User Manual for SmartGen models including: HWP60A Forced Circulation Heater, HWP60A, Forced Circulation Heater, Circulation Heater, Heater
SmartGen HWP60A Engine Heater, Suitable for various engine with (25~50)L displacement. Forced Circulation Heaters.Technical Parameters: Rated Power 6000W Rated Voltage AC 420V Rated Current 8.3A Engine Displacement(L) (25~50) L Thermostat Range Off: (5~99)ºC On: (0~94)ºC Overheating Switch Range Off: (95±3)ºC On: (80±6)ºC Electrical Strength AC 1.5kV 1min Insulating Resistance ≥50MΩ Inlet/Outlet Size 3/4”(Ф19.5mm) Max. Water Pressure 0.5MPa Protection Level IP44 Vibration Resistance (5~8)Hz Amplitude±7.5mm
File Info : application/pdf, 12 Pages, 1.16MB
DocumentDocumentHWP60A/HWP90A FORCED CIRCULATION HEATER USER MANUAL Chinese trademark English trademark SmartGen -- make your generator smart SmartGen Technology Co., Ltd. No.28 Jinsuo Road, Zhengzhou, Henan Province, China Tel: +86-371-67988888/67981888/67992951 +86-371-67981000(overseas) Fax: +86-371-67992952 Web: www.smartgen.com.cn/ www.smartgen.cn/ Email: sales@smartgen.cn All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder. Applications for the copyright holder's written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. SmartGen Technology reserves the right to change the contents of this document without prior notice. Date 2020-12-31 2022-05-10 Version 1.0 1.1 Table 1 Software Version Content Original release. Add HWP90A and operation voltage, change working diagram and add maintenance description. HWP60A/HWP90A Forced Circulation Heater User Manual Page 2 of 12 CONTENT 1. OVERVIEW ................................................................................................................................................ 4 2. PERFORMANCE AND CHARACTERISTICS ............................................................................................. 4 3. SPECIFICATION........................................................................................................................................ 5 4. INSTALLATION INSTRUCTION................................................................................................................ 6 5. OPERATING INSTRUCTIONS................................................................................................................... 7 5.1 PANEL AND BUTTON........................................................................................................................ 7 5.2 DISPLAY DESCRIPTION .................................................................................................................... 7 5.3 PANEL DESCRIPTION ....................................................................................................................... 8 5.4 OPERATION DESCRIPTION .............................................................................................................. 8 6. USE AND MAINTENANCE........................................................................................................................ 9 6.1 VENT VALVE...................................................................................................................................... 9 6.2 WATER DRAIN VALVE....................................................................................................................... 9 7. CONNECTIONS.......................................................................................................................................11 8. CASE AND DIMENSIONS ....................................................................................................................... 12 HWP60A/HWP90A Forced Circulation Heater User Manual Page 3 of 12 1. OVERVIEW HWP60A/HWP90A forced circulation engine water heater is composed of 3 parts (control section, water pump and water heater). If the outside temperature is lower than 4ºC, engine coolant and lubricant may condense into solid state and lose their lubricating and cooling properties during cranking, which can damage the engine. Thus engine heater should be installed to ensure normal starting and running of the engine when the outside temperature is lower than 4ºC. HWP60A forced circulation engine water heater combines the following features: cast stainless steel inner pipes and end closure with high corrosion resistance; heating and overheat light indicators; user-defined thermostat set point; dry heating and overheat protection. This product is suitable for various engine with (25~75)L displacement. Please login our company's official website (www.smartgen.com.cn) to select heaters. 2. PERFORMANCE AND CHARACTERISTICS ----The circulating water pump adopts special customized pump with stainless steel pump head; ----Microprocessor design of control section and PT100 temperature sampling. Coolant temperature can be set via the control panel. Four digital LED display, current coolant temperature and all kinds of set point temperature can be displayed clearly; ----Dry heating and overheat protection due to the inner overheating temperature detect switch; ----Separately control of water pump and water heater: power on the water pump and water heater synchronously, once the set temperature has reached, water heater will be powered off firstly, after 60s, following is water pump. The goal is to prevent heat concentration and significantly prolong water pump lifetime; ----Manually test the water heater and water pump are normal or not via panel button; ----Fine cast aluminum enclosure; ----Stainless steel inner pipes and sealed end closure; ----There is a water drain valve with seal ring on the bottom of the heater so as to be used when needed; ----There is one-way inlet valve on the water inlet; ----This product can work normally at -40ºC temperature. HWP60A/HWP90A Forced Circulation Heater User Manual Page 4 of 12 3. SPECIFICATION Table 2 Parameters Specification Item HWP60A Rated Power 6000W Rated Voltage AC 420V Operation Voltage AC (378~440)V Rated Current 8.3A Phase Three Phase Engine Displacement (25~50)L Thermostat Range Off: (5~99)ºC On: (0~94)ºC Default Thermostat Range Off: (40±2)ºC On: (25±2)ºC Overheating Range Thermostat Off: (95±3)ºC On: (80±6)ºC Insulating Resistance 50M Electrical Strength AC 1.5kV 1min Inlet/Outlet Size 3/4(19.5mm) Max. Water Pressure 0.5MPa Pump Flow Velocity 40L/min (1.5m of lift) Protection Level IP44 Vibration Resistance (5~8)Hz Amplitude±7.5mm Triaxial (8~500)Hz a=2g Triaxial Shock Resistance Half-sine Wave; apeak=50g; Triaxial Working Temperature -40ºC~+70ºC Storage Temperature -40ºC~+80ºC Case Dimensions 504mm×255mm×426mm Weight 15kg HWP90A 9000W 12.5A (50~75)L HWP60A/HWP90A Forced Circulation Heater User Manual Page 5 of 12 4. INSTALLATION INSTRUCTION Please install the heater vertically according to the diagram before use. Pay attention to the direction of heater inlet and outlet, and ensure that the heater position is below the lowest water lever of the engine and that all the air is exhausted out of the heater and it is topped off with coolant. Fig.1 Working Diagram Fig.2 Installation Diagram HWP60A/HWP90A Forced Circulation Heater User Manual Page 6 of 12 Fig.3 Incorrect Pipe Connection Methods NOTE: If there is a W-shaped bend or reverse U-shaped bend during pipe connection, the air accumulated in the pipe cannot be discharged normally, resulting in the liquid cannot be circulated properly. The air dissolved in the liquid will be precipitated during heating and retained in the bend, so on the condition of unsmoothed pipeline, even if by the manual exhaust, it will repeat in the next heating process of air collection. To ensure that the smooth liquid circulation, the hosepipe with an inner diameter of more than 20mm and pipe joints with an inner diameter of more than 15mm should be selected. 5. OPERATING INSTRUCTIONS 5.1 PANEL AND BUTTON Button Definition Table 3 Panel Display and Buttons Description Test Pressing this button to test-run the machine. Lamp Test All indicators will be illuminated when the button is pressed. Set Pressing this button to set the temperature value. Turn Page Pressing this button to scroll pages of the LED Nixie Tube and adjust the value. 5.2 DISPLAY DESCRIPTION The heater is heating on when the "Heating" indicator is illuminated while the Thermostat is open and the heater stops heating when the "Overheat" indicator is flashing. Temp. Display: OFF Temp. Display: ON Temp. Display: Current Temp. Alarm: Sensor Abnormal HWP60A/HWP90A Forced Circulation Heater User Manual Page 7 of 12 5.3 PANEL DESCRIPTION 5.4 OPERATION DESCRIPTION Fig.4 Operation Panel Drawing Turn Page( ) Using this button you can scroll pages of the LED Nixie Tube and adjust the value. Test( ) If the water temperature has exceeded the preset "ON" temperature, pressing this button will test-run the heater, after 3s, it turns into Auto mode automatically. Lamp Test( ) All indicators will be illuminated when the button is pressed. Set( ) Pressing this button will enter into setting interface, as shown: (Letter "H" means that it is the preset "OFF" temperature, here we take 40ºC as example)the first digital is flashing and you can adjust it by pressing button. Then press button, the second digital will flash and the adjust way is same as the first digital. Press , as shown: (Letter "L" means that it is the preset "ON" temperature, here we take 25ºC as example)the first digital is flashing and you can adjust it by pressing button. Then press button, the second digital will flash and the adjusting way is same as the first digital. After doing these, press button, the LED will back the current temperature. All the adjustment should be saved and not lost even when power is off. HWP60A/HWP90A Forced Circulation Heater User Manual Page 8 of 12 6. USE AND MAINTENANCE 6.1 VENT VALVE Before starting the machine, ensure that all the air is exhausted out of the heater and it is topped off with coolant, and make sure that the pump is full of water by using vent valve. 6.2 WATER DRAIN VALVE Fig.5 Vent Valve Indicating Diagram If water is used, please drain it off when ambient temperature is lower than 0ºC. Otherwise, the remaining water will freeze, resulting in heater break. Using tap water or river water will scale the surface of heating pipe and shorten the using life of the heater. Corresponding antifreeze is strongly recommended. Earth line must be soundly connected to earth. Drain valve: Can be opened or closed using hexagonal tools. Unit: mm Fig.6 Water Drain Valve Common Faults and Solutions: 1. Overheat protection: a. Check the valve to assure whether it is opened and whether the heater is full of water; b. Check whether the hosepipe has an obvious W-shaped or reverse U-shaped trend, and whether there is an obvious hot and cold alternating area. Solutions: Shorten the hosepipe length and optimize the hosepipe trend. 2. High water outlet temperature: under normal circumstances, the outlet temperature is about 70ºC. It occurs when the hosepipe is too long, both the inner diameter of the hosepipe and the inner diameter of the fitting joints are too small, as well as the water flow is not smooth so that the heat cannot be HWP60A/HWP90A Forced Circulation Heater User Manual Page 9 of 12 transferred properly. Solutions: Shorten the hosepipe length, using the hose with an inner diameter of more than 20mm, and the connectors with an inner diameter of more than 15mm. 3. Unable to reach the preheating temperature: a. The heater power is not enough; b. The cable of the power supply is too long and result in dividing resistance of the cable. Solutions: 1. Replace the heater whose power matches the engine; 2. Shorten the power cable as possible and increase the cable diameter. HWP60A/HWP90A Forced Circulation Heater User Manual Page 10 of 12 7. CONNECTIONS Fig.7 Schematic Diagram Use 4mm2 power cable for tie-in. Earth line must be soundly connected to earth. HWP60A/HWP90A Forced Circulation Heater User Manual Page 11 of 12 8. CASE AND DIMENSIONS unit: mm Fig.8 Overall Dimensions NOTE: All the inlets/outlets connectors are Pagoda-shape. _________________________________ HWP60A/HWP90A Forced Circulation Heater User Manual Page 12 of 12