Installation Guide for DANTHERMGROUP models including: RJ45 Simplify Monitoring Control System, RJ45, Simplify Monitoring Control System

quick installation - simplify monitoring control system - Dantherm

21 apr 2021 — Dantherm can accept no responsibility for possible errors and changes (en). Der tages forbehold for trykfejl og ændringer (da).

QUICK INSTALLATION


File Info : application/pdf, 12 Pages, 7.08MB

PDF preview unavailable. Download the PDF instead.

simplify-quick-installation-guide
QUICK INSTALLATION
SIMPLIFY MONITORING CONTROL SYSTEM
en
Rev. 1.0 · 2021-W18-4

DANGER WARNING CAUTION

Batteries can be highly dangerous if swallowed. Therefore, keep batteries out of reach of children. If a battery has been swallowed, seek medical advice immediately.
Risk of injury Should a battery have leaked, avoid contact with skin, eyes and mucous membranes. If necessary, rinse the affected areas with plenty of clean water and consult a doctor immediately.
Lithium batteries can explode if inserted the wrong way. Therefore, by all means ensure correct polarity (+/-) when inserting batteries.
Appliances marked with this symbol must not be disposed of along with household refuse! You are legally obliged to dispose of old appliances separately from household refuse. For information about how to despose, contact local authorities.

Batteries must not be disposed of along with household refuse! You are legally obliged to dispose of flat batteries at a local authority collection point or to return them to a battery retailer.

Dantherm can accept no responsibility for possible errors and changes (en) Der tages forbehold for trykfejl og ændringer (da) Irrtümer und Änderungen vorbehalten (de) Dantherm n'assume aucune responsabilité pour erreurs et modifications éventuelles (fr)
2

en

Content of suitcase may vary
Control Unit

Quick Start Guide
QSuimicpkliinfystmalolantiitoonring control system
Quick Guide

Sensor Probe Sensor Box

Lithium Battery
LITHIUM

Relay Box
3

Simplify Monitoring Control System
1

Android 5.1 or later version

Download APP

IOS IOS10 or later version

2

SCAN all the components QR-code in the order as shown:

1A:

1

· Name Control Unit

· Press "SENSORS"

Control Unit
2
Sensor Box

2A: · Name all Sensor Boxes
· Press ADD or +

! OBS!

3
Relay Box

3A: (same tab as "SENSORS") · Name all Relay Boxes
· Press ADD or +

If CDT's are fitted with Integration Box · Scan the QR code on the CDT, name it and press ADD or +. If Simplify CC4 box is used: · Scan the QR code on the box, name it and press ADD or +
When all components are scanned and named: · Press "Control Unit" · "Register"

Control Unit
Check installation at: https://dantherm.clouddashboard.net Enter username and password

Dashboard

4

en

3

4

5

Place Control Unit on desired location

E.g. you can apply the Control Unit, by using the magnets on the backside
6

5

Signal Funktion

7

GSM signal

Flashing: Start-up/installation phase or in the absence of contact with sensor boxes. Do not connect sensor boxes untill green LED flash on control box Constant: All sensor boxes has contact to the Control Unit No 230 V power supply Emergency power: ON

8

3

21

Power on: Connected to Contol Unit:

! OBS!

Various equipment can be connected to the Relay Box

6

en

9

"ON"

10

NB: Click lock, insert to activate

"ON"

When the sensor probe is inserted into the socket, the sensor box is"ON"

! OBS!

Remember to disconnect the sensor probe when sensor box is not in use, in order to prevent the battery from running out of power . Sensor is now in "OFF" position
NB: Click lock

"OFF"

7

11

! OBS!

https:\\dantherm.clouddashboard.net Check, that all components are "ACTIVE" in the dashboard

8

en

How to close a case
1
2

Scan QR-code Control Unit

3

4

Place components in the suitcase
Quick Start Guide
QSiumicpkliifnysmtaollnatitioonring control system

! OBS!

Check that case is archived in DASHBOARD

9

?
Download full version https://support.dantherm.com
10

en

Declaration of Conformity
Electronics
Dantherm A/S Marienlystvej 65 DK - 7800 Skive
Tel.: +45 96 14 37 00 Fax: +45 96 14 38 00

Declaration of following product:
Product name: Simplify control unit, Simplify sensor box, Simplify on/off relay, Simplify integration sensor
Product no.: 380000, 380003, 380005, 380006

The product is in conformity with the following directives:

2014/35/EU

Low Voltage Directive

2014/53/EU

Radio Equipment Directive

2014/30/EU

Electromagnetic Compatibility Directive

2014/29/EU

RoHS Directive

1907/2006/EC

REACH Regulation

- and is manufactured in conformity with the following harmonised standards:

* EN62368-1:2020

Audio/video, information, and communication technology equipment ­ Part 1:

Safety requirements

*EN 301 489-1 V2.1.1:2017 Electromagnetic compatibility and Radio spectrum Matters (ERM);

*EN 301 489-3 V2.1.1:2019 Electromagnetic compatibility and Radio spectrum Matters (ERM)

*EN 301 511 V12.5.1:2017 Global System for Mobile communications (GSM).

*EN 300 220-2 V3.2.1:2018 Short Range Devices (SRD) operating in the frequency range 25 MHz to 1000 MHz; Part 2

*EN 300 220-1 V3.1.1:2017 Short Range Devices (SRD) operating in the frequency range 25 MHz to 1000 MHz ; Part 1

Skive, 2021-04-21.

Product Development

Managing director Jakob Bonde Jessen

11

Manufacturers details: Dantherm Intelligent Monitoring A/S Kirkebjerg Parkvej 12 Brøndby DK 2605 Denmark t. +45 70 22 11 20 e. info@dantherm.com
KEEP UPDATED FOLLOW US ON:

danthermgroup.com

*109095* 109095



References

Adobe PDF Library 15.0 Adobe InDesign 16.2 (Windows)