Installation Guide for AVCOMM models including: 4006GX2 4 2G 1000M Unmanaged Ethernet Switch, 4006GX2, 4 2G 1000M Unmanaged Ethernet Switch, Unmanaged Ethernet Switch, Ethernet Switch, Switch

PowerPoint 簡報

Orwell Hsieh

Quick Installation Guide

4006GX2 4 2G 1000M Unmanaged Ethernet Switch 4006GX2 is a 4-port 10/100/1000Base-TX RJ-45 and 2-port 1000Base-X unmanaged Ethernet switch with reverse polarity


File Info : application/pdf, 1 Pages, 199.93KB

PDF preview unavailable. Download the PDF instead.

4006GX2 QIG CN V2.1
Quick Installation Guide
4006GX2 4+2G 1000M Unmanaged
Ethernet Switch
www.avcomm.cn
Overview
4006GX2 is a 4-port 10/100/1000Base-TX RJ-45 and 2-port 1000Base-X unmanaged Ethernet switch with reverse polarity protection of AC or DC input. It has ingenious appearance design and supports DIN Rail-mounted/wall-mounted to facilitate in various industrial network applications.
Package Checklist
· 1 x Product Unit · 2 x Mounting plate · 6 x Screw · 1 x Quick Installation Guide
Installation
DIN Rail-mounted To mount the switch on the DIN Rail track, insert the upper end of the DIN-Rail clip into the back of the DIN-Rail track from its upper side and lightly push the bottom of the DIN-Rail clip into the track. The DIN Rail should comply with DIN EN50022 standard. Using wrong DIN rail may cause unsafe installation. Grounding Screw For avoiding system damage by noise or electric shock, establish a direct connection between the grounding screw and the grounding surface prior to connecting devices.
AVCOMM Technologies, Inc

Wall-mounted Tighten the metal fixation plate by , then hang the machine with locked metal strip onto wall or machine cabinet.
Wiring the Power Input 1) Insert the positive and negative wires into the V+ and V- contact on
the terminal block connector. 2) Tighten screws when the wire is connected. 3) Connect the power wires to suitable DC Switching type power supply.
Appearance

1. Mounting bracket 2. Grounding screw 3. Power & relay alarm
input terminal 4. Power indicator PWR
Indicator

5. Alarm indicator FAIL 6. Fiber indicator FDX 7. Fiber port 8. Network port indicator 9. Network port

LED PWR FDX FAIL
RJ45

Status
Green On
Green Off
Green On
Green Blinking
Green Off
Red On
Red Off Green On Amber On Green On Amber Blinking Amber On Green Off Amber Blinking
Amber Off

Description Power is in normal condition Power is abnormal or power failure
Link is ready Link is established Link is not ready or link failure With alarm output Without alarm output
1000Base network is ready
1000Base network is established 10/100Base network is established or link
failure 10/100Base network is established
Link is not ready or link failure

Safety Precautions
 Keep DC power off before connecting to the terminal block connectors and ensure all connections are secure established.
 Do make sure that models connect to the corresponding supply voltage. The device is to be supplied by Limited Power Supply. The relay contact supports 0.5 A current, DC 24V
 Do not touch the surface of the switch while it is in operation!
Support
At AVCOMM, you can use the online service forms to request the support. The submitted forms are stored in server for AVCOMM team member to assign tasks and monitor the status of your service. Please feel free to write to www.avcomm.cn if you encounter any problems.
Warranty
5-year Global warranty are available for AVCOMM products assuring our customers that the products shall remain free from defects in workmanship or materials and conform in all material respects to AVCOMM specifications, or purchasers supplied and accepted specifications. The warranty is limited to the repair and/or replacement, at AVCOMM sole discretion, of the defective product during its warranty period. The customer must obtain a Return Merchandise Authorization (RMA) approval code prior to returning the defective Product to AVCOMM for service. The customer agrees to prepay shipping charges, to use the original shipping package or equivalent, and to ensure the product or assume the risk of loss or damage in transit. repaired or replaced products are warranted for ninety (90) days from the date of repair or replacement, or for the remainder of the original product's warranty period, whichever is longer.
Disclaimer
AVCOMM reserves the right to make changes to this QIG or to the product hardware at any time without notice. It is the user's responsibility to determine whether there have been any such updates or amendments herein. Defects, malfunctions, or failures of the warranted Product(s) caused by damage resulting from unforeseeable incidents (such as lightings, floods, fire, etc.), environmental and atmospheric disturbances, other external forces such as power line disturbances and surge, host computer malfunction and virus, incorrect power input, or incorrect cabling, incorrect grounding and damages caused by misuse, abuse and unauthorized alteration or repair are not warranted.
www.avcomm.cn



References