User Manual for UEi TEST INSTRUMENTS models including: C165 Combustion Analyzer, C165, Combustion Analyzer, Analyzer
UEI C165 Residential / Commercial Combustion Analyzer
File Info : application/pdf, 12 Pages, 3.78MB
DocumentDocumentC165+ QUICK START GUIDE O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 2 TEMP PRS LINK CO CO C165+ Combustion Analyzer 1-800-547-5740 · Fax: (503) 643-6322 www.ueitest.com · Email: info@ueitest.com C165+ OVERVIEW A. B. UEi TEST INSTRUMENTS www.ueitest.com Tel: 1-800-547-5740 Serial No. N. CO CO-H 2 CO 2 NO O 2 O. Sensors Fitted: C. D. H. E. O2/EFF CO/CO2 TEMP/PRS AUX EXCH TEST I. STATUS ROOM CO P. F. v3 J. 2 TEMP PRS LINK CO CO K. G. C165+ Combustion Analyzer L. M. Q. [Top View] R. T2 T1 P2 P1 S. T. [Bottom View] U. A. On/ Off (Power) Button B. 6 Line Backlit Display · Press any button to turn Back light on C. UP/DOWN Button · Short press to navigate "UP" or "DOWN" D. Pump Toggle button: Long press to pump on/off, short press holds the readings and the screen flashes E. ENTER Button · Short press select current option displayed F. Rotary Dial G. Protective Rubber Boot With Magnets H. Printing and log button: Long press to saving logs and Short press to print on/off I. Water Trap (under Protective Boot) J. Particle Filter (inside water trap) K. LED Water Trap Indication: LED is active while the pump is on to bring user awareness to any condensate building up in the water trap L. Grip Indentation: Indentation for fingers to grip analyzer M. Water Trap Drain Plug: (Red plug; take caution NOT to damage plug when removing protective boot) N. Serial Number QR Code O. Sensors Fitted: (label under Protective Boot) Indication of sensors installed when shipped (CO, CO-H2, CO2, NO, O2) P. Battery Compartment (under Protective Boot) Q. Infrared Printer Port R. Battery Charge USB Adapter Connection S. Temperature Connections · Flue Probe Temperature: T1 · Inlet Temperature: T2 T. Flue Gas Inlet Connection U. Pressure Connections · Pressure: P1 · Differential Pressure: P2 MENU SCREEN - C165+ START UP Press "Power" Button for 2 seconds. The analyzer will perform a 60 second purge. This should be done in fresh air. Rotate Selector Dial to MENU to set up or customize your settings. Selected parameter are highlighted with Display Line Lights on either side. Use and ARROW BUTTONS to scroll menu options. Press Button to edit a parameter. Press and ARROW BUTTONS to change contents of field. Press Button to enter content and move to next field. STATUS SCREEN Rotate Selector Dial to STATUS to view parameters Ta ATM CAL SERIAL NUMBER DATE TIME BATTERY LEVEL Change Fuel Type With the first line selected press and ARROW BUTTONS to change currently selected Fuel. NAT GAS H OIL PELLETS L OIL LPG BUTANE PROPANE Press Button to select. O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 O2 TEMP PRS LINK CO C C165+ Combustion Analyzer O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 2 TEMP PRS LINK CO CO C165+ Combustion Analyzer BEFORE TESTING CHECKLIST o Clean particle filter o Water trap and probe line are free of condensate o All hose and thermocouple connections are properly secured o Water trap is fitted correctly o Power on and zero o Flue gas probe is sampling ambient FRESH air Remove the rubber boot and red drain plug. Allow the water to drain out. Re-insert the rubber plug and replace boot cover. Remove protective rubber boot. Remove water trap from analyzer. Remove particle filter from water trap and replace with new one. Reattach trap and boot. AUXILIARY SCREEN 2 TEMP PRS 2 TEMP PRS O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 LINK CO CO C165+ Combustion Analyzer The AUX screen allows you to assign any of the following parameters on any display line. CO2, CO, NO (if fitted), NOx (if fitted), O2, TF, Ti, Ta, Delta (), Loss, EFg, Xair, Ra (CO/ CO2 Ratio), PI, Fuel Type, PRS or Blank. To customize the settings displayed on screen. Rotate dial to . Scroll or to SCREEN. Press . Scroll or Press . to AUX. Scroll or to select the line to change. Press . Highlighted line shows current selection. Scroll or to change parameters. Press to select. Scroll or to select another line to customize and repeat. When finished, scroll or to BACK. Press . O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 LINK CO CO C165+ Combustion Analyzer When performing a combustion Test. Rotate function rotary dial to AUX to Test while viewing custom parameters that you selected. BASIC CO/COMBUSTION ANALYSIS T2 T1 P2 P1 O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 LINK CO CO C165+ Combustion Analyzer Insert Flue probe into stack. Adjust cone so end of the probe is approximately at the center of the stack. NOTE: You will have to drill a hole at least 3/8". Use appropriate sealing method after testing. Rotate selector dial to O2/Eff to view: O2 Efgc T1 Ta (Status Bar - NAT GAS) Fuel type can be changed via or STATUS setting 2 TEMP PRS 2 TEMP PRS O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 LINK CO CO C165+ Combustion Analyzer Rotate selector dial to CO/ CO2 to view: CO COa CO2 LOSS XAIR O2++ P (Status Bar - NAT GAS) Fuel type can be changed via or STATUS setting. Make any adjustments as needed for proper combustion and wait for analyzer to display change in readings. (Repeat as necessary). T2 T1 P2 P1 Once complete, remove probe from stack, allow analyzer to purge in fresh air until CO sensor readings return to ZERO (0) and O2 readings reading return to 20.9%. Continue to the next test or power analyzer off by pressing , if finished. NOTE: Print and store functions may be used at any time during testing. PRESSURE TEST T2 T1 P2 P1 O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 2 TEMP PRS LINK CO CO C165+ Combustion Analyzer Rotate the selector dial to PRS/TEMP. Press to Zero Pressure sensor. No connections when zeroing pressure. Connect true draft hose to P1. Connect second probe to P2 for differential pressure. Place combustion probe or true draft probe tip in the flue to measure draft. Connect static pressure hose to measure differential pressure. TEMPERATURE TEST O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 2 TEMP PRS LINK CO CO C165+ Combustion Analyzer Rotate the selector dial to PRS/TEMP T2 T1 P2 P1 T2 T1 P2 P1 Connect probe to T1. Connect second probe to T2. Compatible with any K-Type Compatible with any K-Type thermocouple probe or clamp. thermocouple probe or clamp. HEAT EXCHANGER TEST O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 2 TEMP PRS LINK CO CO C165+ Combustion Analyzer Rotate dial to EXCH TEST. Press to start. Scroll or FUELTYPE. Press to select Call for heat on the system. Observe and wait for O2 readings to stabilize. After the blower turns on, press the to start the Post-Blower test The analyzer will wait 60 seconds and then record the Post-Blower values for CO, 02 and Excess Air. O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 2 TEMP PRS LINK CO CO C165+ Combustion Analyzer Test results and LOG number will display when done. Press to print the results. This LOG will be stored in REPORTS/EXCHANGE in the MENU screen. ROOM CO TEST O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 2 TEMP PRS LINK CO CO C165+ Combustion Analyzer No probes or hose connections required for this test. Rotate dial to ROOM CO. Press to select GENERAL test type. CO reading will be logged every minute for 30 minutes. Readings will be stored once the 30 minute test is completed. PRINTING AND LOGGING Test results and LOG number will display when done. Press to print the results. This LOG will be stored in REPORTS/ROOM CO in the MENU screen. O2/EFF CO/CO2 TEMP/PRS Align Printer in line above analyzer. Rotate rotary dial to Menu. Press or Buttons to select Report. Press Button to select Report. Press or Buttons to view types of Reports. Press Button to select Report type. Press Button to View. Press or Buttons to select Log number of that type of Report. Scroll or to PRINT. O2/EFF CO/CO2 TEMP/PRS Press Button to print Report Log Number. SETUP USER FUEL O2/EFF AUX STATUS CO/CO2 TEMP/PRS EXCH TEST ROOM CO v3 2 TEMP PRS LINK CO CO C165+ Combustion Analyzer Rotate dial to Menu UNITS shows press to proceed. POST TESTING POWERING OFF When you power off the C165+, there is a 10 second purge. Remove the probe from the flue and allow analyzer to purge with fresh air until readings return to zero. O2 to 20.9% CAUTION: probe tip will be HOT. CAUTION Make sure you do not exceed the analyzer's operating specifications. · Do not exceed the flue probes maximum temperature (1112°F) · Do not exceed the analyzer's internal temperature range 112°F (50°C) · Do not put the analyzer on a hot surface · Do not exceed the water trap's level · Do not let the particle filter become dirty and blocked BATTERIES The analyzer is fitted with 3 (AA) size rechargeable batteries. Observe correct polarity when replacing. Always check operation immediately after battery replacement. Do not leave batteries in unit for extended periods of non-use. WARNING Do not recharge with Alkaline batteries fitted. Alkaline batteries are not rechargeable. Attempting to recharge alkaline batteries may result in product damage and create a fire risk. Time and Date will need to be reset after changing batteries. Always dispose batteries using approved disposal methods that protect the environment. Download the full Owners Manual at UEiTEST.COM or SCAN THIS CODE WARRANTY The C165+ combustion analyzer is warranted for one year including sensors. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi's option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance (calibration). Batteries and consequential damage resulting from failed batteries are not covered by warranty. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. Instruments out of warranty will be repaired (when repairable) for a service charge. Warranty only covers hardware and does not extend to software applications or accessories. Contact UEi for specific warranty and service information. UEi Test Instruments · 1-800-547-5740 · info@ueitest.com This warranty gives you specific legal rights. You may also have other rights which vary from state to state. ANNUAL RECERTIFICATION SERVICES Complete Care for Your Combustion Analyzer When you: Request Recertification or Service Online Within 1 Year of Purchase or Last Service UEi will: 10 Year Warranty: All UEi combustion analyzers have a standard 1-year warranty. Each recertification extends the warranty for 1 more year for up to 10 years from the date of purchase. Contractors who book recertification of a C160 series analyzer at www.ueitest.com/service within 12 months from either the date of purchase or the date of the last recertification will receive reduced service pricing1 that lowers the cost of ownership and 2 additional benefits: Same Day Service: All qualifying analyzers received for recertification through UEi Service+ are returned on the same business day, GUARANTEED.2 Free Shipping: UEi Service+ offers free shipping both to and from our service center. When customers book their recertification, they receive a prepaid UPS Ground shipping label. 1Pricing subject to change without notice. 2Analyzers that include the additional NO (Nitric Oxide) sensor requires 48-hour turnaround. Register Online Registering you analyzer online is quick and easy. Just log in or setup an account, it only takes a couple of minutes. Once logged in you can register you analyzer by providing some product information and uploading a proof-of-purchase. When it's time to request recertifcation, just log into your account, select the analyzer, select the service and place your order. W W W. U E I T E S T. C O M Copyright © 2023 Kane USA Inc. All Rights Reserved. U S A 1. 8 0 0 . 5 4 7. 5 7 4 0 C A N A DA 1. 8 7 7. 4 7 5 . 0 6 4 8 22136 0823