SV201 PIRCAM Detector
General Introduction
General Introduction
The SV201 PIRCAM is a detector combining Passive Infra-Red (PIR) sensor and image sensor to capture images when motion is detected. This is used for video verification at an alarm monitoring center to reduce false alarms events triggered from the protected site. The device also supports on-demand photo capture by the controller, as requested by a user through the App, or as an action following an alarm condition or perhaps as part of a home automation scenes. Its great compatibility with our U-Net family security products makes it suitable for smart home cloud based platforms such as VIAS.
Main Features:
- Captures multiple photos when PIR trigger
- On-demand photo capture
- IR LED for low light conditions
- Pet immune up to 27kgs
- PIR temperature compensation
- Accelerometer to detect tamper when ceiling mount
- Optional DC power
Product Overview
Components:
- A. LED indicator [indicator light]
- B. PIR sensor [motion sensor]
- C. Camera [camera lens]
- D. IR LED [infrared light emitter]
- E. Back cover [device housing]
- F. Mounting hole for bracket screw [hole for mounting hardware]
- G. Back cover hook [latch for securing cover]
Back cover removed:
- H. Binding button [pairing button]
- I. LED jumper [jumper for LED control]
- J. Back cover tamper switch [switch for detecting cover removal]
- K. External DC power [port for power adapter]
- L. Test point, factory use only [diagnostic point]
- M. Battery slot [compartment for batteries]
Accessories
- 3M wall mount tapes
- Screw packs
Pairing to controller
- Open the back cover by pressing the back cover hook “G” (see Product Overview).
- Insert 3 pcs of CR123A batteries. Note the polarity of the batteries before inserting into the battery slots. Once inserted, do not put back the back cover yet.
- Login to the VIAS app, and select which controller to pair, which will then display the controller's main dashboard page.
- Go to Menu (3-bar) > System Setup > Add device > choose SV201.
- Follow the instruction on the APP to locate the Binding button “H” (see Product Overview) on the detector. When prompted, press and hold this button for more than 3 seconds until the blue “V” LED flashes moderately, then release the button.
- The LED should stop blinking indicating the pairing process is complete.
- Follow the on screen instruction to set up the detector.
IMPORTANT: To store photos taken by PIRCAM, the VIAS controller must be fitted with storage hardware for video, either an SSD or at least an SD card. Please refer to the user manual for the VIAS controller for details.
Mounting
Choosing a location
The detector is suitable for mounting indoor in dry interior locations only. When considering a location for the detector the following points should be considered:
- Do not locate the detector facing a window or where it is exposed to or facing direct sunlight. PIR detectors are not suitable for use in conservatories.
- Do not locate the detector where it is exposed to ventilators.
- Do not locate the detector directly above a heat source, (e.g. fire, radiator, boiler, etc).
- Do not locate the detector in a position where it is subject to excessive vibration.
Where possible, mount the detector in the corner of the room so that the logical path of an intruder would cut across the detection zone. PIR detectors respond more effectively to movement across the detection area than to movement directly towards the sensor.
Detection Range Visuals:
Side View: Detection height up to 2.2m, with a minimum detection height of 1m.
Top View: Detection range up to 12m, with a field of view of 110° (at 2.1m height) and 8m with a field of view of 120°.
This detector is designed to be pet immune, meaning small pets or animals will not trigger the detector and cause false alarms. For pet immunity to be effective the pet's height and weight must not exceed 100cm/27kg respectively to avoid triggering the detector. If the detector is installed below the recommended height, then the animals will move in the high sensitivity zone that may raise an alarm.
Wall mounting by tape
Stick the 3M tapes on surface "F" (see Product Overview) then align SV201 onto the wall corner.
Recommended Position
The recommended position for the motion sensor is on the wall of a room mounted at a height of 2.1~2.3 meters. At this height, the detector will optimize the detection range of up to 12 meters with a field of 110° and 8 meters with a field of 120°.
Mounting Methods
Wall mounting by screw
- Using the back plate as a template, mark the positions of the fixing holes, according to whether the unit is mounted in a corner or against a flat wall.
- Drill out the required mounting holes (diameter:5mm, depth:25mm) in the rear cover.
- Secure the back plate with the screws provided. (Do not over-tighten the fixing screws as this may distort or damage the back plate.)
- Align the top of the detector to clip it onto the top edge of the back plate. Then push the bottom edge of the detector until it locks into place.
Flat mount and Corner mount options are available.
Ceiling mounting by bracket
The screw hole on the back cover is compatible with 1/4-20 UNC standard used on many tripods and surveillance camera brackets. A camera bracket [bracket not included] can be used.
When using a camera bracket, the built-in accelerometer can be enabled to detect tamper by displacement. Refer to the Advanced Settings section.
Walk Test
Once mounted, the coverage area of the PIR can be tested using the Walk Test function of the VIAS app.
- From the App, long press on the PIRCAM icon to enter the Sensor Information page.
- Locate the “START WALK TEST” button at the bottom and press to start.
Note: Often the PIR may not be ready because it has been triggered recently. Stand away from the PIR's range and wait until the timer counter to expire before pressing again.
- Once Walk Test has started, walk around detection area and observe the LED on the PIRCAM. Whenever motion is detected the LED will blink red, after which it will turn off for 2 secs before detecting the next motion.
- Press STOP button when Walk Test is complete.
Note: When powered on, the PIR on the PIRCAM needs one minute to warm up before it can begin proper operation. This is indicated by a red LED blinking once every 3 seconds. Once the PIR is ready the red LED will turn on for about 5 seconds to commence operation.
Camera Operation
Manual capture
The Pircam can capture an image simply by pressing the yellow camera icon next to its icon. Captured images are then sent wirelessly over to the controller, this may take some time depending on the number of images and image size. As a reference, a single picture of VGA size may take approximately 20 seconds.
Image capture stages:
- Ready
- Capturing images ...
- Sending images ...
To view images, long press on the icon of the PIRCAM to enter the Sensor information page. Tap the Pictures icon to see image thumbnails.
Alarm Capture
When the system is Armed, the Pircam will capture images when its PIR detects motion. Images captured from alarm are shown along with alarm logs on the Notification page of the app.
Note: When the system is Disarmed, no images will be captured when PIR is triggered. This is to preserve battery life and to reduce wireless traffic on the system.
Advanced Settings
Long press on the Pircam icon on the device list to enter its Sensor Information page. Tap on the gear-shaped icon ⚙️ to enter the Advanced settings page.
- Enable Camera: Turns on/off the camera function of the PIRCAM. When turned off, the yellow camera icon disappears and the Pircam will behave like a normal PIR sensor.
- Enable PIR during Disarm: By default the PIR sensor on the Pircam is turned off when the system is Disarmed. In some cases the user would like to keep the PIR sensor on, such as for home automation use.
- Tamper detection for ceiling mount: This turns on/off the vibration sensor within the Pircam, to detect displacement when mounted using a bracket from the ceiling.
- PIR Sensitivity: Choose from High, Medium or Low.
IMAGE CAPTURE AT PIR TRIGGER for Alarm capture
- Resolution: QVGA (320x240), VGA (640x280)
- Quality: Capture quality Low or High. Setting High quality will result in longer period for receiving pictures by the Gateway.
- Auto Lighting: Set to Disable will turn off the IR LED on the Pircam, setting to Auto will turn on the IR LED under low light conditions.
- Capture Quantity: Number of images to capture each time PIR is triggered. When set to VGA and High Quality, only a maximum of 3 images are allowed.
- Lock camera after: Turns off the camera after consecutive PIR triggers. This serves to preserve battery life and to avoid unnecessary transmission of images from the same repeated triggers. This is similar to Zone Lock where the siren is turned off after repeated number of triggers.
- Lock period: Sets the lock period for disabling the camera. The camera will resume normal operation after this lock period expires.
IMAGE CAPTURE FROM APP
This section sets the parameters for on-demand capture by the controller, whether for manual capture, or as capture action following an alarm or home automation event. The parameters in this section are similar to PIR trigger parameters above.
Status Icons
Icon | Description |
---|---|
A | Ready to capture image |
B | Capturing image |
C | PIR Trigger alert |
D | Sending images |
E | Accelerometer Tamper |
F | Cover removed Tamper |
G | PIR Trigger alert |
H | Battery level |
I | RF signal level |
Maintenance
Low Battery: The detector will report to the controller when its battery becomes low. When this happens, the camera function will be disabled to conserve battery life. Promptly replace with new batteries to resume operation.
Lens cleaning: The camera lens is protected with a lens shield. To clean, simply wipe with a clean dry cloth or tissue.
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please contact your original retailer or nearest service center if the below solutions cannot solve your problem.
Symptom | Possible Cause | Recommendation |
---|---|---|
LED does not turn on | No power | Check if batteries are inserted correctly or replace with new ones. |
Camera is capturing but no images appears in App | Jumper for LED is not inserted (see item "I" in Product Overview). | Insert the LED jumper connector. |
No storage in Control Panel | Insert SD card or SSD storage at Control Panel. | |
Camera does not capture when its PIR triggers | Low battery | Replace with new batteries. |
Camera is locked. See Advanced Settings, item "Lock camera after" | Wait for time out period, or Disarm and then Arm again. | |
Takes a long time to send images over | PIRCAM located too far from Control Panel | Relocate the PIRCAM nearer, or add a Repeater. |
LED Indicators
Blue LED: Indicator for RF and Low Battery
LED behavior | Description |
---|---|
Blink slowly | Pairing: Device not paired, still in factory mode |
Blink quickly for 30 secs | Pairing: Device is waiting to pair |
Flash rapidly 3 times | Pairing: Device fail to pair |
On about 5 secs | Sending Images after image capture |
Blink once after PIR triggered | Low battery |
Blink once every 5 secs | RF test mode, per EN50131 |
Red LED: Indicator for PIR and Camera
LED behavior | Description |
---|---|
Blink every 3 secs for 60 secs | PIR warm up |
Blink once | PIR trigger |
Flash rapidly multiple times | Image capture |
Reset to Factory Settings
- Press and hold the Binding button for 3 or more seconds, and the detector's LED will start to flash. Release the button.
- Press and hold the Binding button again, this time for longer than 6 seconds until the LED turns off. The device is now reset back to factory mode.
Specifications
Operating temperature range | -10°C to 55°C |
Operating humidity | 85% RH at 30°C |
Mounting height | 2.1 ~ 2.3m |
PIR Detection Coverage | Up to 12m x 110° (at 2.1m height & below 25°C) |
Pet Immunity | Weight-Up to 27 kg, Height- Up to 100 cm |
Sensitivity adjustment | High / Med / Low |
Warm Up Time | About 1 minute |
Camera Image resolution | 640 x 480, 320 x 240 |
Camera angle (deg) | 96 (H), 71(V), 126 (D) |
Night Vision | IR-LED, up to 10m |
Auto Day/Night | Color / Black& White |
Images at alarm | Selectable 1-5 images, 2 secs interval |
Image encryption | JPEG |
Battery type | CR123A 3.0V *3 (external Dc power) |
Battery life | Up to 4 years |
External DC input | 12V, 1A |
RF Frequency | 868 MHz (EU), 923 MHz (US) |
RF transmission range | Up to 800m (Open space) |
Tamper detection | Front cover, removal, ceiling mount |
Security Grade 2, Environmental Class II | EN50131-1:2006/A1:2009/A2:2017/A3:2020, EN50131-2-2:2017, EN50131-5-3:2017, EN50131-6:2017 |
** Specifications are subject to change without prior notice.
[CE FC logo]
Important Information and Statements
Disposal Warning
⚠️ WARNING: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal free of charge.
Battery Caution
❗ CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Federal Communication Commission Interference Statement
FCC warning: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- - Reorient or relocate the receiving antenna.
- - Increase the separation between the equipment and receiver.
- - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- - Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Industry Canada statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
This equipment complies with IC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body."
Ce matériel est conforme aux limites d'exposition aux rayonnements rf de ic énoncés dans un autre environnement. Ce matériel doit être installé et exploité à une distance minimale de 20 cm entre le radiateur et votre corps.