User Manual for COOLON models including: Signal Lighting System, Signal, Lighting System, System
18 mag 2022 — Fully Lock the 2 pole mount brackets in position by tightening the 4x nylock nuts. Measure distance from the top of the pole. Ensure the angles are parrallel.
TO LUMINAIRE SIGNAL LIGHTING SYSTEM MANUAL EDITION 1.0 Page 3 / 3 support@coolon.com.au • aus. 1300 287 533 • intl. 613 8681 3633 • www.coolon.com.au Page 3 / 3 As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field.
File Info : application/pdf, 3 Pages, 1.38MB
DocumentDocumentSIGNAL LIGHTING SYSTEM MANUAL EDITION 1.0 Technical Specifications (per Luminaire) SUPPLY VOLTAGE 48VDC ± 10% POWER 40W OPERATING TEMP. 0°C Tamb 50°C IP RATING IP66 IK RATING IK09 INSTALLATION INSTRUCTIONS Step 1 Tighten the 4x nuts to secure the threaded rods to the pole-clamp sub-assembly. Ensure inner distance between rods are: · TOP CLAMP: 163mm · BOTTOM CLAMP: 163mm Page 1 / 3 TIGHTEN FIXED NUT Do not tighten 568mm FACTORY ADJUSTED Do not move. Step 2 Fully Lock the 2 pole mount brackets in position by tightening the 4x nylock nuts. Measure distance from the top of the pole. Ensure the angles are parrallel. The system must not rotate or slide. TIGHTEN ANGLES IN PARALLEL 1,555mm The max. allowed distance from the pole top to the bottom clamp is 2,600mm approximately. At this position the distance A/F is 175mm (Max. allowed by the clamp). www.coolon.com.au support@coolon.com.au · aus. 1300 287 533 · intl. +613 8681 3633 · www.coolon.com.au As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field. The Coolon team is working hard to ensure optimal product operation and the safety of all users, please check our website periodically to ensure you are up to date with the latest information. Product must be installed by a suitably qualified person. All documentation is subject to change without notice. Page 1 / 3 SIGNAL LIGHTING SYSTEM MANUAL EDITION 1.0 Page 2 / 3 INSTALLATION INSTRUCTIONS - LIGHT ADJUSTMENT Light Adjustment Angle of the fittings are factory adjusted to achieve 360° of coverage. Do not move unless required. See below for adjustment instructions. Step 4 Loosen indicated nuts enough to allow rotation of the clamps. 20° 20° 160° 90° 160° 70° 70° Step 5 Rotate light into desired position. Tighten nuts after adjustment to complete installation. LOOSEN NUT TIGHTEN NUT LOOSEN NUT TIGHTEN NUT Step 6 If additional rotation is required, the light tube can also be rotated. Loosen the nuts of the upper clamp and screws on the bottom cup enough to allow rotation of the light tube. Step 7 Rotate light into desired position. Tighten screws on bottom cup first then, tighten nuts of the upper clamp until it meets the stoppers to complete installation. LOOSEN NUTS TIGHTEN NUTS LOOSEN SCREWS TIGHTEN SCREWS www.coolon.com.au support@coolon.com.au · aus. 1300 287 533 · intl. +613 8681 3633 · www.coolon.com.au As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field. The Coolon team is working hard to ensure optimal product operation and the safety of all users, please check our website periodically to ensure you are up to date with the latest information. Product must be installed by a suitably qualified person. All documentation is subject to change without notice. Page 2 / 3 SIGNAL LIGHTING SYSTEM MANUAL EDITION 1.0 INSTALLATION INSTRUCTIONS - WIRING Step 8 Wire the lights and power supply into the junction box. Repeat for each junction box. Loom and cable tie as required. TO LUMINAIRE Page 3 / 3 TO LUMINAIRE Step 9 Wire mains input and luminaire out cables into the power supply. FROM POWER SUPPLY 240VAC MAINS INPUT 0V +48V E 0V N A +48V A +48V N Factory Wired DO NOT TOUCH +48V E 0V OUTPUT TO JUNCTION BOX (X2) One cable per Junction Box IMPORTANT Primary use: commercial and industrial applications. · Read through this manual before installation · Handle the product with care · Class I products must be grounded · The product must be installed by a suitably qualified person · Do not stare at operating lamp, may be harmful to the eyes · Turn OFF the power before installation and maintenance · Make sure the product is securely installed · The housing might become hot after operation · Keep optical face clean www.coolon.com.au support@coolon.com.au · aus. 1300 287 533 · intl. +613 8681 3633 · www.coolon.com.au As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field. The Coolon team is working hard to ensure optimal product operation and the safety of all users, please check our website periodically to ensure you are up to date with the latest information. Product must be installed by a suitably qualified person. All documentation is subject to change without notice. Page 3 / 3