Instruction Manual for Autonics models including: PS08 Inductive Proximity Sensor, PS08, Inductive Proximity Sensor, Proximity Sensor, Sensor
AUTONICS PS12-4DN2U (01) PDF MANUAL - MANUAL-HUB.COM
File Info : application/pdf, 1 Pages, 1.68MB
DocumentDocumentDRW160733AC INDUCTIVE PROXIMITY SENSOR PS SERIES INSTRUCTION MANUAL [PS08] [PS12] [PS50] Thank you very much for selecting Autonics products. For your safety, please read the following before using. Safety Considerations Please observe all safety considerations for safe and proper product operation to avoid hazards. symbol represents caution due to special circumstances in which hazards may occur. Warning Failure to follow these instructions may result in serious injury or death. Caution Failure to follow these instructions may result in personal injury or product damage. Warning 1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in fire, personal injury, or economic loss. 2. Do not disassemble or modify the unit. Failure to follow this instruction may result in fire. 3. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in fire. 4. Check 'Connections' before wiring. Failure to follow this instruction may result in fire. Caution 1. Use the unit within the rated specifications. Failure to follow this instruction may result in fire or product damage. 2. Use dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in electric shock or fire. 3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in fire or explosion. 4. Do not supply power without load. Failure to follow this instruction may result in fire or product damage. Ordering Information P S 08 2.5 D N Sensing position No mark Standard type U Upper sensing type Output Power supply Sensing distance Dimension Shape Item N N2 P P2 D Number Number S P NPN Normally Open (N.O.) NPN Normally Closed (N.C.) PNP Normally Open (N.O.) PNP Normally Closed (N.C.) 12-24VDC Sensing distance (unit: mm) A side length of sensing side (unit: mm) Square Inductive proximity sensor Control Output Diagram and Load Operation NPN output type 10k Brown +V Load Black Sensing target Load (Brown-Black) Presence Nothing Operation Return N.O. N.C. Main circuit PNP output type 1 Blue 0V Brown +V 1 Black Output voltage (Black-Blue) Operation Indicator (Red LED) H L ON OFF Sensing target Load (Black-Blue) Presence Nothing Operation Return N.O. N.C. Main circuit 10k Load Output voltage H (Black-Blue) L Blue 0V Operation Indicator (Red LED) ON OFF 1: For PS08 model, there is no zener diode. The above specifications are subject to change and some models may be discontinued without notice. Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage). Specifications Model Sensing distance Hysteresis Standard sensing target Setting distance Power supply (Operating voltage) PS08-2.5DN PS08-2.5DP PS08-2.5DN2 PS08-2.5DP2 PS08-2.5DNU PS08-2.5DPU PS08-2.5DN2U PS08-2.5DP2U 2.5mm Max. 20% of sensing distance 8×8×1mm (Iron) 0 to 1.7mm 12-24VDC (10-30VDC) PS12-4DN PS12-4DP PS12-4DN2 PS12-4DNU PS12-4DPU PS12-4DN2U 4mm Max. 10% of sensing distance 12×12×1mm (Iron) 0 to 2.8mm PS50-30DN PS50-30DN2 PS50-30DP PS50-30DP2 30mm 90×90×1mm (Iron) 0 to 21mm Current consumption Response frequency1 Max. 10mA 1,000Hz 500Hz 50Hz Residual voltage Max. 1.5V Affection by Temp. Max. ±10% for sensing distance at ambient temperature 20 Control output Max. 100mA Max. 200mA Insulation resistance Min. 50M (at 500VDC megger) Dielectric strength 1,500VAC 50/60Hz for 1 minute Vibration 1mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 2 hours Shock 500m/s² (approx. 50G) in X, Y, Z directions for 3 times Indicator Operation indicator: Red LED Environ Ambient temperature -25 to 70, Storage: -30 to 80 -ment Ambient humidity 35 to 95%RH, Storage: 35 to 95%RH Protection circuit Reverse polarity protection, Surge protection circuit, Overcurrent protection Protection structure IP67 (IEC standard) Ø2.5mm, 3-wire, 1m Ø4mm, 3-wire, 2m Ø5mm, 3-wire, 2m Cable2 AWG28, Core diameter: 0.08mm, Number of cores: 19, Insulator diameter: Ø0.9mm AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1.25mm Material Case: Polycarbonate General cable (gray): Polyvinyl chloride (PVC) Case: Heat-resistant ABS General cable (gray): Polyvinyl chloride (PVC) Case: Polybutylene terephthalate General cable (gray): Polyvinyl chloride (PVC) Approval Weight3 Approx. 30g (approx. 16g) Approx. 77g (approx. 62g) Approx. 265g (approx. 220g) 1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance. 2: Do not pull the Ø4mm cable with a tensile strength of 30N or over and the Ø5mm cable with a tensile strength of 50N or over. It may result in fire due to the broken wire. When extending wire, use AWG22 cable or over within 200m. 3: The weight includes packaging. The weight in parentheses in for unit only. Environment resistance is rated at no freezing or condensation. Dimensions PS08 Standard type Ø3.2 18.5 Ø2.5, 1m Upper sensing type 15.5 11.5 Ø3.2 Ø2.5, 1m Bracket (unit: mm) 17.8 0.4 11.3 Ø3.2 5.3 2.3 0.4 8.8 8.1 8 8 Operation indicator (red) 26 8 5.3 23 8 Operation indicator (red) 2 Installing bolts must be a M3×12mm truss bolt and tightening strength should be max. 0.49Nm. If installing this unit not as this method, it may cause damage to the functions. M3×12mm Mutual-Interference and Influence By Surrounding Metals Mutual-interference When plural proximity sensors are mounted in a close row, malfunction of sensor may be caused due to mutual interference. Therefore, be sure to provide a minimum distance between the two sensors, as below charts. PS08 16 16 (unit: mm) 16 16 (Face to Face) PS12 (Parallel) 24 (Face to Face) PS50 (Parallel) 24 180 130 (Face to Face) (Parallel) (Face to Face) (Parallel) Influence by surrounding metals When sensors are mounted on metallic panel, it must be prevented sensors from being affected by any metallic object except target. Therefore, be sure to provide a minimum distance as a right picture. PS08 PS12 PS50 18 120 12 8 15 15 8 8 5 8 Metal 50 50 12 12 Setting Distance Target Target Moving direction (a) Moving direction Sn:Sensing distance Sa:Setting distance (70% of Sn) (b) Sa Sn 7.4 8 Mounting hole cut-out 11.5 M3×0.5 Tap DP: Min. 8 Ø2.4 DP: Min. 3 PS12 When installing the product, tighten the screw with a tightening torque of 0.49Nm. 45 14.8 15.25 14.5 Ø4, 2m Bracket 29 21 Operation indicator(red) For mounting at cutting hole Sensing distance can be changed by the shape, size or material of the target. Therefore please check the sensing distance like (a), then pass the target within range of setting distance(Sa). Setting distance(Sa)= Sensing distance(Sn) × 70% E.g.)PS50-30DN Setting distance(Sa)= 30mm × 0.7 = 21mm Caution during Use 1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents. 2. 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device. 3. Use the product, after 0.8 sec of supplying power. 4. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise. Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.). In case installing the product near the equipment which generates strong surge (motor, welding machine, etc.), use diode or varistor to remove surge. 5. This unit may be used in the following environments. Indoors (in the environment condition rated in 'Specifications') Altitude max. 2,000m Pollution degree 2 Installation category II 12 6 14.5 0.8 11.9 10.8 12 11.8 2-3.5 PS50 When installing the product, tighten the screw with a tightening torque of 0.98Nm. 55.5 53 45 Ø5, 2m Ø50 45 35 16 10.8 Operation indicator(red) Major Products Photoelectric Sensors Temperature Controllers Fiber Optic Sensors Temperature/Humidity Transducers Door Sensors SSRs/Power Controllers Door Side Sensors Counters Area Sensors Timers Proximity Sensors Panel Meters Pressure Sensors Tachometers/Pulse (Rate) Meters Rotary Encoders Display Units Connectors/Sockets Sensor Controllers Switching Mode Power Supplies Control Switches/Lamps/Buzzers I/O Terminal Blocks & Cables Stepper Motors/Drivers/Motion Controllers Graphic/Logic Panels Field Network Devices Laser Marking System (Fiber, Co, Nd: YAG) Laser Welding/Cutting System http://www.autonics.com HEADQUARTERS: 18, Bansong-ro 513 beon-gil, Haeundae-gu, Busan, South Korea, 48002 TEL: 82-51-519-3232 E-mail: sales@autonics.com DRW160733AC 53 https://manual-hub.com/