ELPRO ECOLOG-PRO 2PTR & 1THR Radio Modules Operation Manual

System Overview

The ECOLOG-PRO measurement and communication modules described in this document are used for temperature monitoring. The measured values are transmitted to a monitoring software, which stores and analyzes the data, provides alerts if alarm limits are violated, and generates reports. The system provides superior visibility and transparency in meeting GxP requirements. The sensor-based monitoring software is easily accessible via a web browser and is also used to configure the measurement modules and sensors.

The following pages contain key features and technical specifications of ECOLOG-PRO 2PTR and ECOLOG-PRO 1THR. In addition, you will find information on how to connect the modules.

For detailed software and connection support, please visit:

The system comprises:

  • Monitoring Software
  • Communication Module (RBR)
  • Measurement Modules (2PTR, 1THR)

Measurement Module ECOLOG-PRO 2PTR

Functional Characteristics

ECOLOG-PRO 2PTR is a measurement module with two external temperature sensors. Communication from this module with the ECOLOG-PRO RBR is via radio signal.

Specifications
Power supply3 AA Alkaline batteries
Battery life14 months (provided that the module's radio connection is stable and that the defined temperature range is maintained)
Case / DimensionsABS plastic material; 137 mm (5.39 inch) x 70 mm (2.76 inch) x 57 mm (2.24 inch)
Measurement range-200 °C to +200 °C
Measurement resolution0.1 °C
Measurement accuracy±0.2 °C
Logging and communication interval1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software. NOTE: Logging interval will impact battery life.
Channels2 independent temperature channels with separately connected sensors
Probe typeExternal 4-wire Pt100 probe
Probe connectionStandard probe: Pt100 temperature sensor, 3m cable, no shielding. Extension: maximum 17 meters, no shielding.
Memory capacity43,000 measurement values
Environmental storage temperature / humidity-10 °C to +50 °C; 10 %RH to 90 %RH, non-condensing
Environmental operating temperature / humidity0 °C to +40 °C; 10 %RH to 90 %RH, non-condensing
Operating altitudeThis device must not be used at altitudes higher than 2000 meters above sea level.
ID number"Q" followed by a 6-digit number; the ID number is used to identify the module in the software.
Radio connection to communication moduleAvailable in two versions: 868 MHz (Europe) or 915 MHz (US). Note: Only the supplied antenna may be used.

LED Indicators (Link/Data)

Left LED (Link)

  • Red flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active but is not connected to a communication module ECOLOG-PRO RBR.
  • Yellow flashing light (1s flashing interval): ECOLOG-PRO 2PTR is currently receiving its registration information. Please wait for green light.
  • Green flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active and connected to a communication module ECOLOG-PRO RBR. Everything is OK.

Right LED (Data)

  • Yellow flashing light (10s flashing interval): ECOLOG-PRO 2PTR is active but registration was not successful and has to be started again by pressing the pairing button shorty (for less than 1s).
  • Red flashing light (10s flashing interval): Measurement on one or both channels has started. There are one or more failures in measurement.
  • Green flashing light (10s flashing interval): Measurement on one or both channels has started. Everything is OK.

How to Connect

When using the software ELPRO Cloud:

  1. Remove the screw on the front and open the measurement module's cover.
  2. Insert the three AA batteries.
  3. Bring the measurement module ECOLOG-PRO 2PTR in close proximity (approximately 10 cm) to an ECOLOG-PRO RBR connected to the monitoring software.
  4. Press and hold the "Connect" button inside the measurement module for more than 3 seconds. The left LED will blink red 3 times.
  5. Wait until the left LED starts flashing red (once per second).
  6. A successful connection will be indicated by the left LED illuminating in green for 10 seconds. Afterwards, the left LED will be flashing green every 10 seconds.
  7. Close the communication module's cover and tighten the screw. Place the module in its intended location (e.g. storage room, next to your ultra-freezer or cryo container, etc.).

When using the software elproMONITOR: You can connect the sensor to the communication module before or after parameterization in elproMONITOR. The monitoring software suggests already connected measuring modules or saves the data of parameterized measuring modules until the connection is made.

Measurement Module ECOLOG-PRO 1THR

Functional Characteristics

ECOLOG-PRO 1THR is a measurement module with one external combination probe for temperature and relative humidity. Communication from this module with the ECOLOG-PRO RBR is via radio signal.

Specifications
Power supply3 AA Alkaline batteries
Battery life14 months (provided that the module's radio connection is stable and that the defined temperature range is maintained)
Case / DimensionsABS plastic material; 137 mm (5.39 inch) x 70 mm (2.76 inch) x 57 mm (2.24 inch)
Measurement range and accuracySensor data (page 11)
Measurement resolution0.1 °C
Logging and communication interval1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software. NOTE: Logging interval will impact battery life.
Channels2 channels (1x temperature / 1x humidity)
Probe typeDigital probe
Probe connectionDigital 3-PIN combination probe. Extension: maximum 10 meter cable, no shielding.
Memory capacity43,000 measurement values
Environmental storage temperature / humidity-10 °C to +50 °C; 10 %RH to 90 %RH, non-condensing
Environmental operating temperature / humidity0 °C to +40 °C; 10 %RH to 90 %RH, non-condensing
Operating altitudeThis device must not be used at altitudes higher than 2000 meters above sea level.
ID number"R" followed by a 6-digit number; the ID number is used to identify the module in the software.
Radio connection to communication moduleAvailable in two versions: 868 MHz (Europe) or 915 MHz (US). Note: Only the supplied antenna may be used.

LED Indicators (Link/Data)

Left LED (Link)

  • Red flashing light (10s flashing interval): ECOLOG-PRO 1THR is active but is not connected to a communication module ECOLOG-PRO RBR.
  • Yellow flashing light (1s flashing interval): ECOLOG-PRO 1THR is currently receiving its registration information. Please wait for green light.
  • Green flashing light (10s flashing interval): ECOLOG-PRO 1THR is active and connected to a communication module ECOLOG-PRO RBR. Everything is OK.

Right LED (Data)

  • Yellow flashing light (10s flashing interval): ECOLOG-PRO 1THR is active but registration was not successful and must be restarted by pressing the pairing button shorty (for less than 1s).
  • Red flashing light (10s flashing interval): Measurement on one or both channels has started. There are one or more failures in measurement.
  • Green flashing light (10s flashing interval): Measurement on one or both channels has started. Everything is OK.

How to Connect

When using the software ELPRO Cloud:

  1. Remove the screw on the front and open the measurement module's cover.
  2. Insert the three AA batteries.
  3. Bring the measurement module ECOLOG-PRO 1THR in close proximity (approximately 10 cm) to an ECOLOG-PRO RBR connected to the monitoring software.
  4. Press and hold the "Connect" button inside the measurement module for more than 3 seconds. The left LED will blink red 3 times.
  5. Wait until the left LED starts flashing red (once per second).
  6. A successful connection will be indicated by the left LED illuminating in green for 10 seconds. Afterwards, the left LED will be flashing green every 10 seconds.
  7. Close the communication module's cover and tighten the screw. Place the module in its intended location (e.g. laboratory, storage room, etc.).

When using the software elproMONITOR: You can connect the sensor to the communication module before or after parameterization in elproMONITOR. The monitoring software suggests already connected measuring modules or saves the data of parameterized measuring modules until the connection is made.

Sensor Data

Part No. 802209: Temperature & humidity sensor, capacitive

This sensor is designed to monitor storage rooms, laboratories or for general room-climate monitoring.

Specifications
Measurement rangeHumidity: 20 %RH to 80 %RH
Temperature: -20 °C to 80 °C
Humidity accuracy15.0 °C to 30.0 °C: ±2.0 %RH
Temperature accuracy65.0 °C to 80.0 °C: ±0.5 °C
0.0 °C to 64.9 °C: ±0.3 °C
-20.0 °C to -0.1 °C: ±0.5 °C
Drift Humidity sensorTypically 3 %RH / year

Part No. 802363: Temperature & humidity sensor, electrolytic

This sensor is designed for:

  • Environments with aggressive gases at high temperature and air humidity (stability chambers, incubators)
  • Low-temperature environments (refrigerator)
  • High-precision measurements of ±0.5 %RH
Specifications
Measurement rangeHumidity: 0 %RH to 100 %RH
Temperature: -20 °C to 80 °C
Humidity accuracy50.0 °C to 80.0 °C: ±2.5 %RH
30.0 °C to 49.9 °C: ±0.8 %RH
15.0 °C to 29.9 °C: ±0.4 %RH
0.0 °C to 14.9 °C: ±0.8 %RH
-20.0 °C to -0.1 °C: ±2.5 %RH
Temperature accuracy65.0 °C to 80.0 °C: ±0.2 °C
0.0 °C to 64.9 °C: ±0.1 °C
-20.0 °C to -0.1 °C: ±0.2 °C
Drift Humidity sensorTypically < 1 %RH / year

Disposal

a) Product

Electronic devices are recyclable and do not belong in the household waste. Dispose of the product at the end of its service life in accordance with applicable laws. Remove any batteries and dispose of them separately from the product.

b) Batteries

You are legally obliged to dispose of all used batteries according to applicable laws; disposal via household waste is prohibited. Batteries categorized as containing hazardous material are marked with the adjacent symbol, under which is printed the chemical symbol for the heavy metal (Cd = cadmium, Hg = mercury, Pb = lead) used. You can dispose of used batteries at collection points in your local community. Please help protect our environment and dispose of batteries properly.

Declaration of Conformity

ELPRO-BUCHS AG declares that the radio equipment type ECOLOG-PRO 2PTR 868 MHz is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available in chapter 5 of this document or at the following internet address: https://www.elpro.com/fileadmin/Docs/Quality_Documents/ECOLOG-PRO_2PTR_DOC_Conformity_1000279V01.pdf.

ELPRO-BUCHS AG declares that the radio equipment type ECOLOG-PRO 1THR 868 MHz is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available in chapter 5 of this document or at the following internet address: https://www.elpro.com/fileadmin/Docs/Quality_Documents/ECOLOG-PRO_1THR_DOC_Conformity_1000281V01.pdf.

Above mentioned products operate in the 863-870MHz band with a maximum radiated output power of +11.6dBm.

ECOLOG-PRO 2PTR 915 MHz and ECOLOG-PRO 1THR 915 MHz comply with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Above mentioned devices operate in the 902-928MHz band with a maximum radiated output power of +4dBm.

ECOLOG-PRO 2PTR 915 MHZ contains FCC ID: S9NSPSGRFC, IC: 8976C-SPSGRFC

ECOLOG-PRO 1THR 915 MHz contains FCC-ID: S9NSPSGRFC, IC: 8976C-SPSGRFC

Manufacturer: ELPRO-BUCHS AG, Langäulistrasse 45, 9470 Buchs, Switzerland.

Contact E-Mail: swiss@elpro.com

Models: 2PTR, 1THR, 2PTR Radio Modules, 2PTR, Radio Modules, Modules

File Info : application/pdf, 15 Pages, 1.62MB

PDF preview unavailable. Download the PDF instead.

149825-ecolog-pro-2ptr-elpro-user-manual

References

Microsoft Word 2016

Related Documents

Preview ECOLOG-PRO Radio Modules Operation Manual: 2PTR & 1THR
Comprehensive operation manual for ELPRO ECOLOG-PRO 2PTR and ECOLOG-PRO 1THR radio modules, covering system overview, module specifications, connection instructions, sensor data, and disposal guidelines.
Preview ELPRO LIBERO Gx Operation Manual: Temperature Data Loggers
Comprehensive operation manual for ELPRO LIBERO Gx series temperature data loggers, covering system overview, functionality, modes, accessories, and technical specifications for precise environmental monitoring.
Preview ELPRO LIBERO C PDF Logger & Indicator Operation Manual
Comprehensive operation manual for ELPRO LIBERO C PDF Loggers and Indicators, detailing configuration with liberoCONFIG and SmartStart, safety information, and product specifications for temperature monitoring during transport.
Preview ELPRO LIBERO Cx PDF Logger & Indicator Operation Manual
Comprehensive operation manual for the ELPRO LIBERO Cx PDF data loggers and indicators, detailing setup, configuration with liberoCONFIG, quick start, safety, and SmartStart features for temperature monitoring during transport.
Preview EL-ERTK-A2 ERRTS Field Test Set Operator Manual | ELPRO Technologies
This operator manual provides comprehensive guidance for the ELPRO Technologies EL-ERTK-A2 Field Test Set, designed for testing Event Reporting Radio Telemetry Systems (ERRTS) Field Stations and Store & Forward Repeaters. It covers setup, operation with the Surecom SW-102 VSWR Watt Meter, and the use of ERRTS Ranger Software for data analysis.
Preview Stellenangebot: Senior Product Manager bei ELPRO
ELPRO, ein globaler Schweizer Hersteller von Lösungen für kritische Klimadaten, sucht einen Senior Product Manager (80-100%) für den Standort Buchs SG. Die Rolle umfasst Produktportfolioentwicklung, Markteinführung und Kundenprojektbetreuung. Erforderlich sind technische/betriebswirtschaftliche Studien, Produktmanagementerfahrung und sehr gute Deutsch-/Englischkenntnisse.
Preview LIBERO CE CL CH Operation Manual
Operation manual for ELPRO LIBERO CE, CL, and CH data loggers, detailing their features, functionality, setup, and usage with the LIBERO Cx BLE app.
Preview ELPRO 115S Serial Expansion Modules User Manual
This user manual provides comprehensive information on the ELPRO 115S Serial Expansion Modules, covering installation, configuration, operation, and technical specifications. It details various module types, I/O capabilities, communication protocols (RS232, RS485, Modbus), and hazardous location notices.