Instruction Manual for VEICHI models including: SI22, Solar Pump Inverter

VEICHI SI22 Solar Pump Inverter Manual(SIMPLE) V1.0

伟创电气有限公司

VEICHI SI22 Solar Pump Inverter Manual(SIMPLE) V1

SI22 Solar Pump Inverter Manual 5 Trial Run (1) Please double check the cable connection according to user manual. (2) Press “Start/Stop” button to run it, and check whether the pump rotary direction is correct. ;If the direction is correct ,please go to step(4);Otherwise,please go to step(3).

MANUEL

Index of /wp-content/uploads/2022/03

Télécharger Manuel

Variateur solaire VEICHI SI22 - 220V - Importation & Distribution

PDF preview unavailable. Download the PDF instead.

MANUEL
SI22 Solar Pump Inverter Manual
CONTENS
1. Security Tips.................................................................... 1 2. Technical Specification .................................................... 1 3. Product Model ................................................................. 1 4. Appearance and Dimension............................................. 2 5. Solar Pump Controller Wiring .......................................... 3 6. Basic Operation............................................................... 4

F2.00 : 1 F0.02 : 1 F2.29: 1
FE14: 20.00
FA.19=00

Terminal control Active relay Min Frquency Single phase motor

SI22 Solar Pump Inverter Manual

1. Security Tips

1. Only qualified personnel can operate the equipment. 2. AC power supply should not be connected with output ports U, V, W,
otherwise there is a danger of damage to frequency inverter. 3. After electrified, it is forbidden to contact internal wiring board and its parts.
Otherwise it will cause the danger of electric shock 4. User can only operate on it after 5 minutes when cut off power.

2. Technical Specification

Solar pump inverter
power(KW)

Pump

Rated power (KW)

Rated voltage(
V)

Max solar power input (KW)

Max DC input
voltage V

Recommend Voc voltage
(V)

Rated output curren
t(A)

Output frequency
(Hz)

SI22-D1 series, DC60-400VDC input, 3 phase 110-230VAC output, suitable for 110VAC pump

0.75

0.75

110

1.0

400

175~380

7A

0-320

1.5

1.5

110

1.95

400

175~380

10A

0-320

SI22-D3 series, D60V-400V input, 3 phase 220-240VAC output, suitable for 220VAC pump

0.75

0.75

220

1.0

400

360~400

4A

0-320

1.5

1.5

220

1.95

400

360~400

7A

0-320

2.2

2.2

220

2.86

400

360~400

10A

0-320

Note: SI22 products can also drive single phase pump and please select the

current-matched model.

3. Product Model

SI22 - D1 - 1R5G

Product Series

SI

Solar Pump Inverter

22

Series No.

Type

D3

DC311V,suitable for driving AC220V pump

D1

DC156V,suitable for

driving AC110V pump

Power

Code

Suitable Pump

R75G

0.75kw

1R5G

1.5kw

2R2G

2.2kw

Maximum power of D11.5kw Maximum power of D32.2kw.

1

SI22 Solar Pump Inverter Manual
4. Appearance and Dimension
2

SI22 Solar Pump Inverter Manual
5. Solar Pump Controller Wiring

 Standard Wiring for three phase motor

DC Power (60-400VDC) Input
(forward running)

output reactor

+

U

Solar Pump Inverter V

-

W

U
VM ~
W

+24V

shielded cables E
(grounding resistor lower than 10 )

DI COM

+24V DO
COM


shielded twisted pair line notice 1 +24V terminal maximum outputDC24V/100mA 2 DO terminal maximum output:DC24V/50mA

collector open loop terminal output

Notice1. 2.

stand for main circuit terminals. stand for control circuit terminals.

 Connection for single phase motor

L

V

L1

L2

L1

L2

C
N
With Capacitor LN connecting with UW

U

W

Without Capacitorconnecting with UVW

Note: The first connection solution for better performance is recommended.

3

SI22 Solar Pump Inverter Manual

6. Basic Operation

 Indicator and Key

Icon

Name Power Status
Start/Stop

Function
ON: The power is 60-400VDC. OFF: Power is abnormal. OFF: It is ready to run BLINKING: Fault or alarm comes ONThe four indicates will be on in turn and stand for output frequency is approaching to 30%50%70%90% of rated frequency in sequence
OFF Status: Press it to run ON Status: Press it to stop BLINKING Status : Press it to reset

 Dial-up and External Port

Icon

Name

Function

Keyboard Support optional keyboard

IOT
Quick Dial-up

Support optional IOT to access to online monitoringoffline data storage and WIFI hotspot
Default D1 for AC110V pump and D3 for AC220VC pump can be selected by quick dial-upany D1/D3 switch will only take effect after power on again

4

 Trial Run

SI22 Solar Pump Inverter Manual

1 Please double check the cable connection according to user manual.

2 Press "Start/Stop" button to run it, and check whether the pump rotary direction is correct.If the direction is correctplease go to step(4)Otherwiseplease go to step3.
3 Press "Start/Stop" button to stop it and change any two cables to adjust the directionPress "Start/Stop" button and then it will run smoothly.
4 Default setting for Start/Stop will store the operation command while power off. So it will automatically run or stop along with sunrise or sunset.
 Quick Troubleshooting
1Power is still off when connecting power: please check whether the
input voltage is 60-400VDC or check cable connections of solar array.  2  Status indicator is blinking: please reset it by pressing "START/STOP" for 1 second. Otherwiseplease ask for support.

5


Adobe PDF Library 10.0