USB-MeterBus-Adapter-Manual
Morningstar USB MeterBus Adapter Instructions
The USB MeterBus Adapter (model: UMC-1) converts the Morningstar MeterBus RJ11 electrical interface to a standard USB 2.0 interface which allows communication between a PC and applicable Morningstar charge controllers or inverters *. The UMC-1 is required for programming custom charging set-points and logging data using Morningstar's MSView PC software. The UMC-1 is also required for communication with any 3rd party hardware that supports MODBUSTM communication.
* Morningstar controllers or inverters that only have a MeterBus connection , i.e. no serial or other communications port. This includes the Sunsaver MPPT, SunSaver DUO, and Suresine products.

Wiring Diagram
PC or 3rd party hardware

IMPORTANT! No software driver included.
Download the latest USB driver on our website:
www.morningstarcorp.com/support

Morningstar Charge Controller or Inverter

UMC-1

USB B to USB A cable (1 meter, included)

Notes: 1) 4-conductor or 6-conductor telephone cord is acceptable 2) The UMC-1 is fully opto-isolated. USB electrical ground is NOT the same ground as RJ-11 / controller.

LED Indication
OFF: No connection to controller

GREEN: Connection OK

RJ-11 telephone cable (1 meter, included)
ORANGE: Communication activity

Modbus documentation including register locations, scaling, and
definitions can be found on Morningstar's website at: www.morningstarcorp.com

MS-001373 04/28/2015DS

