User Guide for BEA models including: BEA, Product Name IXIO-DT1 V, Model Numbers 75.5816.13, 10IXIODT1, 20.5349, 20.2009, 50.1818, 75.5816, 75.1220, 75.0128, IXIO-DT1 V Motion And Presence Sensor, IXIO-DT1 V, Motion And Presence Sensor, And Presence Sensor, Presence Sensor, Sensor

[PDF] MOTION AND PRESENCE SENSOR WITH CAMERA FOR SLIDING ...

Sensor power and camera power must be supplied from a Class 2 supply source limited to 15 W. Sensor is intended to be monitored for proper operation by the ...


File Info : application/pdf, 16 Pages, 2.46MB

PDF preview unavailable. Download the PDF instead.

75.5816.13.EN-IXIO-DT1-V-20240722
ENGLISH

Visit website for available languages of this document.
Download the BEA DECODER app for a quick overview of settings
WHAT'S IN THE BOX
1

IXIO-DT1 V
MOTION AND PRESENCE SENSOR WITH CAMERA FOR SLIDING DOORS
Software version 6.3 / Configuration 42.4463.03 (refer to Admin menu for product software vesion)
a b

a
2

g c
b

d

ef

1. cover (10.1279 + 20.2009 cable) a. LED window b. camera
2. sensor (10IXIODT1) a. radar antenna b. AIR curtain width adjustment c. LCD d. AIR lenses e. AIR curtain angle adjustment knob f. main adjustment knob g. main connector
3. harness (20.5349) 4. camera harness (20.2009) 5. screw kit (50.1818) 6. User's Guide (75.5816) 7. Quick Guide (75.1220) 8. Mounting Template (75.0128)
75.5816.13 IXIO-DT1 V 20240722

3

4

5

20.5308.XX

6

USER'S GUIDE

7

QUICK GUIDE

8

MOUNTING TEMPLATE

Page 1 of 16

INSTALLATION

The sensor should be mounted securely to avoid extreme vibrations.

Do not cover the sensor.

Avoid moving objects and light sources in the detection field.

MAINTENANCE

It is recommended to clean the optical parts at least once a year or more if required due to environmental conditions.

Avoid highly reflective objects in the infrared field.
Do not use aggressive products to clean the optical parts.

SAFETY

The door control unit and the header cover profile must be correctly grounded.

Only trained and qualified personnel are recommended for installation and setup of the sensor.

Following installation, always test for proper operation (according to ANSI 156.10) before leaving the premises.

The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel.

This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards. Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer's recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call ­ examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code). Verify that all appropriate industry signage, warning labels, and placards are in place.

Page 2 of 16

75.5816.13 IXIO-DT1 V 20240722

TECHNICAL SPECIFICATIONS

TECHNOLOGY / PERFORMANCE

Detection mode: Technology:
Mounting height:

Motion minimum detection speed: 2 in/s

Presence typical response time: < 200 ms (max: 500 ms)

Microwave doppler radar Transmitter frequency: 24.150 GHz Transmitter radiated power: < 20 dBm EIRP Transmitter power density: < 5 mW/cm2

Active infrared with background analysis Spot: 2" × 2" (typ) Number of spots: max. 24 per curtain Number of curtains: 2

6'6" ­ 11'6"

local regulations may impact acceptable mounting height (pedestrian applications only)

Sensor temperature -13 ­ 131 °F *

range:

0 ­ 95% relative humidity, non-condensing

LCD screen is operational from 14 ­ 131 °F. The sensor may still be programmed in colder temperatures, but with the remote control.

ELECTRICAL

Output:

Relay 1 Relay 2

Electromechanical relay (potential and polarity free) Max. contact current: 1 A Max. contact voltage: 30 VAC Adjustable hold time: 0.5 ­ 9 s
Solid-state relay (potential and polarity free) Max. contact current: 100 mA Max. contact voltage: 42 VDC / 30 VAC

Test/Monitoring input:

Sensitivity: Low: < 1 V High: > 10 V (max. 30 V)
Response time on test request: typical < 5 ms

Supply voltage:

12 ­ 24 VAC ±10% 12 ­ 30 VDC ±10%

to be operated from SELV-compatible power supplies only

Power consumption: < 2.5 W

Noise:

< 70 dB

CAMERA

Voltage regulator (built into wire harness): 6.6 ­ 36 VDC (±10%), 6 ­ 28 VAC (±10%)

Operating temperature: -22 ­ 140 °F (max. RH: 95%) Video output: 1.0 (Vp-p) / 75

Image Sensor: CMOS

Horizontal resolution: 480 TVL

NTSC output: 720 (H) × 480 (V)

Sync system: Inter-Sync

Frame rate: 30 fps

Minimum illumination: 0.01 LUX

AE control: auto

Gain control: auto

Electronic shutter: 1 s ~ 1/10,000s

S/N ratio: > 50 dB

AWB: Auto

PHYSICAL

Degree of protection: IP54

COMPLIANCE

FCC certification:

FCC: G9B-100606 IC: 4680A-100606

Compliance:

ISO 13849 PL «c» CAT. 2 (under the condition that the door control system monitors the sensor at least once per door cycle)

Specifications are subject to change without prior notice. All values measured in specific conditions.

75.5816.13 IXIO-DT1 V 20240722

Page 3 of 16

HOW TO USE THE LCD
DISPLAY DURING NORMAL FUNCTION

Activation impulse

Safety

Negative display = active output

FACTORY VALUE VS. SAVED VALUE displayed value = factory value

To adjust contrast, push and turn the grey button simultaneously. During normal function only.
displayed value =
saved value

NAVIGATING IN MENUS

1) Push to enter the LCD menu. 2) Enter password, if necessary. 3) Select language before entering the first LCD menu.
Password
XXXX

Not during the first minute after power-on of the sensor.

During the first 30 seconds after power-on of the sensor or later in the diagnostics menu.

= scroll

= select

Select Back to return to previous menu or display.
Select More to go to next level: - basic settings (MENU 1) - advanced settings (MENU 2) - diagnostics (MENU 3)

CHANGING A ZIP CODE

See application note on ZIP CODE (76.0024).

1) Navigate to menu 3 (Diagnostics).

2) Select "ZIP code".

3) Change the code as desired.

ZIP code ID #

ZIP code E24 1 56-KG4 01 0 800/02F

To activate the new ZIP code, you must validate the last digit (see below):
v = valid ZIP code (values will be changed accordingly) x = invalid ZIP code (no values will be changed) v/x = valid ZIP code, but from a different product

ZIP code
... H24 1 56-KG4
01 0 800/02F

ZIP code V

*only available values will be changed*

ZIP code E24 1 56-KG4 01 0 800/02F
ZIP code E24 1 56-KG4 01 0 800/02F
ZIP code H24 1 56-KG4 01 0 800/02F

VALUE CHECK WITH REMOTE CONTROL

Page 4 of 16

Pressing a parameter symbol on your remote control displays the saved value directly on the LCD screen. Additionally, the green LED will blink the number of times that the parameter is set to. Do not unlock first.
Note: When querying FIELD SHAPE, the green LED will blink the number of times that it is set to, and then the green LED will blink either 1 time (narrow shape) or 2 times (wide shape).
75.5816.13 IXIO-DT1 V 20240722

1 MOUNTING & WIRING
MOUNTING
Using the provided mounting template, mount the sensor, ensuring that the bottom of the sensor is within 2 inches of the bottom of the door header. Refer to Application Note 76.0035 if an IXIO Spacer is required for the given application. Route the harness (20.5349) using the harness clip as shown in the exploded view of the mounting illustration.
Mounting is compatible with the WIZARD.

max. 2 in

Sensor connectivity (power and relays) must utilize only the supplied harness.
Sensor power and camera power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator or system.
Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the
harness and/or IXIO sensor.

DOOR CONTROL

SENSOR

WIRING
RED BLACK BROWN BLUE WHITE (COM)
YELLOW (N.C) GREEN (N.O.) PURPLE PURPLE

POWER SUPPLY POWER SUPPLY
SAFETY INPUT SAFETY INPUT OPENING INPUT
OPENING INPUT OPENING INPUT
TEST OUTPUT* TEST OUTPUT*

CAMERA HARNESS FOR DT1 V

Voltage Regulator

VOLTAGE

Power:

12 ­ 24 VAC, 50/60 Hz 12 ­ 30 VDC 2.5 W (max)

Test:

low: < 1 V high: > 10 V (30 V max.) response time: typ. < 5 ms

* The sensor LED will briefly flash RED during monitoring communication with door control, indicating that external monitoring is functional. Monitoring functionality must be active on the sensor, door control, and monitoring wires must be properly connected to the door control.

RCA VIDEO OUT (female)
POWER 6 ­ 28 VAC ±10% 6.6 ­ 36 VDC ±10%

75.5816.13 IXIO-DT1 V 20240722

Page 5 of 16

2 RADAR OPENING IMPULSE FIELD

green LED = motion detection

The size of the detection field varies according to the mounting height of the sensor. The following graphics are representations ­ not default settings.
ANGLE

7.2 ft

field size: 9 immunity: 2

from 15° to 45°, default 30 ° 7.2 ft
from -15° to 15°, default 0° WIDTH
7.2 ft
13' x 6'6" (wide) 7.2 ft

field size: 9 immunity: 2

or

field size: 9 immunity: 2

field size: 9

or

immunity: 2

6'6" x 8' (narrow) Page 6 of 16

1 × 1 grid is approximately 3.28 ft × 3.28 ft. 75.5816.13 IXIO-DT1 V 20240722

3 INFRARED SAFETY FIELD
ANGLE

red LED = presence detection

Activate the visible spots to verify the position of the AIR curtain. Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
OUR
x2

The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 8 in.
C1 = closest to sliding door C2 = farthest from sliding door
DOOR
C1
C2

If necessary, adjust the AIR curtain angle (from -7° to 4°, default 0°).
CLOSER

max. 3 in

AWAY

WIDTH

Part of the detection field can be masked to reduce its width. The arrow position determines the width of the detection field. The size of the detection field varies according to the mounting height and the settings of the sensor.
Wide setting has 1:1 ratio. For example, a 6-foot mounting height will project a 6-foot detection width at floor.
Always verify the actual detection field width by walk-testing according to ANSI 156.10.

75.5816.13 IXIO-DT1 V 20240722

Additional adjustments are possible by LCD or remote control (see OVERVIEW OF SETTINGS).
Page 7 of 16

4 SETUP
Set up the sensor using either push-buttons or the remote control. STEP OUT OF THE INFRARED FIELD!

SETUP 1 (QUICK)

either hold the knob for 2 seconds, or use the remote

control buttons as specified

+

2 s

SETUP 2 (ASSISTED) test of full door cycle + reference picture

+

either hold the knob for 4 seconds, or use the remote

control buttons as specified

4 s

+

TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES! LED flashes red-green

Page 8 of 16

75.5816.13 IXIO-DT1 V 20240722

OVERVIEW OF SETTINGS

RC BUTTONS

01 23456789
Back More

RAD: FIELDSIZE

small

>

>

>

>

>

>

>

>

large

RAD: SHAPE

LCD: "narrow" and "wide" setting options (default = wide)

Remote Control:

= wide,

= narrow

AIR: WIDTH

see note 1

AIR: OUTPUT
TEST More Back

DeEner/NO Energ/NC

NC

NO

Energ/NC DeEner/NO

NC

NO

off

on on+auto

see note 2 see note 3

BASIC

+ +

Back More

RAD: FIELDSIZE

small

>

>

>

>

>

RAD: IMMUNITY

low

>

>

>

>

RAD: DIRECTION off

bi

uni

MTF

RAD: HOLDTIME auto

1 s

2 s

3 s

4 s

5 s

RAD: REENTRY

small

>

>

>

>

>

RAD: OUTPUT

DeEner/NO Energ/NC

NC

NO

Energ/NC DeEner/NO

NC

NO

AIR: IMMUNITY

normal enhanced

AIR: WIDTH

>

>

>

large

>

>

>

high

uni + reentry

see note 4

6 s

7 s

8 s

9 s see note 5

>

>

>

large

see note 2

mode B

see note 1

ADVANCED

AIR: NUMBER AIR: PRESENCE TIME AIR: FREQ

1

2

30 s 1 min 2 min 5 min 10 min 20 min 60 min infinte

A

B

AIR: OUTPUT TEST REDIRECTION

DeEner/NO Energ/NC

NC

NO

Energ/NC DeEner/NO

NC

NO

off

on on+auto

R1 MW R1MWorIR

R2 IR

R2 IR

see note 2 see note 3 see note 6

FACTORY RESET

full reset

partial reset

see note 7

Back More

factory value

ZIP CODE

all parameter settings in zipped format (see application note on ZIP CODE ­ 76.0024)

ID #

unique ID-number

CONFIG P/N

motion

SOFT P/N

(green)

ERROR LOG

last 10 errors + day indication

AIR: SPOTVIEW view of spot(s) that trigger detection

presence

AIR: C1 ENERG signal amplitude received on curtain

(red)

AIR: C2 ENERG signal amplitude received on curtain 2 POWERSUPPLY supply voltage at power connector OPERATINGTIME power duration since first startup

RESET LOG PASSWORD ADMIN

delete all saved errors LCD and remote control password (0000= no password) enter code to access admin mode

75.5816.13 IXIO-DT1 V 20240722

Page 9 of 16

DIAGNOSTICS

OVERVIEW OF SETTINGS (cont.)

NOTES

Note 1 Note 2
Note 3 Note 4 Note 5

Always use a screwdriver when making further AIR adjustments to the arrow position on the sensor.

RADAR NO = normally open NC = normally closed

AIR NO = normally open NC = normally closed

DeEner = de-energized relay (active) Energ = energized relay (passive) The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional.
Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control. MTF = uni-directional with motion-tracking feature
uni + reentry: BEA recommends only adjusting using the LCD Auto mode evaluates traffic rate and adjusts hold time from 0.5 to 3 seconds

Note 6 Note 7

REDIRECTION setting (F1 on remote control): R1-MW, R2-IR (F1=0):
R1 = MW (i.e. motion detection) R2 = IR (i.e. presence detection) R1-MW or IR, R2-IR (F1=1): R1 = MW or IR (i.e. motion or presence detection) R2 = IR (i.e. presence detection) partial: outputs are not reset

Page 10 of 16

75.5816.13 IXIO-DT1 V 20240722

LED SIGNALS
COLORS (green) Motion detection
(red) Presence detection

BEHAVIORS LED flashes LED flashes quickly
x LED flashes x times

LED flashes red-green LED is off

TROUBLESHOOTING

E1: ORANGE LED flashes
1 1x
E2: ORANGE LED flashes
2 2x

The sensor signals an internal fault.
The power supply voltage is too low/high.

Replace sensor.
Check power supply voltage in diagnotistics menu (menu 3) of the LCD. Check wiring.

E4: ORANGE LED flashes The sensor does not receive

4 4x

enough AIR energy.

Decrease the angle of the AIR curtains. Increase the AIR immunity filter.

Deactivate curtain #2 (C2, outer curtain).

E5: ORANGE LED flashes The sensor receives too much

5 5x

AIR energy.

Slightly increase the angle of the AIR curtains. Decrease the AIR immunity filter.

E8: ORANGE LED flashes
8 8x
ORANGE LED is on
RED LED flashes quickly after an assisted setup

The sensor is disturbed by external elements. AIR power emitter is faulty.
The sensor encounters a memory problem.
The sensor sees the door during assisted setup.

Eliminate the cause of disturbance (lamps, rain cover, door controller housing properly grounded). Replace sensor.
Cut and restore power supply.
If ORANGE LED illuminates again, replace the sensor. Move the AIR curtains away from the door.
Install the sensor as close to the door as possible. If needed, use a bracket assembly. Ensure that the bottom of the sensor is mounted within 2" of the bottom of the door header. Launch a new assisted setup.

RED LED illuminates sporadically

The sensor vibrates.

Check if the sensor is secure. Check position of cable and cover.

The sensor sees the door.

Adjust the AIR angle and launch an assisted setup.

The sensor is disturbed by external conditions.

Increase the AIR immunity filter.

75.5816.13 IXIO-DT1 V 20240722

Page 11 of 16

TROUBLESHOOTING (cont.)

GREEN LED illuminates sporadically

The sensor is disturbed by rain and/or leaves.
Ghosting created by door movement.
The sensor vibrates.

The sensor sees the door or other moving objects.

The LED and the LCD displays are off

No power to sensor.

The reaction of the door does not correspond with the LED signal
Cannot access LCD menu or change parameters via remote control
Sensor does not respond to remote control
RED Visible External Monitoring (Test Indication LED) does not flash

Incorrect output configuration / wiring.
The sensor is protected by a password.
Dead batteries.
Monitoring installation/setup error.

RED Visible External Monitoring (Test Indication LED) flashes continuously
Door cycles open and remains open

Sensor malfunction. Wiring issue. Door control not set correctly.
Door control monitoring set to Active High. Safety and/or Motion output is set incorrectly.

Increase radar immunity filter.
Change radar field angle.
Check if the sensor and door cover is secure. Check position of cable and cover. Remove the objects if possible. Change radar field size, angle, or immunity. Check wiring. Check for correct power supply. Check output configuration setting. Check wiring. Enter the correct password. If you forgot the code, cut and restore the power supply to access the sensor without entering a password during 1 minute. Replace batteries.
Verify door control is capable of monitoring and the sensor monitoring wires are properly connected to the door control. Verify monitoring (TEST) is ON in the sensor settings. Replace the sensor. Verify wiring. Verify door control monitoring set to Active Low.
Set door control monitoring to Active Low.
Correctly set the given output required for the door control.

Can't find your answer? Visit www.beainc.com or scan QR code for Frequently Asked Questions!

Before contacting BEA Technical Support, locate the serial and CAN numbers of your sensor.

SERIAL NUMBER

view: back of sensor

CAN NUMBER back

view: top of sensor

front

Page 12 of 16

75.5816.13 IXIO-DT1 V 20240722

NOTES

75.5816.13 IXIO-DT1 V 20240722

Page 13 of 16

NOTES

Page 14 of 16

75.5816.13 IXIO-DT1 V 20240722

ACCESSORIES AND REPLACEMENT PARTS
ACCESSORIES

10IMB
Mounting bracket adapter

10CDA Curved door accessory

10RETROFITSPACER 10MINIBRACKET

Retrofit Spacer Kit

Short, adjustable,

(includes spacer, 2.5"

mounting bracket

harness, and 9" harness)

20.5302 Retrofit harness

10REMOTE
BEA universal remote control

REPLACEMENT PARTS

10.1279
Replacement cover (includes camera)

20.5349 Replacement harness

20.2009
Replacement camera harness

75.5816.13 IXIO-DT1 V 20240722

Page 15 of 16

©BEA | Original Instructions | PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOR PRINTING

Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462

General Tech Questions: techservices-us@BEAsensors.com | www.BEAsensors.com

Page 16 of 16

75.5816.13 IXIO-DT1 V 20240722

