Instructions for iCOM models including: IC-R30 Handheld Scanner, IC-R30, Handheld Scanner, Scanner

ICOM CS-R30 (01) PDF MANUAL - Manual-Hub.com


File Info : application/pdf, 2 Pages, 1.11MB

PDF preview unavailable. Download the PDF instead.

ICOM CS-R30 (01)
Using a microSD card

D Saving the setting data onto a PC
NOTE: If you use a brand new microSD card, first format the card with the IC-R30. See section 1 of the IC-R30 BASIC MANUAL for details.
1. Save the receiver's setting data onto a microSD card. L See section 1 of the IC-R30 BASIC MANUAL for details.
2. Turn OFF the receiver, and remove the microSD card from the receiver.
3. Insert the microSD card into a memory card reader or the memory card slot of the PC, as shown below.
4. Copy the receiver's setting data (ICF file), stored in the [Setting] folder of the microSD card, to a PC local folder. L See "Saving the setting data onto a microSD card" below how to access the [Setting] folder.

microSD card

IC-R30

PC

PC

or

Into a memory card reader

Into the memory card slot

D Initial setup window
After starting up the CS-R30, "Initial Setup" is displayed. Before using the CS-R30, read the instructions thoroughly, and follow the steps below to make the initial setup in order to send the version information of your receiver to the CS-R30.
TIP: If you want to make the initial setup again, click the [CS-R30 Initial Setup] in the `CS-R30' group.
1. Click
2. Click
3. Click
1. Click the <microSD> radio button. 2. Click <Open...> to display the data file selection
window. Select the ICF file, saved in "Saving the setting data onto a PC," described above. 3. Click <OK> to read the selected file, and open the cloning screen. 4. Program each setting for each function, using the CS-R30. L See the Help file of the CSR30 for assistance. NOTE: When the receiver version information is not correctly sent to the software, some items may not be displayed in the software.

D Saving the setting data onto a microSD card
To load the setting data into the receiver, copy the setting data edited with the CS-R30 to the [Setting] folder on the microSD card. L See the IC-R30 ADVANCED MANUAL on how to load the setting data into the receiver.

The microSD card's folder composition

Csv

IC-R30

Gps RxLog Setting

Voice

Drag and drop the file* here.
* You can enter a file name of up to 20 characters.

INSTRUCTIONS
CLONING SOFTWARE
CS-R30

Thank you for choosing this Icom product. READ ALL INSTRUCTIONS carefully and completely before using this product.

System requirements

To use the software, the following hardware and software are required.

· Operating System (OS)

Select one of the following.

Microsoft® Windows® 10 Microsoft® Windows® 8.1

When using a USB cable

(Except for Microsoft® Windows® RT)

· USB cable

Microsoft® Windows® 7

(A-microB type, supplied with the receiver)

L These instructions are based on using Microsoft® Windows® 10.

L Directly connect the receiver to a PC's USB port.

· USB port (USB 1.1, 2.0, or 3.0 port)

When using a microSD card
· microSD card (user supplied) · Memory card slot built into the PC
or Memory card reader (User supplied) to read the microSD card L If you connect the IC-R30 to a PC using a USB cable, in the
SD Card mode you can use the receiver instead of a memory card slot or a memory card reader. See the IC-R30 ADVANCED MANUAL for details.

Programming information
· To prevent data loss, you should first read the receiver setting data into the CS-R30, or copy the setting data (ICF file) of the microSD card to the PC, and read the data into the CS-R30. Then edit or enter new software parameters.
· Before editing or entering new data, make a backup file onto your PC. A backup file enables easy restoring even if the setting data is accidentally deleted.

· While reading or writing (uploading) the data with the USB cable, NEVER turn OFF the receiver or the PC, and NEVER disconnect the USB cable. Otherwise, the data could be lost or deleted.
· While reading or writing the data to or from the microSD card, NEVER remove the microSD card or turn OFF the receiver. Otherwise, the data could be corrupted or the microSD card could be damaged.

­ 4 ­ 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan

A7453W-1EX

Printed in Japan © 2018 Icom Inc.

https://manual-hub.com/

Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries. Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries. All other products or brands are registered trademarks or trademarks of their respective holders.
­ 1 ­

Software installation

When installing the software, confirm Windows has completed its startup, and then log in as the administrator.

1. Confirm no other applications are running. 2. Insert the CD into a CD drive. 3. Double-click the "setup.exe" in the [CSR30] folder.
L If "User Account Control" is displayed, click <Yes> to continue.
4. "Choose Setup Language" is displayed. Select `English' (or `Japanese') and then click <Next>>.

7. "Choose Destination Location" is displayed. Click <Next>>. L If desired, click <Browse...> to select another destination folder before clicking <Next>>.

Select language
Click 5. "Welcome to the InstallShield Wizard for CS-R30" is
displayed. Click <Next>>.

Confirm Click
8. If "Windows Security" is displayed, click <Install>.
Click

9. After the installation has completed, "InstallShield Wizard Complete" is displayed. Click <Finish>.

Click
6. "User Information" is displayed. Enter your name, your company name (option), and the product ID number as described below. Click <Next>>. · Product ID: 388311-(6 digit serial number) · The serial number is on the CD. Example: When the serial number is XXXXXX*, enter "388311-XXXXXX" as the ID number. * XXXXXX is shown as an example only, and is not valid. (Hyphen) 388311-XXXXXX
Fixed 6 digit serial number
Click

Click
10. Eject the CD. 11. A `CS-R30' folder is created in the Windows Start
menu, and a shortcut icon is created on the desktop.
NOTE: You can uninstall the software using the "Apps & features" in the "System" menu. To get started, click on Start > Settings > System > Apps & features.

Using a USB cable

D Receiver and PC connection

Connect the USB cable as shown below.

IC-R30

NOTE: DO NOT connect the receiver to a PC through any USB hub.

PC USB cable (A-microB type)
To a USB port

D Initial setup window
After starting up the CS-R30, "Initial Setup" is displayed. Before using the CS-R30, read the instructions thoroughly, and follow the steps below to make the initial setup in order to send the version information of your receiver to the CS-R30.
TIP: If you want to make the initial setup again, click the [CS-R30 Initial Setup] in the `CS-R30' group.
Confirm that the receiver is connected to the PC with a USB cable and the power is turned ON.

D Cloning operation
Follow the steps described below to clone. 1. Push [MENU] on the receiver and enter the Clone
Mode. ([MENU] > Others > Clone > Clone Mode) 2. Click or select "Read <- Receiver" in the [Clone]
menu to start reading the data from the receiver. You can also click or select "Open... Ctrl+O" in the [File] menu to open an ICF file and write the file data to the receiver. 3. Set each setting for each function, using the CS-R30. L See the Help file of the CSR30 for assistance. 4. Push [MENU] on the receiver and enter the Clone Mode. 5. Click or select "Write -> Receiver" in the [Clone] menu to write the new or edited data into your receiver.
NOTE: After writing, the new or edited data will overwrite the current data.

1. Click 2. Click

While reading

While writing

6. Turn OFF the receiver, then turn it ON again to operate the receiver with the loaded data.

3. Click
1. Click <COM Port> radio button. 2. Click <Search...> to display the IC-R30 Search window.
Select the appropriate receiver and click <OK>, then the COM port number will be set in the input field. 3. Click <OK> to open the cloning screen.
NOTE: When the receiver version information is not correctly sent to the software, some items may not be displayed on the software.

When the writing is completed

­ 2 ­

https://manual-hub.com/

­ 3 ­

