LED Indicator/Button/Ports
LED Indicator
LED Indicator | Description |
---|---|
Blinking white | The AP is starting up. |
Solid white | The AP has completed startup and is waiting to be managed by a controller (such as IP-COM ProFi Software Controller, ProFi App/ProFi Cloud web UI, an AP controller (AC), or a router with AP management function). |
Solid blue | The AP is managed by a controller and is working properly. |
Fast blinking blue | The AP Locate feature was activated in the ProFi Software Controller or ProFi Cloud. |
Slowly blinking blue | The AP is isolated and no longer provides wireless access (due to disconnection from the uplink network). |
Alternating white / blue | The AP is busy (for example, upgrading firmware). Do not disconnect the power. |
Button/Ports
Button/Ports | Description |
---|---|
RESET | Reset button, used to reset the AP. For the reset method, see Q4 in FAQ. |
LAN1 (for Pro-6-LR) | 10/100/1000 Mbps auto-negotiation. Connected to a wired device (such as a computer) to transmit data. |
LAN0/PoE or LAN/POE | 10/100/1000 Mbps auto-negotiation port for both PoE power supply and data transmission. Generally connected to an upstream device (such as a PoE switch). You can power the AP by: - The included PoE adapter or power adapter. - Other PoE power supply devices with IEEE 802.3af/at standards. |
Cable Fix Notch | Used to fix Ethernet cables to the AP. |
Network Topology
The typical network topology of the APs is shown below.
Diagram Description: A network diagram illustrating the connection of IP-COM APs. It shows an IP-COM AP Controller, a PoE Switch, a Router, and a Management Computer (running ProFi Software Controller) connected to the network. An Access Point (AP) is connected to the PoE Switch. The network also connects to the WAN and a cloud service (SDN Cloud). Remote access is shown from a Laptop and a Smartphone to the ProFi Software Controller and ProFi App/ProFi Cloud respectively.
Package Contents
- AP x 1
- Power Adapter x 1 + PoE Injector x 1
- Mounting Bracket (on AP for Pro-6-LR) x 1
- Plastic Anchor (height: 6.6 mm, inner diameter: 2.4 mm, length: 26.4mm) x 3
- Plastic Nut (length: 14.5 mm, diameter: 2.51 mm) x 3
- Screw (head diameter: 6 mm, thread diameter: 3 mm, length: 25 mm) x 3
- Quick Installation Guide
Install the AP
Tips:
- Before installation, record the MAC address (on the label of the AP) and installation position of the AP to locate the AP through the MAC address.
- Prepare a marker, a hammer drill, a drill bit, a rubber hammer, a screwdriver, and a ladder.
- The APs are suitable for mounting at heights greater than 2 meters.
Installation Steps:
- (For Pro-6-LR) Remove the mounting bracket from the AP.
- Position the bracket on the ceiling and mark screw hole positions with a marker.
- Drill holes in the marked positions using a hammer drill.
- Option A (for general ceilings): Knock the included plastic anchors into the holes using a rubber hammer. Insert the included screws into the screw holes on the bracket and fix them into the plastic anchors using a screwdriver to secure the bracket.
- Option B (for ceilings with weak strength, e.g., plasterboard): Insert the included screws into the screw holes on the bracket and fix them into the included plastic nuts using a screwdriver to secure the bracket.
- Align the slots of the AP with the hooks of the bracket.
- Ensure that the AP is firmly seated onto the bracket. Turn the AP clockwise until it is fixed securely onto the bracket.
Diagram Description for Installation: The diagrams show the process of attaching the mounting bracket to the ceiling and then attaching the AP to the bracket. It illustrates marking holes, drilling, using anchors and screws (Options A and B), and finally twisting the AP onto the bracket hooks.
Power the AP
CAT5e or better Ethernet cables are recommended.
Method 1: Power the AP with the included PoE adapter and PoE injector
- Use an Ethernet cable to connect the LANO/PoE or LAN/PoE port of the AP to the PoE port of the included PoE injector.
- Use the included power adapter to connect the PoE injector to a power socket.
Tips: For Pro-6-Lite, the maximum power supply distance is 100 meters; for Pro-6-LR, the maximum power supply distance is 50 meters.
Method 2: Power the AP with a standard PoE power supply device
Use an Ethernet cable to connect the LANO/PoE or LAN/PoE port of the AP to a PoE power supply device with 802.3af/at standards. A PoE switch is used for illustration.
Diagram Description for Powering AP: The diagrams illustrate two methods of powering the AP. Method 1 shows the AP connected via Ethernet cable to a PoE injector, which is then connected to a power adapter and a power socket. Method 2 shows the AP connected via Ethernet cable to a PoE port on a PoE switch.
Configure the AP
Method 1: Through IP-COM ProFi Software Controller
1. Download and install the IP-COM ProFi Software Controller on your management computer.
2. Connect the AP to the network. The AP will be discovered by the controller.
3. Manage the AP through the controller interface.
Method 2: Through ProFi App / ProFi Cloud
1. Download the ProFi App.
2. Scan the QR code to get support and services. [QR code for website]
3. Follow the instructions in the app to configure the AP.
FAQ
- Q: How to reset the AP?
A: For the reset method, see Q4 in FAQ. - Q: How to install the AP?
A: Refer to the "Install the AP" section. - Q: How to power the AP?
A: Refer to the "Power the AP" section. - Q: How to reset the AP?
A: Press and hold the RESET button for 5-10 seconds until the LED indicator blinks white, then release. The AP will reboot and reset to factory defaults. - Q: How to get support and services?
A: Scan the QR code for website access. [QR code for website]
Safety Precautions
Please read the following safety precautions carefully before installation and operation:
- Only qualified personnel should be allowed to install and operate the device.
- Ensure the device is installed in a well-ventilated area.
- Avoid installing the device near heat sources or in direct sunlight.
- Do not expose the device to water or moisture.
- Use only the power adapter and accessories provided by the manufacturer.
- Do not attempt to open or repair the device yourself.
- Ensure proper grounding of the device.
- Follow all local electrical codes and regulations.
- Keep the device away from flammable materials.
- Do not operate the device in environments with explosive gases.
Regulatory Information
CE Compliance: This device complies with the essential requirements and other relevant provisions of Directive 2014/53/EU.
FCC Compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
UKCA Compliance: This device complies with the essential requirements and other relevant provisions of the Radio Equipment Regulations 2017.
Technical Support: For technical support, please visit the IP-COM website or contact your local distributor.
Copyright: © 2023 IP-COM. All rights reserved.