Command Access Technologies
Mounting Instructions For "DL20" Door Loops
This diagram applies to all DL Series Door Loops.
Installation Steps
- Locate the centerline of the door loop on the underside of the Exit Device Housing, 4" from the soffit of the frame and 1" from the face of the door.
- Locate the centerline of the door loop for the face of the frame, 2" down from the edge of the Exit Device.
- Drill pilot holes (#24 drill) to mount the base and a 5/8" hole for wire conduit.
- Mount base using #10 SMS screws.
- Thread electrical wires through door loop.
- Install covers with #8 SMS screws.
Notes
Maximum electrical wires: 7 ea. 18 awg, 10 ea. 22 awg. Door Loop flexible conduit can be field cut.
Mounting Diagram Description
The diagram illustrates the installation of the DL-20 Door Loop relative to a Rim Exit Device and the Door Frame Face. It shows the door loop positioned on the underside of the exit device. A dimension line indicates 4 inches from the soffit of the frame. The door loop connects to the door frame face, with a dimension line indicating 2 inches down from the edge of the exit device. An alternate wall placement is indicated by a dashed outline, with a note to "Check loop slack."
Door Loop Base Dimensions
The diagram provides detailed dimensions for the door loop base. Key measurements include:
- Overall length: 2.379 inches
- Width of main body: 2.013 inches
- Hole diameters: 0.625 inches, 0.732 inches (two), 0.200 inches, 0.250 inches
- Other indicated dimensions: 0.732 inches.