Explosion-Proof Electrical Machinery and Equipment Type Approval Certificate
Certificate Details
This document certifies that the following electrical machinery and equipment complies with the requirements for type approval.
Certificate 1: CSAUK 25JPN102X
Applicant: | i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany |
Manufacturer: | i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany |
Product Name: | Intrinsically safe explosion-proof structure tablet, docking station |
Model Names: | IS940.1 / IS945.1, IS-DS940.1 |
Type of Explosion Protection: | Intrinsically safe explosion-proof structure "i" |
Ignition Temperature and Explosion Group: | Ex ib IIC T4 Gb |
Rating: | Refer to Appendix 1 |
Conditions of Use: | Refer to Appendix 2 |
Type Approval Number: | CSAUK 25JPN102X |
Validity Period: | 2025/07/23 to 2028/07/22 |
Approver: Prin Spencer, Chief Approver
Certifying Body: CSA Group Testing UK LTD
Approver Name: Michel Hariwell
(This certificate confirms compliance with the Type Approval for Machinery and Equipment Regulations.)
Certificate 2: CSAUK 25JPN103X
Applicant: | i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany |
Manufacturer: | i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany |
Product Name: | Intrinsically safe explosion-proof structure tablet, docking station |
Model Names: | IS940.1 / IS945.1, IS-DS940.1 |
Type of Explosion Protection: | Intrinsically safe explosion-proof structure "i" |
Ignition Temperature and Explosion Group: | Ex ib IIIC T135°C Db |
Rating: | Refer to Appendix 1 |
Conditions of Use: | Refer to Appendix 2 |
Type Approval Number: | CSAUK 25JPN103X |
Validity Period: | 2025/07/23 to 2028/07/22 |
Approver: Prin Spencer, Chief Approver
Certifying Body: CSA Group Testing UK LTD
Approver Name: Michel Hariwell
(This certificate confirms compliance with the Type Approval for Machinery and Equipment Regulations.)
Appendix 1 - Ratings
Tablet Interfaces
The tablet's interfaces are as follows:
Docking
The IS-DS940.1 docking station (12-pin) for charging and data transfer is permitted for use in hazardous areas. The docking interface ports may remain open in hazardous areas. An optional cover can be fitted to prevent contamination. Parameters are defined in document 1065AD05.
ISM (Intrinsic Safety Module)
The 16-pin ISM interface allows the use of approved audio peripherals and add-ons in hazardous areas.
Compatible Peripherals for 16-pin ISM Interface:
- IS-HS2A.1 In-ear headset
- IS-PTTB1A.1 PTT button IS-HDHS1x.1 headset
IS-HDHS1x.1 Stereo headset derivative models:
- IS-HDHS1A.1 Headband
- IS-HDHS1B.1 Neckband
- IS-HDHS1C.1 Helmet mount
Peripherals compatible with the 16-pin ISM interface parameters, in accordance with document 1065AD04, are also permitted.
USB-C
The device is also equipped with a USB-C interface. It can be used for charging and data transfer in normal locations. Peripherals compatible with the USB-C interface include the i.safe PROTECTOR 2.0, other peripherals approved by i.safe MOBILE, or peripherals that guarantee Um = 5.88 V.
Cards for Hazardous Area Use
Card Type | Parameters (i.safe MOBILE GmbH provided or meeting requirements) | ||
---|---|---|---|
microSD Card |
| ||
nano SIM Card |
|
Commercial nano SIM and microSD cards can be inserted into compatible slots in hazardous areas. Their internal electrical capacitance and inductance are negligible and comply with intrinsically safe parameters.
Appendix 2 - Conditions of Use
The following conditions must be observed:
- Permissible ambient temperature range is -20°C to +55°C.
- Permissible charging temperature range is limited to 0°C to +45°C.
- Charging is permitted only via the IS-DS940.1 docking station or the i.safe PROTECTOR 2.0.
- The equipment must not be subjected to excessive UV radiation or high-voltage static electricity.
- In explosive atmospheres, do not replace the battery or use the USB-C interface.
- If no certified peripherals are attached, the cover for the 16-pin ISM interface must always remain closed (refer to certificate appendix document).
- If the IS-DS940.1 docking station is not connected, the docking cover must always remain closed.
Peripheral Use:
Charging and Data | Hazardous Area | Normal Area |
---|---|---|
Docking station IS-DS940.1 (via 12-pin interface) | Docking station IS-DS940.1 (via 12-pin interface) or PROTECTOR 2.0 (via USB-C port) |