Owner's Manual for Panasonic models including: FV-10VEC2R Energy Recovery Ventilator, FV-10VEC2R, Energy Recovery Ventilator, Recovery Ventilator, Ventilator

Service Manual - Panasonic North America

2023-01-11 — WARNING. This service information is designed for experienced repair technicians only and is not designed for use by the general public.

Service Manual (English) (PDF)

Intelli-Balance 100 Mirror ERV | Panasonic North America - Canada

[PDF] Service Manual - Panasonic North Americana.panasonic.com › default › files

PDF preview unavailable. Download the PDF instead.

FV-10VEC2R Service Manual en
PESMX22110001CE
Version:2201
Service Manual Energy Recovery Ventilator (North America Market)
FV-10VEC2R

WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death.

IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer's specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacture. We suggest to handle such parts after the static electricity prevention. It is forbidden to touch the PCB parts by bare hands during the repairing process.

CONTENTS
1.Specifications 2.Parts Identification 3.Wiring Diagram 4. Troubleshooting 4.Parts List

PAGE 1 2~6 7 8 9~11

1. Specifications

<Ventilation Performance>

Model No.

Air direction

Voltage (V)

Frequency (Hz)

Duct

Static pressure

Net air flow (CFM)

Power consumption
(W)

Exhaust Supply Fan unit

Exhaust

0.1"WG 100 100

81

FV-10VEC2R &

120

60 4"/6"

Supply

0.4"WG 100 100

90

Weight Lb.(Kg)
50 (22.4)

<Energy Performance>

Model No.

Mode

Supply temperature

Net

air

flow

Power consumption

°F °C L/s CFM

(W)

32 0 25 53

29

32 0 31 66

39

Heating 32 0 40 85

68

FV-10VEC2R

-13 -25 27 57

77

-13 -25 30 64

100

Cooling 95 35 23 49

32

95 35 31 66

42

Sensible recovery efficiency

Apparent sensible effectiveness

Net moisture transfer

80%

83%

0.78

77% 73%

81% 77%

0.74 0.71

65%

67%

0.71

56%

60%

0.58

Total recovery efficiency

60% 55%

The testing of the ventilation performance and the energy performance in accordance with CSA-C439 standard.

1

2. Parts Identification
Main Body Section
Frame Body Assy 1
SA Fan Assy
10
PCB Box Assy A
(2pcs)
15 Frame Cover Assy

FV-10VEC2R

5

4

A

2

A

(4 pcs)

3

6

A

7

(5pcs)

8

EA Fan Assy
9
11 12
A

C
(6pcs)

D
(2pcs)

13
14 A
(2pcs)
16

17
2

2. Parts Identification
Frame Body Assy

A

20

(2 pcs) (2 pcs)

FV-10VEC2R

A
(8 pcs)

18
(2 pcs)

A
(2 pcs)
SA Fan Assy / EA Fan Assy
31

A
(4pcs)

D
(4pcs)
A
(4pcs)
24

25
23 22
21

19
(2pcs)
A
(4 pcs)
30 29 28 27 26
3

2. Parts Identification
PCB Box Assy
E
(2pcs)
44 D
(2pcs)

45

43

46
47
(2pcs)
A 48
Frame Cover Assy

A
(4pcs)

FV-10VEC2R
32

33

34

38

(3pcs)

35
(3pcs)

36 37

41

E
(4pcs)

42 39

40

50
(4pcs)
51
(4pcs)
49
(2pcs)
A
(4pcs)
4

2. Parts Identification
Main Labels

FV-10VEC2R
52 53

54

55

56

57

58

59
60 62

61 5

2. Parts Identification
Packing Case Assy
63
(4pcs)
65
66
71

FV-10VEC2R
64
(4pcs)
67 68
70 69
(4pcs)

72

73 74 6

3. Wiring diagram

FV-10VEC2R

7

4. Troubleshooting

FV-10VEC2R

If a problem is encountered, please investigate it by going through the following items. If the problem still persists, please disconnect the power and contact the dealer for repair.

Problem

Display
Running Filter indicator indicator (Green) (Red)

Action

Off
1.The ERV doesn't work. On

2.The HVAC/AHU

doesn't work

On

when ERV works.

3.Buzzer sound

(10 sec in a hour)

On

and ERV works.

Check the power cord is connected.

Check the frame cover is closed.

Off

Check the main switch in product body is on.

Check if the spring on the inside of frame cover is damaged or deformed.

ERV running interval according to the ASHRAE time setting.

Off

When outdoor temperature is low ( -22 °F (-30 °C), ERV stops operating automatically.

Damper may be frozen shut, please wait for maximum 24 hours for defrosting.

Off

Please disconnect the power and contact the dealer to check the HVAC/AHU wiring connect.

The RA filter and OA filter need to be maintained.

On

If you do not want the buzzer notification, please

long press the filter reset button for 3 sec to cancel it.

4.Buzzer sound (30 sec in a hour) and ERV doesn't work.

Blink* (0.5 s) Blink* (2 s)
Off
Off
Off

Off
Off
Blink* (0.5 s) Blink* (2 s) Blink* (4 s)

SA motor error, please disconnect the power and contact the dealer for repair.
EA motor error, please disconnect the power and contact the dealer for repair.
OA damper error, please disconnect the power and contact the dealer for repair.
EA damper error, please disconnect the power and contact the dealer for repair.
Center damper error, please disconnect the power and contact the dealer for repair.

Blink* (0.5 s)

On

Temperature sensor error, please disconnect the power and contact the dealer for repair.

On
5.ERV doesn't work base on the setting On air volume.

Blink* (0.5 s)
Off

PCB board error, please disconnect the power and contact the dealer for repair.
When product runs in circulation mode for defrosting, the air volume will be more than setting and sound will be slightly louder than normal operation.
When outdoor temperature is less than 14 °F (-10 °C), the product will restrict air volume automatically to protect energy recovery core.

*The time under "Blink" means the frequency of blink.

8

4. Parts List

Main Body Section

No. Part No.

Part Name

1 FFV1600174M

Frame Body Assy

2 FFV0720012S

Cord Bushing

3 FFV4620115S

Power Cord

4 FFV6710047S

Wiring Cover

5 FFV3740038S

Maintenance Plate

6 FFV3402188M

EA Damper Assy

7 FFV4710448M

Center Damper Assy

8 FFV4300151M

OA Damper Assy

9 FFV3402189M

EA Fan Assy

10 FFV3702280M

SA Fan Assy

11 FFV1600153M

Frame Bracket Assy

12 FFV1600154S

Frame Bracket Hook

13 FFV3402190S

Element Assy

14 FFV3402191S

Element Holder

15 FFV6730102S

RA Filter

16 FFV4300152S

OA Filter M8

17 FFV1600175M

Frame Cover Assy

A FFV7000074S

Truss Tap Screw

B FFV7030008S

Pan Screw

C FFV7000224S

PS Screw

D FFV7000089S

Truss Tap Screw

FV-10VEC2R

Q´ty

Remark

1

1

1

1

1

1

1

1 Include Temperature Sensor

1

1

1

1

1

1

1

1 Merv 8

1

17

2

6

2

Frame Body Assy

No. Part No.

Part Name Q´ty

18 FFV3440021S

Latch

2

19 FFV2220075S

Hinge B

2

20 FFV0000163S

Adapter

2

A FFV7000074S

Truss Tap Screw

16

Remark

9

4. Parts List

SA Fan Assy/EA Fan Assy

No. Part No.

Part Name

21 FFV3730127M Motor Holder Plate

22 FFV2230022S

Holder Gum(B)

23 FFV3402192M EA Motor Assy

(23) FFV3702281M SA Motor Assy

24 FFV2230023S

Holder Gum(A)

25 FFV3730128M Motor Holder

26 FFV3730129M Motor Base

27 FFV7010055S

W asher

28 FFV1610079M Blade

29 FFV7020022S

Nut

30 FFV4710409M Casing

31 FFV4710408M Casing Packing

A FFV7000074S

Truss Tap Screw

D FFV7000089S

Truss Tap Screw

Q´ty
1 1 1 1 1 1 1 1 1 1 1 1 8 4

PCB Box Assy
No. Part No.
32 FFV5580017S 33 FFV5580016M 34 FFV5580010S 35 FFV5580011S 36 FFV5580018M 37 FFV5580019M 38 FFV4690039M 39 FFV5820040S 40 FFV2800028S 41 FFV5820037M 42 FFV5580020M 43 FFV3740055M 44 FFV4690040M 45 FFV4690027M 46 FFV0000164M 47 FFV5820038S 48 FFV4690028S A FFV7000074S D FFV7000089S E FFV7000102S

Part Name
Switch Assy Switch PCB Cover Assy Switch Knob Switch Spring Switch PCB Assy Switch PCB Box Assy PCB Cover Terminal Jumper Cable Temperature Sensor Switch PCB W ire Main PCB Assy Power Connect W ire PCB Box AHU W ire Terminal Partition Plate Truss Tap Screw Truss Tap Screw Pan Tap Screw

Q´ty
1 1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 6

FV-10VEC2R
Remark
Remark
10

4. Parts List

Frame Cover Assy

No. Part No.

Part Name

49 FFV2220076S

Hinge A

50 FFV4620133S

Pressure Plug

51 FFV3440022S

Latch Base

A FFV7000074S

Truss Tap Screw

FV-10VEC2R

Q´ty

Remark

2

4

2

8

Main Labels
No. Part No.
52 FFV3740056M 53 FFV3402226M 54 FFV6730113M 55 FFV5580031M 56 FFV0000189M 57 FFV3402194S 58 FFV2260002S 59 FFV6710056M 60 FFV4020991M 61 FFV5580022S 62 FFV4690029S

Part Name
Maintenance Label EA OA Adapter Label RA SA Adapter Label Wall Switch Label AHU Label Earth Label HVI Mark Wiring Label Name Plate Switch Label Power Cord Label

Q´ty
1 1 1 1 1 1 1 1 1 1 1

Remark

Packing Case Assy

No. Part No.

Part Name

Q´ty

Remark

63 FFV4710410S

Ceiling Inst. Plate

4

64 FFV3440023S

L Plate

4

65 FFV6710049S

Wall Install Bracket

1

66 FFV2220077S

Hanger

1

67 FFV2540249M

Installation Instructions

1 English

68 FFV2540250M

Installation Instructions

1 Spanish,For USA Market.

(68) FFV2540251M

Installation Instructions

1 French,For CA Market.

69 FFV5580023S

Screw Cover

4

70 FFV0010253S

Accessory For Screws

1

71 FFV4710411S

Packing Pad Top

1

72 FFV4650038S

Poly Cover

1

73 FFV4710412S

Packing Pad Bottom

1

74 FFV9001430M

Packing Case Assy

1

11

