User Manual for NOTIFIER models including: AM2020, AFP-1010, AFP-200, AFP-300-400, AFP-1010 Fire Alarm Control Panels, AFP-1010, Fire Alarm Control Panels, Alarm Control Panels, Control Panels, Panels
Notifier ROM Field Change Procedure - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 14 Pages, 1.50MB
DocumentDocument12 Clintonville Road, Northford, CT 06472-1610 USA 203-484-7161 FAX: 203-484-7118 www.notifier.com NOTIFIER is a company Field Change Procedure for the Notifier AM2020/AFP-1010, AFP-200, and AFP-300/400 Fire Alarm Control Panels, NOTI·FIRE·NETTM and Peripherals Software (ROM) Upgrade This procedure outlines the mechanical installation steps required to install AROM(n), NROM(n)-MET, ROM(n)-SCS, ROM(n)-TPI, NROM(n), VROM-(n), VRAM-1 and XRAM-1 chips in AM2020, AFP1010, AFP- 200, AFP-300/400, TPI-232, MET-1, NAM-232, RFX, NOTI·FIRE·NETTM and XP Transponder system boards. CAUTION System Reacceptance Testing after Software Changes - To insure proper system operation, this product must be tested in accordance with NFPA-72 requirements. The requirements for "Changes to all control units connected or controlled by the system executive software" include a 10-percent functional test of the system, which includes a test of at least one device on each input and output circuit to verify critical system functions such as notification appliances, control functions, and off-premises reporting. NOTI·FIRE·NETTM is a trademark of Notifier, 1994. www.PDF-Zoo.com firealarmresources.com K1 Document 15744 1/09/2004 Rev: P/N 15744:K2 ECN: 03-767 Installation Guidelines Handling Precautions for Integrated Circuits Static electricity can destroy Integrated Circuits (ICs)! To prevent damage to the ROMs being changed in this procedure, a wrist strap and a static-free IC insertion/ extraction tool is highly recommended. Notifier cannot be responsible for damage to ROMs or other integrated circuitry in the system as a result of improper handling techniques. Always keep ROMs on a static-free mat or surface. Static Control Wrist Strap 3M Series 2200 Charge Guard or equivalent Static-Free IC Insertion/Extraction Tool (select size & type suitable for use with the IC(s) which require extraction) Static-Free PLCC Extraction Tool (select size & type suitable for use with the PLCCs which require extraction) Static-Dissipative Work Surface 3M Series 8300 Charge Guard (or equivalent) connected to Earth Ground System Power Sources Always remove primary and secondary power before working on the system! 1) Disconnect battery backup power first by removing the Battery Interconnect Cable. 2) Proceed by disconnecting AC power to the panel at the main service circuit breaker (not the circuit breaker at the fire alarm control panel's power supply). 3) Wait 60 seconds to allow for capacitive discharge before touching any of the system's components. 4) Reverse the procedure for powering up the system -- AC first, then batteries. WARNING! Failure to follow this procedure can result in a loss of program memory. Pin 1 Integrated Circuit Pin Convention Notch Pin 1 Observe proper orientation of any IC removed or installed! Note location of pin 1 with respect to the notch in the body of the IC. The replacement ROM must be installed in the same manner as the ROM removed. Failure to observe this orientation will result in destruction of the ROM. DIP PLCC www.P2DF-Zoo.com firealarmresources.com Field Change Procedure 15744:K1 1/09/2004 AM2020/AFP1010 ROM Replacement Compatibility Warning To ensure complete compatibility between AM2020, AFP1010 boards and NOTI·FIRE·NETTM system boards, all ROMs in the system(s) must be changed at the same time. The control panel will not function properly with a mix of ROMs from different software levels. In addition, all ROMs from the same software level are not necessarily compatible. They must comprise a valid software combination. Consult the factory to determine whether or not your particular software part numbers will function as a group. The affected ROMs are listed in the table below. ROM(n) ROM Board(s) A1ROM(n)-CPU CPU-2 Central Processor Unit A1ROM(n)-DIA DIA-2 Display Interface Assembly A1ROM(n)-DIA DIA-1010 Display Interface Assembly AROM(n)-AMG AMG-1 Audio Message Generator AROM(n)-AMGX4 AMG-1 Audio Message Generator AROM(n)-AMGZC AMG-1 Audio Message Generator AROM(n)-AMGZCF AMG-1 Audio Message Generator AROM(n)-CPU CPU-2020 Central Processor Unit AROM(n)-DIA DIA-1 Display Interface Assembly AROM(n)-DIA DIA-2020 Display Interface Assembly AROM(n)-LCD LCD-80 Liquid Crystal Display AROM(n)-LIB LIB-200 Loop Interface Board AROM(n)-LIB2 LIB-400/LIB-200A Loop Interface Board AROM(n)-NIB NIB-96 Network Interface Board AROM(n)-SIB SIB-2048/SIB-2048A/SIB-NET Serial Interface Board (not the SIB-64 or SIB-232) AROM(n)-TPI TPI-232 Telephone Panel Interface AROM(n)-UZC UZC-256 Universal Zone Coder AROM(n)-XPP XPP-1 Transponder Processor Module N1ROM-(n) DIA-1010, CPU-2 and SIB-NET for NOTI·FIRE·NETTM NROM-(n) DIA-2020, CPU-2020 and SIB-NET for NOTI·FIRE·NETTM NROM-INA(n) INA Intelligent Network Annunciator for NOTI·FIRE·NETTM NROM(n)-MET MET-1 Media Evaluation Tool for NOTI·FIRE·NETTM NROM-NAM(n) AFP-200 FACP and NAM-232 Network Adapter Module NROMC-NAM(n) AFP-200 FACP and NAM-232 Network Adapter Module ROM(n)-NCM NCM and NCS-NCM ROM(n)-RFX RFX Wireless Interface ROM(n)-SCS SCS-8/SCS-8L Smoke Control Station Note: The (n) corresponds to a specific revision level of software. For example, AROM6-CPU is a CPU-2020 ROM containing Revision Level 6 software. ROM Installation 1) Disconnect secondary (DC) power. 2) Disconnect primary (AC) power. CAUTION! Remove AC power at the main service circuit breaker (not the circuit on the Main Power Supply) or all the programming information may be lost! 3) Replace each ROM as outlined in the respective sections. 4) Connect primary (AC) power. 5) Connect secondary (DC) power. 6) After all replacement ROMs have been installed, the entire system must be completely tested. Note: With the exception of new features, replacing the ROMs does not usually require re-entry of the system application program. 7) Please place all ROMs removed from the system into the static-protected boxes (provided with the replacement ROMs) and return them to the following address: ATTN: Software Engineering, Notifier, 12 Clintonville Road, Northford, Connecticut 06472-1653. www.PDF-Zoo.com Field Change Procedure 15744:K1 1/09/2004 3 firealarmresources.com AROM(n)-CPU / NROM (n) for CPU-2020 · Open the Display Interface Assembly (DIA) door. · Using an IC insertion/extraction tool, carefully remove ROM U2 from the CPU-2020 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U2 on the CPU-2020. U2 · Close the DIA door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. CPU-2020 Central Processing Unit A1ROM(n)-CPU / N1ROM-(n) for CPU-2 · Open the Display Interface Assembly (DIA) door. · Using an IC insertion/extraction tool, carefully remove ROM U2 from the CPU-2 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U2 on the CPU-2. U2 · Close the DIA door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. CPU-2 Central Processing Unit U4 DIA-1 Display Interface Assembly AROM(n)-DIA for DIA-1 · Open the Display Interface Assembly (DIA-1) door. Disconnect all cables to the DIA-1. · Remove the five screws that fasten the circuit board to the door. Remove the DIA-1 board and place it on an antistatic surface. · Using an IC insertion/extraction tool, carefully remove ROM U4 from the board and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the replacement ROM into the socket for U4 on the DIA-1. · Install the circuit board on the DIA-1 door. Connect the cables from the CPU-2020 (and a SIB if installed) to the DIA-1. · Close the DIA-1 door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. www.P4DF-Zoo.com firealarmresources.com Field Change Procedure 15744:K1 1/09/2004 U4 DIA-2 Display Interface Assembly U6 DIA-2020 Display Interface Assembly U6 DIA-1010 Display Interface Assembly A1ROM(n)-DIA for DIA-2 · Open the Display Interface Assembly (DIA-2) door. Disconnect all cables to the DIA-2. · Remove the five screws that fasten the circuit board to the door. Remove the DIA-2 board and place it on an antistatic surface. · Using an IC insertion/extraction tool, carefully remove ROM U4 from the board and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U4 on the DIA-2. · Install the circuit board on the DIA-2 door. Connect the cables from the CPU-2 (and a SIB if installed) to the DIA-2. · Close the DIA-2 door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. AROM(n)-DIA / NROM-(n) for DIA-2020 · Open the Display Interface Assembly (DIA-2020) door. Disconnect all cables to the DIA-2020. · Remove the six screws that fasten the circuit board to the door. Remove the DIA-2020 board and place it on an antistatic surface. · Using an IC insertion/extraction tool, carefully remove ROM U6 from the board and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U6 on the DIA-2020. · Install the circuit board on the DIA-2020 door. Connect the cables from the CPU-2020 (and a SIB if installed) to the DIA2020. · Close the DIA-2020 door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. A1ROM(n)-DIA / N1ROM-(n) for DIA-1010 · Open the Display Interface Assembly (DIA-1010) door. Disconnect all cables to the DIA-1010. · Remove the six screws that fasten the circuit board to the door. Remove the DIA-1010 board and place it on an antistatic surface. · Using an IC insertion/extraction tool, carefully remove ROM U6 from the board and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U6 on the DIA-1010. · Install the circuit board on the DIA-1010 door. Connect the cables from the CPU-2 (and a SIB if installed) to the DIA-1010. · Close the DIA-1010 door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. www.PDF-Zoo.com Field Change Procedure 15744:K1 1/09/2004 5 firealarmresources.com U2 LIB-200 Loop Interface Board AROM(n)-LIB / NROM-(n) / N1ROM-(n) for LIB-200 · Remove a LIB-200 from the system and place it on an antistatic surface. · Using an IC insertion/extraction tool, carefully remove ROM U2 from the LIB-200 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U2 on the LIB-200. · Install the LIB-200 in the system. · Repeat steps for each LIB-200 in the system. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. U108 U308 LIB-400 Loop Interface Board AROM(n)-LIB2 for LIB-400 · Remove the LIB-400 from the system and place it on an antistatic surface. · Using a Plastic Leaded Chip Carrier (PLCC) extraction tool, carefully remove ROM U108 and U308 from the LIB and place them on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROMs into the sockets for U108 and U308 on the LIB. · Install the LIB in the system. · Repeat steps for each LIB-400 in the system. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. U108 LIB-200A Loop Interface Board AROM(n)-LIB2 for LIB-200A · Remove the LIB-200A from the system and place it on an antistatic surface. · Using a Plastic Leaded Chip Carrier (PLCC) extraction tool, carefully remove ROM U108 from the LIB and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U108 on the LIB. · Install the LIB in the system. · Repeat steps for each LIB-200A in the system. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. www.P6DF-Zoo.com firealarmresources.com Field Change Procedure 15744:K1 1/09/2004 U14 SIB-2048 Serial Interface Board U15 SIB-NET Serial Interface Board AROM(n)-SIB for SIB-2048 · Open the Display Interface Assembly (DIA) door. · Using an IC insertion/extraction tool, carefully remove ROM U14 from the SIB-2048 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U14 on the SIB-2048. · Close the DIA door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. NROM-(n) / AROM(n)-SIB for SIB-NET · Open the Display Interface Assembly (DIA) door. · Using an IC insertion/extraction tool, carefully remove ROM U15 from the SIB-NET and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U15 on the SIB-NET. · Close the DIA door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. AROM(n)-SIB for SIB-2048A · Open the Display Interface Assembly (DIA) door. · Using an IC insertion/extraction tool, carefully remove ROM U15 from the SIB-2048A and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U15 on the SIB-2048A. · Close the DIA door. WARNING: Software must be compatible system-wide. U15 When not completely sure about compatibility, consult the factory before changing ROMs. SIB-2048A Serial Interface Board www.PDF-Zoo.com Field Change Procedure 15744:K1 1/09/2004 7 firealarmresources.com AMG-1 Audio Message Generator AROM(n)-AMG/X4/ZC/ZCF, VROM-(n) and VRAM-1 for AMG-1 · Remove dress panel covering the AMG-1. · Remove the four screws that affix the AMG-1's dress plate to the component board as illustrated at left. Remove the dress plate and disconnect the microphone and speaker connectors. · If replacing ROMs, carefully remove affected chips from the AMG1 using an IC insertion/extraction tool and place them on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Install the new AROM(n)-AMG/X4/ZC/ZCF, VROM-(n) or VRAM-1 chips in their respective positions as illustrated below. · Assembly of the AMG-1 is the reverse of removal. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. Speaker Connector Microphone Connector AROM(n)-AMG/X4/ZC/ZCF VROMA VROM-(n) Factory Programmed Message VROMB VROM-(n) Factory Programmed Message VRAMB VRAM-1 User Programmable Message VRAMA VRAM-1 User Programmable Message U5 INA Intelligent Network Annunciator NROM-INA(n) for INA · Open the Intelligent Network Annunciator (INA) door. · Using an IC insertion/extraction tool, carefully remove ROM U5 from the INA and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U5 on the INA. · Close the INA door. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. www.P8DF-Zoo.com firealarmresources.com Field Change Procedure 15744:K1 1/09/2004 U2 U3 XPP-1 Transponder Processor Module XRAM-1 for XPP-1 · Remove the XP Transponder Dress Panel. · Using an IC insertion/extraction tool, carefully remove RAM U3 from the XPP-1 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied XRAM-1 into the socket for U3 on the XPP-1. · Replace the XP Transponder Dress Panel. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. AROM(n)-XPP for XPP-1 · Remove the XP Transponder Dress Panel. · Using an IC insertion/extraction tool, carefully remove ROM U2 from the XPP-1 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U2 on the XPP-1. · Replace the XP Transponder Dress Panel. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. U3 U4 U9 FPGA NROM(n)-MET for MET-1 · Disassemble the MET-1 by removing the cover. For the MEDIA(n)-KIT, remove the MET-1 UBPCA upper board also. · With the power switch in the "Off" position, remove BT1 battery connector. · Using a PLCC extraction tool, carefully remove IC U9, U3 and U4 from the MET-1LBPC and place them on an antistatic surface. · Observe proper orientation and ensure that none of the pins are misaligned. Insert the supplied replacement NROM(n)MET into their correct sockets on the MET-1LBPCA. · Reassemble the MET-1. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. MET-1LBPCA (Lower Board) www.PDF-Zoo.com Field Change Procedure 15744:K1 1/09/2004 9 firealarmresources.com U9 NIB-96 Network Interface Board AROM(n)-NIB for NIB-96 · Locate and gain access to the NIB-96 in the cabinet. · Using an IC insertion/extraction tool, carefully remove ROM U9 from the NIB-96 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U9 on the NIB-96. · Reassemble the control panel. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. U3 LCD-80 Liquid Crystal Display AROM(n)-LCD for LCD-80 · Locate and gain access to the LCD-80 in the cabinet. · Using an IC insertion/extraction tool, carefully remove ROM U3 from the LCD-80 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U3 on the LCD-80. · Reassemble the control panel. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. U4 UZC-256 Universal Zone Coder AROM(n)-UZC for UZC-256 · Locate and gain access to the UZC-256 in the cabinet. · Using an IC insertion/extraction tool, carefully remove ROM U4 from the UZC-256 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U4 on the UZC-256. · Reassemble the control panel. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. www.P1D0 F-Zoo.com firealarmresources.com Field Change Procedure 15744:K1 1/09/2004 3 2 JP1 1 3 2 JP2 1 3 2 JP2 1 3 2 JP1 1 U8 NAM-232F Style A U8 NAM-232W Style A NROM-NAM(n) for NAM-232F, NAM-232W and NAM-232W/F · Locate and gain access to the NAM-232 in the cabinet. · Using an IC insertion/extraction tool for Style A or a PLCC extraction tool for Style C, carefully remove ROM U8 from the NAM-232 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U8 on the NAM-232. · Reassemble the control panel. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. U3 U8 ROM NAM-232W/F Style C NAM-232 Network Adapter Modules U9 AFP-200 Analog Fire Panel AFP-200 IC for use with NAM-232 · Locate and gain access to the AFP-200 in the cabinet. · Using an IC insertion/extraction tool, carefully remove ROM U9 from the AFP-200 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U9 on the AFP-200. · Reassemble the control panel. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. www.PDF-Zoo.com Field Change Procedure 15744:K1 1/09/2004 11 firealarmresources.com U16 AFP-300/400 Analog Fire Panel AFP-300/400 IC for use with NAM-232 · Locate and gain access to the AFP-300/400 in the cabinet. · Using an IC insertion/extraction tool, carefully remove ROM U16 from the AFP-300/400 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are bent. Insert the supplied replacement ROM into the socket for U16 on the AFP-300/400. · Reassemble the control panel. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. U3 U8 ROM NAM-232W/F MEDIA(n)-KIT for NAM-232W/F · Locate and gain access to the NAM-232 in the cabinet. · Using a PLCC extraction tool, carefully remove FPGA U3 from the NAM-232 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are misaligned. Insert the supplied replacement FPGA into the socket for U3 on the NAM-232. · Reassemble the control panel. U4 TPI-232 www.P1D2 F-Zoo.com ROM(n)-TPI for TPI-232 · Locate and gain access to the TPI-232. · Using a PLCC extraction tool, carefully remove ROM U4 from the TPI-232 and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are misaligned. Insert the supplied replacement ROM into the socket for U4 on the TPI-252. · Reassemble TPI-232 setup. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. firealarmresources.com Field Change Procedure 15744:K1 1/09/2004 U2 MIB-W Style C U2 MIB-WF Style C U2 MIB-F Style C U3 RPT-W Style C U3 MEDIA(n)-KIT for MIB-W/WF/F · Locate and gain access to the MIB-W/WF/F. · Using a PLCC extraction tool, carefully remove FPGA U2 from the MIB and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are misaligned. Insert the supplied replacement FPGA into the socket for U2 on the MIB-W/WF/F. · Reassemble the MIB. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. MEDIA(n)-KIT for RPT-W/WF/F · Locate and gain access to the RPT-W/WF/F. · Using a PLCC extraction tool, carefully remove FPGA U3 from the RPT and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are misaligned. Insert the supplied replacement FPGA into the socket for U3 on the RPT-W/WF/F. · Reassemble the RPT. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. RPT-WF U3 Style C RPT-F Style C www.PDF-Zoo.com Field Change Procedure 15744:K1 1/09/2004 13 firealarmresources.com Notch U4 NCS-NCW or NCS-NCF U5 NCM-W or NCM-F ROM(n)-NCM for NCM-W, NCM-F, NCS-NCW, and NCS-NCF · Locate and gain access to the network card. Open the NCS computer for NCS network cards. · Using a PLCC extraction tool, carefully remove U4 (NCS) or U5 (NCM) from the board and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are misaligned. Insert the supplied replacement ROM(n)-NCM into the socket for U4 or U5. U11 Notch RFX Board ROM(n)-RFX for RFX · Locate and gain access to the RFX. Open the RFX cabinet. · Using a PLCC extraction tool, carefully remove IC U11 from the RFX board and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are misaligned. Insert the supplied replacement ROM(n)-RFX into the socket for U11 on the RFX. U1 SCS-8 www.P1D4 F-Zoo.com U1 SCS-8L ROM(n)-SCS for SCS-8 and SCS-8L · Locate and gain access to the SCS-8/SCS-8L. To gain access to the SCS-8 remove the cover first. · Using a IC insertion/extraction tool, carefully remove IC U1 from the SCS-8/SCS-8L board and place it on an antistatic surface. · Observe proper orientation and ensure that none of the pins are misaligned. Insert the supplied replacement ROM(n)-SCS into the socket for U1 on the SCS. · Reassemble the SCS. WARNING: Software must be compatible system-wide. When not completely sure about compatibility, consult the factory before changing ROMs. firealarmresources.com Field Change Procedure 15744:K1 1/09/2004