User Manual for CUTTING EDGE POWER models including: CEP300, Flush Mount Solar Charge Controller for Lead Acid, CEP300 Flush Mount Solar Charge Controller for Lead Acid
Flush Mount Solar Charge Controller CEP300 for Lead Acid, SLA/AGM, and Lithium Batteries | Cutting Edge Power
File Info : application/pdf, 2 Pages, 2.09MB
DocumentDocumentCEP300 . OPERATION & SETTINGS PAGES l)Button Setting Info T here are 2 buttons on the controller for operations and settings. Check the below diagram for setting details: BUTTON SETTING STATUS « In Setting Not in Setting (+/-) In Setting Not in Setting PRESS Long press Short press Long press Short press Long press Short press Long press Short press FUNCTION Enter page not for settings Enter next page for settings Enter page for settings Enter next page not for settings No function To adjust parameter No function No function Remarks: "In Setting" means the user is in process of setting parameters. 2) Information Pages: ·-:---L 1 · - - : . f:Mn1Type p,-,,l><Jtton(oLiillttor)'l'ypo) 12 1 -- - - 8 -1 · Syst.emVolt.age I I·· 1 II - Setting ----, ::1 · ChargeVottage I.._, IYY' '-""--'" -----,..,....,...., ..;! :ion- lb·-rTyJ>O<;ott;ogl ::::: BATTERY TYPE & PARAMETER SETTINGS · 1) Battery Type Setting · · :FL-d----: =? :.SeaE$.L : I ___________ ij :.ea$. : :.ea$. : · L I 'E' · U L I ¢== I ! ___________ ! ___________ DISPLAY FLD SEL GEL LI BATTERY TYPE Flooded Battery Sealed/AGM Battery Gel Battery Lithium Battery REMARKS Battery system voltage auto recognition; parameters default set. System voltage, charge/discharge parameters adjustable. 2) Battery System Voltage Setting (only for lithium battery) · V 3) Charge Voltage Setting (only for lithium battery) ··CIILY f,uI.uI v CONTROLLER ERROR INFO & RECOVERY Due to a variety of potential issues, the controller may sometimes display an error code on the LCD screen. If this happens please refer to the below diagram: CODE EOO EOl E02 E06 EOB ElO EB E14 ERROR No Error Over-discharged Over voltage Device over heating Input over load PV over voltage PV anti-connection Battery anti-connection ANALYSIS - The battery has been discharged below normal ranges. The battery voltage exceeds the normal range. Charge shuts down due to high temperature inside the controller The solar (PV) input power exceeds the rated value The solar (PV) input voltage is too high. Solar (PV) module +polarity reverse-connection Battery+- polarity reverse-connection SOLUTION (Recovery) - Recovered once battery voltage returns to normal range. An alternate charge source may be required depending on depth of discharge Recovered after the battery voltage returns to the normal range. It is possible that the battery may be defective. Recovered after temperature returns to the normal range. Recovered after the solar (PV) input power is within the controller ratings. Recovered after the solar (PV) input voltage is within the controller ratings. Correct the + and - solar connection. Correct the + and - battery connection. CONTROLLER SPECIFICATIONS ITEM Model No. System Voltage No-load Loss Max PV Input Voltage Rated Charge Current Max PV Input Power Battery Type Selection Equalize Charge Voltage Boost Charge Voltage FLD 14.8V (12V) / 29.6V (24V) 14.6V (12V) / 29.2V (24V) PARAMETERS 30A Charge Controller 12V/24V 8ma (12V) , 12ma (24V) < 55Voc 30A 450W/12V; 900W/24V SEL GEL 14.6V (12V) / 29.2V (24V) - 14.4V (12V) / 14.2V (12V) / 28.BV (24V) 28.4V (24V) LI - 14.2V (12V) / 28.2V (24V) adjustable Float Charge Voltage 13.8V (12V) / 27.6V (24V) - Boost Charge Recovery Volt 13.2V (12V) / 26.4V (24V) - Over Discharge Recovery Volt. 12.6V (12V) / 25.2V (24V) 11.0V (12V) / 21.0V (24VJ *auto adjusted to over-discharge volt Over Discharge Voltage Light Control Voltage Light Control Delay Time Operation Temperature IP Protection Net Weight 11.1V(12V) / 22.2V(24V) -35"C - +45"C IP32 0.45kg 10.0V (12V) / 20.0V (24V) adjustable Controller Size 170*130*48mm