Installation Guide for Altronix models including: Trove2BH2, TBH2, TBHD2, Access and Power Integration Kit

Click to View

Altronix TROVE2BH2 | Altronix/BOSCH Access and Power Integra


File Info : application/pdf, 8 Pages, 430.28KB

PDF preview unavailable. Download the PDF instead.

Altronix TBH2 Backplane Installation Instructions
Access & Power Integration

SIGNALING

Trove2BH2
- Trove2 enclosure with Altronix/Bosch backplane (TBH2)
TBH2
- Altronix/Bosch backplane only
TBHD2
- Bosch door backplane only
Installation Guide

All registered trademarks are property of their respective owners.

More than just power.TM

Rev. TBH110419 Installing Company: _________________________ Service Rep. Name: __________________________________________

Address: _________________________________________________________ Phone #: _________________________

Overview: Trove2BH2 accommodates various combinations of Bosch boards with or without Altronix accessories for access control systems.

Agency Listings: · UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
* Stand-by Power Level I if no battery is supplied. · This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada. · CE European Conformity.

Specifications: · 16 Gauge backplane and enclosure with ample knockouts for convenient access.
Trove2BH2
Trove2 enclosure with TBH2 Altronix/Bosch backplane · Includes: tamper switch, cam lock, and mounting hardware.
Enclosure Dimensions (H x W x D): 27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm).
TBH2
Altronix/Bosch backplane only · Includes mounting hardware.
Dimensions (H x W x D): 25.375" x 19.375" x 0.3125" (644.5mm x 482.6mm x 7.9mm).
TBH2 accommodates a combination of the following: Altronix Modules: · Two (2) MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), PD16W(CB), VR6. Bosch Modules: · One (1) B520 power supply. · One (1) D7412GV4, D9412GV4, B8512G, B9512G controller. · Up to six (6) B299, B308, B426, B450, B901, D125B, D129, D185, D192G, D8128D, D8129, D8130, ICP-SDI-9114 · Up to ten (10) B208, B600, B800, D132A, D8125/MUX
TBHD2
Bosch door backplane only · Fits Altronix Trove2 enclosure.
Dimensions (H x W x D): 23.75" x 18.125" x 0.3125" (603.3mm x 460.4mm x 7.9mm).
TBHD2 accommodates a combination of the following: BoschModules: · One (1) D7412GV4, D9412GV4, B8512G, B9512G controller. · Up to eleven (6) B208, B299, B308, B426, B450, B600, B901, D125B, D129, D132A, D185, D192G, D8125/MUX, D8128D,
D8129, D8130, ICP-SDI-9114.

Installation Instructions for Trove2:

1. Remove backplane from enclosure prior to mounting (do not discard hardware).

2. Mark and predrill holes in the wall to line up with the top keyholes in the enclosure. Install the upper fasteners and screws in the wall

with the screw heads protruding. Place the enclosure's upper keyholes over the screws; level and secure. Mark the position of the

lower holes. Remove the enclosure. Drill the lower holes and install the fasteners.

Place the enclosure's upper keyholes over the upper screws. Install the lower screws and make sure to tighten all screws

(Enclosure Dimensions, pg. 4).

3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the

Fig. 1

enclosure approximately 2" from the right side (Fig. 1, pg. 1).

Connect tamper switch wiring to the Access Control Panel input or the appropriate

Enclosure

UL Listed reporting device. To activate alarm signal open the door of the enclosure.

Edge of Enclosure

4. Mount Altronix/Bosch boards to backplane, refer to pages 3-5.

Tamper Switch (provided)

To Access Control Panel or UL Listed Reporting Device

- 2 -

Trove2BH2 Installation Guide

Installation Instructions for Altronix Sub-Assemblies to TBH2: 1. Insert screw (provided) into hole configuration (A) from the backside of backplane (Fig. 2a, pg. 3).
Screw spacer onto screws, repeat for additional three (3) board mounting holes. 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 2a, pg. 3).

Altronix Sub-Assemblies Position Chart:

Backplane

Altronix Board

Pem Mounting

Altronix PD16W(CB) Sub-Assembly

A

Fig. 2

Pan Head Screw

Fig. 2a
Pan Head Screw (through backplane) Spacer Altronix Sub-Assembly

A

A

Trove2BH2 Installation Guide

- 3 -

Installation Instructions for Bosch Boards to TBH2: Mounting Bosch B520 Power Supply: 1. Fasten spacers (provided) into hole configuration (A) of backplane (Fig. 3, pg. 4). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 3a, pg. 4). Mounting Bosch B8512G/B9512G IP Control Panels: 1. Fasten lock nuts onto top two (2) pems, leaving enough space to accommodate B8512G/B9512G. 2. Slide top mounting holes of B8512G/B9512G over pems of backplane configuration (B) (Fig. 3, pg. 4). 3. Fasten 5/16" pan head screw (provided) through mounting hole of B8512G/B9512G. Mounting Bosch Modules: 1. Utilize mounting bracket to mount Bosch modules to the backplane configurations (C) (Fig. 3, pg. 4).

Bosch Board Position Chart:

Bosch Board(s)

Power Supply

B520

Controllers

D7412GV4, D9412GV4, B8512G, B9512G

Access Control*

B901

Expansion Modules* B299, B600, D8128D, D8125/MUX, D8129

Interface Cards*

D125B, D129, D132A, D185, D192G, D8130

SDI/2 Devices*

B208, B308, B426, B450, ICP-SDI-9114

Mounting A B
C

Backplane
Pan Head Screw

Fig. 3a
Pem Spacer Bosch Sub-Assembly

Fig. 3

B A

C

C

C

C

C

C

C

C

- 4 -

C

C

* These boards have the same keyhole

mounting bracket (Fig. 3, pg. 4). Position

them according to your specific design.

Trove2BH2 Installation Guide

Installation Instructions for Bosch Boards to TBHD2: Mounting Bosch B8512G/B9512G IP Control Panels: 1. Fasten lock nuts onto top two (2) pems, leaving enough space to accommodate B8512G/B9512G. 2. Slide top mounting holes of B8512G/B9512G over pems of backplane configuration (B) (Fig. 4, pg. 5). 3. Fasten 5/16" pan head screw (provided) through mounting hole of B8512G/B9512G. Mounting Bosch Modules: 1. Utilize mounting bracket to mount Bosch modules to the backplane configurations (B) (Fig. 3, pg. 3).

Bosch Board Position Chart:

Bosch Board(s)

Access Control*

B901

Expansion Modules*

B299, B600, D8128D, D8125/MUX, D8129

Interface Cards*

D125B, D129, D132A, D185, D192G, D8130

SDI/2 Devices*

B208, B308, B426, B450, ICP-SDI-9114

Controllers

D7412GV4, D9412GV4, B8512G, B9512G

Mounting A B

Fig. 4

A

A

A

A

A

A

A

A

A

B

A

A

Trove2BH2 Installation Guide

- 5 -

0.45" (11.4mm)

TBH2 Dimensions 25.375" x 19.375" x 0.3125" (644.5mm x 482.6mm x 7.9mm).

2.2" (55.9mm)

19.375" (492.1mm)

2.2" (55.9mm)

0.156" ( 3.96mm)

25.375" (644.6mm)

8.5" (215.9mm) 12.625" (320.7mm) 16.25" (412.8mm)

0.45" (11.4mm)

1.0" (25.4mm)
7.5" (190.5mm) 9.2" (233.7mm)

1.0" (25.4mm) 7.5" (190.5mm) 9.2" (233.7mm)

- 6 -

Trove2BH2 Installation Guide

TBHD2 Dimensions 23.75" x 18.125" x 0.3125" (603.3mm x 460.3mm x 7.9mm).
18.125" (460.3mm) 13.7" (350mm)

7.4" (188mm)

8" (203.2mm)

23.75" (603.3mm) 2.075" (52.7mm)

0.156" ( 4mm) 0.45" (11.4mm)

8.7" (221mm)

11.8" (299.7mm)

8.7" (221mm)

10.82" (274.8mm)

7.85" (199.4mm) 7.5" (190.5mm)

13.7" (350mm)

Trove2BH2 Installation Guide

- 7 -

Trove2 Enclosure Dimensions (H x W x D approximate): 27.25" x 21.75" x 6.5" (692.15mm x 552.5mm x 165.1mm)

2.00" (50.8mm)

21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm)

2.00" (50.8mm)

6.25" (158.8mm)

1.25" (31.8mm)

6.25" (158.8mm) 1.25" (31.8mm)

1.5" (38.1mm)

0.5625" (14.3mm)

0.685" (17.4mm)

1.77" (45mm)

Knockouts 1.125" (28.3mm)

2.415" (61.3mm) 0.885" (22.5mm)

19.80" (502.9mm)

2.00" (50.8mm)

6.75" (171.5mm)

8.25" (209.5mm)

27" (685.8mm)

8.00" (203.2mm)

1.00" (25.4mm)

0.85" (21.6mm)

1.25" (31.8mm)

2.00" (50.8mm)

2.00" (50.8mm)

5.25" (133.4mm)

7.00" (177.8mm)

5.25" (133.4mm)

1.25" (31.8mm) 2.00" (50.8mm)

Altronix is not responsible for any typographical errors. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A.

IITrove2BH2

I24U

MEMBER

- 8 -

Trove2BH2 Installation Guide



References