Installation Guide for SDC models including: EA Series, Door Prop Exit Alarm
Exit alarm on door opening. • Manual or automatic alarm reset. • Integral LED status indicator. • Local 85dB Piezo buzzer alarm. • Door prop alarm after ...
SDC , Datasheets, Installation Instructions, Templates, Pricesheets
File Info : application/pdf, 5 Pages, 1.18MB
DocumentDocumentSECURITY DOOR CONTROLS WWW.SDCSECURITY.COM [t] 800.413.8783 805.494.0622 E-mail: service@sdcsecurity.com 801 Avenida Acaso, Camarillo, CA 93012 PO Box 3670, Camarillo, CA 93011 INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM Model EA-SN Model EA-728 Model EA-708 (cylinder not included) The SDC EA Series offers Exit Alarm, Forced Door Alarm, and Door Propped/Held Open Alarm monitoring capabilities to any controlled opening. It may be used as a standalone device or easily integrates with any access control system. Units are typically mounted adjacent to the opening, and provide local visual and audible alarm annunciation. An integral key switch is available for local bypass & alarm reset controls. A built-in alarm relay is also included for remote monitoring. FEATURES Exit alarm on door opening Door prop alarm after adjustable timed delay Manual or automatic alarm reset Local 85dB Piezo buzzer alarm Integral LED status indicator Main relay output for remote alarm notification Auxiliary relay output for door position status or bypass/alarm status Optional key reset/bypass switch Compact universal mounting EA SERIES TECHNICAL SPECIFICATIONS Input Power: 60mA @ 12 or 24VDC (Auto-sensing) Mounting: EA-SN: Single Gang, 1/4" Thick aluminum plate w/ security screws (2-1/8" depth recommended) EA-708, -728: Double Gang, 1/4" Thick aluminum plate w/ security screws Alarm Sound Level: 85dB @ 3ft, Piezo Buzzer Status Indicator: Bi-color LED Trigger (DPS) Input: Dry, N/C or N/O, field selectable Reset/Bypass (Control) Input: Dry, N/O or N/C, field selectable Alarm (Main) Output: Form C, 2A @ 30VDC (Resistive) Auxiliary Output: Form C, 2A @ 30VDC (Resistive) Wiring: Screw terminals Overall Dimensions: EA-SN: 5"h x 3.25"w x 1.625" d EA-708, -728: 5"h x 5"w x 1.875"d P:\INST INSTRUCTIONS\CONTROLS - ANNUNCIATORS\INST-DOOR PROP Rev B 07-21 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM [t] 800.413.8783 805.494.0622 E-mail: service@sdcsecurity.com 801 Avenida Acaso, Camarillo, CA 93012 PO Box 3670, Camarillo, CA 93011 EA Series Board Layout (Back View): 1 1 } PWR (-) 3 PWR (+) 2 2 3 4 }4 5 1s 60s }5 NO C NC }6 *The state of the Main & Aux. relays are shown when the unit is not NO C NC } powered. 7 1 Configuration Jumpers Numbered 1 through 5. By default, all jumpers have been set to OFF. Use the (5) supplied jumpers, as required. See the table below for a functional description of each jumper. Configuration Jumpers 1= Latching Alarm Jumper OFF Jumper ON Disabled (Alarm resets on door closure) Enabled. (Requires use of Control Input to reset an alarm OR Jumper #2) 2= Alarm Auto Reset Disabled Auto-reset 60 sec. after door closure. (Requires Jumper #1 to be ON) 3= Control Input Polarity Normally Open Normally Closed 4= DPS Input Polarity Normally Closed Normally Open 5= Aux. Relay Function Follows DPS Input Follows Bypass/Alarm State 2 Adjustable Alarm Timer Determines the amount of time a door can be propped open before an alarm is activated. Adjustable from 1 to 60 seconds. Turn clockwise to increase time. 3 Input Power Terminals Requires a 12 or 24VDC +/- 10% power supply (auto-sensing). 4 Control Input Terminals Dry input used for bypass & alarm reset. Field-selectable as normally open (default) or normally closed. In a secure state, a held input will bypass the unit. In an alarm state, a momentary input will reset the alarm providing the door is closed. This input is factory pre-wired for key switch model EA-728. 5 Door Contact Input Required for all models. Monitors the open/closed status of the door. Field-selectable as normally open or normally closed (default). 6 Alarm Relay Output Relay is energized when the unit is powered. An alarm state or loss of power will de-energize the relay. 7 Auxiliary Relay Output Relay may be configured to follow the DPS input OR to follow a bypass/alarm state. P:\INST INSTRUCTIONS\CONTROLS - ANNUNCIATORS\INST-DOOR PROP Rev B 07-21 Page 2 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM [t] 800.413.8783 805.494.0622 E-mail: service@sdcsecurity.com 801 Avenida Acaso, Camarillo, CA 93012 PO Box 3670, Camarillo, CA 93011 LED Status Indicator: Door Status Closed Open Open Closed Open Unit Condition LED Status Secure Solid Green G Pre-alarm (1-60 sec.) Solid Green G Alarm Solid Red R Bypassed Flashing Green G Bypassed Flashing Green G Aux. Relay* Aux. Relay Main Relay (Jumper 5 OFF) (Jumper 5 ON) Energized De-energized Energized Energized Energized Energized De-energized Energized De-energized Energized De-energized De-energized Energized Energized De-energized *Relay state shown with N/C Door Contact Key Switch Operation (EA-708 or 728 only): NOTE: Unit must be Secure to be Bypassed. Door must be closed to reset an alarm condition. EA-728 Bypass (Maintained) 90° Counter-clockwise. Key may be removed. Return to vertical position to re-secure. Alarm Reset (Momentary) 45° Clockwise. Key returns to vertical position upon release. EA-708 See Page 5 for Mortise Key Cylinder installation Bypass (Maintained) Turn counter-clockwise until ON/OFF switch is activated. Reactivate the switch to re-secure. Alarm Reset (Momentary) Turn clockwise until momentary switch is activated. EA Series Operational Modes: Wiring Example #1 Non-latching (auto-resetting) Exit Alarm or Door Prop Alarm. Opening the door will initiate the pre-alarm timer. Closing the door before the timer expires resets the timer. If the door remains open and the timer expires, an audible alarm will sound and the Main Relay will trigger. Alarm resets on door closure. Bypass the alarm by activating the integral key switch or via remote bypass switch. 12 or 24VDC P.S. N/C Alarm Relay for remote monitoring Power Supply: SDC Model TR-12, TR-24, or 600 Series N/O EA-SN: Optional Remote Bypass; Pre-wired for model EA-728 Door Contact: SDC Model MC-4 or similar Auxiliary Relay follow DPS input (a) All jumpers are set OFF (default) (b) Adjust the alarm delay timer (1-60 seconds), as required. (c) Install & terminate a N/C door contact. (d) Install & terminate optional output relays, as needed. See page 2 for relay descriptions. (e) Apply power & test. P:\INST INSTRUCTIONS\CONTROLS - ANNUNCIATORS\INST-DOOR PROP Rev B 07-21 Page 3 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM [t] 800.413.8783 805.494.0622 E-mail: service@sdcsecurity.com 801 Avenida Acaso, Camarillo, CA 93012 PO Box 3670, Camarillo, CA 93011 Wiring Example #2 Latching (Manually Reset) Exit Alarm/Door Prop Alarm. Opening the door will initiate the pre-alarm timer. Closing the door before the timer expires resets the timer. If the door remains open and the timer expires, an audible alarm will sound and the Main Relay will trigger & latch. Alarm must be reset by using the integral key switch (EA-708 or EA-728 only), or by remote control switch. Bypass the alarm by activating the integral key switch or via remote switch. 1 2 3 4 5 1s 60s PWR (-) PWR (+) 12 or 24VDC P.S. Power Supply: SDC Model TR-12, TR-24, or 600 Series N/O EA-SN: Requires Remote Reset Switch; Pre-wired for model EA-728 N/C NO C Alarm Relay for NC remote monitoring Door Contact: SDC Model MC-4 or similar NO C Auxiliary Relay changes state when the unit enters bypass mode or alarm mode NC (a) Jumpers 1 & 5 are installed. Jumpers 2, 3, & 4 are set OFF. (b) Adjust the alarm delay timer (1-60 seconds), as required. (c) Install Remote reset switch. Required for EA-SN; Optional for EA-708 or EA-728. (d) Install & terminate a N/C door contact. (e) Install & terminate optional output relays, as needed. See page 2 for relay descriptions. (f) Apply power & test. Wiring Example #3 Double-Door Latching Exit Alarm/Door Prop Alarm with Timed Reset. Opening the door will initiate the pre-alarm timer. Closing the door before the timer expires resets the timer. If the door remains open and the timer expires, an audible alarm will sound and the Main Relay will trigger & latch. The alarm will automatically reset 60 seconds after door closure. The alarm may also be reset by using the integral key switch (EA-708 or EA-728 only), or by remote control switch. Bypass the alarm by activating the integral key switch or via remote bypass switch. 1 2 3 4 5 1s 60s PWR (-) PWR (+) 12 or 24VDC P.S. Power Supply: SDC Model TR-12, TR-24, or 600 Series N/O EA-SN: Requires Remote Reset Switch; Pre-wired for the EA-728 N/C N/C NO C Alarm Relay for NC remote monitoring Door Contacts: SDC Model MC-4 (x2) NO C Auxiliary Relay changes state when the unit enters bypass mode or alarm mode NC (a) Jumpers 1, 2 & 5 are installed. Jumpers 3 & 4 are set OFF. (b) Adjust the alarm delay timer (1-60 seconds), as required. (c) Install Remote reset switch. Required for EA-SN; Optional for EA-708 or EA-728. (d) Install & terminate N/C door contacts in series. (e) Install & terminate optional output relays, as needed. See page 2 for relay descriptions. (f) Apply power & test. P:\INST INSTRUCTIONS\CONTROLS - ANNUNCIATORS\INST-DOOR PROP Rev B 07-21 Page 4 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM [t] 800.413.8783 805.494.0622 E-mail: service@sdcsecurity.com 801 Avenida Acaso, Camarillo, CA 93012 PO Box 3670, Camarillo, CA 93011 EA-708 Mortise Key Cylinder Installation: ASSEMBLY DETAIL SOUND DAMPENER All Exit Alarm Assemblies are shipped with a sound dampening cap loose in the box. Install the unit without the cap for full volume. Switch Mounting Bracket triangular tabs Locknut Install the unit with the cap as shipped for complete dampening. Install the unit with the center hole punched out for partial dampening Key Cylinder SDC Part# CYL-KD Or supply compatible 1" to 1-3/8" standard or interchangeable core mortise key cylinders (not included) Use tailpiece supplied with SDC Part# CYL-KD, or Ilco 863G-00-10 Standard Cam equivalent. Faceplate CENTER HOLE AS SHIPPED Adjustable Switch Assembly CENTER HOLE PUNCHED Ensure that the cam makes contact with the center of the switch plunger Complete the wiring connections by carefully routing the (2) white & (2) yellow wire leads behind the board. Terminate the (2) yellow wires to Control terminal "A". Terminate the (2) white wires to Control terminal "B". SWITCH WIRING (Reset) (Bypass) A YEL B WHT NO COM NO COM WHT YEL WHT YEL P:\INST INSTRUCTIONS\CONTROLS - ANNUNCIATORS\INST-DOOR PROP Rev B 07-21 Page 5Microsoft: Print To PDF