Lennox EL297DFE(K) Elite Series Gas Furnace
Product Specifications (EHB)
Overview
The Lennox EL297DFE(K) Elite Series Gas Furnace is a residential downflow furnace featuring two-stage heating, a constant torque blower, and refrigerant detection capabilities. It offers an AFUE of 97% and is designed for efficient operation.
Key Features:
- Input: 44,000 to 110,000 Btuh
- Nominal Add-on Cooling: 1.5 to 5 Tons
- High Efficiency Constant Torque Blower Motor
- Refrigerant Detection-Ready
- Two-Stage Heat
Model Number Identification
The model number EL 2 97 DF 070 X E 36 BK provides specific details about the unit:
- Unit Type: EL = Elite® Series
- Stages: 2 = Two-Stage
- AFUE: 97 = 97%
- Configuration: DF = Downflow
- Nominal Gas Heat Input: 045 (44,000 Btuh), 070 (66,000 Btuh), 090 (88,000 Btuh), 110 (110,000 Btuh)
- Nominal Add-On Cooling Capacity: 36 (1.5-3 tons), 48 (2.5-4 tons), 60 (3-5 tons)
- Blower: E = High Efficiency Constant Torque Blower Motor
- Low NOx: X = Units meet California Nitrogen Oxides Standard (40 ng/J)
- Refrigerant Detection: K = Refrigerant Detection-Ready
- Cabinet Width: B = 17-1/2 in., C = 21 in.
Feature Highlights
The furnace incorporates several advanced features for performance and efficiency:
- Lennox Duralok Plus™ Heat Exchanger
- Secondary Heat Exchanger
- Inshot Burners
- Two-Stage Gas Control Valve
- Two-Speed Combustion Air Inducer
- SureLight® Integrated Furnace Control
- Variable Speed Direct Drive Blower
- Insulated Cabinet
- Safety Interlock Switch
- Gas Piping And Electrical Inlets
Approvals and Warranty
The unit is AHRI Certified, CSA International Certified, and tested according to US DOE procedures. It is approved for installations from 0 - 4500 ft. and meets ENERGY STAR® certification standards. The warranty includes a limited lifetime warranty for the Duralok Plus™ Aluminized Steel Heat Exchanger in residential applications and limited ten years in non-residential applications. All other components have a limited five-year warranty in residential installations and a limited one-year warranty in non-residential installations. For detailed warranty information, refer to the Lennox Basic Limited Warranty at www.Lennox.com.
California Specifics: Furnaces may not meet South Coast Air Quality Management District (SCAQMD) Rule 1111 and San Joaquin Valley Air Pollution Control District (SJVAPCD) Rule 4905 NOx emission limits in certain areas. However, they are approved by the California Energy Commission and meet California Nitrogen Oxides Standard (NOx) limits of 40 ng/J.
Applications
- Input capacities of 44,000, 66,000, 88,000, and 110,000 Btuh.
- Energy efficiency (AFUE) up to 97%.
- Compact cabinet design for downflow applications.
- Compatible with Lennox add-on indoor coils, air cleaners, and humidifiers.
- Shipped factory assembled with controls installed and wired.
- Each unit is factory test operated.
Heating System Details
- Lennox Duralok Plus™ Heat Exchanger Assembly: Features a primary heat exchanger and secondary condenser coil assembly with a multi-pass crimped seam design, constructed of heavy-gauge, aluminized steel for efficient expansion and contraction.
- Secondary Heat Exchanger: Constructed of aluminum fins fitted to stainless steel tubes, factory tested for leaks, and includes a condensate drain header box.
Features - Heating System Continued
- Lennox Designed Flue Condensate Trap Assembly: For field installation outside the conditioned air stream, allowing for easy cleaning and winterizing.
- Inshot Burners: Aluminized steel burners provide efficient, trouble-free operation, mixing air and gas for proper combustion. The assembly can be removed as a single component for service.
- SureLight® Hot Surface Ignitor: Offers tough, reliable, long-life performance with a silicon nitride ignitor protected by a steatite block.
- Two-Stage Gas Control Valve: A 24-volt redundant combination control for manual shut-off, automatic electric valve, and gas pressure regulation.
- Two-Speed Combustion Air Inducer: A permanent split capacitor (PSC) heavy-duty blower that prepurges the heat exchanger and safely vents flue products. It operates only during the heating cycle and uses dual pressure switches to prove blower operation.
- Flame Rollout Switches (2): Factory installed on the burner box for protection against abnormal operating conditions, featuring manual reset.
- Limit Control: Primary limit is accurately located on the vestibule panel with automatic reset.
Optional Accessories
- High Altitude Orifice Kits: Required for proper operation at altitudes from 7501 to 10,000 ft. Available for natural gas and LPG/propane.
- High Altitude Pressure Switch Kit: Required for proper operation on installations above 4500 ft.
- Natural Gas to LPG/Propane Conversion Kit: For field changeover from natural gas to LPG/Propane.
- LPG/Propane to Natural Gas Conversion Kit: For field changeover from LPG/Propane to natural gas.
Direct Vent / Non-Direct Vent Sealed Combustion System
The furnace features a sealed combustion system, allowing installation in either Direct Vent or Non-Direct applications. In Direct Vent, combustion air is supplied from outdoors and flue gases are discharged outdoors. In Non-Direct Vent, combustion air is supplied from indoors and flue gases are discharged outdoors. Lennox has approved specific venting systems as alternatives to PVC vent pipe.
- Flue Coupling: Assists with exhaust flue piping connection and servicing.
- Termination Kits: Facilitate installation of combustion air intake pipe and flue exhaust pipe. Various kits are available for different venting configurations (Concentric, Flush-Mount, Wall-Close Couple).
Controls
- SureLight® Integrated Furnace Control: Manages all furnace operations, including pre-purge and post-purge cycles, and safety controls like flame rectification. It includes a watchguard circuit and supports optimal performance with a high-quality, digital two-stage thermostat.
- Furnace Input Staging Options: Two-Stage (Conventional) determined by thermostat demand; Single-Stage (Conventional) with factory settings for 2nd-stage heat ON delay.
- Display LED: Provides alpha-numeric information for diagnostics and system status. Diagnostic codes are stored in non-volatile memory.
- DIP Switch Settings: Allow selection of thermostat type (Single-Stage or Two-Stage) and adjustment of blower on/off times for heating and cooling, heating/cooling speeds, and dehumidification settings.
- Dual-Fuel Operation: A jumper enables operation with a single or two-stage heat pump.
- Two-Stage Compressor Operation: A jumper enables operation with a two-stage compressor.
- Accessory Terminal: Provides power for accessories like air cleaners and humidifier connections.
- 24 Volt Transformer (40VA): Furnished and factory installed.
- Field Wiring Make-up Box: Furnished for line voltage wiring.
- Refrigeration Detection System (RDS): Complies with UL 60335-2-40 and is required for systems using R-454B refrigerant. It stops compressor/heating operation and runs the blower if R-454B refrigerant is detected to reduce concentrations.
Optional Accessories - Controls
- E30 Smart Wi-Fi Thermostat: A Wi-Fi enabled, electronic 7-day, multi-stage, programmable touchscreen thermostat with advanced features like auto-changeover, dehumidification control, and remote monitoring.
- Remote Outdoor Temperature Sensor: Used with the E30 Smart Thermostat to display outdoor temperature.
- Thermostat: Not furnished with the unit; refer to Lennox Price Book for selection.
- Furnace Twinning Panel: Required to operate two identical furnaces simultaneously from a single thermostat.
- Transformer (75VA): Recommended for zoning or defrost thermostats and other 24V accessories requiring higher VA rating.
- Blower Relay Kit: For use with two-stage outdoor units to allow furnace blower speed changes.
Features - Blower
- Direct drive blower: Statically and dynamically balanced, resiliently mounted for easy servicing.
- Power Saver™ Constant Torque Blower Motor: A DC Brushless Motor (ECM) programmed for constant torque at selectable speeds, controlled by the SureLight® Integrated Furnace Control. Blower speeds are easily changed via the control.
Features - Cabinet
- Low-profile, narrow width: Allows for easy installation.
- Heavy-gauge, cold rolled steel construction: With a pre-painted cabinet finish.
- Sealed blower compartment: Features an inner blower compartment access panel to prevent air leakage.
- Cabinet door: Removable without tools for complete service access.
- Safety interlock switch: Automatically shuts off power when the blower compartment access door is removed.
- Gas piping and electrical inlets: Provided on both sides of the cabinet.
Coil Match-Up
Lennox downflow indoor coils physically match the furnace supply air opening with the same letter designation as found in the furnace model number.
Low Leakage Cabinet
All models have less than 2% air leakage and meet ANSI/ASHRAE Standard 193-2010.
Optional Accessories - Filter
- Downflow Filter Cabinet: Mounts directly on top of the furnace and accommodates two filters. Filter rails and front access for servicing are included. Cleanable filter(s) are furnished.
Specifications
Detailed specifications are provided for various models, including Gas Heating Performance (AFUE, Input/Output Btuh, Temperature Rise, Gas Manifold Pressure), High Static, Connections (Intake/Exhaust Pipe, Gas Pipe Size, Condensate Drain Trap), Indoor Blower (Wheel Diameter, Motor Type/Output, Tons of Add-on Cooling, Air Volume Range), and Electrical Data (Voltage, Blower Motor Full Load Amps, Maximum Overcurrent Protection). Shipping Data (lbs.) is also included.
Installation Clearances
Required clearances are provided for Sides, Rear, Top/Plenum, Front, Front (service/alcove), and Floor. The unit can be installed on combustible floors with the optional Downflow Combustible Flooring Base.
Vent Lengths
Extensive tables provide vent lengths for various termination types (Standard, Concentric) at different elevations (0-4500 ft. and 4501-10,000 ft.) and pipe sizes. Additional tables detail vent lengths for exhaust using ventilated attic/crawlspace intake air.
Gas Heat Accessories
Accessories such as High Altitude Pressure Switch Kits, Natural Gas to LPG/Propane Conversion Kits, and High Altitude Orifice Kits are available for specific installation requirements.
Refrigerant Detection System (RDS) Components
Information on the RDS Coil Sensor Kit and Communicating Blower Control Board is provided, noting compatibility with Lennox® Communicating Furnaces and non-communicating 24V furnaces.
High Altitude Derate
Units installed at altitudes above 4501 ft. require pressure switch and/or orifice changes as detailed in the Gas Heat Accessories table. The provided derate is the only permissible one for these units.
Dimensions
Detailed diagrams and tables illustrate the unit dimensions, including Front View, Top View, and Side View. Furnace/Coil Combined Dimensions are also provided for various models.
Optional Accessories - Venting
Various venting accessories are described and illustrated, including Flush-Mount Vent Termination Kits, Concentric Wall and Roof Termination Kits, and Wall Termination Kits for grade clearance. These kits facilitate proper and safe venting of combustion byproducts.
Blower Data
Comprehensive blower data tables provide Air Volume (cfm) and Watts at various external static pressures and blower speeds for each model, allowing for precise performance analysis.
Revisions
A new section for IAQ Products has been added.