User Guide for GOODWE models including: GW5KL-ET, GW5KL-ET Residential Smart Inverter Solutions, Residential Smart Inverter Solutions, Smart Inverter Solutions, Inverter Solutions

Visualizar

Produtos-GOODWE

Residential Smart Inverter Solutions Quick Guide (ET 5-10kW Lynx Home F ...

1 Residential Smart Inverter Solutions Quick Guide (ET 5-10kW Lynx Home F) V1.0-2024-04-30 Device Model Description Inverter GW5KL-ET GW6KL-ET GW8KL-ET GW10KL-ET


File Info : application/pdf, 5 Pages, 4.59MB

PDF preview unavailable. Download the PDF instead.

GW Residential-Smart-Inverter-Solutions Quick-Guide-ET-5-10K-LXF-EN
Residential Smart Inverter Solutions Quick Guide (ET 5-10kW+Lynx Home F)

V1.0-2024-04-30

WARNING The information in this quick guide is subject to change due to product updates or other reasons. This guide cannot replace the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions in the manual are for guidance only.
01 Networking

Device

Model

Description

GW5KL-ET GW5K-ET

GW6KL-ET GW6.5K-ET

GW8KL-ET GW8K-ET

Inverter

GW10KL-ET GW10K-ET GW5KN-ET

-

GW6.5KN-ET

GW8KN-ET

GW10KN-ET

Battery system

Lynx Home F (G2) LX F9.6-H-20 LX F12.8-H-20 LX F16.0-H-20 LX F19.2-H-20 LX F22.4-H-20 LX F25.6-H-20

Lynx Home F ,F Plus LX F6.6-H LX F9.8-H LX F13.1-H LX F16.4-H

· A maximum of 8 battery systems can be clustered in a system. · Do not mix connect battery systems of different versions.

Smart meter GM3000

GM3000: GM3000 and the CT, which cannot be replaced, are included in the inverter package. CT ratio: 120A/40mA.

Communicati- · Wi-Fi Kit

on module

· 4G Kit-EC or 4G Kit-AU

-

02 Power On/Off

Power on/off

1

2

3

4

5

 : Install or not based on local laws and regulations

1

03 Installations 2

04 Wiring Diagram
ET 5-10kWsingle+ Lynx Home F + GM3000
3

Battery System Wiring Diagram

05 Equipment Commissioning

SolarGo APP Download and open the APP, follow the prompts to connect the device.

SEMS Portal app

Quick Settings

Click SolarGo APP Home>Settings>Quick Settings to complete quick settings step by step. Installer password: goodwe2010

Setting the Safety Code

Setting the BAT Connect Mode

1

2

Setting the Working Mode Setting the Advanced Parameters Tap Home > Settings > Advanced Settings to set the following functions. Setting the Power Limit Function
The function is disabled by default,if you need DRED/Remote Shutdown/RCR function, enable it.
Enable Three-phase Unbalanced Output when the utility grid company adopts phase separate billing.
4

Configuring the Network

Tap Home > Settings > Communication Setting > Network Settings to set network

parameters.

WiFi Kit

4G Kit-EC or 4G Kit-AU

After configuring the APN, unplug the Bluetooth module and insert the 4G Kit EC or 4G Kit AU module.

Creating a Power Plant Create power plants and add equipments via SEMS Portal app.
Enter the plant information based on actual situation.

Scan the QR code to add a new equipment.

2
Add a new equipment
1
5

GoodWe Technologies Co., Ltd. No. 90 Zijin Rd., New District,
Suzhou, 215011, China www.goodwe.com
service@goodwe.com



References