User Guide for MEAN WELL models including: RS-25, RS-25 Series 25W Single Output Switching Power Supply, RS-25 Series, 25W Single Output Switching Power Supply, Output Switching Power Supply, Power Supply, Supply
Блок живлення що вбудовується 25W 12V RS-25-12 MeanWell за ціною від 483.00 грн - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 2 Pages, 129.43KB
DocumentDocument25W Single Output Switching Power Supply RS-25 series GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx SPECIFICATION Features : Universal AC input / Full range User's Manual Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test No load power consumption<0.5W High efficiency, long life and high reliability 3 years warranty THOMAS SAMUEL THOMAS SAMUEL IS13252 AS/NZS62368-1 UL62368-1 GB4943.1 Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 R33100 RoHS TPTC004 IEC62368-1 MODEL RS-25-3.3 RS-25-5 RS-25-12 RS-25-15 RS-25-24 RS-25-48 OUTPUT DC VOLTAGE 3.3V 5V 12V 15V RATED CURRENT 6A 5A 2.1A 1.7A CURRENT RANGE 0 ~ 6A 0 ~ 5A 0 ~ 2.1A 0 ~ 1.7A RATED POWER 19.8W 25W 25.2W 25.5W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p VOLTAGE ADJ. RANGE 2.85 ~ 3.6V 4.75 ~ 5.5V 10.8 ~ 13.2V 13.5 ~ 16.5V VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% LOAD REGULATION Note.5 ±2.0% ±1.0% ±0.5% ±0.5% SETUP, RISE TIME 1800ms, 23ms/230VAC 4000ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 80ms/230VAC 14ms/115VAC at full load 24V 1.1A 0 ~ 1.1A 26.4W 120mVp-p 22 ~ 27.6V ±1.0% ±0.5% ±0.5% 48V 0.57A 0 ~ 0.57A 27.36W 200mVp-p 42 ~ 54V ±1.0% ±0.5% ±0.5% VOLTAGE RANGE 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY(Typ.) 73.5% 78.5% 81.5% 83.5% 86% 85% AC CURRENT (Typ.) 0.7A/115VAC 0.4A/230VAC INRUSH CURRENT (Typ.) COLD START 45A/230VAC LEAKAGE CURRENT <2mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & EMC (Note 6) WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION 110 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 55.2 ~ 64.8V Protection type : Shut off o/p voltage, clamping by zener diode -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH ±0.03%/ (0 ~ 50) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1, EAC TP TC 004, CCC GB4943.1, BSMI CNS15598-1, BIS IS13252(Part1):2010/IEC 60950-1: 2005 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020, CNS15936 Class B OTHERS NOTE EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 MTBF 3992.0K hrs min. Telcordia SR-332 (Bellcore) ; 663.3K hrs min. MIL-HDBK-217F (25) DIMENSION 78*51*28mm (L*W*H) PACKING 0.2Kg; 60pcs/13Kg/0.46CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:RS-25-SPEC 2024-11-22 Downloaded from Arrow.com. 25W Single Output Switching Power Supply Mechanical Specification (Unit: mm , tolerance ± 1mm) 6 7.62 +V ADJ. 1 2 3 4 2-M3 L=3 5 LED 55 78 25.4 51 RS-25 series Case No.931A 11 Terminal Pin No. Assignment Pin No. Assignment Pin No. 1 AC/L 4 2 AC/N 5 3 FG Assignment DC OUTPUT -V DC OUTPUT +V 14 max. 2-M3 Block Diagram I/P EMI FILTER FG RECTIFIERS & FILTER O.L.P. POWER SWITCHING PWM CONTROL 66.5 RECTIFIERS & FILTER DETECTION CIRCUIT 14 28 2.75 fosc : 60KHz +V -V Derating Curve Output Derating VS Input Voltage 100 Others 80 3.3V only 60 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () 100 90 80 70 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz LOAD (%) LOAD (%) Downloaded from Arrow.com. File Name:RS-25-SPEC 2024-11-22