User Manual for Shinko models including: HR-706 Channel 6 Point Temperature and Electrical Recorder, HR-706, Channel 6 Point Temperature and Electrical Recorder, Temperature and Electrical Recorder, Electrical Recorder
Papierowe rejestratory temperatury i procesów z serii HR-706 | acse.pl
Pliki do pobrania - Czujniki Temperatury, Regulatory i Rejestratory
File Info : application/pdf, 32 Pages, 5.85MB
DocumentDocumentHR-706 Operation Flow Chart CONTENTS Normal Operation Mode : Recording, Changing the Display, Engineering List Printing, Manual Printing, List Printing.......................................3 Setup Mode : Setting the Range (Current/Voltage, Thermocouple, Resistance temperature detector)................................................................4 Setup Mode : Setting the Range (scaling) .............................................................5 Setup Mode : Setting the Range (Square Root) ....................................................6 Setup Mode : Setting the Range (Decade)............................................................7 Setup Mode : Setting the Range (Difference, Sum, Average) ...............................8 Setup Mode : Setting the Range (Skip) .................................................................9 Setup Mode : Setting the Alarm...........................................................................10 Setup Mode : Setting the Unit.............................................................................. 11 Setup Mode : Setting the Chart Feed Speed, Setting the Date and Time ...........12 Setup Mode : Copying the Setting Data ..............................................................13 Setup Mode : Setting Other Functions(Printing Cycle, Zone Recording).............14 Setup Mode : Setting Other Functions(Partial Compression/Expansion) ............15 Setup Mode : Setting Other Functions(Digital Printing) .......................................16 Setup Mode : Setting Other Functions(Tag) ........................................................17 Setup Mode : Setting Other Functions(Comments) ............................................ 18 Engineering Mode : Alarm Hysteresis, Burnout ON/OFF .................................... 19 Engineering Mode : Channel Offset .................................................................... 20 Engineering Mode : Reference Junction Compensation ..................................... 21 Engineering Mode : Changing the Printing Color ................................................ 22 Engineering Mode : Recording RUN/STOP Trigger Setting, Channel/Tag Printing Selection, Alarm printing ON/OFF........................................... 23 Engineering Mode : Logging printing ON/OFF, Scale printing ON/OFF, Synchronous/Asynchronous ................................................... 24 Engineering Mode : Setting the Communication Function, Initializing the Setup Data ........................................................................................ 25 Engineering Mode : DI Functions........................................................................ 26 Engineering Mode : Temperature Unit Selection, Point Calibration..................... 27 Engineering Mode : Data Calibration(Voltage) .................................................... 28 Engineering Mode : Data Calibration (Resistance temperature detector) ........... 29 Engineering Mode : Data Calibration (Terminal Temperature) ............................ 30 Default value ................................................................................................ 31 WARNING When calibrating data, connect the equipment according to Section 9.5 of the instruction manual. Data calibration must be performed correctly. Operators possessing knowledge of electricity and control related matters should perform the calibration after careful reading of Sections 7.2 and 9.5 of the instruction manual. (Shinko Technos Co., Ltd. is not liable for damages incurred if calibration is performed other than prescribed in the instruction manual.) Normal Operation Mode : Recording, Changing the Display, Engineering List Printing, Manual Printing, List Printing 3 Setup Mode : Setting the Range (Current/Voltage, Thermocouple, Resistance temperature detector) 4 Setup Mode : Setting the Range (scaling) 5 Setup Mode : Setting the Range (Square Root) 6 Setup Mode : Setting the Range (Decade) 7 Setup Mode : Setting the Range (Difference, Sum, Average) 8 Setup Mode : Setting the Range (Skip) 9 Setup Mode : Setting the Alarm 10 Setup Mode : Setting the Unit 11 Setup Mode : Setting the Chart Feed Speed, Setting the Date and Time 12 Setup Mode : Copying the Setting Data 13 Setup Mode : Setting Other Functions(Printing Cycle, Zone Recording) 14 Setup Mode : Setting Other Functions(Partial Compression/Expansion) 15 Setup Mode : Setting Other Functions(Digital Printing) 16 Setup Mode : Setting Other Functions(Tag) 17 Setup Mode : Setting Other Functions(Comments) 18 Engineering Mode : Alarm Hysteresis, Burnout ON/OFF 19 Engineering Mode : Channel Offset 20 Engineering Mode : Reference Junction Compensation 21 Engineering Mode : Changing the Printing Color 22 Engineering Mode : Recording RUN/STOP Trigger Setting, Channel/Tag Printing Selection, Alarm printing ON/OFF 23 Engineering Mode : Logging printing ON/OFF, Scale printing ON/OFF, Synchronous/Asynchronous 24 Engineering Mode : Setting the Communication Function, Initializing the Setup Data 25 Engineering Mode : DI Functions 26 Engineering Mode : Temperature Unit Selection, Point Calibration 27 Engineering Mode : Data Calibration(Voltage) WARNING When calibrating data, connect the equipment according to Section 9.5 of the instruction manual. Data calibration must be performed correctly. Operators possessing knowledge of electricity and control related matters should perform the calibration after careful reading of Sections 7.2 and 9.5 of the instruction manual. (Shinko Technos Co., Ltd. is not liable for damages incurred if calibration is performed other than prescribed in the instruction manual.) 28 Engineering Mode : Data Calibration (Resistance temperature detector) WARNING When calibrating data, connect the equipment according to Section 9.5 of the instruction manual. Data calibration must be performed correctly. Operators possessing knowledge of electricity and control related matters should perform the calibration after careful reading of Sections 7.2 and 9.5 of the instruction manual. (Shinko Technos Co., Ltd. is not liable for damages incurred if calibration is performed other than prescribed in the instruction manual.) 29 Engineering Mode : Data Calibration (Terminal Temperature) WARNING When calibrating data, connect the equipment according to Section 9.5 of the instruction manual. Data calibration must be performed correctly. Operators possessing knowledge of electricity and control related matters should perform the calibration after careful reading of Sections 7.2 and 9.5 of the instruction manual. (Shinko Technos Co., Ltd. is not liable for damages incurred if calibration is performed other than prescribed in the instruction manual.) 30 Default value Setup mode Display Setting items Default value Remarks Engineering mode Display Setting items Default value Remarks Range (all channels) 1010mV 0100.0 Alarm (all channels) All levels alarm OFF, Relay OFF Engineering unit (all channels) Chart feed speed Time (1)20mm/h (2)20mm/h 2000/01/01 00:00 Setting other recordings Dot point interval 10(sec) The present time has been set. (Japan standard time) GMT + 09:00 Alarm hysteresis Burnout (all channels) ON(0.5%) OFF Channel offset (all channels) RJC (all channels) Dot printing color (Ch1 to Ch6) REC (recording) RUN/STOP trigger Channel/Tag printing 0.0 Internal compensation INT Purple(1), Red(2), Green(3), Blue(4), Brown(5), Black(6) INT Ch Zone setting (all channels) 0100(%) Partial compression/expansion OFF (all channels) Tag printing character Blank up to the 7th (all channels) character Alarm printing OFF Logging printing ON Logging printing reference time 00:00 Logging printing interval 6H Logging scale printing OFF Use the "REC" key Comment printing word Blank up to the 16th (1 to 3) character DI function (Ch1 to Ch3) OFF 31 SHINKO TECHNOS CO., LTD. OVERSEAS DIVISION Head Office : 2-5-1, Senbahigashi, Minoo, Osaka, Japan URL: http://www.shinko-technos.co.jp/e/ Tel : +81-72-727-6100 E-mail: overseas@shinko-technos.co.jp Fax: +81-72-727-7006 No. HR7ZE1FLOW 2021.02