User Guide for R TEC AUTOMATION models including: Interior Sun Sensor, RTMISS, R-TEC Smart Controls
2021 Rowley Company. All rights reserved. R-TEC ... Use or modification outside the scope of this instruction manual will void warranty. • Installation and ...
• Use or modification outside the scope of this instruction manual will void warranty. • Installation and programming to be performed by a suitably qualified installer. • Use only R-TEC Automation hardware. • Keep clear when in operation. • Replace battery with correctly specified type.
• Use or modification outside the scope of this instruction manual will void warranty. • Installation and programming to be performed by a suitably qualified installer. • Use only R-TEC Automation hardware. • Keep clear when in operation. • Replace battery with correctly specified type. IMPORTANT SAFETY INSTRUCTIONS TO BE READ PRIOR
File Info : application/pdf, 10 Pages, 529.23KB
DocumentDocumentR-TEC Smart Controls - Interior Sun Sensor RTMISS Interior sun sensors automatically manage daylight transitions at each window, minimizing reliance on and costs of artificial light. FEATURES 2-Way RF Communication 3 Modes of Operation: Close, Open / Close & Shade Detect 4 Light Sensitivity Levels Low Battery Warning © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 1 TABLE OF CONTENTS Technical Data / Pack Contents 3 Safety 4 Installation 5 Sensor Battery Replacing Battery Mounting Functional Overview 6 - 7 Buttons Modes View and Change Sensor Mode Light Levels Of Light Intensity Values Light Intensity Detection Low Battery Notification Up Button Programming 8 Protocol Selection Adding or Removing Sensor & Creating Group Control 9 Using Motor P1 Button Using a Pre-Existing Controller Troubleshooting 10 © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 2 COMPLIANCE STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: · This device may not cause harmful interference. · This device must accept any interference received, including interference that may cause undesired operation. TECHNICAL DATA / PACK CONTENTS PRODUCT SPECIFICATIONS Parameters Voltage Battery Radio Frequency Transmitting Power Transmission Range Standby Current Light Intensity Level Range Temperature Working Range Value 3 V DC CR2032 433.92 MHz 10 milliwatt 65' 5 uA 15 - 75 Klux 14º F - 122º F (-10º C - 50º C) PACK CONTENTS 1. Sun Sensor 2. Instruction Manual 3. 3V - CR2032 Battery 1 3/4" 1 3/4" 5/8" © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 3 SAFETY WARNING Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Incorrect installation can lead to serious injury and will void manufacturer's liability and warranty. CAUTION · Do not expose to moisture or extreme temperatures. · Do not allow children to play with this device. · Use or modification outside the scope of this instruction manual will void warranty. · Installation and programming to be performed by a suitably qualified installer. · Use only R-TEC Automation® hardware. · Keep clear when in operation. · Replace battery with correctly specified type. IMPORTANT SAFETY INSTRUCTIONS TO BE READ PRIOR TO OPERATION · It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. · Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge should not be allowed to use this product. · Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. · Keep away from children. Do no dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 4 INSTALLATION SENSOR BATTERY Pull battery tab out to activate for first use. REPLACING BATTERY Pry open using flat head screwdriver where notches meet on the sensor. Remove old battery by pressing up from under the battery's position. Battery CR2032 Push new battery in with the positive (+) side facing outwards. Battery CR2032 Replace cover by aligning notches and press together. MOUNTING 1. Ensure surface on glass is clean and free of dust. 2. On the back of the sensor, peel clear plastic off to reveal adhesive. 3. Find desired position on glass for the sensor and press adhesive side to glass. 4. Check that the glazing or the tint on the window will not affect the functionality of the Sun Sensor. 5. Ensure that the light level is enough to activate the Sun Sensor. If it is possible to measure the light intensity using the Lux-meter. The values measured should be according to the level of the sensor mode selected. © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 5 FUNCTIONAL OVERVIEW BUTTONS Light Level Indicator UP P2 Change Light Level MODES Mode 1 - DEFAULT Close Mode Preset light level reached Light level stays above preset for 2 minutes Blind goes down Blind stays down Mode 2 Open / Close Mode Preset light level reached Light level stays above preset for 2 minutes Blind goes down Light level goes below the preset value for more than 15 minutes Blind goes back up Mode 3 Shade Detect Mode Preset light level reached Light level stays above preset for 2 minutes Blind goes down until sensor is covered Blind goes up until sensor is uncovered Light level goes below the preset value for more than 15 minutes Blind goes back up © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 6 VIEW AND CHANGE SENSOR MODE To view the current mode: Press the SUN button for one second 1 blink indicates mode 1 2 blinks indicate mode 2 3 blinks indicate mode 3 To change the mode: Hold the SUN button until the LED blinks 5 times. The mode has now shifted up by one. E.g. Mode 2 has changed to Mode 3. LIGHT LEVELS OF LIGHT INTENSITY VALUES Light Level 0 Level 1 Level 2 Level 3 Level 4 Level Luminous flux per unit area Not Operational 15,000 LUX 30,000 LUX 45,000 LUX 60,000 LUX TO CHANGE LIGHT LEVEL SETTING: Press the SUN key repeatedly until the desired light level flashes. LIGHT INTENSITY DETECTION Press the SUN and P2 buttons for one second. Response The unit will indicate light level Hold the sensor toward the light. LOW BATTERY NOTIFICATION When the battery needs changing, the currently selected light level LED will blink every 2 minutes. UP BUTTON The UP button can be used to manually override the sensor and tell the shade to go up. © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 7 PROGRAMMING PROTOCOL SELECTION R-TEC Automation® motors use the default ARC protocol mode. If your device is in the "EL" mode, to toggle back to the ARC mode follow the steps below. Hold P2 while inserting battery To check which mode the sensor is currently in, press the UP or P2 button briefly. ARC Protocol: The current LED will blink fast 8 times to indicate that the new (ARC) protocol is currently set. *This is the mode needed for your R-TEC Automation® motor to work. Acmeda "EL" Protocol: The current LED will blink slowly 4 times to indicate that the old protocol is currently set. © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 8 ADDING OR REMOVING SENSOR & CREATING GROUP CONTROL USING MOTOR P1 BUTTON Hold P1 button on motor head. Hold P2 on sensor to add or remove. Motor Response Approx. Motor Response Approx. USING PRE-EXISTING CONTROLLER A = Existing controller or channel (to keep). Press P2 on existing controller. Press P2 a second time on existing controller. B = controller or channel to add or remove. Press P2 on new sensor. Motor Response Motor Response Motor Response IMPORTANT Consult your user manual for your controller or sensor. © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 9 TROUBLESHOOTING Problem Cause Remedy Sensor battery is discharged Replace battery. See page 5. Motor is not responding Battery is inserted incorrectly Check battery polarity. See page 5. Radio interference / Shielding Ensure sensor is positioned away from metal objects and that aerial on motor or receiver is kept straight and away from metal. Sensor distance is too far from remote Move sensor to a closer position. Power failure Check power supply to motor is connected and active. Incorrect wiring Check wiring is connected correctly (refer to motor installation instructions). Any Questions? Contact our R-TEC Automation® in-house experts at 866.985.3423. Email us at RTECAutomation@RowleyCompany.com. © 2021 Rowley® Company. All rights reserved. R-TEC Automation® is a registered trademark of the Rowley® Company, LLC. 10Adobe InDesign 15.1 (Windows) Adobe PDF Library 15.0