User Guide for BEA models including: BEA, Product Name IXIO-DT1 V, Model Numbers 75.5816.13, 10IXIODT1, 20.5349, 20.2009, 50.1818, 75.5816, 75.1220, 75.0128, IXIO-DT1 V Motion And Presence Sensor, IXIO-DT1 V, Motion And Presence Sensor, And Presence Sensor, Presence Sensor, Sensor
Sensor power and camera power must be supplied from a Class 2 supply source limited to 15 W. Sensor is intended to be monitored for proper operation by the ...
File Info : application/pdf, 16 Pages, 2.46MB
DocumentDocumentENGLISH Visit website for available languages of this document. Download the BEA DECODER app for a quick overview of settings WHAT'S IN THE BOX 1 IXIO-DT1 V MOTION AND PRESENCE SENSOR WITH CAMERA FOR SLIDING DOORS Software version 6.3 / Configuration 42.4463.03 (refer to Admin menu for product software vesion) a b a 2 g c b d ef 1. cover (10.1279 + 20.2009 cable) a. LED window b. camera 2. sensor (10IXIODT1) a. radar antenna b. AIR curtain width adjustment c. LCD d. AIR lenses e. AIR curtain angle adjustment knob f. main adjustment knob g. main connector 3. harness (20.5349) 4. camera harness (20.2009) 5. screw kit (50.1818) 6. User's Guide (75.5816) 7. Quick Guide (75.1220) 8. Mounting Template (75.0128) 75.5816.13 IXIO-DT1 V 20240722 3 4 5 20.5308.XX 6 USER'S GUIDE 7 QUICK GUIDE 8 MOUNTING TEMPLATE Page 1 of 16 INSTALLATION The sensor should be mounted securely to avoid extreme vibrations. Do not cover the sensor. Avoid moving objects and light sources in the detection field. MAINTENANCE It is recommended to clean the optical parts at least once a year or more if required due to environmental conditions. Avoid highly reflective objects in the infrared field. Do not use aggressive products to clean the optical parts. SAFETY The door control unit and the header cover profile must be correctly grounded. Only trained and qualified personnel are recommended for installation and setup of the sensor. Following installation, always test for proper operation (according to ANSI 156.10) before leaving the premises. The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel. This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards. Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer's recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code). Verify that all appropriate industry signage, warning labels, and placards are in place. Page 2 of 16 75.5816.13 IXIO-DT1 V 20240722 TECHNICAL SPECIFICATIONS TECHNOLOGY / PERFORMANCE Detection mode: Technology: Mounting height: Motion minimum detection speed: 2 in/s Presence typical response time: < 200 ms (max: 500 ms) Microwave doppler radar Transmitter frequency: 24.150 GHz Transmitter radiated power: < 20 dBm EIRP Transmitter power density: < 5 mW/cm2 Active infrared with background analysis Spot: 2" × 2" (typ) Number of spots: max. 24 per curtain Number of curtains: 2 6'6" 11'6" local regulations may impact acceptable mounting height (pedestrian applications only) Sensor temperature -13 131 °F * range: 0 95% relative humidity, non-condensing LCD screen is operational from 14 131 °F. The sensor may still be programmed in colder temperatures, but with the remote control. ELECTRICAL Output: Relay 1 Relay 2 Electromechanical relay (potential and polarity free) Max. contact current: 1 A Max. contact voltage: 30 VAC Adjustable hold time: 0.5 9 s Solid-state relay (potential and polarity free) Max. contact current: 100 mA Max. contact voltage: 42 VDC / 30 VAC Test/Monitoring input: Sensitivity: Low: < 1 V High: > 10 V (max. 30 V) Response time on test request: typical < 5 ms Supply voltage: 12 24 VAC ±10% 12 30 VDC ±10% to be operated from SELV-compatible power supplies only Power consumption: < 2.5 W Noise: < 70 dB CAMERA Voltage regulator (built into wire harness): 6.6 36 VDC (±10%), 6 28 VAC (±10%) Operating temperature: -22 140 °F (max. RH: 95%) Video output: 1.0 (Vp-p) / 75 Image Sensor: CMOS Horizontal resolution: 480 TVL NTSC output: 720 (H) × 480 (V) Sync system: Inter-Sync Frame rate: 30 fps Minimum illumination: 0.01 LUX AE control: auto Gain control: auto Electronic shutter: 1 s ~ 1/10,000s S/N ratio: > 50 dB AWB: Auto PHYSICAL Degree of protection: IP54 COMPLIANCE FCC certification: FCC: G9B-100606 IC: 4680A-100606 Compliance: ISO 13849 PL «c» CAT. 2 (under the condition that the door control system monitors the sensor at least once per door cycle) Specifications are subject to change without prior notice. All values measured in specific conditions. 75.5816.13 IXIO-DT1 V 20240722 Page 3 of 16 HOW TO USE THE LCD DISPLAY DURING NORMAL FUNCTION Activation impulse Safety Negative display = active output FACTORY VALUE VS. SAVED VALUE displayed value = factory value To adjust contrast, push and turn the grey button simultaneously. During normal function only. displayed value = saved value NAVIGATING IN MENUS 1) Push to enter the LCD menu. 2) Enter password, if necessary. 3) Select language before entering the first LCD menu. Password XXXX Not during the first minute after power-on of the sensor. During the first 30 seconds after power-on of the sensor or later in the diagnostics menu. = scroll = select Select Back to return to previous menu or display. Select More to go to next level: - basic settings (MENU 1) - advanced settings (MENU 2) - diagnostics (MENU 3) CHANGING A ZIP CODE See application note on ZIP CODE (76.0024). 1) Navigate to menu 3 (Diagnostics). 2) Select "ZIP code". 3) Change the code as desired. ZIP code ID # ZIP code E24 1 56-KG4 01 0 800/02F To activate the new ZIP code, you must validate the last digit (see below): v = valid ZIP code (values will be changed accordingly) x = invalid ZIP code (no values will be changed) v/x = valid ZIP code, but from a different product ZIP code ... H24 1 56-KG4 01 0 800/02F ZIP code V *only available values will be changed* ZIP code E24 1 56-KG4 01 0 800/02F ZIP code E24 1 56-KG4 01 0 800/02F ZIP code H24 1 56-KG4 01 0 800/02F VALUE CHECK WITH REMOTE CONTROL Page 4 of 16 Pressing a parameter symbol on your remote control displays the saved value directly on the LCD screen. Additionally, the green LED will blink the number of times that the parameter is set to. Do not unlock first. Note: When querying FIELD SHAPE, the green LED will blink the number of times that it is set to, and then the green LED will blink either 1 time (narrow shape) or 2 times (wide shape). 75.5816.13 IXIO-DT1 V 20240722 1 MOUNTING & WIRING MOUNTING Using the provided mounting template, mount the sensor, ensuring that the bottom of the sensor is within 2 inches of the bottom of the door header. Refer to Application Note 76.0035 if an IXIO Spacer is required for the given application. Route the harness (20.5349) using the harness clip as shown in the exploded view of the mounting illustration. Mounting is compatible with the WIZARD. max. 2 in Sensor connectivity (power and relays) must utilize only the supplied harness. Sensor power and camera power must be supplied from a Class 2 supply source limited to 15 W. Sensor is intended to be monitored for proper operation by the door operator or system. Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness and/or IXIO sensor. DOOR CONTROL SENSOR WIRING RED BLACK BROWN BLUE WHITE (COM) YELLOW (N.C) GREEN (N.O.) PURPLE PURPLE POWER SUPPLY POWER SUPPLY SAFETY INPUT SAFETY INPUT OPENING INPUT OPENING INPUT OPENING INPUT TEST OUTPUT* TEST OUTPUT* CAMERA HARNESS FOR DT1 V Voltage Regulator VOLTAGE Power: 12 24 VAC, 50/60 Hz 12 30 VDC 2.5 W (max) Test: low: < 1 V high: > 10 V (30 V max.) response time: typ. < 5 ms * The sensor LED will briefly flash RED during monitoring communication with door control, indicating that external monitoring is functional. Monitoring functionality must be active on the sensor, door control, and monitoring wires must be properly connected to the door control. RCA VIDEO OUT (female) POWER 6 28 VAC ±10% 6.6 36 VDC ±10% 75.5816.13 IXIO-DT1 V 20240722 Page 5 of 16 2 RADAR OPENING IMPULSE FIELD green LED = motion detection The size of the detection field varies according to the mounting height of the sensor. The following graphics are representations not default settings. ANGLE 7.2 ft field size: 9 immunity: 2 from 15° to 45°, default 30 ° 7.2 ft from -15° to 15°, default 0° WIDTH 7.2 ft 13' x 6'6" (wide) 7.2 ft field size: 9 immunity: 2 or field size: 9 immunity: 2 field size: 9 or immunity: 2 6'6" x 8' (narrow) Page 6 of 16 1 × 1 grid is approximately 3.28 ft × 3.28 ft. 75.5816.13 IXIO-DT1 V 20240722 3 INFRARED SAFETY FIELD ANGLE red LED = presence detection Activate the visible spots to verify the position of the AIR curtain. Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains. OUR x2 The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 8 in. C1 = closest to sliding door C2 = farthest from sliding door DOOR C1 C2 If necessary, adjust the AIR curtain angle (from -7° to 4°, default 0°). CLOSER max. 3 in AWAY WIDTH Part of the detection field can be masked to reduce its width. The arrow position determines the width of the detection field. The size of the detection field varies according to the mounting height and the settings of the sensor. Wide setting has 1:1 ratio. For example, a 6-foot mounting height will project a 6-foot detection width at floor. Always verify the actual detection field width by walk-testing according to ANSI 156.10. 75.5816.13 IXIO-DT1 V 20240722 Additional adjustments are possible by LCD or remote control (see OVERVIEW OF SETTINGS). Page 7 of 16 4 SETUP Set up the sensor using either push-buttons or the remote control. STEP OUT OF THE INFRARED FIELD! SETUP 1 (QUICK) either hold the knob for 2 seconds, or use the remote control buttons as specified + 2 s SETUP 2 (ASSISTED) test of full door cycle + reference picture + either hold the knob for 4 seconds, or use the remote control buttons as specified 4 s + TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES! LED flashes red-green Page 8 of 16 75.5816.13 IXIO-DT1 V 20240722 OVERVIEW OF SETTINGS RC BUTTONS 01 23456789 Back More RAD: FIELDSIZE small > > > > > > > > large RAD: SHAPE LCD: "narrow" and "wide" setting options (default = wide) Remote Control: = wide, = narrow AIR: WIDTH see note 1 AIR: OUTPUT TEST More Back DeEner/NO Energ/NC NC NO Energ/NC DeEner/NO NC NO off on on+auto see note 2 see note 3 BASIC + + Back More RAD: FIELDSIZE small > > > > > RAD: IMMUNITY low > > > > RAD: DIRECTION off bi uni MTF RAD: HOLDTIME auto 1 s 2 s 3 s 4 s 5 s RAD: REENTRY small > > > > > RAD: OUTPUT DeEner/NO Energ/NC NC NO Energ/NC DeEner/NO NC NO AIR: IMMUNITY normal enhanced AIR: WIDTH > > > large > > > high uni + reentry see note 4 6 s 7 s 8 s 9 s see note 5 > > > large see note 2 mode B see note 1 ADVANCED AIR: NUMBER AIR: PRESENCE TIME AIR: FREQ 1 2 30 s 1 min 2 min 5 min 10 min 20 min 60 min infinte A B AIR: OUTPUT TEST REDIRECTION DeEner/NO Energ/NC NC NO Energ/NC DeEner/NO NC NO off on on+auto R1 MW R1MWorIR R2 IR R2 IR see note 2 see note 3 see note 6 FACTORY RESET full reset partial reset see note 7 Back More factory value ZIP CODE all parameter settings in zipped format (see application note on ZIP CODE 76.0024) ID # unique ID-number CONFIG P/N motion SOFT P/N (green) ERROR LOG last 10 errors + day indication AIR: SPOTVIEW view of spot(s) that trigger detection presence AIR: C1 ENERG signal amplitude received on curtain (red) AIR: C2 ENERG signal amplitude received on curtain 2 POWERSUPPLY supply voltage at power connector OPERATINGTIME power duration since first startup RESET LOG PASSWORD ADMIN delete all saved errors LCD and remote control password (0000= no password) enter code to access admin mode 75.5816.13 IXIO-DT1 V 20240722 Page 9 of 16 DIAGNOSTICS OVERVIEW OF SETTINGS (cont.) NOTES Note 1 Note 2 Note 3 Note 4 Note 5 Always use a screwdriver when making further AIR adjustments to the arrow position on the sensor. RADAR NO = normally open NC = normally closed AIR NO = normally open NC = normally closed DeEner = de-energized relay (active) Energ = energized relay (passive) The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control. MTF = uni-directional with motion-tracking feature uni + reentry: BEA recommends only adjusting using the LCD Auto mode evaluates traffic rate and adjusts hold time from 0.5 to 3 seconds Note 6 Note 7 REDIRECTION setting (F1 on remote control): R1-MW, R2-IR (F1=0): R1 = MW (i.e. motion detection) R2 = IR (i.e. presence detection) R1-MW or IR, R2-IR (F1=1): R1 = MW or IR (i.e. motion or presence detection) R2 = IR (i.e. presence detection) partial: outputs are not reset Page 10 of 16 75.5816.13 IXIO-DT1 V 20240722 LED SIGNALS COLORS (green) Motion detection (red) Presence detection BEHAVIORS LED flashes LED flashes quickly x LED flashes x times LED flashes red-green LED is off TROUBLESHOOTING E1: ORANGE LED flashes 1 1x E2: ORANGE LED flashes 2 2x The sensor signals an internal fault. The power supply voltage is too low/high. Replace sensor. Check power supply voltage in diagnotistics menu (menu 3) of the LCD. Check wiring. E4: ORANGE LED flashes The sensor does not receive 4 4x enough AIR energy. Decrease the angle of the AIR curtains. Increase the AIR immunity filter. Deactivate curtain #2 (C2, outer curtain). E5: ORANGE LED flashes The sensor receives too much 5 5x AIR energy. Slightly increase the angle of the AIR curtains. Decrease the AIR immunity filter. E8: ORANGE LED flashes 8 8x ORANGE LED is on RED LED flashes quickly after an assisted setup The sensor is disturbed by external elements. AIR power emitter is faulty. The sensor encounters a memory problem. The sensor sees the door during assisted setup. Eliminate the cause of disturbance (lamps, rain cover, door controller housing properly grounded). Replace sensor. Cut and restore power supply. If ORANGE LED illuminates again, replace the sensor. Move the AIR curtains away from the door. Install the sensor as close to the door as possible. If needed, use a bracket assembly. Ensure that the bottom of the sensor is mounted within 2" of the bottom of the door header. Launch a new assisted setup. RED LED illuminates sporadically The sensor vibrates. Check if the sensor is secure. Check position of cable and cover. The sensor sees the door. Adjust the AIR angle and launch an assisted setup. The sensor is disturbed by external conditions. Increase the AIR immunity filter. 75.5816.13 IXIO-DT1 V 20240722 Page 11 of 16 TROUBLESHOOTING (cont.) GREEN LED illuminates sporadically The sensor is disturbed by rain and/or leaves. Ghosting created by door movement. The sensor vibrates. The sensor sees the door or other moving objects. The LED and the LCD displays are off No power to sensor. The reaction of the door does not correspond with the LED signal Cannot access LCD menu or change parameters via remote control Sensor does not respond to remote control RED Visible External Monitoring (Test Indication LED) does not flash Incorrect output configuration / wiring. The sensor is protected by a password. Dead batteries. Monitoring installation/setup error. RED Visible External Monitoring (Test Indication LED) flashes continuously Door cycles open and remains open Sensor malfunction. Wiring issue. Door control not set correctly. Door control monitoring set to Active High. Safety and/or Motion output is set incorrectly. Increase radar immunity filter. Change radar field angle. Check if the sensor and door cover is secure. Check position of cable and cover. Remove the objects if possible. Change radar field size, angle, or immunity. Check wiring. Check for correct power supply. Check output configuration setting. Check wiring. Enter the correct password. If you forgot the code, cut and restore the power supply to access the sensor without entering a password during 1 minute. Replace batteries. Verify door control is capable of monitoring and the sensor monitoring wires are properly connected to the door control. Verify monitoring (TEST) is ON in the sensor settings. Replace the sensor. Verify wiring. Verify door control monitoring set to Active Low. Set door control monitoring to Active Low. Correctly set the given output required for the door control. Can't find your answer? Visit www.beainc.com or scan QR code for Frequently Asked Questions! Before contacting BEA Technical Support, locate the serial and CAN numbers of your sensor. SERIAL NUMBER view: back of sensor CAN NUMBER back view: top of sensor front Page 12 of 16 75.5816.13 IXIO-DT1 V 20240722 NOTES 75.5816.13 IXIO-DT1 V 20240722 Page 13 of 16 NOTES Page 14 of 16 75.5816.13 IXIO-DT1 V 20240722 ACCESSORIES AND REPLACEMENT PARTS ACCESSORIES 10IMB Mounting bracket adapter 10CDA Curved door accessory 10RETROFITSPACER 10MINIBRACKET Retrofit Spacer Kit Short, adjustable, (includes spacer, 2.5" mounting bracket harness, and 9" harness) 20.5302 Retrofit harness 10REMOTE BEA universal remote control REPLACEMENT PARTS 10.1279 Replacement cover (includes camera) 20.5349 Replacement harness 20.2009 Replacement camera harness 75.5816.13 IXIO-DT1 V 20240722 Page 15 of 16 ©BEA | Original Instructions | PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOR PRINTING Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 General Tech Questions: techservices-us@BEAsensors.com | www.BEAsensors.com Page 16 of 16 75.5816.13 IXIO-DT1 V 20240722