2 overview to avoid electrical shocks, remove test leads before opening the case or battery cover. do not operate with battery cover open. − 2 x 1.5v lr6 aa size 430.200


File Info : application/pdf, 16 Pages, 1.47MB

PDF preview unavailable. Download the PDF instead.

120-EN-fc0
USER MANUAL
430.200 AMPCLAMP 200

EN ENGLISH
Manual in your language? Check the back cover

14

13

OVERVIEW
2

TO AVOID ELECTRICAL SHOCKS, REMOVE TEST LEADS BEFORE OPENING
THE CASE OR BATTERY COVER. DO NOT OPERATE WITH BATTERY COVER OPEN.

+ - 2 X 1.5V LR6
AA SIZE

430.200

+

--

15

HOUSING 01 NCV tutpoints 02 Current fork 03 Non-contact voltage indicator 04 LCD display 05 Selector light 06 Rotary function selector 07 Function list with backlight 08 Data hold button / flashlight button 09 Mode button / LCD backlight button 10 MAX / MIN button 11 Flashlight 12 Battery cover 13 Negative / COM connector (black test probe) 14 Positive connector (red test probe) 15 Testprobes

LCD DISPLAY A Alternating voltage / current (AC) B Minus sign C Direct voltage / current (DC) D Auto power off E Auto range mode F Continuity symbol G Diode symbol H Low battery indicator I Unit list J Measured value K Maximum / minimum L Hold symbol M Low Impedance symbol

3

SAFETY

OPERATION

Please read the safety instructions provided as separate booklet with the device.
Do not exceed the maximum allowed input range of any function (e.g. circuit whose voltage exceeds 1.000 Volt).
Set function switch to the appropriate position before measuring. When changing ranges always disconnect the test probes [15] from the circuit under test.
Do not apply voltage to meter when resistance function is selected.
When measuring volts do not switch to current/ resistance modes.
To avoid electrical shocks, disconnect the meter from any circuit. Remove the test probes [15] from the Negative/COM probe connector [13] and the positive probe connector [14]. Then, turn OFF the meter before opening the housing. Do not operate the meter with an open housing.
FIRST TIME USAGE
Remove all protection foils.

AC CURRENT MEASUREMENTS · Turn the rotary function selector [06] to the
position "200A". · Place the current fork [02] around the line
under measurement. The LCD display [04] will show the measured current in the line.

WARNING Ensure that the test probes [15] are disconnected from the meter before making current clamp measurements.

4

VOLTAGE MEASUREMENTS (AC OR DC)
· Insert the black test probe [15] into the Negative/COM probe connector [13] and the red test probe [15] into the positive probe connector [14].
· Turn the rotary function selector [06] to the position "Volt Auto". (The device will automatically select between AC or DC.)
· Connect the test probes [15] in parallel to the circuit under test.
· The Measured Value [J] will show the measured Voltage in the circuit under test. (In case of AC measurements, the device makes a TRUE RMS measurement.)
LOW IMPENDANCE (LOW Z) VOLTAGE MEASUREMENTS
NOTES
Observe all safety precautions when working on live circuits. Do not connect to circuits that exceed 600V AC/DC when the meter is set to Low Z.

Capacitive coupling between wires make it appear that non-powered wires are connected to a real source of voltage.
The Low Z setting places a load on the circuit. which dissipates and greatly reduces ghost voltage.
· Insert the black test probe [15] into the Negative/COM probe connector [13] and the red test probe [15] into the positive probe connector [14].
· Turn the rotary function selector [06] to the position "Volt Low Z".
· Press the MODE button to select between AC or DC voltage. The LCD display [04] shows the AC symbol [A] or DC symbol [C].
· Connect the test probes [15] to the circuit under test. (When measuring DC voltage, touch the red test lead to the positive side of the circuit and the black test lead to the negative side of the circuit.)
· The Measured Value [J] will show the measured Voltage in the circuit under test.

Low Z is used when there is a suspicion of a "ghost" voltage. Ghost voltages are present when non-powered wires are close to wires powered by AC voltage.
5

RESISTANCE MEASUREMENTS
· Insert the black test probe [15] into the Negative/COM probe connector [13] and the red test probe [15] into the positive probe connector [14].
· Turn the rotary function selector [06] to the position "Ohm ­ Diode ­ Continuity ­ Cap".
· Press the MODE button [09] until the Ohm-symbol  is shown in the Unit List [I].
· Connect the test probes [15] to the circuit or component under test.
· The Measured Value [J] will show the measured resistance in the circuit or component under test.
CONTINUITY MEASURES
· Insert the black test probe [15] into the Negative/COM probe connector [13] and the red test probe [15] into the positive probe connector [14].
· Turn the rotary function selector [06] to the position "Ohm ­ Diode ­ Continuity ­ Cap".
· Press the MODE button [09] until the Continuity-symbol [F] is shown.
· Connect the test probes [15] to the circuit or component under test.

· If the measured resistance is at less than 50 Ohm, a tone will sound.
CAPACITANCE MEASUREMENTS
· Insert the black test probe [15] into the Negative/COM probe connector [13] and the red test probe [15] into the positive probe connector [14].
· Turn the rotary function selector [06] to the position "Ohm ­ Diode ­ Continuity ­ Cap".
· Press the MODE button [09] until the Capacity-unit (Micro Farad or Nano Farad) is shown in the Unit List [I].
· Connect the test probes [15] to the component under test.
· The Measured Value [J] will show the measured capacitance in the component under test. The display will indicate the proper decimal point and value. (When measuring very large values of capacitance, it can take several minutes before the final reading stabilizes.)

6

DIODE MEASUREMENTS
· Insert the black test probe [15] into the Negative/COM probe connector [13] and the red test probe [15] into the positive probe connector [14].
· Turn the rotary function selector [06] to the position "Ohm ­ Diode ­ Continuity ­ Cap".
· Press the MODE button [09] until the Diode-symbol is shown in the Unit List [I].
· Connect the test probes [15] to the diode or semiconductor junction under test. Read the Measured Value [J].
· Reverse the test lead polarity by reversing the red and black test probes [15]. Read the Measured Value [J].
· The diode or junction can be evaluated based on your readings of the Measured Value [J]:
> If one reading displays a value [typically 0.400V to 0.900V) and the other reading displays "OL'.', the diode or junction is good.
> If both readings display "OL", the diode or junction is open.
> If both readings are very small or "0", the diode or junction is shorted.

RED PROBE

BLACK PROBE

BLACK PROBE

Forward Test

RED PROBE

Forward Test
NON-CONTACT AC VOLTAGE MEASUREMENTS (NCV) IMPORANT Test the NCV detector first on a known live circuit before use.
· Hold the NCV Test Points [01] very close to the voltage source.
· If voltage is present, the Non-Contact Voltage Indicator [03] will light. NOTE Do not touch the top of the meter when using this function.

7

EXTRA BUTTONS
MODE & LCD BACKLIGHT BUTTON [09]
· Press MODE / LCD Backlight Button [09] to select the unit you need to measure. You will select between OHM, Diode, Continuity, Capacity, Low Z or AC/DC Voltage.
· Hold the MODE / LCD Backlight Button [09] for over 1 second to turn the Selector light [05] on.
· Hold the MODE and LCD Backlight Button [09] again for over 1 second to turn the Selector light [05] off.
MAX/MIN BUTTON [10]
· Press MAX/MIN Button [10] to activate the registration of maximum and minimum values during measurement.
The MAX/MIN modus cannot be activated for a continuity test, diode test, capacitance test or during Non-Contact AC Voltage measurements. · Press the MAX/MIN Button [10] or turn the rota-
ry function selector [06] to switch off the MAX/ MIN Modus.

DATA HOLD & FLASHLIGHT BUTTON [08]
· In case you are measuring in a position where you have no direct view on the LCD Display [04], press the Data Hold / Flashlight button [08]. The HOLD symbol [L] lights up. The device will freeze the measured value on the LCD display [04] and stop measuring continuously.
· After reading the measured value, press the Data Hold / Flashlight button [08] again.
The device will restart measuring continuously and shows the actual measured voltage on the display.
· Hold the Data Hold / Flashlight button [08] for over 1 second to turn the flashlight [11] on.
· Hold the Data Hold & Flashlight button [08] again for over 1 second to turn the flashlight [11] off.

8

AUTOMATIC POWER OFF
In order to save battery life, this device will automatically switch off after approximately 15 minutes.
· To switch the meter on again, turn the rotary function selector [06] to the OFF position
· Then, turn the rotary function selector [06] to the desired function position.
· Hold the Data Hold & Flashlight button [08] to switch the device on and cancel the auto power off function.
MAINTENANCE
When using the voltage tester in compliance with this user manual and all safety instructions, no maintenance is required. If functional errors occur during normal operating, please contact our service center.

After cleaning, do not use the voltage tester for approx. 5 hours.
BATTERY REPLACEMENT
If no signal sound is audible when short-circuiting the test probes, or the auto test shows that the battery voltage is too low, proceed with the battery replacement.
· Completely disconnect voltage tester from all electrical circuits or machines
· Open the battery cover [12] with an appropriate screwdriver.
· Replace by 2 new AA batteries, respecting the polarity.
· Close the battery cover [12] with an appropriate screwdriver.

CLEANING
Prior to cleaning, remove the voltage tester from all measurement circuits. If the instrument is dirty after daily usage, it is advisable to clean it by using a damp cloth and a mild household detergent.
Never use acid detergents or dissolvents for cleaning.

9

SPECIFICATIONS

FUNCTION

RANGE

RESOLUTION

AC Current

200.A

100mA

Over rang protection: Maximum input 200A; Frequency response: 50 to 60Hz

ACCURACY ±(% OF READIING + DIGITS)
±(3% + 5 digits)

AC True RMS Voltage
(Auto sense)

1000V - 6000V 60.00V 600.0V 1000V

1mV 10mV 100mV
1V

Input impedace: 10M ; Low input impedance test voltage: ~3K MAX 600V AC; Accuracy specified from +3.0% of rdg + 8 digits;

Over rang protection: 1000V rms; Frequency response: 50 to 1000Hz (sine wave), 50/60 (all wave)

±(1.2% + 5 digits) ±1.2% + 2 digits) ±(1.5% + 2 digits)

6.00V

1mV

DC Voltage

60.00V

10mV

(Auto sense)

600.0V

100mV

1000V

1V

Input impedance: 10M ; Low input impedance test voltage: ~3K MAX 600V DC; Accuracy specified from +3.% of rdg + 8 digit; Over rang protection 1000V

±(0.9% + 5 digits) ±(1.0 + 2 digits)
±(1.2% + 2 digits)

10

FUNCTION

RANGE

Resistance

600.0 

6.000k 

60.00K 

600.0K 

6.000M 

60.00M 

Over rang protection: 300V rms

RESOLUTION
0.1  1  10  100  1K  10K 

Capacitance

60.00nF

0.01nF

600.0nF

0.1nF

6.000F

1nF

60.00µF

0.01µF

600.µF

0.01µF

4000µF

1µF

*>6nF no specification; Over rang protection: 300V rms

FUNCTION

TEST CONDITION

Diode Conituity

Test current of 1.5mA typical; Open circuit voltage <3VDC typical Test current <0.35mA

Over rang protection: 300V rms

ACCURACY ±(% OF READIING + DIGITS)
±(1.% + 4 digits) ±(1.5% + 4 digits) ±(2.5% + 4 digits) ±(3.5% + 4 digits)
±(3% + 5 digits)
±(3.5% + 10 digits) ±(5.0% + 10 digits)
READING Forward voltage drop of Diode Buzzer makes a long sound, while resistance is less than 50.

11

GENERAL SPECIFICATIONS
Clamp size Display Continuity check Diode test Measurement rate Input impedance Low input impedance Operating temperature Storage temperature Operating humidity Storage humidity Operating altitude Drop protection Battery Battery life Work time
Auto power off

430.200 AMPCLAMP 0.6" (16mm) approx. (6000 counts) LCD display Buzzer sounds < 50 Test current of 3.35mA typical; Open circuit voltage <3VDC typical 3 readings / Second ~10M (VDC & VAC) ~3k (VDC and VAC) 5 - 40°C (41 - 104°F) -20 - 60°C (-4 - 140°F) Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
<80% 2000m (7000ft) max
2m (6.6ft) 2 x 1.5V AA batteries Capacitance ~2000mAh (Alkaline) Without knob, rotary, button, flashlight backlight ~ 100h With knob, rotary, button, flashlight backlight ~40h
Approx. 15min

12

DECLARATION OF CONFORMITY
Futech (Belgium) declares under its own responsibility that this device: - 430.200 AMPCLAMP 200 is in conformity with the standards - EN 61326-1:2013 - EN 61326-2-1:2013 Under Electromagnetic Compatibility (EMC) Directive 2014/30/EU Lier, Belgium, December 22, 2023 Patrick Waûters
Potential misprints are reserved. Images used are not strict. All features, functionality and other product specifications are subject to change without notice or obligation
13

NOTES
14

NOTES
15

USER MANUAL
other languages:
DA DANSK
DE DEUTSCH
ES ESPAÑOL
ET EESTI KEEL
FI SUOMEN KIELI
FR FRANÇAIS
IS ÍSLENSKA
Facebook
@futechtools
LinkedIn
futechtools
World Wide Web
futech-tools.com
YouTube
@futechtools

IT ITALIANO NL NEDERLANDS NO NORSK PT PORTUGUÊS SL SLOVENSCINA SV SVENSKA

231222165547



References

Adobe PDF Library 17.0 Adobe InDesign 18.0 (Macintosh)