068 (83) IV. 1 O-RING 2050 (71)

INSTINCT SECOND STAGE

S15-5

S15-6

INSTINCT SECOND STAGE

REGULATORS

REASSEMBLY

! WARNING!
IF THE FIRST STAGE IS USED FOR DIVES WITH OXYGEN-ENRICHED MIXTURES, STRICTLY FOLLOW ALL THE INSTRUCTIONS PROVIDED IN THIS MAINTENANCE MANUAL IN THE NITROX CHAPTER (EN 13949) BEFORE BEGINNING REASSEMBLY!

NOTE

BEFORE REASSEMBLING, LIGHTLY LUBRICATE ALL THE O-RINGS WITH SILICONE GREASE (TYPE GENERAL ELECTRIC VERSALUBE G-322). LUBRICATION REDUCES THE LIKELIHOOD OF DAMAGE DURING REASSEMBLY.

19.Place the Deflector (50) in the centre of the beathing tube as shown in the picture .
20. Install on exhaust valve (40) the Spoke (144), carefully pulling its silicone stem through the center hole of the second stage exhaust valve support.make sure that the Spoke (144).

! WARNING!
DO NOT PULL TOO HARD ON SILICONE STEM AS THIS MAY DAMAGE THE EXHAUST VALVE.
21. Use cutting nippers to cut the silicone stem at approximately half its length.

original copywriter 1987 revision 2012 - printing 2013

original copywriter 1987 revision 2012 - printing 2013

REGULATORS

22. Fit the O-Ring (71) in the seat of the case assembly connector (28) and fit the O-ring (27) in its place in the seat connector (21).
23. Insert and screw the seat connector (21) into the case assembly connector (28) using the 5-mm hex wrench (B-4) ntil it protrudes about 3 mm.
24. Reassemble the poppet seat holder (92) on the 2nd stage poppet stem (30).
25. Reassemble the poppet seat (47) in the poppet seat holder (92).
26. Place the 2nd stage poppet assembly (30-47-92) together with its spring (31) on the special tool (B-6).
27. Pressing gently, correctly position the 2nd stage valve and its spring into the demand lever connector (91) and hold it in place.

NOTE

TO ENSURE THAT THE 2ND STAGE POPPET STEM IS POSITIONED CORRECTLY IN THE DEMAND LEVER CONNECTOR HOLE, GENTLY ROTATE THE CONNECTOR LEFT AND RIGHT ON THE B-6 TOOL.

28. Properly position the demand lever (35) with respect to the by-pass hole in the metal insert (91) channel.
29. Fit the washer (34) on the poppet stem and tighten the demand lever adjusting nut (33) 7 or 8 full turns using the special wrench (B-20).
NOTE PRESS THE DEMAND LEVER A FEW TIMES TO BE SURE IT IS ABLE TO MOVE FREELY.

INSTINCT SECOND STAGE

S15-7

S15-8

INSTINCT SECOND STAGE

REGULATORS

30. Correctly position the demand lever connector assembly (91) in the 2nd stage case (32).
I. Move in the opposite position the demand lever (35) on the Insert (91).
II. Set up it as shown and rotate it (91) in the case (32). 31. Hold the demand lever connector in place in the second
stage case by hand, insert the O-Ring (83) into the seat between the 2nd stage case and the demand lever connector using the special wrench (B-6). 32. Hold the demand lever connector in place in the second stage case by hand, insert the O-Ring (83) into the seat between the 2nd stage case and the demand lever connector using the special wrench (B-6).
NOTE IF USING A TORQUE WRENCH, USE TIGHTENING TORQUE OF 8 - 8.5 N/M.
33. Put the spacer ring (96) in place, and then use the 17mm open-end wrench (B-17) to fully lock down the case assembly connector (28) in the 2nd stage case. Press the demand lever a few times.
34. Fit the O-Ring (27) in the seat on the swivel connector of the hose (26) and the O-Ring (19) in the seat of the metal coupler that screws into the to first stage.
35. Screw the hose (26) into the case assembly connector (28) using a 17-mm open end wrench (B-17).

original copywriter 1987 revision 2012 - printing 2013
I II

original copywriter 1987 revision 2012 - printing 2013

REGULATORS

INSTINCT SECOND STAGE

S15-9

FINAL ADJUSTMENTS
To correctly adjust the regulator:
a. The repair shop should be equipped with a high- and low-pressure compressed air supply. b. A pressure gauge is required for checking the intermediate pressure (the pressure gauge should have a full scale
value MAX 30-40 BAR, for greater adjustment accuracy). I. Screw the intermediate pressure measuring gauge into one of the 3/8" low-pressure ports on the 1st stage, using
the wrench (B-18). II. Mount the regulator group on the control valve (of the tank or test bench). III. Holding down the second stage demand lever, slowly open the tank valve and, almost simultaneously, release the
demand lever. IV. Read the pressure gauge to check whether the 1st stage pressure is correct.

! WARNING!
THE FIRST STAGE INTERMEDIATE PRESSURE MUST BE MEASURED WHEN THERE IS NO AIR COMING OUT OF THE 2ND STAGE. FOR ANY NECESSARY 1ST STAGE ADJUSTMENTS, REFER TO THE CORRESPONDING MANUAL.

! WARNING!
ALL THE ADJUSTMENTS BELOW MUST BE MADE WITH THE SECOND STAGE CONSISTENTLY SUPPLIED WITH THE CORRECT INTERMEDIATE PRESSURE.
36. Assemble the button Spring (102) on the Ring Diaphragm (78) and over it place the button (104). Using the Pin (102) Fixed the Button (104) through right side.

37. Place the 2nd stage diaphragm (142) in the Ring Diaphragm (78). 38. Fit both screws (140) on the Housing (32).

S15-10

INSTINCT SECOND STAGE

REGULATORS

original copywriter 1987 revision 2012 - printing 2013

39.Pushing down the button (104), insert Cover (39).Fix first its teeth (bottom), release the Button (104) set up the cover in the proper position.

40. Assemble the Pin (102) Fixed the Cover (39) through right (hose connector) side.
41. Gently move exhaust valve (40) and the Spoke (144). Working through the hole in the second stage case, use the wrench (B-12) to lock down or back off the demand lever nut (32) in order to adjust the demand lever (35).

original copywriter 1987 revision 2012 - printing 2013

REGULATORS

INSTINCT SECOND STAGE

S15-11

! WARNING!
THE DEMAND LEVER IS ADJUSTED CORRECTLY WHEN YOU CAN PRESS THE PURGE BUTTON ON THE COVER DOWN ABOUT 3MM BEFORE AIR BEGINS TO RELEASE. IN ADDITION, THE SOUND OF THE DEMAND LEVER TOUCHING THE METAL DISK OF THE SECOND STAGE DIAPHRAGM AS IT MOVES ("TAPPING") SHOULD BE AUDIBLE WHEN THE PRESSURIZED SECOND STAGE IS SHAKEN VIGOROUSLY UP AND DOWN.
42. Make sure the Spoke (144) is returned to its proper position after lever height adjustment.

S15-12

INSTINCT SECOND STAGE

TEST BENCH

original copywriter 1987 revision 2012 - printing 2013
OBJECT: REGULATORS TEST BENCH

INFORMAZIONI IMPORTANTI TO CHECK THE HIGH PRESSURE (2) MARES RECOMMEND HP AIR BETWEEN 150 TO 200 BAR!
CHECK THE INTERMEDIATE PRESSURE (IP), ON THE LP GAUGE AND ADJUST IT IF NECESSARY. TO DOWNLOAD THE AIR FROM REGULATOR THE "DISCHARGE LEVER" (5) CAN BE USED.

TANK PRESSURE

IP PRESSURE

DISCHARGE LEVER

· INSTALL THE INHALING MOUTHPIECE (8) ON THE SECOND STAGE MOUTHPIECE TUBE.

· TO CHECK THE CRACKING EFFORT USING COLUMN WATER (SEE INFO TABLE).

NOTE

...THE CRACKING EFFORT MUST BE READ IN THE MOMENT THAT THE VALUE OF INTERMEDIATE PRESSURE STARTS TO DECREASE...

original copywriter 1987 revision 2012 - printing 2013
2° STAGES CRACKING EFFORT

TEST BENCH

2° STADIO PRIMARY OCTOPUS

cm of H2O 2.8- 3.2 ~
3.3-3.5

inch of H2O 1,1-1.3
1,2-1,4

NOTE

TO OBTAIN THE CRACKING EFFORT IT IS NECCESSARY TO ADD THE VALUE OF COLUMN WATER THAT GOES UP WITH THE VALUE OF COLUMN WATER THAT GOES DOWN (OR REDOUBLE ONE OF THEM).

NOTE

SOMETIMES THE GRADUATION OF COLUMN WATER IS ALREADY REDOUBLED (1 REAL CM = 2 ON GRADUATION OF COLUMN WATER).

· CLOSE THE TANK VALVE (3) AND DISCHARGE THE RESIDUAL AIR, PUSHING ON THE SECOND STAGE BUTTON COVER OR THE DISCHARGE LEVER (5).
· CLOSE THE TEST BENCH VALVE (3) AND TRY TO INHALE DIRECTLY FROM THE SECOND STAGE (W/O INHALING MOUTHPIECE (8), IN ORDER TO DETECT LEAKEAGE INSIDE OF THE CASE.

INSTINCT SECOND STAGE

S15-13

S15-14

INSTINCT SECOND STAGE

REGULATORS

FINAL ASSEMBLY
! WARNING!
FOR CHECKS AND ADJUSTMENTS ON THE SECOND STAGE, CONSULT THE CORRESPONDING SECTION OF THE MAINTENANCE MANUAL (S 9-1).
43.Assemble the exhaust tee (41) on the support flange on the second stage.
44. Carefully assemble the mouthpiece (44), securing it with a new mouthpiece clamp (43).

original copywriter 1987 revision 2012 - printing 2013

S15-15 2nd STA GE INSTINCT

Drawing No: E 42

2nd STAGE INSTINCT

original copywriter 1987 revision 2012 - printing 2013
DRAWING UPDATED: 01/10/2012

original copywriter 1987 revision 2012 - printing 2013

Table No: 132

2nd STAGE INSTINCT

2 n d S TA G E I N S T I N C T S15-16
TABLE UPDATED ON: 18/12/2012

REF

CODE

DESCRIPTION

19

46110106 OR 106

19

46110402 OR 106 VITON 610-97507

21

46200204 POPPET SEAT

26

46201200 LP HOSE SFX BLACK 3/8" , 65 CM (26-45-46)

26

46200886 LP HOSE SFX YELLOW

27

46110205 OR 2025

27

46110411 OR 2025 VITON 010-9707

28

46184282 HOSE CONNECTOR

30

46201234 POPPET METAL BODY, INSTINCT

31

46185059 POPPET SPRING

32

46201204 2ND STAGE CASE, INSTINCT

33

46185051 LOCKNUT, DEMAND LEVER 2ND STAGE

34

46185049 WASHER, DEMAND LEVER

35

46201241 DEMAND LEVER, INSTINCT

39

46201203 COVER FOR 2° STG P. METAL

40

46201194 EXHAUST VALVE,D. 33

41

46201201 EXHAUST TEE INSTINCT

43

47157984 CLAMP BK

44

46200855 MOUTHPIECE BK (10 PICS)

45

46201077 HOSE PROTECTOR 1ST STG 2K9

46

46200768 HOSE PROTECTOR 2ND STG

47

46184062 RUBBER SEAT

50

46201199 DEFLECTOR

REF

CODE

DESCRIPTION

71

46110211 OR 2050

71

46110413 OR 2050 VITON 014-9707

78

46201198 RING-DIAPHRAGM

83

46110225 OR 2068

83

46110420 OR 2068 VITON

91

46201181 INSERT FOR DEMAND LEVER

96

46184280 SPACER RING BY-PASS BK

96

46187038 SPACER RING BY-PASS YL

102

46201138 BUTTON SPRING

104

46201197 BUTTON BLACK

104

46201208 BUTTON YELLOW

140

46187004 SCREW M2X5

142

46187009 OVAL DIAPHRAGM

144

46201196 EXHAUST VALVE SPOKE

172

46201195 COVER FRAME, CHROME

174

46201188 PIN BUTTON/COVER

ASSEMBLED

S

46201165 SERVICE KIT 2ND STG INSTINCT

46201171 SERVICE KIT INSTINCT VITON

(19 - 27 - 33 - 40 - 43 - 47 - 71 - 83)

R

46200510 KIT RETROFIT (21-27-47)


Mac OS X 10.10.3 Quartz PDFContext PScript5.dll Version 5.2.2

Related Documents

Preview Mares Puck 4 Dive Computer Instruction Manual
This comprehensive instruction manual guides users through the features, operation, and maintenance of the Mares Puck 4 Dive Computer. It covers diving modes, settings, alarms, multi-gas capabilities, bottom timer mode, technical specifications, care instructions, warranty, and disposal.
Preview Mares Diving Equipment Service Manual and Technical Bulletins
This document provides comprehensive service manuals and technical bulletins for Mares diving regulators. It includes detailed maintenance procedures, parts diagrams, and component information for various Mares first stage models (e.g., MR22, MR42, 12S) and second stage components, along with specific technical updates and assembly instructions.
Preview Mares Dry Suit User Manual - Safety, Application, and Maintenance
Comprehensive user manual for Mares Dry Suits, covering safety warnings, CE certification, application, assembly, use, care, maintenance, and warranty information for SCUBA divers.
Preview Mares Puck Air 2 Dive Computer Instruction Manual
Comprehensive instruction manual for the Mares Puck Air 2 Dive Computer, covering operation, settings, diving procedures, maintenance, and technical specifications.
Preview Mares QUAD 2 Dive Computer Instruction Manual
Comprehensive instruction manual for the Mares QUAD 2 Dive Computer, covering its features, operation, settings, and safety guidelines for diving.
Preview Mares Puck 4 Dive Computer Instruction Manual
Comprehensive instruction manual for the Mares Puck 4 Dive Computer, detailing its features, operation, settings, dive modes, safety warnings, and maintenance for divers.
Preview Mares Quad Ci Color Dive Computer Instruction Manual
Comprehensive instruction manual for the Mares Quad Ci Color Dive Computer, covering operating modes, settings, diving with single and multiple gas mixtures, safety features, maintenance, and technical specifications. Learn to use your Mares Quad Ci for recreational and technical diving.
Preview Mares Quad Ci Color Dive Computer Instruction Manual
This instruction manual provides comprehensive guidance on operating the Mares Quad Ci Color Dive Computer, covering its features, functions, safety warnings, and maintenance for divers.