PRODUCT MANUAL
Aroma diffuser
01 Specification
Item | Details |
---|---|
Model | A326 |
Size | 117.5*117.5*342mm |
Bottle | 120ml |
Input | 12V-2A |
Working Power | 4W |
Coverage | 100㎡/300m³/10500ft³ |
N.W. | 1.35 kg |
Li-battery | 2200mAh |
Material | Aluminum |
Components include: Bottle, Bottle cap, Power adapter, Manual, Atomizing core, LCD screen, BT Button.
02 Installation step
- Take out the diffuser head.
- Twist off the bottle.
- Fill the bottle with essential oil.
- Put the diffuser head back in the machine.
03 Functional analysis
Key Components:
- Nozzle
- DC connector
- Indicator Light
Button Functions:
- Grade Button: Short press to change intensity grades from 1 → 2 → 3 → 4 → 5 → Custom.
- ON/OFF Button:
- Power on: Short press the ON/OFF button to turn on the machine.
- Power off: Short press the ON/OFF button to turn off the machine.
- Factory Reset: Long press the ON/OFF button for 5 seconds to restore factory settings (levels, programs, password). Note: If the app is connected, the 'Smart' light will flash.
- Ambient light Button: Press to turn the ambient light On/Off. This light can function as a night light and can be controlled independently of the diffuser's operation.
Smart APP Status Lights:
- Bluetooth Paired: The light remains on.
- Data receiving: The light flashes.
- Bluetooth Unpaired: The light is off.
Timer:
Press the Timer button once to switch between timer modes. Default is 24-hour operation. Adjustable modes: 1H, 2H, 4H, 8H, Smart, and 24H.
Power Description:
- Less than 20% battery: [red light]
- More than 20% battery: [green light]
Charging Status (flashing):
- Less than 20% battery: [red light]
- More than 20% battery: [green light]
- 100% charged: [green light] always on.
04 Smart App Instructions
Where to get the app:
Search for "Scent Marketing" in Google Play or the App Store. If the QR code cannot be scanned, use this search method.
Note: Ensure Bluetooth and mobile phone location services are enabled.
App Interface Overview:
The app allows selection between Bluetooth and Wifi versions, and connection to 2G/3G/4G/5G networks.
- Device Selection: Select your device (e.g., A326).
- Login: Enter the factory default password (8888) and press Login. Option to remember password.
- Device Control:
- Change device name and label. Press 'Save' after changes.
- Working Period Setting: Set start and stop working times for the diffuser by scrolling.
- Schedule Management: Add new schedules by pressing '+'. Swipe left to delete a schedule. Use the toggle button to enable/disable schedules.
- Intensity Adjustment: Press '+' or '-' to adjust intensity grades (1-5).
- Custom Intensity: Check the [check-mark] Custom box to set custom 'Spray Time' and 'Pause Time'.
- Calibration: Tap 'Calibrate' to calibrate consumption. It's advised after 10 days of use. Measure remaining oil, enter the volume, and confirm to update consumption and remaining days.
- Password Change: Navigate to 'About' in 'Device Control' to change the password. Enter a new four-digit password and confirm.
- Save Settings: Press the 'Save' button to update all changes.
Factory Reset: If the password is forgotten, hold the On/Off button for 5 seconds to restore factory settings. The default password is 8888.
05 Concentration and consumption
Grade | Work time(s) | Stop time(s) | Battery life (H) | Consumption(g/h) |
---|---|---|---|---|
G1 | 5s | 240s | 200H | 0.05 |
G2 | 15s | 200s | 80H | 0.17 |
G3 | 20s | 160s | 50H | 0.27 |
G4 | 25s | 100s | 29H | 0.49 |
G5 | 25s | 60s | 20H | 0.72 |
Customized | 5-35s | 60-300s | - | - |
Note: Data is for reference only. Oil consumption may vary with essential oil viscosity. For best diffusion, use oils with viscosity below 30mPa.s. Optimal working temperature is 25°C.
06 Regulatory Statements
ISED Statement (Canada)
English: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. The digital apparatus complies with Canadian CAN ICES-3 (B)/NMB-3(B).
This device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS 102 RF exposure. Users can obtain Canadian information on RF exposure and compliance. This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
French: Cet appareil contient des émetteurs/récepteurs exempts de licence qui sont conformes aux RSS exemptés de licence d'Innovation, Sciences et Développement économique Canada. L'exploitation est soumise aux deux conditions suivantes : (1) Cet appareil ne doit pas provoquer d'interférences. (2) Cet appareil doit accepter toute interférence, y compris les interférences susceptibles de provoquer un fonctionnement indésirable de l'appareil. L'appareil numérique est conforme à la norme canadienne CAN ICES-3 (B)/NMB-3(B).
Cet appareil est conforme à l'exemption des limites d'évaluation courante dans la section 2.5 du CNR-102 et conformité avec RSS 102 de l'exposition aux RF. Les utilisateurs peuvent obtenir des données canadiennes sur l'exposition aux champs RF et la conformité. Cet équipement est conforme aux limites d'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps.
FCC Statement (USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
RF Exposure: This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
08 Warning
- Please keep the machine vertical after installation. Tilting or lying flat can cause oil to overflow, and the circuit board may be contaminated, which could affect its efficiency.
- Do not modify, dismantle, or repair the machine arbitrarily. For any malfunction, please contact the relevant technician immediately.
09 Troubleshooting
Breakdown | Solution |
---|---|
No diffuse |
|
Weak diffusion |
|
Oil sprinkle |
|
Oil leakage |
|
Abnormal sound |
|
No display on screen |
|
10 Equipment cleaning
The machine needs cleaning in the following situations:
- When changing to a different kind of essential oil.
- When the atomization volume becomes weak.
Cleaning steps:
- Find a clean bottle and fill it with industrial alcohol.
- Install this bottle into the machine and turn the machine on.
- Let it work for 5-10 minutes.
- Turn off the electric power and finish the cleaning.