Instruction Manual for Noventi models including: C02 Cellarwarn Duo Gas Detector, C02, Cellarwarn Duo Gas Detector
Thank you for selecting the :c/WDC02 and 02 Monitor. It is designed to detect the presence of Carbon Dioxide and Oxygen in the ambient air to protect people ...
1 '"" " Operating SEU (Sensor Unit) LCD
File Info : application/pdf, 2 Pages, 798.45KB
DocumentDocumentC02/02 Cellarwarn Duo Operating Instructions Table of Contents 1 .Product Instruction 2. Package Contenl Check & Main Unit View 3. LCD Display Symbol 4. SEU (Sensor Unit) Function Instruction 5. RDU (Remote Display Unit) Function Instruction 6. Safety Note 7. Caring For Product 8. Installation Instruction 9. Customizing Settings 10. CO2 & 02 & Temperature Specification 11. Weight & Dimension 12. Fault Codes & Troubleshooting Guide Thank you for selecting the :c/WDC02 and 02 Monitor. It is designed to detect the presence of Carbon Dioxide and Oxygen in the ambient air to protect people in confined spaces. High concentrations of CO2 or low concentrations of Oxygen in confined spaces are dangerous, and may lead to- he011h oroblems ranging from headaches and fatigue to asphyxiation and death. The cjwo CO2 & 02 Monitor is with the audible alarm and visual indication which will activate when CO2 or 02 concentration reaches the pre-set level. Detection of high levels of CO2 will also activate relay that could be used for a fan or air-conditioning system to ventilate the confined space. 0nd reduce CO2 concentration and add 02 concentration in the area. The c/w P CO2 & 02 Monitor can be widely used in CO2 storage areas, breweries, wineries, cellars, beverage dispensing areas, and fast food outlets. ZGa21 CO2 & 02 Monitor is cost-effective and has many features: 1. Dual Beam NDIR (Non-Dispersive Infrared) technology is used lo measure CO2concentration up to 50,000ppm (parts per million) and electrochemical technology to measure 02 concentration up to 30%. 2.With the SEU (Sensor Unit) and RDU (Remote Display Unit), ii can connect up to 3 RDU for safely notices. 3. Large digital LCD display clearly indicates the ambient CO2& 02 concentration. 4. Relay output can automatically control a fan lo ventilate confined spaces. · 5.Audible and visual alarm indications. 6. IP65 Waler Proof Protection of SEU (Sensor Unit). 2. Pack e Content Cfleck & Main UnitView The c/w l1 package comprises the following parts: Main Unit· SEU( Sensor Unit) RDU (Remote Display Unit) I Panel holders User manual Accessones: Plug lock Nail cable clip 8 meters (26 feet) communication cable 1 pcs Screw 10pcs 10 pcs Warning paper 1 pcs Expansion lu 10 pcs SEU (Sensor Unit) A 8 p N M K A. LCD display 8. Buzzer (Option) C. Gree LED (Power indication) D. Red 1LED(AL1) E. Red 2 LED( AL2 ) F. Yellow LED( Fault indication) G. Reset Button H. Enter Button I. Mode Button J. CO2 Relay output (red& white: NO, blue& white: NC) K. 02 Relay output (red& white: NO, blue& white: NC) L. Analog output(red&white:CO2, blue &white: 02) M. Communication Cable to RDU N. Power Supply 0. CO2 entry P. 02 entry RDU (Remote Display Unit) QRS T u =:'.::::'.:'.°::'.°:=='--1Hf--V C'.=3---IH-W X z y Q. Green LED(Power indication) R. Red 1LED (AL1 ) S. Red 2 LED ( AL2) T. Yellow LED ( Fault indication) U. LCD display V. Mode Button W. Enter Button X. Buzzer Y. RJ45 Plug for next RDU (Output) Z. RJ45 Plug for SEU( Input) 3. CD Dis ra S mbar .. Symbol CO, YSO,,,. 2 0, I.D% Meaning Description CO2 Concentration ppm ambient CO2 concentration (Parts Per Million) 02 Concentration ambient 02 concentration Alarm alarm icon DIAG Diagnose AL1 C02/02 First Alarm level AL 2 C02/02 Second Alarm level CALIBRATING Calibration ReFactSet Recover Factory Setting ES[ ESC Test communications between the SEU and RDU The relay will be triggered when CO2 concentration exceeds the first alarm level or 02 concentration drops the first alarm level, the Red 1 LED will flash. Safety Notice "ESC" displays on LCD when CO2 concentration exceeds the second alarm level or 02 concentration drops the second alarm level. The Red 1 & Red 2 LEDs will flash. To calibrate the CO2 sensor /02 sensor when the accuracy deviates from the actual C02/O2 concentration. To recover factory default settings and cancel any customized settinQs. To indicate the CO2 leakage once the CO2 level is above the second alarm level. H, Hi The CO2 concentration is above 5%, or the 02 concentration is Higher than 30%. If C02<Alarm1 and 02 >Alarm1, Fan there is no fan running; If CO2 >Alarm1 or 02<Alarm1, fan will run. kmr·att-IGW:P.*tlf[ftffi'i.f(f6JrfurdffrJB,lf?lt,i'.r= The SEU (Sensor Unit) should be placed in a room where -the CO2 is likely to accumulate or 02 reduce, such as a room where CO2 is stored, like an area with CO2 beverages. The large LCD displays the ambient CO2 & 02 concentration. The SEU has the 'DIAG", 'AL1", 'AL2"'CALI', 'ReFactSet' function. The "DIAG" function executes communication tests between the SEU and RDU. The user can do the calibration under the "CALI' mode when necessary. If data-setting is done incorrectly, the user can use the 'ReFactSet" back to the original factory setting. There have 'AL1' 'AL2' two alarm levels, the alarm level is adjustable, the first alarm level of CO2 is with parameter 5000ppm, 1%, 1.5%, 2%, the default first alarm level is 1.5%; the first alarm level of 02 is with parameter 18%,18.5%,19%,19.5%,20%, the default first alarm level is 19%.The second alarm level of CO2 is with parameter 1.5%, 2%, 2.5%, 3%, 3.5%, 4%, the default second alarm level is 3%; the second alarm level of 02 is with parameter 16%,16.5%;17%,17.5%,18%, the default second alarm level is 17%. When the </wll CO2 &02 Monitor detects CO2 concentration exceeds the first alarm level or 02 concentration drops the first alarm level, the red 1 LED will blink the relay will be triggered. When CO2 concentration drops the first alarm level, or 02 concentration rise to the first alarm level, the red 1 LED will stop blinking. If the concentration of CO2 continues to rise above the second alarm level, or the concentration of 02 drops the second alarm level, the red 1 and red 2 LED's will flash together. When CO2 concentration drops below the second alarm level, even to the first alarm level, the red 1 and red 2 lED's will remain blinking (This function is latch design. Based on DIN66532- ). Unless the ZGa21 is restarted, by means of reset button of c/y1 ii or unplug the AC adapter and reconnected it. The green LED will light continuously when the power is_normally supplied. Warning: If the ambient CO2 concentration reaches the second alarm level on SEU & RDU, there will be a safety notice "ESC' displays on the LCD, Careful action, such as ventilating the space, must be taken before entering the room where the SEU is placed. If the communication cable between the SEU & RDU doesn't connect well, like the communication cable looses in the Input port, the fault LED of SEU will blink, reconnect the cable, if the cable is inserted into the output port, on RDU, after one minute, the 'Er7" will flash on LCD. Unplug the cable and plug it into the Input port. The unit will work normal! after corrective action. "I The RDU (Remote Display Unit) should be placed outside the room when in use. The RDU is connected to the SEU with a wire that has a maximum length of 8 meters (26 feet). The RDU should be placed where it can be conveniently observed before entering the room where the SEU is located. The RDU is a repeater, and displays the measurements made by the SEU on an easy-to-read digital LCD along with important safety information. The RDU has 'DIAG' function. The 'DIAG' can test the communication between the SEU and RDU. Resetting the c/w O CO2 and 02 Monitor is only available from SEU. 6:;$afe lllate Warning: Your safety is very important to us. To ensure to use the product correctly and safety, please read these wam·ings and the entire User Manual before using the product. Otherwise, the protection provided by the equipment may be impaired. These warnings provide important safety information and should be observed at all times. 1. Please handle the device carefully; do not subject the product to impact or shock. Otherwise, this may cause the accuracy drift. 2. Do not place the unit or the adaptor near a heat source. Heat can cause distortion of the unit, which may result in an explosion or fire. 3. Do not touch the exposed electronic circuitry of the device under any circumstances, as there is the dangerous of electric shocks. 4. Please use only the included power adaptor. Improper power adaptor or power sources can cause serious damage to the product, or result in injury or death to the user. 5. Please use the 'DIAG" function to verify the communication between SEU and RDU, to make sure the communication between SEU and RDU works normally. 6. Please make sure that lhe power adaptor is mounted by plug lock tightly, so the pcwer adapter can not be disconnected without using of mechanical tools. 7. Do not enter into the room directly if there has safety notice 'ESC' displays on the LCD of SEU & RDU. Some careful and protective action must be taken before entering the roonJ where the SEU is installed. 8. Please take care of cable connection between SEU and RDU. Make sure the cable from SEU is connected into the INPUT port ol RDU. 9. Please ensure the external power supply is normally supplied to ventilation fan while the relay is working. If there has no normally power supply to !_he fan, the relay will not work, which may result in potential danger with high CO2 concentration or low 02 concentration in confined s ace. ....3 · ;" To make sure to receive the maximum benefit from using this product, please observe the follow guidelines. 1. Repair - Do not attempt to repair the product or modify the circuitry by yourself. Please contact your local dealer or a qualified repairman if the product needs servicing, including the replacement or calibration of sensor. 2. Note: The oxygen sensor must be replaced every 3 years. 3. Cleaning - Disconnect the power before cleaning. Use a damp cloth. Do not use liquid cleaning agents such as benzene, thinner or aerosols, as these will damage the device. 4. Maintenance - We recommend users to test the communication between the SEU and RDU under 'DIAG" function to verify the working conditions or the SEU_ and RDU. If the four LED's blink simultaneously, it indicates that SEU and RDU work normally. When the LCD displays a safety icon "ESC", please.take immediate protective action to check if CO2 leakage has occurred. We suggest users to do the calibration and thorough function check once within two years to make sure that the <./wCO2 and 02 Monitor _is \'IOrking properly. !L rnstalratian fnsb;actiatt Please carefully take out the SEU (Sensor Unit), RDU {Remote Display Unit), panel holders, network cable connector, 7 meters communication cable, user manual, plug lock, screws, expansion plugs, nail cable clips, warning paper from the package. Step-by-Step Installation: 1. Choose a suitable location to install the SEU. Fix the panel holder on the wall with the four screws {included); the recommend installation height is about 0.45 meters (1.5 feet) from floor and close to the manifolds and valves as possible. 2. Put the SEU on the panel holder, making sure that they are connected tightly. 3. Fix another panel holder in a suitable location outside the monitored space with screws {included). Push the RDU onto panel holder, and stick the warning paper next to RDU. 4. The communication cable is pre-wired to the SEU. Route the cable to the RDU and fixed the communication cable to the wall by nail cable clips, and then plug the cable into the input port on the RDU. Communication is now ready between the SEU and RDU. 5. The dwtJ CO2 and 02 Monitor has two relay output: one is for CO2 and the other is for 02. The relay cable is pre-wired to SEU. The relay can control a fan or blower to ventilate the monitored space when necessary and the relay will be triggered when the CO2 concentration exceeds the first alarm level or 02 concentration drops the first alarm level. 6. After finishing the installation, Connected the AC power adapter into the electrical supply outlet. Mount the Plug lock by expansion plugs so that the power adapter cannot be disconnected without use of mechanical tools. 7. When the power has been connected, The SEU and the RDU will begin to work. Please use the "DIAG" function to verify the communication between SEU and RDU, the four LED's will blink , after that the communication is ready, the content of display is same on SEU & RDU. Mount the plug lock Power Supply for fan Fan for Ventilation . Power Adapter oI SEU (Sensor unit) 8m(26ft) comr,. cable RDU Display gostonks RDU Display 0 · t(ootpthieon2anld,d/JalrsdyReOhaUin) When power has been connected, the SEU and RDU will begin to monitor the CO2 & 02 concentration. In order to the get the timely alarm safety information and meet the personal requirements, it is advisable to set up the customizing parameter when necessary. Tern erature 'Cl'F: ?¨ YS0,... , 2Y.6'' . YS0 : PRESS CO, on 21.0. ENTER °' 21.0. 0 PRESS 00. YS0,... °' ENTER 2 1.0. 1. Press M?e until the 'AL1' icon flashes 2.Press Enter the 'AL1' icon shows on LCD 3. Press M?e toqo throuoh '18% 18.5%,19%,19.5%,20%' alarm level 4. Press Enter aaain to save the settina after selection Setting the 02 Second Alarm parameter- no. I""' YS0-.,11):fS0-.,,11...YS0-.,.1 ·,0/'2 2 1.0. MODE 0. 1.0. ENTER ·f?,; 1. Press Mode until the · AL2' i?§n flashes 2. Press Enter, the ·AL2' icon shows on LCD 3. Press Mode to ao throuah '16%,16.5% 17%,17.5% 18%' alarm level 4. Press Enter aaain to save the settina after selection Note: The se?¦nd alarm level Should be lower than the first alarm level when setting with the alarm level parameter. Using the CO2 CALI function: P2R1.',0,. Using the DIAG function: 1. Press Mode until the 'DIAG' icon flashes. 2. Press Enter, the four LED's will blink on the. 3. The four LED's will blink simultaneous! on the RDU. Setting the CO2 First Alarm parameter: Setting the CO2 Second Alarm · arameter. 2. Press Enter the 'AL2"icon shows on LCD 3. Press Mode to o throu h '1.5% 2% 2.5%,3%,3.5%,4%' alarm level 4. Press Enter ain to save the settin after selection Note: The second alarm levelshould be h?Þher than the firat a?úrm level when selling with the alann l?·el parameter. Setting the 02 First Alarm parameter: -'j):!'2 00. YS0....... PRESS CO,"(YS0...., PRESS co. YS0....., 1.0. 2 0. MOOE 1.0. ENTEit -!).'.- 19.0. 2. Press Enter, the "CALI' and 'ZEro' icons show on the LCD. Press and hold Mode for al least 10 seconds, 'CALIB?{TING'and 'ZEro' icons will flash simultaneously. The calibration will be done automatically..After about 3 minutes the LCD will display 'Pass' or 'Fail". 'Fail', please try again. 3. Press Enter, the 'CALI'and 'SPAn' icons shaw on the LCD, press and hold Mode for at least 10 seconds, 'CALIBRATING' and 'SPAn"Icon will flash simultaneously and the calibration will be·done automatically. After about 3 minutes the LCD will display 'Pass' or 'Fail'. If 'Fail', please try again. Note: When do the calibration, When do the 'ZEro" Ga/ibration. please enter through N2. When do the 'SPAn'Calibration, please enter through 4% CO2 gas. Be?Ãre doing "ZEro·r SPAn· calibration, it will take about 5 min to enter through CO2 to stabilize. When do "?.Ero"r SPAn" calibration, the reading is beating too often and calibration fails. Using the 02 CALI function : ,.a. ·* !'m. ·* "°' YSO-... PRESS ""' ';{0-. PRESS ""' YSO-... °' 2 i.«iiir SPA -* 2E PRESS eNTEit YSO-. PRESS co, YSO-. r 2E s-* r The 02 CALI function is as same as C02's. Nole: When do the calibration, When do the 'ZE( Cal?ßration, please enter through N2. When do the 'SPA' Calibration, please enter through 21% 02 gas. Before doing 'ZE(fSPA" calibration, it will take about 5 min ta enter through 02 to stabilize. When do 'ZE(fSPA', the reading Is beating too often and calibratn ?¿lls. Using the ReFactSet function: I"' I"°' "' YSO-.,l,sess · 2 I.O, I "°'' · 2YS?X0O-".,1I ,es ·1"·' 2n/.o0._.,I'M"OO"e · 2E/.S0,_,,1" 1. Press Mode until the 'ReFactSet" icon flashes. 2. Press Enter, and lhen oress M?e to choose either 'Yes' or 'No'. 3. Press Enter ?ain to save the selling after seleclina. Note. If the user sets t?Î ?ta or ?£l1brales the se?or tncorr?¶ly, use the ReFa?©Set (recover Ille fact()()' Setting) to come back Ille default factory setting. ·®!®·1-0,WQM ?Y CO2 & 02& Temperature specification: CO2 & 02 Specification Measurement Range CO2: 0 - 50,000ppm(5%) display 02: 0- 30% display Display Resolution CO2: 10ppm al 0-10,000ppm; 100n? at 10,001-50 ?nOoom 02: 0.1% Accuracy CO2: ±100ppm or±5% of reading, whichever is oreater 02: Beller than± 3% of FS over 0.1 to 30% Repeatability C02:±20ppm @400ppm 02: Less than +1.0% Temperature Dependence ±0.2% of reading per ·c or :t2ppm per ·c, whi?¥ever is oreater referenced to 25"C Pressure Deoendence 0.13% of reading per mm Hg Response Time CO2: <60 seconds for 90% response to step chanae 02: <30 seconds for 90% res?ünse to step change AL1 (First Alanm Level) CO2: 5000nMi, 1 / 1.5 / 2 % , Default AL 1= 1.5% 02:18%,18.5%,19%,19.5%,20%, Default AL1=19% AL2 (Second Alarm Level) CO2: 1.5 / 2 / 2.5/ 3 / 3.5 / 4 % , Default AL2= 3% 02: 16%,16.5%,17%,17.5%,18%, Default AL2=17% Warm-Up Time <60 seconds at 22·c Temperature Specification: Temoerature Range o·c to 50'C l32'F to 122'F) Display Resolution 0.1'C(0.1"F) Disolav Options "C/"F Accuracy ±1'C(±2'F) when CO2 con?¤ntration is ?low ?Àrst alanm level Response Time 20-30 minutes (case must equalize with environment) Qperalina Conditions: Operating Temoerature o·c to 4o·c ( 32'F to 104"F) Humidity Ranae 0 - 95% RH non-condensina Storaae Conditions: Star?e Temperature -20·c to 60 ·c (-4'F to 140"F) Power Supply & Relay Output· Power Su olv AC adaoter 110/220 VAC Voltaae 100 - 240 VAC AC Input Frequency Power 50 / 60Hz 1 W maximum @ 115 VAC 60 Hz Reouirement 2 W maximum ?û 230 VAC 50 Hz AC/DC Voltage Output Power Peak lnout Current 6VDC 3.0W 0.5 A from 6 VDC Analog output Two channel linear current output: 4-20mA for 02, RL<150Q; 4-20mA for C02, RL<150Q. Two Relay output: Relay 1(CO2 Relay) operates at Relay Output alarm 1 for CO2, Relay 2(02 Relay) operates at alarm 2 for 02, Peak Current< 2A@30 VDC or 250 VAC, SPDT. 11. Wei ht& Dimension Weight: SEU (Sensor Unit):1200 g (include cables) RDU (Remote Display Unit): 120 g Dimension: SEU (Sensor Unit) mm[inch] mm[inch] 12.. fau(t:C'odes&Tcoualesfrooting; Gai<fe This section includes a list of Frequently Asked Questions for problems you may encounter with the cf.,?Z CO2 &02 Monitor. LCD No Fault Icon Description (of the fault) The ambient temperature has exceeded the '1 Er3 temperature range o·c to 50'C ( 32'F to 122'F) SEU Indication RDU Indication 'Er3'flash Fault LED blink 'Er3'flash Fauit LED blink Suggested Actions This error will disappear when the temperature returns to the range between O'C and 50'C ( 32'F to 122'F) some wrong measurement or 2 Er4 the sensor has exceeded its expected life 'Ei4'?Áash Fault LED blink 'Erl'?Âash Fault LED blink Please unplug the AC adapter a? r?µnnect it If the 'Er4" always appears, please contact with the local dealer. 3 Er5 Er6 EEPROM System Problem 'Er5"& "Er6' "Er7'flash flash, Fault LED Fault LED blink blink Please unplug the AC adapter and reconnect It. If the "Er5, Er6'amays appear, please c011tact with the local dealer. Internal Data 4 Er? Transmission Error ©Please unplug the AC adapter and reconnected 'Er7"flash, Fault LED blink 'Er7'flash, Fault LED Blink it. @Check the RJ45 plug is connected into the INPUT port of RDU,if the 'Er?' disays on the RDU only. ©Please unplug the AC adapter and reconnect ij H 5 Er8 The accuracy of CO2& 02 sensor may deviate from the actual 'Er8"flash LED blink Fault 'Er8'flash Fault LED blink the 'Er8' still appeara, please contact with the local dealer. @Please calibrate the unit, concentration. after the calibration, If the 'Er8' still appears, please contact with the local dealer. '\Yarmng: Tins ver. User mnnual ,s the temporary one. · Distributed by Bracton.com +61 2 9938 1800 Ref.No.: 112013 !o &( (