Instruction Manual for MRCOOL models including: 24, 30, 36, 42, VersaPro Series Gas Package Unit, VersaPro Series, Gas Package Unit, Package Unit
MRCOOL VersaPro 36K BTU Central Gas & Electric Package Unit - 13.4 SEE
MRCOOL VersaPro 24K BTU Central Gas & Electric Package Unit - 13.4 SEE
File Info : application/pdf, 13 Pages, 10.18MB
DocumentDocumentVersaProTM Series Gas Package Unit 13.4 SEER2 Capacity: 24-60 kBTU/h Contents: 1 NOMENCLATURE.......................................................2 2 SPECIFICATIONS.........................................................3 3 DIMENSIONS..............................................................5 4 AIRFLOW DATA...........................................................6 5 WIRING DIAGRAMS..................................................8 Features LP conversion kit provided. Aluminized steel tubular heat exchanger. Quiet multi-speed circulation blower. Direct spark ignition. High quality heat exchanger. Horizontal or down flow application. Convenient access panels. AHRI Certified and ETL listed. Revision Date: 07/03/2024 VersaProTM Gas Package Unit 1 Nomenclature M P G 24 S 060 M 4 13 B 1 2 3 4 5 6 7 8 9 10 Legend No. 1 2 3 Code M P G 4 24 5 S 6 060 7 M 8 4 9 13 10 B Remarks MRCOOL Packaged Gas & Electric Cooling Capacity: 24: 24 kBtu/h; 30: 30 kBtu/h; 36: 36 kBtu/h; 42: 42 kBtu/h; 48: 48 kBtu/h; 60: 60 kBtu/h; Stage type: S: Single stage; M: Multi-speed Heating capacity: 060: 60 kBtu/h; 090: 90 kBtu/h; 110: 110 kBtu/h; M = Multi-Position (Horizontal/Downflow H = Horizontal Refrigerant type: 4 = R410A SEER2: 13.4 3rd Generation 2 VersaProTM Gas Package Unit 2 Specifications MPG24S060M413B MPG30S060M413B MPG36S090M413B MPG42S090M413B NOMINAL CAPACITY Cooling (BTU/h) Heating (BTU/h) Input Heating (BTU/h) Output AFUE Temperature Rise Range (F) ELECTRICAL DATA Voltage / Phase (60 Hz) Min. / Max. Voltage MCA MOP COMPRESSOR Type Stage RLA LRA OUTDOOR COIL Type Tube Size(O.D) OUTDOOR FAN MOTOR Motor Type Horsepower (HP) Full Load Amps (FLA) Rated RPM INDOOR COIL Type Tube Size(O.D) INDOOR BLOWER MOTOR Motor Type Capacitor(uF) Horsepower (HP) Full Load Amps (FLA) Rated RPM REFRIGERATION SYSTEM Refrigerant Control Refrigerant Charge (oz.) SOUND POWER (DB) 24,000 60000 48000 81 30-60 208/230 / 1 187/253 19 25 Rotary Single 11.0 43.0 Microchannel 20/32 PSC 1/12 0.61 900 Tube & Fin 9/32 ECM / 1/2 4.2 1050 Orifice 47.6 79 30,000 60000 48000 81 30-60 208/230 / 1 187/253 21 30 Rotary Single 13.0 58.0 Microchannel 20/32 PSC 1/6 1 850 Tube & Fin 9/32 ECM / 1/2 4.2 1050 Orifice 52.9 79 36,000 90000 72000 81 40-70 208/230 / 1 187/253 23 35 Rotary Single 14.0 72.0 Microchannel 20/32 PSC 1/6 1 850 Tube & Fin 9/32 ECM / 1/2 4.2 1050 Orifice 52.9 79 42000 90000 72000 81 35-65 208/230 / 1 187/253 28 40 Scroll Single 16 112.3 Microchannel 20/32 PSC 1/3 1.9 1050 Tube & Fin 9/32 ECM / 3/4 5.7 1050 Orifice 70.5 80 3 VersaProTM Gas Package Unit 2 Specifications MPG48S090M413B MPG60S110M413B NOMINAL CAPACITY Cooling (BTU/h) Heating (BTU/h) Input Heating (BTU/h) Output AFUE Temperature Rise Range (F) ELECTRICAL DATA Voltage / Phase (60 Hz) Min. / Max. Voltage MCA MOP COMPRESSOR Type Stage RLA LRA OUTDOOR COIL Type Tube Size(O.D) OUTDOOR FAN MOTOR Motor Type Horsepower (HP) Full Load Amps (FLA) Rated RPM INDOOR COIL Type Tube Size(O.D) INDOOR BLOWER MOTOR Motor Type Capacitor(uF) Horsepower (HP) Full Load Amps (FLA) Rated RPM REFRIGERATION SYSTEM Refrigerant Control Refrigerant Charge (oz.) SOUND POWER (DB) 48,000 90000 72000 81 30-60 208/230 / 1 187/253 31 50 Rotary Single 13.0 58.0 Microchannel 20/32 PSC 1/3 1.9 1050 Tube & Fin 9/32 ECM / 3/4 5.7 1050 Orifice 72.3 80 60000 110000 88000 81 30-60 208/230 / 1 187/253 37 60 Scroll Single 16.0 112.3 Microchannel 20/32 PSC 1/3 1.9 1050 Tube & Fin 9/32 ECM / 3/4 5.7 1050 Orifice 74.1 80 4 VersaProTM Gas Package Unit 3 Dimensions Height Width Length MPG24S060M413B MPG30S060M413B MPG36S090M413B MPG42S090M413B UNIT DIMENSION AND WEIGHTS Height (in.) Width (in.) Length (in.) Net Weight (lbs.) 46-13/16 35-1/16 50-11/16 428 46-13/16 35-1/16 50-11/16 437 46-13/16 35-1/16 50-11/16 443 46-13/16 35-1/16 50-11/16 474 MPG48S090M413B MPG60S110M413B UNIT DIMENSION AND WEIGHTS Height (in.) Width (in.) Length (in.) Net Weight (lbs.) 51-7/16 44-13/16 50-9/16 536 51-7/16 44-13/16 50-9/16 569 5 VersaProTM Gas Package Unit 4 Airflow Data Model Number Motor Speed External Static Pressure-Inches W.C.[kPa] 0[0] 0.1[.02] 0.2[.05] 0.3[.07] 0.4[.10] 0.5[.12] 0.6[.15] 0.7[.17] 0.8[.20] 0.9[.23] 1.0[.25] CFM / 855 792 727 669 / / / / / / Low (Tap1) Current/A / 1.39 1.44 1.46 1.5 / / / / / / Power/W / 140 146 147 152 / / / / / / CFM / / / / 827 771 689 621 568 / / Middle-1 (Tap2) Current/A / / / / 1.94 2 2.05 2.08 2.11 / / Power/W / / / / 212 221 225 230 234 / / 24 CFM / / / / / / / 846 774 710 660 Middle-2 (Tap3) Current/A / / / / / / / 2.72 2.73 2.82 2.86 Power/W / / / / / / / 317 312 330 335 CFM / / / / / / / / / 844 797 Middle-3 (Tap4) Current/A / / / / / / / / / 3.24 3.28 Power/W / / / / / / / / / 385 391 CFM 917 855 792 / / / / / / / / Low (Tap1) Current/A 1.37 1.39 1.44 / / / / / / / / Power/W 137 140 146 / / / / / / / / CFM 1051 997 940 885 827 771 / / / / / Middle-1 (Tap2) Current/A 1.78 1.81 1.86 1.88 1.94 2 / / / / / Power/W 191 196 201 201 212 221 / / / / / CFM / / / 1049 995 947 898 846 774 710 / 30 Middle-2 (Tap3) Current/A / / / 2.51 2.57 2.6 2.67 2.72 2.73 2.82 / Power/W / / / 288 297 299 311 317 312 330 / CFM / / / / / 1045 997 951 908 844 797 Middle-3 (Tap4) Current/A / / / / / 3.03 3.04 3.13 3.18 3.24 3.28 Power/W / / / / / 359 354 371 378 385 391 CFM / / / / / / / / / 1032 991 High (Tap5) Current/A / / / / / / / / / 4.03 3.98 Power/W / / / / / / / / / 495 482 CFM 917 855 / / / / / / / / / Low (Tap1) Current/A 1.37 1.39 / / / / / / / / / Power/W 137 140 / / / / / / / / / CFM 1051 997 940 885 / / / / / / / Middle-1 (Tap2) Current/A 1.78 1.81 1.86 1.88 / / / / / / / Power/W 191 196 201 201 / / / / / / / CFM 1204 1153 1100 1049 995 947 898 / / / / 36 Middle-2 (Tap3) Current/A 2.4 2.45 2.44 2.51 2.57 2.6 2.67 / / / / Power/W 275 282 276 288 297 299 311 / / / / CFM 1281 1240 1190 1142 1092 1045 997 951 908 / / Middle-3 (Tap4) Current/A 2.82 2.84 2.85 2.96 3 3.03 3.04 3.13 3.18 / / Power/W 331 333 330 350 357 359 354 371 378 / / CFM / / / / 1280 1244 1194 1140 1083 1032 991 High (Tap5) Current/A / / / / 3.95 4.08 4.07 4 4.06 4.03 3.98 Power/W / / / / 481 507 504 486 502 495 482 6 VersaProTM Gas Package Unit 4 Airflow Data Model Number Motor Speed External Static Pressure-Inches W.C.[kPa] 0[0] 0.1[.02] 0.2[.05] 0.3[.07] 0.4[.10] 0.5[.12] 0.6[.15] 0.7[.17] 0.8[.20] 0.9[.23] 1.0[.25] CFM 1153 1102 1056 / / / / / / / / Middle-1 (Tap2) Current/A 2.09 2.13 2.18 / / / / / / / / Power/W 227 233 239 / / / / / / / / CFM 1426 1388 1343 1306 1267 1229 1192 1156 1093 / / Middle-2 (Tap3) Current/A 3.49 3.53 3.55 3.66 3.71 3.77 3.84 3.88 3.92 / / Power/W 416 422 418 438 445 453 463 468 473 / / 42 CFM / / / / 1472 1428 1392 1354 1309 / / Middle-3 (Tap4) Current/A / / / / 5.08 5.06 5.09 5.13 5.12 / / Power/W / / / / 634 629 633 639 638 / / CFM / / / / / 1500 1460 1398 1321 / / High (Tap5) Current/A / / / / / 5.65 5.61 5.41 5.19 / / Power/W / / / / / 710 700 670 640 / / CFM 1251 / / / / / / / / / / Middle-1 (Tap2) Current/A 1.67 / / / / / / / / / / Power/W 192 / / / / / / / / / / CFM 1547 1473 1424 1374 1323 1267 1213 / / / / Middle-2 (Tap3) Current/A 2.8 2.87 2.95 3.04 3.12 3.21 3.3 / / / / 48 Power/W 340 350 360 371 382 394 407 / / / / CFM 1789 1741 1695 1649 1605 1559 1510 1460 1409 1359 1313 Middle-3 (Tap4) Current/A 4.11 4.19 4.28 4.36 4.45 4.54 4.64 4.74 4.83 4.92 5 Power/W 517 528 540 551 564 576 589 603 615 627 639 CFM / / / / / 1755 1696 1630 1563 1490 1438 High (Tap5) Current/A / / / / / 5.79 5.76 5.73 5.71 5.68 5.66 Power/W / / / / / 750 745 741 737 733 730 CFM 1547 1473 / / / / / / / / / Middle-2 (Tap3) Current/A 2.8 2.87 / / / / / / / / / Power/W 340 350 / / / / / / / / / CFM 1789 1741 1695 1649 1605 1559 1510 1460 / / / 60 Middle-3 (Tap4) Current/A 4.11 4.19 4.28 4.36 4.45 4.54 4.64 4.74 / / / Power/W 517 528 540 551 564 576 589 603 / / / CFM 2035 1976 1927 1875 1815 1755 1696 1630 1563 1490 1438 High (Tap5) Current/A 5.66 5.74 5.81 5.85 5.82 5.79 5.76 5.73 5.71 5.68 5.66 Power/W 733 744 754 758 754 750 745 741 737 733 730 Airflow performance data is based on cooling performance with a coil and no filter in place. Use this performance table for appropriate unit size, external static applied to unit and allow operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. 7 J4PG4024E1060AA VersaProTM Gas Package Unit 5 Wiring Diagrams MPG24S060M413B 8 GAS BOARD GAS BOARD LED CODE STEADY ON NORMAL OPERATION OFF GAS BOARD FAILURE o STEADY FLASH W FAULTS 2 2FLASH 1HR.LOCKOUT 3 3FLASH PRESS.SW 4 4FLASH 5 5FLASH LIM OPEN FLAME W/O GAS 6 6FLASH ROLLOUT 7 6FLASH W1/W2 SWAPPED CODE CC COMP OFM IFM IND RC1 RC2 HPC LPC HGS XFMR FUSE GND TDB DESCRIPTION COMPRESSOR CONTACTOR COMPRESSOR OUTDOOR FAN MOTOR INDOOR FAN MOTOR INDUCED DRAFT BLOWER COMPRESSOR RUN CAPACITOR OUTDOOR FAN MOTOR RUN CAPACITOR HIGH PRESSURE CUT-OUT CONTROL LOW PRESSURE CUT-OUT CONTROL HOT GAS/COMPRESSOR TOP SWITCH TRANSFORMER T3.15A/250V GROUND CHASSIS TIME DELAY BOARD FACTORY STANDARD FIELD INSTALLED FACTORY OPTIONAL USE COPPER CONDUCTORS ONLY WARNING CABINET MUST BE PERMANENTLY GROUNDED AND ALL WIRING TO CONFORM TO I.E.C,N.E.C, C.L.C,AND LOCAL CODES AS APPLICABLE REPLACEMENT WIRE MUST BE THE SAME GAUGE AND INSULATION TYPE AS ORIGINAL WIRE. The wiring diagram shown is for reference only, it maybe different from the actual product . NOTE2:If the input voltage is 208V,take the white wire to 208V terminal. J4PG4030E1060AA VersaProTM Gas Package Unit Wiring Diagrams MPG30S060M413B 9 GAS BOARD GAS BOARD LED CODE STEADY ON NORMAL OPERATION OFF GAS BOARD FAILURE o STEADY FLASH W FAULTS 2 2FLASH 1HR.LOCKOUT 3 3FLASH PRESS.SW 4 4FLASH 5 5FLASH 6 6FLASH 7 6FLASH LIM OPEN FLAME W/O GAS ROLLOUT W1/W2 SWAPPED CODE CC COMP OFM IFM IND RC1 RC2 HPC LPC HGS XFMR FUSE GND TDB DESCRIPTION COMPRESSOR CONTACTOR COMPRESSOR OUTDOOR FAN MOTOR INDOOR FAN MOTOR INDUCED DRAFT BLOWER COMPRESSOR RUN CAPACITOR OUTDOOR FAN MOTOR RUN CAPACITOR HIGH PRESSURE CUT-OUT CONTROL LOW PRESSURE CUT-OUT CONTROL HOT GAS/COMPRESSOR TOP SWITCH TRANSFORMER T3.15A/250V GROUND CHASSIS TIME DELAY BOARD FACTORY STANDARD FIELD INSTALLED FACTORY OPTIONAL USE COPPER CONDUCTORS ONLY WARNING CABINET MUST BE PERMANENTLY GROUNDED AND ALL WIRING TO CONFORM TO I.E.C,N.E.C, C.L.C,AND LOCAL CODES AS APPLICABLE REPLACEMENT WIRE MUST BE THE SAME GAUGE AND INSULATION TYPE AS ORIGINAL WIRE. The wiring diagram shown is for reference only, it maybe different from the actual product . NOTE2:If the input voltage is 208V,take the white wire to 208V terminal. J4PG4036E1090AA VersaProTM Gas Package Unit Wiring Diagrams MPG36S090M413B 10 GAS BOARD GAS BOARD LED CODE STEADY ON NORMAL OPERATION OFF GAS BOARD FAILURE o STEADY FLASH W FAULTS 2 2FLASH 1HR.LOCKOUT 3 3FLASH PRESS.SW 4 4FLASH 5 5FLASH 6 6FLASH LIM OPEN FLAME W/O GAS ROLLOUT 7 6FLASH W1/W2 SWAPPED CODE CC COMP OFM IFM IND RC1 RC2 HPC LPC HGS XFMR FUSE GND TDB DESCRIPTION COMPRESSOR CONTACTOR COMPRESSOR OUTDOOR FAN MOTOR INDOOR FAN MOTOR INDUCED DRAFT BLOWER COMPRESSOR RUN CAPACITOR OUTDOOR FAN MOTOR RUN CAPACITOR HIGH PRESSURE CUT-OUT CONTROL LOW PRESSURE CUT-OUT CONTROL HOT GAS/COMPRESSOR TOP SWITCH TRANSFORMER T3.15A/250V GROUND CHASSIS TIME DELAY BOARD FACTORY STANDARD FIELD INSTALLED FACTORY OPTIONAL USE COPPER CONDUCTORS ONLY WARNING CABINET MUST BE PERMANENTLY GROUNDED AND ALL WIRING TO CONFORM TO I.E.C,N.E.C, C.L.C,AND LOCAL CODES AS APPLICABLE REPLACEMENT WIRE MUST BE THE SAME GAUGE AND INSULATION TYPE AS ORIGINAL WIRE. The wiring diagram shown is for reference only, it maybe different from the actual product . NOTE2:If the input voltage is 208V,take the white wire to 208V terminal. J4PG4042E1090AA VersaProTM Gas Package Unit Wiring Diagrams MPG42S090M413B 11 GAS BOARD GAS BOARD LED CODE STEADY ON NORMAL OPERATION OFF GAS BOARD FAILURE o STEADY FLASH W FAULTS 2 2FLASH 1HR.LOCKOUT 3 3FLASH PRESS.SW 4 4FLASH 5 5FLASH LIM OPEN FLAME W/O GAS 6 6FLASH 7 6FLASH ROLLOUT W1/W2 SWAPPED CODE CC COMP OFM IFM IND RC1 RC2 HPC LPC HGS XFMR FUSE GND TDB DESCRIPTION COMPRESSOR CONTACTOR COMPRESSOR OUTDOOR FAN MOTOR INDOOR FAN MOTOR INDUCED DRAFT BLOWER COMPRESSOR RUN CAPACITOR OUTDOOR FAN MOTOR RUN CAPACITOR HIGH PRESSURE CUT-OUT CONTROL LOW PRESSURE CUT-OUT CONTROL HOT GAS/COMPRESSOR TOP SWITCH TRANSFORMER T3.15A/250V GROUND CHASSIS TIME DELAY BOARD FACTORY STANDARD FIELD INSTALLED FACTORY OPTIONAL USE COPPER CONDUCTORS ONLY WARNING CABINET MUST BE PERMANENTLY GROUNDED AND ALL WIRING TO CONFORM TO I.E.C,N.E.C, C.L.C,AND LOCAL CODES AS APPLICABLE REPLACEMENT WIRE MUST BE THE SAME GAUGE AND INSULATION TYPE AS ORIGINAL WIRE. The wiring diagram shown is for reference only, it maybe different from the actual product . NOTE2:If the input voltage is 208V,take the white wire to 208V terminal. J4PG4048E1090AA VersaProTM Gas Package Unit Wiring Diagrams MPG48S090M413B 12 GAS BOARD GAS BOARD LED CODE STEADY ON NORMAL OPERATION OFF GAS BOARD FAILURE o STEADY FLASH W FAULTS 2 2FLASH 1HR.LOCKOUT 3 3FLASH PRESS.SW 4 4FLASH 5 5FLASH LIM OPEN FLAME W/O GAS 6 6FLASH ROLLOUT 7 6FLASH W1/W2 SWAPPED CODE CC COMP OFM IFM IND RC1 RC2 HPC LPC HGS XFMR FUSE GND TDB DESCRIPTION COMPRESSOR CONTACTOR COMPRESSOR OUTDOOR FAN MOTOR INDOOR FAN MOTOR INDUCED DRAFT BLOWER COMPRESSOR RUN CAPACITOR OUTDOOR FAN MOTOR RUN CAPACITOR HIGH PRESSURE CUT-OUT CONTROL LOW PRESSURE CUT-OUT CONTROL HOT GAS/COMPRESSOR TOP SWITCH TRANSFORMER T3.15A/250V GROUND CHASSIS TIME DELAY BOARD FACTORY STANDARD FIELD INSTALLED FACTORY OPTIONAL USE COPPER CONDUCTORS ONLY WARNING CABINET MUST BE PERMANENTLY GROUNDED AND ALL WIRING TO CONFORM TO I.E.C,N.E.C, C.L.C,AND LOCAL CODES AS APPLICABLE REPLACEMENT WIRE MUST BE THE SAME GAUGE AND INSULATION TYPE AS ORIGINAL WIRE. The wiring diagram shown is for reference only, it maybe different from the actual product . NOTE2:If the input voltage is 208V,take the white wire to 208V terminal. J4PG4060E1110AA VersaProTM Gas Package Unit Wiring Diagrams MPG60S110M413B 13 GAS BOARD GAS BOARD LED CODE STEADY ON NORMAL OPERATION OFF GAS BOARD FAILURE o STEADY FLASH W FAULTS 2 2FLASH 1HR.LOCKOUT 3 3FLASH PRESS.SW 4 4FLASH 5 5FLASH LIM OPEN FLAME W/O GAS 6 6FLASH ROLLOUT 7 6FLASH W1/W2 SWAPPED CODE CC COMP OFM IFM IND RC1 RC2 HPC LPC HGS XFMR FUSE GND TDB DESCRIPTION COMPRESSOR CONTACTOR COMPRESSOR OUTDOOR FAN MOTOR INDOOR FAN MOTOR INDUCED DRAFT BLOWER COMPRESSOR RUN CAPACITOR OUTDOOR FAN MOTOR RUN CAPACITOR HIGH PRESSURE CUT-OUT CONTROL LOW PRESSURE CUT-OUT CONTROL HOT GAS/COMPRESSOR TOP SWITCH TRANSFORMER T3.15A/250V GROUND CHASSIS TIME DELAY BOARD FACTORY STANDARD FIELD INSTALLED FACTORY OPTIONAL USE COPPER CONDUCTORS ONLY WARNING CABINET MUST BE PERMANENTLY GROUNDED AND ALL WIRING TO CONFORM TO I.E.C,N.E.C, C.L.C,AND LOCAL CODES AS APPLICABLE REPLACEMENT WIRE MUST BE THE SAME GAUGE AND INSULATION TYPE AS ORIGINAL WIRE. The wiring diagram shown is for reference only, it maybe different from the actual product . NOTE2:If the input voltage is 208V,take the white wire to 208V terminal.Microsoft: Print To PDF