Instruction Manual for HANNA instruments models including: HI9810322, Wireless pH Tester for Cheese with Built-In Specialized Electrode, HI9810322 Wireless pH Tester for Cheese with Built-In Specialized Electrode, Built-In Specialized Electrode, HI9810322 Wireless pH Tester for Cheese, Wireless pH Tester for Cheese, pH Tester for Cheese
4 Pr EL imi NA ry Ex A mi NAT i ON 1. PRELIMINARY EXAMINATION Remove the tester and accessories from packaging and examine them carefully. For further assistance, please contact your
5 GENE r AL & FUNCT i ONAL DESC ri PT i ON 3. GENERAL DESCRIPTION & INTENDED USE HI9810322 is a professional wireless pH tester, part of Hanna Instruments HALO2 family.
File Info : application/pdf, 12 Pages, 681.49KB
DocumentDocumentINSTRUCTION MANUAL HI9810322 Wireless pH Tester for Cheese with built-in specialized electrode Foodcare Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using this instrument. This manual will provide you with the necessary information for correct use of this instrument, as well as a precise idea of its versatility. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com or view our contact list at www.hannainst.com. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA. TABLE OF CONTENTS TABLE OF CONTENTS 1. Preliminary Examination ..................................................................................................................4 2. Specifications ..................................................................................................................................4 3. General Description & Intended Use ..................................................................................................5 Operating Modes......................................................................................................................5 Probe Features .........................................................................................................................5 4. Functional Description & LCD Display.................................................................................................5 5. General Operations ..........................................................................................................................6 Turning the Tester On & Off .......................................................................................................6 Battery Replacement ................................................................................................................6 6. Setup .............................................................................................................................................6 Temperature Unit ....................................................................................................................6 Auto-Off Interval ......................................................................................................................6 Calibration Points .....................................................................................................................6 Buffer Set ................................................................................................................................6 pH Resolution ..........................................................................................................................6 Bluetooth® Wireless Mode ......................................................................................................6 Bluetooth Pairing .....................................................................................................................7 Date & Time ............................................................................................................................7 7. Bluetooth........................................................................................................................................7 8. Hanna Lab Application.....................................................................................................................7 Tag a Measurement ..................................................................................................................7 9. Calibration ......................................................................................................................................7 Preparation & Guidelines...........................................................................................................7 Procedure ................................................................................................................................7 Stand-Alone Tester (Up to Three-Point Calibration) ......................................................................8 With Hanna Lab App (Up to Four-Point Calibration) ....................................................................8 10. Care & Maintenance ......................................................................................................................9 Storage ...................................................................................................................................9 11. Warning & Error Messages .............................................................................................................9 12. Abbreviations ................................................................................................................................9 13. Accessories..................................................................................................................................10 Recommendations for Users.................................................................................................................10 Warranty ...........................................................................................................................................10 Certification ........................................................................................................................................11 The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. 3 PRELIMINARy ExAMINATION 1. PRELIMINARY EXAMINATION Remove the tester and accessories from packaging and examine them carefully. For further assistance, please contact your local Hanna Instruments office or email us at tech@hannainst.com. Each HI9810322 is supplied with a starter kit consisting of: · pH 4.01 buffer solution, 20 mL sachet (2 pcs.) · Electrode storage solution, 13 mL dropper bottle (1 pc.) · pH 7.01 buffer solution, 20 mL sachet (2 pcs.) · 3V Lithium battery CR2032 · Cleaning solution for cheese deposits, 20 mL sachet (2 pcs.) · Instrument quality certificate and Instruction manual Note: Save all packing material until you are sure that the tester works correctly. Any damaged or defective item must be returned in its original packing material with the supplied accessories. 2. SPECIFICATIONS pH 0.00 to 12.00 pH Range mV * pH/mV conversion Temperature ** 0.0 to 60.0 °C (32.0 to 140.0 °F) pH 0.01 or 0.1 pH Resolution mV * 0.1 or 1 mV Temperature 0.1 °C; 0.1 °F Accuracy pH ±0.05 pH Temperature ±0.5 °C; ±0.9 °F Calibration Up to three points or four points * Automatic buffer recognition with Standard buffers Hanna (pH 1.68 *, 4.01, 7.01, 10.01) or NIST (pH 1.68 *, 4.01, 6.86, 9.18) Temperature compensation Automatic (ATC) or Manual (MTC) * Electrode Body material Glass Junction Reference cell Electrolyte Tip / Shape Outer diameter Length Polyvinylidene Fluoride (PVDF) Low Temperature (LT) Open Double, Ag/AgCl Viscolene Conic, Ø 6 x 10 mm (Ø 0.23 x 0.39") 13 mm (0.51") 75 mm (2.95") Battery type 3V Lithium CR2032 Battery life Approximately 1000 hours (500 hours with Bluetooth enabled) Environment 0 to 50 °C (32 to 122 °F) Casing IP65 ingress protection Dimensions 51 x 145 x 21 mm (2.0 x 5.7 x 0.8") Weight 45 g (1.6 oz.) * Available with Hanna Lab App ** Measuring outside the recommended operating temperature range may damage the gel electrolyte and void product warranty. Note: The tester can display measurements from 2.00 to 16.00 pH. Measurements outside of the pH range will flash. In this case assess the integrity of the tester and the type of measured sample. 4 GENERAL & FUNCTIONAL DESCRIPTION 9 3. GENERAL DESCRIPTION & INTENDED USE HI9810322 is a professional wireless pH tester, part of Hanna Instruments HALO2 family. · The integrated Bluetooth module allows the tester to be connected to a compatible smart device with the Hanna Lab App. · The tester has a compact, waterproof casing, and automatic pH calibration at up to three points, or four points when used with the Hanna Lab App. · Automatically compensated temperature readings are displayed on a large LCD. · Accurate and easy to use, the tester is designed to measure and monitor the pH levels in all steps of the cheese manufacturing process, while meeting the food-hygiene and Hazard Analysis Criteria Control Point (HACCP) regulations. Operating Modes The HI9810322 can be used as a stand-alone pH tester or connected to the Hanna Lab App. The Hanna Lab App turns a compatible smart device into a full-featured pH meter. Features include: electrode condition, GLP with time-stamp, live-readings, mV resolution, manual temperature compensation, stability criteria, calibration reminder, pH (mV) and temperature alarms, tester ID, and data sharing. Probe Features The food grade PVDF body material is easy to clean and disinfect. Resistant to most chemicals (e.g. solvents, sodium hypochlorite), ultraviolet light, and fungal growth, the PVDF body also has high-abrasion resistance and mechanical strength. The conical tip allows for easy penetration into solids and semisolids. The double junction design presents a silver-free electrolyte solution interacting with the sample, making the electrode less susceptible to clogging and guaranteeing a fast response and stable reading. Built-in temperature sensor at the tip of the pH electrode allows for rapid determination of the sample temperature and a high-accuracy temperature reading. 4. FUNCTIONAL DESCRIPTION & LCD DISPLAY Front & Back view LCD ON/OFF Maximum immersion level button Recommended immersion 08A-04 R 210-1067 Setup button HI9810322 Cheese pH Tester ID: 2AA9B04 IC: 122 C Contains FC pH Probe HI9810322 SN: XXXXXXXXX Made in Romania Battery cover LCD display 1 10 88.8.8 2 # 9 3 4 !& oe.oe.oe.oe 8 56 7 1 Calibration indicator 6 Temperature compensation 2 Stability indicator 7 Second LCD line 3 Battery percentage indicator 8 Temperature unit 4 Battery icon 9 First LCD line 5 Bluetooth icon 10 Measurement unit 5 GENERAL OPERATIONS 5. GENERAL OPERATIONS Turning the Tester On & Off · Turn the tester face down. Rotate the battery cover on the back of the tester counterclockwise and set it aside. Remove the battery insulation film. · Press the ON/OFF button to turn the tester on or off. Initialization screen displays all LCD segments, followed by the battery percentage. The tester enters measurement mode. Before the tester turns off, "OFF PWR" is displayed briefly. · Press and hold the ON/OFF button to turn the tester off when connected to Bluetooth. Battery Replacement Metallic pin 1. Turn off the tester. Turn the tester face down and rotate the battery cover counterclockwise. 2. Set the battery cover aside. Press the metallic pin to push old battery out. 3. Place the new battery with positive (+) sign facing out. 4. Reset the date and time in setup, or connect to the Hanna Lab App to update it automatically. 5. Align the mark on the cover with the open lock icon ( ) on the case. Rotate the cover clockwise until the mark on the cover aligns with the closed lock icon ( ). Note: Only use specified battery type. Dispose of old battery in accordance with local regulations. 6. SETUP The Setup button is located inside the battery compartment. After Setup configuration, replace the cover. Setup Menu Navigation · Press the Setup button to enter Setup mode and navigate menu items. · To exit Setup mode, press the Setup button after "SEt TIME" option is displayed. · Press the ON/OFF button to configure menu item options. Temperature Unit Option: °C or °F Press ON/OFF button to select desired temperature unit. °C T E M P Auto-Off Interval Option: 8, 60 min., or "----" (disabled) Press ON/OFF button to select desired interval. To save battery life, after the selected auto-off 8 AOFF interval has elapsed, the tester will automatically turn off. Calibration Points Option: 2P or 3P Press ON/OFF button to select between up to two- or up to three-point calibration. 2P CAL Buffer Set Option: 7.01 pH (Hanna) or 6.86 pH (NIST) Press ON/OFF button to select the calibration buffer set (Hanna or NIST). 7.01 BUFF pH Resolution Option: 0.01 pH or 0.1 pH Press the ON/OFF button to select resolution. 0.01 RES °F TEMP 60 AOFF ---AOFF 3P CAL 6.86 BUFF 0.1 RES Bluetooth Wireless Mode Option: On, PAIr, or OFF Press ON/OFF button to select Bluetooth 6 option at start-up. On PAIr OFF & BLU & BLU & BLU BLUETOOTh Bluetooth Pairing Option: dEL PAIr Press ON/OFF button to delete saved paired device. dEL & PAIR Date & Time Option: SEt TIME Press ON/OFF button to set the date and time. Option: YEAR, MO, DAY, HOUR, and MIN 2021 YEAR 3 MO Use the Setup button to select the option and press the ON/OFF button to change the selected option. 15 DAY 7. BLUETOOTH With "PAIr BLU" or "On BLU" selected in Setup, the Bluetooth icon (&) will blink for up to 45 seconds, indicating the tester is in discoverable mode. Once connected, the icon will stop blinking. If not connected, the icon is not displayed. · Select "On BLU", to enable Bluetooth without bonding. · Select "PAIr BLU", to enable Bluetooth with bonding. A 6-digit bonding pin is displayed the first time the tester and smart device are paired. Once the devices are paired, the bonding pin is not required when reconnected. · Select "OFF BLU", to disable Bluetooth. · Select "dEL PAIR", to delete all paired devices. If PAIr BLU is enabled, a bonding pin will need to be re-entered. 8. HANNA LAB APPLICATION · The Hanna Lab App is available on the App Store® and on Google Play. · Consult the Help section of the application for information on calibration, measurement, data logging, and sharing. · When the tester is in discoverable mode, it will appear in the list of "Available Devices". · Within the application, tap "Connect" to pair the tester with the device. All readings are transmitted directly to the application. Tag a Measurement Once connected to the application, the ON/OFF button can be pressed to tag the current reading. · Press the ON/OFF button from measurement mode. The display shows "SEt TAG", followed by "- TAG". · The reading on the application will flash green and the note icon ( ) will be displayed. Tap the note icon ( ) to add an annotation. 9. CALIBRATION 10.12 & 25.6 - & TAG Preparation & Guidelines 1. Remove the probe from the plastic storage cap. Save the cap for probe storage. 2. Rinse off any storage solution or salts that may be on the body. 3. Verify there is solution inside the pH bulb by shaking the probe down to restore continuity as the solution may have moved up the stem during shipping. 4. For best results, use a rinse beaker and a separate calibration beaker for each buffer. Discard rinsing buffers after use. Procedure For most applications it is recommended to start with pH 7.01 buffer (or pH 6.86). To restore factory defaults, press and hold the ON/OFF button. "CAL CLR" is displayed. Note: It is recommended to calibrate the electrode with buffers at the temperature it will be used at. App Store is a trademark of Apple, Inc. Google Play and the Google Play logo are trademarks of Google LLC. 7 CALIBRATION Stand-Alone Tester (Up to Three-Point Calibration) 1. Rinse the electrode tip with purified water and blot dry. Then rinse with the buffer being used for calibration. 2. Press and hold ON/OFF button until "CAL MODE" is displayed. 3. When "7.01 USE" or "6.86 USE" is displayed with "CAL" tag blinking, place the tip of the electrode in the correct buffer. CAL 7.01 MODE USE 4. When the buffer has been recognized, "REC" is displayed. "WAIT" is displayed with the stability indicator (#) blinking until the reading is stable. Wait until the measurement is stored and the stability indicator disappears. 7.01 # 7.01 REC WAIT 5. To save a one-point calibration and return to measurement mode, press the ON/OFF button. "CAL SAVE" is displayed briefly. With 2P option selected 6. Place the tip of the electrode in the second buffer rinse beaker, then in the second calibration buffer. Wait until the measurement is stored and the stability indicator disappears. 7. After the second point has been stored, "CAL SAVE" is displayed briefly and the tester will return to measurement mode automatically. With 3P option selected 6. Place the tip of the electrode in the second buffer rinse beaker, then in the second calibration buffer. Wait until the measurement is stored and the stability indicator disappears. 7. Place the tip of the electrode in the third buffer rinse beaker, then in the third calibration buffer. Wait until the measurement is stored and the stability indicator disappears. 8. After the third point has been stored, "CAL SAVE" is displayed briefly and the tester will return to measurement mode automatically. With Hanna Lab App (Up to Four-Point Calibration) Connect the tester to the Hanna Lab App and follow the calibration procedure. See the App Help section for the calibration procedure. 8 CARE & MAINTENANCE 10. CARE & MAINTENANCE · Never immerse the tester over the maximum immersion level. · Fresh buffers should be used for each calibration. Once the sachets are opened the buffer value can change over time. · If the electrode is slow or sluggish, soak it in cleaning solution for 20 minutes. Rinse with water and hydrate the electrode in storage solution for a minimum of 30 minutes before calibrating. · If measurements are taken successively, rinse the probe thoroughly in distilled or deionized water to eliminate cross-contamination between measurements. Storage To ensure a quick response, the glass tip and junction should be kept hydrated. When not in use, add a few drops of storage solution to the storage cap. If storage solution is not available, pH 4.01 or pH 7.01 buffer can be used. Note: Do not store the electrode in distilled or deionized water. 11. WARNING & ERROR MESSAGES ---WRNG "---- WRNG" displayed during calibration. Invalid buffer. Check the buffer value and use fresh buffer. 12.02 23.7 Measured value displayed blinking. Measured value is out of electrode range. Clean the electrode to improve condition. ! 8.02 23.7 Battery icon (!) displayed blinking. Battery is below 10 %, replace the battery. BAtt DEAD "BAtt DEAD" and tester turns off. Depleted battery, replace the battery. 12. ABBREVIATIONS ATC Automatic Temperature Compensation GLP Good Laboratory Practice MTC Manual Temperature Compensation NIST National Institute of Standards and Technology 9 ACCESSORIES 13. ACCESSORIES Ordering Information Product Description pH Buffer Solution HI50016-02 pH 1.68 buffer solution, 20 mL sachet (25 pcs.) HI70004P pH 4.01 buffer solution, 20 mL sachet (25 pcs.) HI70006P pH 6.86 buffer solution, 20 mL sachet (25 pcs.) HI70007P pH 7.01 buffer solution, 20 mL sachet (25 pcs.) HI70009P pH 9.18 buffer solution, 20 mL sachet (25 pcs.) HI70010P pH 10.01 buffer solution, 20 mL sachet (25 pcs.) HI77400P pH 4.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each) HI770710P pH 10.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each) Electrode Cleaning Solution HI700601P Electrode cleaning solution for general use, 20 mL sachet (25 pcs.) HI700630P Meat, grease, and fats acid cleaning solution, 20 mL sachet (25 pcs.) HI700642P Cleaning solution for cheese deposits, 20 mL sachet (25 pcs.) Electrode Storage Solution HI70300L Electrode storage solution, 500 mL HI70300M Electrode storage solution, 230 mL HI70300S Electrode storage solution, 30 mL dropper HI9072 Electrode storage solution, 13 mL dropper RECOMMENDATIONS FOR USERS Before using this product, make sure it is entirely suitable for your specific application and for the environment in which it is used. Any variation introduced by the user to the supplied equipment may degrade the tester's performance. For your and the tester's safety do not use or store it in hazardous environments. WARRANTY HI9810322 is warranted for a period of one year against defects in workmanship and materials when used for its intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due to accidents, misuse, tampering, or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna Instruments office. If under warranty, report the model number, date of purchase, serial number, and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the tester is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization (RGA) number from the Technical Service department and then send it with shipping costs prepaid. When shipping any product, make sure it is shipped back in compliance with shipping regulations, thoroughly cleaned and free of any chemicals, and is properly packaged for complete protection. 10 MAN9810322 08/21 CERTIFICATION All Hanna Instruments conform to the CE European Directives. Disposal of Electrical and Electronic Equipment. The product should not be treated as household waste. Instead, hand it over to the appropriate collection point for the recycling of electrical and electronic equipment, which will conserve natural resources. Disposal of waste batteries. This product contains batteries, do not dispose of them with other household waste. Hand them over to the appropriate collection point for recycling. Ensuring proper product and battery disposal prevents potential negative consequences for the environment and human health. For more information, contact your city, your local household waste disposal service, or the place of purchase. Regulatory Notices for the stand-alone, Bluetooth, low-energy module. United States (FCC) FCC ID: 2AA9B04. This device complies with FCC Rules, Part 15 Subpart C "Intentional Radiators" and Subpart B, Chapter §15.105. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case, users are required to correct the interference at their own expense. Canada (ISED) IC: 12208A-04. This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Australia / New Zealand (RCM) BMD-300 complies with the AS/NZS 4268:2017. Japan (MIC) South Korea (KCC) Brazil (ANATEL): Contains ANATEL approved module # 00820-21-05903. Mexico (IFETEL): Este equipo contiene el módulo con IFT #: NYCE/CT/0146/17/TS. R-CRM-Rgd-BMD-300 Hanna Instruments reserves the right to modify the design, construction or appearance of its products without advance notice. World Headquarters Hanna Instruments Inc. Highland Industrial Park 584 Park East Drive Woonsocket, RI 02895 USA www.hannainst.com MAN9810322 Printed in ROMANIAAdobe PDF Library 15.0 Adobe InDesign 16.3 (Macintosh)