User Guide for R TEC AUTOMATION models including: Interior Sun Sensor, RTMISS, R-TEC Smart Controls

R-TEC Smart Controls - Interior Sun Sensor RTMISS

2021 Rowley Company. All rights reserved. R-TEC ... Use or modification outside the scope of this instruction manual will void warranty. • Installation and ...

• Use or modification outside the scope of this instruction manual will void warranty. • Installation and programming to be performed by a suitably qualified installer. • Use only R-TEC Automation hardware. • Keep clear when in operation. • Replace battery with correctly specified type.

• Use or modification outside the scope of this instruction manual will void warranty. • Installation and programming to be performed by a suitably qualified installer. • Use only R-TEC Automation hardware. • Keep clear when in operation. • Replace battery with correctly specified type. IMPORTANT SAFETY INSTRUCTIONS TO BE READ PRIOR


File Info : application/pdf, 10 Pages, 529.23KB

PDF preview unavailable. Download the PDF instead.

rowley-r-tec-automation-interior-sun-sensor-instructions
R-TEC Smart Controls - Interior Sun Sensor RTMISS
Interior sun sensors automatically manage daylight transitions at each window, minimizing reliance on and costs of artificial light.

FEATURES

2-Way RF Communication

3 Modes of Operation: Close, Open / Close &
Shade Detect

4 Light Sensitivity Levels

Low Battery Warning

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

1

TABLE OF CONTENTS

Technical Data / Pack Contents

3

Safety

4

Installation

5

Sensor Battery

Replacing Battery

Mounting

Functional Overview

6 - 7

Buttons

Modes

View and Change Sensor Mode

Light Levels Of Light Intensity Values

Light Intensity Detection

Low Battery Notification

Up Button

Programming

8

Protocol Selection

Adding or Removing Sensor & Creating Group Control

9

Using Motor P1 Button

Using a Pre-Existing Controller

Troubleshooting

10

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

2

COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: · This device may not cause harmful interference. · This device must accept any interference received, including interference that may cause undesired operation.

TECHNICAL DATA / PACK CONTENTS

PRODUCT SPECIFICATIONS
Parameters Voltage Battery
Radio Frequency Transmitting Power Transmission Range
Standby Current Light Intensity Level Range Temperature Working Range

Value 3 V DC CR2032 433.92 MHz 10 milliwatt 65' 5 uA 15 - 75 Klux 14º F - 122º F (-10º C - 50º C)

PACK CONTENTS
1. Sun Sensor 2. Instruction Manual 3. 3V - CR2032 Battery

1 3/4"

1 3/4"

5/8"

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

3

SAFETY
WARNING
Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Incorrect installation can lead to serious injury and will void manufacturer's liability and warranty.
CAUTION
· Do not expose to moisture or extreme temperatures. · Do not allow children to play with this device. · Use or modification outside the scope of this instruction manual will void warranty. · Installation and programming to be performed by a suitably qualified installer. · Use only R-TEC Automation® hardware. · Keep clear when in operation. · Replace battery with correctly specified type.
IMPORTANT SAFETY INSTRUCTIONS TO BE READ PRIOR TO OPERATION
· It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. · Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge
should not be allowed to use this product. · Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. · Keep away from children.

Do no dispose of in general waste.
Please recycle batteries and damaged electrical products appropriately.

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

4

INSTALLATION
SENSOR BATTERY
Pull battery tab out to activate for first use.

REPLACING BATTERY
Pry open using flat head screwdriver where notches meet on the sensor.

Remove old battery by pressing up from under the
battery's position.

Battery CR2032

Push new battery in with the positive (+) side facing outwards.
Battery CR2032

Replace cover by aligning notches and press together.

MOUNTING
1. Ensure surface on glass is clean and free of dust. 2. On the back of the sensor, peel clear plastic off to reveal adhesive. 3. Find desired position on glass for the sensor and press adhesive side to glass. 4. Check that the glazing or the tint on the window will not affect the functionality of the Sun Sensor. 5. Ensure that the light level is enough to activate the Sun Sensor. If it is possible to measure the light intensity using the
Lux-meter. The values measured should be according to the level of the sensor mode selected.

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

5

FUNCTIONAL OVERVIEW
BUTTONS
Light Level Indicator

UP

P2

Change Light Level

MODES
Mode 1 - DEFAULT Close Mode
Preset light level reached
Light level stays above preset for 2 minutes
Blind goes down
Blind stays down

Mode 2 Open / Close Mode
Preset light level reached
Light level stays above preset for 2 minutes
Blind goes down
Light level goes below the preset value for more than 15 minutes
Blind goes back up

Mode 3 Shade Detect Mode
Preset light level reached
Light level stays above preset for 2 minutes
Blind goes down until sensor is covered
Blind goes up until sensor is uncovered
Light level goes below the preset value for more than 15 minutes
Blind goes back up

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

6

VIEW AND CHANGE SENSOR MODE
To view the current mode: Press the SUN button for one second
1 blink indicates mode 1 2 blinks indicate mode 2 3 blinks indicate mode 3
To change the mode: Hold the SUN button until the LED blinks 5 times. The mode has now shifted up by one. E.g. Mode 2 has changed to Mode 3.

LIGHT LEVELS OF LIGHT INTENSITY VALUES

Light Level
0 Level 1 Level 2 Level 3 Level 4 Level

Luminous flux per unit area
Not Operational 15,000 LUX 30,000 LUX 45,000 LUX 60,000 LUX

TO CHANGE LIGHT LEVEL SETTING:
Press the SUN key repeatedly until the desired light level flashes.

LIGHT INTENSITY DETECTION
Press the SUN and P2 buttons for one second.
Response The unit will indicate light level

Hold the sensor toward the light.

LOW BATTERY NOTIFICATION
When the battery needs changing, the currently selected light level LED will blink every 2 minutes.

UP BUTTON
The UP button can be used to manually override the sensor and tell the shade to go up.

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

7

PROGRAMMING
PROTOCOL SELECTION
R-TEC Automation® motors use the default ARC protocol mode. If your device is in the "EL" mode, to toggle back to the ARC mode follow the steps below.
Hold P2 while inserting battery

To check which mode the sensor is currently in, press the UP or P2 button briefly.
ARC Protocol: The current LED will blink fast 8 times to indicate that the new (ARC) protocol is currently set. *This is the mode needed for your R-TEC Automation® motor to work.
Acmeda "EL" Protocol: The current LED will blink slowly 4 times to indicate that the old protocol is currently set.

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

8

ADDING OR REMOVING SENSOR & CREATING GROUP CONTROL

USING MOTOR P1 BUTTON
Hold P1 button on motor head.

Hold P2 on sensor to add or remove.

Motor Response Approx.

Motor Response Approx.

USING PRE-EXISTING CONTROLLER
A = Existing controller or channel (to keep).

Press P2 on existing controller.

Press P2 a second time on existing controller.

B = controller or channel to add or remove. Press P2 on new sensor.

Motor Response

Motor Response

Motor Response

IMPORTANT
Consult your user manual for your controller or sensor.

© 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC.

9

TROUBLESHOOTING

Problem

Cause

Remedy

Sensor battery is discharged

Replace battery. See page 5.

Motor is not responding

Battery is inserted incorrectly

Check battery polarity. See page 5.

Radio interference / Shielding

Ensure sensor is positioned away from metal objects and that aerial on motor or receiver is kept straight and away from metal.

Sensor distance is too far from remote

Move sensor to a closer position.

Power failure

Check power supply to motor is connected and active.

Incorrect wiring

Check wiring is connected correctly (refer to motor installation instructions).