Lofrans' Windlass Wiring Diagram
This document outlines the electrical connections for a Lofrans' windlass system.
System Components and Connections
The diagram features the Lofrans' logo at the top left.
Two footswitches are shown, labeled 'DOWN' and 'UP'.
A Black wire connects to the 'DOWN' footswitch.
A Green wire connects to the 'UP' footswitch.
Details for the Rocket Switch Type C are provided:
- Pin 8: Black connector
- Pin 2: Battery +
- Pin 3: Green Connector
A control unit is depicted with terminals labeled M1, B+, B-, and M2.
A Black wire connects to the windlass motor and the control unit.
A Red wire connects the windlass motor to the control unit's B+ terminal.
A Green wire connects from the footswitches to the control unit.
A Black connector is shown on the control unit.
A Green connector is also shown on the control unit.
A fuse labeled 'Fuse 5 A' is included in the circuit.
A Grey wire connects the fuse to the battery negative terminal.
A battery is shown with positive (+) and negative (-) terminals.
The positive terminal of the battery connects to the control unit.
The negative terminal of the battery connects to the fuse.
The windlass motor is depicted at the top right of the diagram, connected to the control unit via Black and Red wires.