Installation Guide for HYTRONIK models including: HBHC25-RH, HBHC25-R, HBHC25-W, HBHC25-H, HBHC25-RH, HBHC25 PIR Standalone Motion Sensor, PIR Standalone Motion Sensor, Standalone Motion Sensor, Motion Sensor, Sensor

HYTRONIK HBHC25-RH (01) PDF MANUAL - Manual-Hub.com


File Info : application/pdf, 7 Pages, 1.53MB

PDF preview unavailable. Download the PDF instead.

HYTRONIK HBHC25-RH (01)
Installation and Instruction Manual

PIR Standalone Motion Sensor with
Two DALI Channels Output

5.0 SIG Mesh HBHC25 HBHC25/R HBHC25/W HBHC25/H HBHC25/RH

1. Technical Specifications

Operation frequency Transmission power Range (Typical indoor) Protocol Operating voltage Stand-by power DALI Channel 1 DALI Channel 2 Sensor principle Detection range (Max.)* HBHC25 Detection range (Max.)* HBHC25/R Detection range (Max.)* HBHC25/W
Detection range (Max.)* HBHC25/H
Detection range (Max.)* HBHC25/RH
Detection angle Operation temperature IP rating EMC standard (EMC)
Safety standard (LVD)
RED Certification

2.4 GHz - 2.483 GHz 4 dBm 10~30m
5.0 SIG Mesh 220~240VAC 50/60Hz <1W 50mA, Max. 25 LED drivers 30mA, Max. 15 LED drivers PIR detection Installation Height : 6m Detection Range (Ø) :9m Installation Height : 6m Detection Range(Ø) :10m
Installation Height : 6m Detection Range(Ø) :18m Installation height15m (forklift)
12m (person) Detection range (Ø)24m Installation height20m (forklift)
12m (person) Detection range (Ø)40m 360O
Ta:-20OC~+50OC IP20 EN55015, EN61000, EN61547 EN60669-1/-2-1 AS/NZS60669-1/-2-1 EN300328, EN301489-1/-17
CB, CE , EMC, RED, RCM

2. Download the App
Free App for set-up and commissioning

5.0 SIG mesh

3. Installation
Mechanical Structure & Dimensions
Ø66~68mm

1

2

3 4

5

A

B

* Install blind as required

1

2

3

4

5

* Install lens as required

6

7

1

2

iOS

Android

for iOS

for Android

Smartphone app for both iOS & Android platform

for iPad Koolmesh Pro app for iPad
Web for Web
Web app/platform: www.iot.koolmesh.com

Ø 78
1. Ceiling (drill hole 66~68mm) 2. Carefully prise off the cable clamps. 3. Make connections to the pluggable
terminal blocks. 4. Insert plug connectors and secure using
the provided cable clamps, then clip terminal covers to the base. 5. Fit detection blind (if required) and desired lens. 6. Clip fascia to body. 7. Bend back springs and insert into ceiling.

https://manual-hub.com/

HBHC25-20200302-A0

62.2

62.2

62.2

62.2

62.2

70.5 75.2 70.5 77.6 70.5
81 70.5 80.5 70.5 82.9

HBHC25 Wire Preparation
Wiring Diagram

HBHC25/R

HBHC25/W

HBHC25/H

HBHC25/RH

0.75 - 2.5mm 7-8mm

Pluggable screw terminal. It is recommended to make connections to the terminal before fitting to the sensor.
1. 200 metres (total) max. for 1mm² CSA (Ta = 50) 2. 300 metres (total) max. for 1.5mm² CSA (Ta = 50)

-+ LN LED
LED Driver
DA DA

L 220~240VAC
N

P3 P2 P1 N L

HBHC25

DA1

DA2

Max.15pcs

-+ LN LED
LED Driver
DA DA

-+ LN LED
LED Driver
DA DA

Max.25pcs

-+ LN LED
LED Driver DA DA

4. Dimming Interface Operation Notes
Switch-Dim
The provided Switch-Dim interface allows for a simple dimming method using commercially available non-latching (momentary) wall switches. Detailed Push switch configurations can be set on Koolmesh app.

Switch Function Push switch Simulate sensor

Action Short press (<1 second) * Short press has to be longer than
0.1s, or it will be invalid.
Double push
Long press (1 second)
/

Descriptions

- Turn on/off - Turn on only - Turn off only

- Recall a scene - Exit manual mode - Do nothing

- Turn on only - Turn off only - Recall a scene

- Exit manual mode - Do nothing

- Dimming - Colour tuning - Do nothing

- Upgrade a normal on/off motion sensor to a Bluetooth controlled motion sensor

Subject to change without notice.

https://manual-hub.com/

HBHC25-20200302-A0

5. Detection Pattern & Optional Accessories

1. HBHC25 (Low-bay)
HBHC25: Low-bay flat lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-6m)

A: Tangential movement

B: Radial movement

Mount height

2.5m

h = max.6m

h = max.6m

3m

"
Tangential: max. 9m

# Radial: max. 4m

4m 5m

insensitive

sensitive

insensitive

sensitive

6m

Optional Accessory --- Ceiling/Surface Mount Box: HA03

Tangential (A) max 50m2 (Ø = 8m) max 64m2 (Ø = 9m) max 38m2 (Ø = 7m) max 38m2 (Ø = 7m) max 38m2 (Ø = 7m)

Radial (B) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m)

Ø 94 4.2

75 44 66

Optional Accessory --- Blind Insert for Blocking Certain Detection Angles
Valid Range

Valid Range

Blind Option 1 --- Aisle Detection

Blind Option 2 --- 180º Detection

Subject to change without notice.

https://manual-hub.com/

HBHC25-20200302-A0

2. HBHC25/R (Reinforced Low-bay)
HBHC25/R: Low-bay convex lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-6m)

A: Tangential movement

B: Radial movement

Mount height

2.5m

h = max.6m

h = max.6m

3m

"
Tangential:

max.

10m

# Radial: max. 5m

4m 5m

insensitive

sensitive

insensitive

sensitive

6m

Optional Accessory --- Ceiling/Surface Mount Box: HA03

Tangential (A) max 79m2 (Ø = 10m) max 79m2 (Ø = 10m) max 64m2 (Ø = 9m) max 50m2 (Ø = 8m) max 50m2 (Ø = 8m)

Radial (B) max 20m2 (Ø = 5m) max 20m2 (Ø = 5m) max 20m2 (Ø = 5m) max 20m2 (Ø = 5m) max 20m2 (Ø = 5m)

Ø 94 4.2

75 44 66

Optional Accessory --- Blind Insert for Blocking Certain Detection Angles
Valid Range

Valid Range

Blind Option 1 --- Aisle Detection

Blind Option 2 --- 180º Detection

Subject to change without notice.

https://manual-hub.com/

HBHC25-20200302-A0

3. HBHC25/W (Wide range Low-bay)
HBHC25/W: Low-bay convex lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-6m)

A: Tangential movement

B: Radial movement

Mount height

Tangential (A)

Radial (B)

2.5m

max 254m² (Ø = 18m) max 28m² (Ø = 6m)

h = max.6m

h = max.6m

3m

max 254m² (Ø = 18m) max 28m² (Ø = 6m)

"
Tangential:

max.

18m

# Radial: max. 6m

4m 5m

insensitive

sensitive

insensitive

sensitive

6m

max 154m² (Ø = 14m) max 113m² (Ø = 12m) max 79m² (Ø = 10m)

max 28m² (Ø = 6m) max 28m² (Ø = 6m) max 13m² (Ø = 4m)

Ceiling/Surface Mount Accessory HA03: Default IP20, IP65 can be request with extra big & small water-proof gaskets

Ø 94

1.5 4
75 15.2

Placement Guide and Typical Range

Smart Phone to Device Range

6-10m

10m

The smart device with the App installed will have a typical range of 10m, but varies from device to device. During commissioning, the installer will need to be in range of the devices when searching for devices to add to the network.
Once the devices have been added to the network via the App, the devices will start communicating within the wireless mesh. This means that once the network is complete, all devices are accessible from the smart device when in a 20m range of a single point.

Big and small silicon gasket used to make IP54 degree protection when HBHC25 series device mounted into HA03 housing for ceiling mount

Small silicon water-proof gasket dimension(size:mm)

Big silicon water-proof gasket dimension(size:mm)

Ø 62 Ø 76.5

4.2 48.2 61.8

Subject to change without notice.

https://manual-hub.com/

HBHC25-20200302-A0

4. HBHC25/H (High-bay)
HBHC25/H: High-bay lens detection pattern for forklift @ Ta = 20ºC (Recommended ceiling mount installation height 10m-15m)

A: Tangential movement

B: Radial movement

h = max.15m

"
Tangential:

max.

24m

h = max.15m
# Radial: max. 16m

insensitive

sensitive

insensitive

sensitive

Mount height 10m 11m 12m 13m 14m 15m

Tangential (A) max 380m2 (Ø = 22m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m)

Radial (B) max 201m2 (Ø = 16m) max 201m2 (Ø = 16m) max 201m2 (Ø = 16m) max 177m2 (Ø = 15m) max 133m2 (Ø = 13m) max 113m2 (Ø = 12m)

HBHC25/H: High-bay lens detection pattern for single person @ Ta = 20ºC (Recommended ceiling mount installation height 2.5m-12m)

A: Tangential movement

B: Radial movement

Mount height

2.5m

h = max.12m

"
Tangential:

max.

20m

h = max.12m
# Radial: max. 3m

6m 8m 10m 11m

insensitive

sensitive

insensitive

sensitive

12m

Optional Accessory --- Ceiling/Surface Mount Box: HA03

Tangential (A)

Radial (B)

max 50m2 (Ø = 8m)

max 7m2 (Ø = 3m)

max 104m2 (Ø = 11.5m) max 7m2 (Ø = 3m) max 154m2 (Ø = 14m) max 7m2 (Ø = 3m)

max 227m2 (Ø = 17m) max 269m2 (Ø = 18.5m) max 314m2 (Ø = 20m)

max 7m2 (Ø = 3m) max 7m² (Ø = 3m) max 7m² (Ø = 3m)

Ø 94 4.2

75 44 66

Optional Accessory --- Blind Insert for Blocking Certain Detection Angles
Valid Range

Valid Range

Blind Option 1 --- Aisle Detection
Subject to change without notice.

Blind Option 2 --- 180º Detection

https://manual-hub.com/

HBHC25-20200302-A0

5. HBHC25/RH (Reinforced High-bay with 3-Pyro)
HBHC25/RH: Reinforced high-bay lens detection pattern for forklift @ Ta = 20ºC (Recommended ceiling mount installation height 10m-15m)

A: Tangential movement

B: Radial movement

Mount height 10m

h = max.20m

"
Tangential:

max.

40m

h = max.20m
# Radial: max. 15m

insensitive

sensitive

insensitive

sensitive

11m 12m 13m 14m 15m 20m

Tangential (A)

Radial (B)

max 346m2 (Ø = 21m) max 660m2 (Ø = 29m) max 907m2 (Ø = 34m)

max 177m2 (Ø = 15m) max 177m2 (Ø = 15m) max 154m2 (Ø = 14m)

max 962m2 (Ø = 35m) max 154m2 (Ø = 14m) max 1075m2 (Ø = 37m) max 113m2 (Ø = 12m) max 1256m2 (Ø = 40m) max 113m2 (Ø = 12m)

max 707m2 (Ø = 30m) max 113m2 (Ø = 12m)

HBHC25/RH: Reinforced high-bay lens detection pattern for single person @ Ta = 20OC (Recommended ceiling mount installation height 2.5m-12m)

A: Tangential movement

B: Radial movement

Mount height

2.5m

h = max.12m

"
Tangential:

max.

30m

h = max.12m
# Radial: max. 4m

6m 8m 10m 11m

insensitive

sensitive

insensitive

sensitive

12m

Optional Accessory --- Ceiling/Surface Mount Box: HA03

Tangential (A) max 38m2 (Ø = 7m) max 154m2 (Ø = 14m) max 314m2 (Ø = 20m) max 531m2 (Ø = 26m) max 615m2 (Ø = 28m) max 707m2 (Ø = 30m)

Radial (B) max 7m2 (Ø = 3m) max 7m2 (Ø = 3m) max 7m2 (Ø = 3m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m) max 13m2 (Ø = 4m)

Ø 94 4.2

75 44 66

6. Additional Information / Documents
1.To learn more about detailed product features/functions, please refer to www.hytronik.com/download ->knowledge ->Introduction of App Scenes and Product Functions 2. Regarding precautions for Bluetooth product installation and operation, please kindly refer to www.hytronik.com ->download/knowledge ->Bluetooth Products - Precautions for Product Installation and Operation 3. Data sheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/bluetooth technology ->Bluetooth Sensors 4. Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy

Subject to change without notice.

https://manual-hub.com/

HBHC25-20200302-A0



References